View all text of Subpart A [§ 433.10 - § 433.17]

§ 433.16 - New source performance standards (NSPS).

(a) Any new source subject to this subpart must achieve the following performance standards:

NSPS

Pollutant or pollutant property Maximum for any 1 day Monthly average shall not exceed Milligrams per liter (mg/l) Cadmium (T)0.110.07 Chromium (T)2.771.71 Copper (T)3.382.07 Lead (T)0.690.43 Nickel (T)3.982.38 Silver (T)0.430.24 Zinc (T)2.611.48 Cyanide (T)1.200.65 TTO2.13Oil and Grease5226 TSS6031 pH( 1)( 1)

1 Within 6.0 to 9.0.

(b) Alternatively, for industrial facilities with cyanide treatment, and upon agreement between a source subject to those limits and the pollution control authority, the following amenable cyanide limit may apply in place of the total cyanide limit specified in paragraph (a) of this section:

Pollutant or pollutant property Maximum for any 1 day Monthly average shall not exceed Milligrams per liter (mg/l) Cyanide (A)0.860.32

(c) No user subject to the provisions of this subpart shall augment the use of process wastewater or otherwise dilute the wastewater as a partial or total substitute for adequate treatment to achieve compliance with this limitation.

[48 FR 32485, July 15, 1983; 48 FR 43682, Sept. 26, 1983]