- Table 1 to Subpart CCCC of Part 60—Emission Limitations for Incinerators for Which Construction is Commenced After November 30, 1999, But no Later Than June 4, 2010, or for Which Modification or Reconstruction is Commenced on or After June 1, 2001, But no Later Than August 7, 2013

For the air pollutant You must meet this
emission limitation 1
Using this averaging time 2And determining compliance
using this method 2
Cadmium0.004 milligrams per dry standard cubic meter3-run average (1 hour minimum sample time per run)Performance test (Method 29 of appendix A of this part). Carbon monoxide157 parts per million by dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 10 at 40 CFR part 60, appendix A-4). Dioxin/Furan (toxic equivalency basis)0.41 nanograms per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meters per run)Performance test (Method 23 of appendix A-7 of this part). Hydrogen chloride62 parts per million by dry volume3-run average (For Method 26, collect a minimum volume of 120 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meter per run)Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8). Lead0.04 milligrams per dry standard cubic meter3-run average (1 hour minimum sample time per run)Performance test (Method 29 of appendix A of this part). Mercury0.47 milligrams per dry standard cubic meter3-run average (1 hour minimum sample time per run)Performance test (Method 29 of appendix A of this part). Nitrogen oxides388 parts per million by dry volume3-run average (for Method 7E, 1 hour minimum sample time per run)Performance test (Method 7 or 7E at 40 CFR part 60, appendix A-4). Opacity10 percent6-minute averagesPerformance test (Method 9 of appendix A of this part). Particulate matter70 milligrams per dry standard cubic meter3-run average (1 hour minimum sample time per run)Performance test (Method 5 or 29 of appendix A of this part). Sulfur dioxide20 parts per million by dry volume3-run average (For Method 6, collect a minimum volume of 20 liters per run. For Method 6C, collect sample for a minimum duration of 1 hour per run)Performance test (Method 6 or 6C at 40 CFR part 60, appendix A-4).

1 All emission limitations (except for opacity) are measured at 7 percent oxygen, dry basis at standard conditions.

2 In lieu of performance testing, you may use a CEMS or, for mercury, an integrated sorbent trap monitoring system, to demonstrate initial and continuing compliance with an emissions limit, as long as you comply with the CEMS or integrated sorbent trap monitoring system requirements applicable to the specific pollutant in §§ 60.2145 and 60.2165. As prescribed in § 60.2145(u), if you use a CEMS or an integrated sorbent trap monitoring system to demonstrate compliance with an emissions limit, your averaging time is a 30-day rolling average of 1-hour arithmetic average emission concentrations.