- Table 5 to Subpart CCCC of Part 60—Emission Limitations for Incinerators That Commenced Construction After June 4, 2010, or That Commenced Reconstruction or Modification After August 7, 2013

For the air pollutant You must meet this emission limitation 1Using this averaging time 2And determining compliance using
this method 2
Cadmium0.0023 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meter per run)Performance test (Method 29 at 40 CFR part 60, appendix A-8 of this part). Use ICPMS for the analytical finish. Carbon monoxide17 parts per million by dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 10 at 40 CFR part 60, appendix A-4). Dioxin/furan (Total Mass Basis)0.58 nanograms per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meters per run)Performance test (Method 23 at 40 CFR part 60, appendix A-7). Dioxin/furan (toxic equivalency basis)0.13 nanograms per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meter per run)Performance test (Method 23 at 40 CFR part 60, appendix A-7). Fugitive ashVisible emissions for no more than 5 percent of the hourly observation periodThree 1-hour observation periodsVisible emission test (Method 22 at 40 CFR part 60, appendix A-7). Hydrogen chloride0.091 parts per million by dry volume3-run average (For Method 26, collect a minimum volume of 360 liters per run. For Method 26A, collect a minimum volume of 3 dry standard cubic meters per run)Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8). Lead0.015 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meters per run)Performance test (Method 29 of appendix A-8 at 40 CFR part 60). Use ICPMS for the analytical finish. Mercury0.00084 milligrams per dry standard cubic meter3-run average (collect enough volume to meet a detection limit data quality objective of 0.03 ug/dry standard cubic meter)Performance test (Method 29 or 30B at 40 CFR part 60, appendix A-8) or ASTM D6784-02 (Reapproved 2008). 3Nitrogen oxides23 parts per million dry volume3-run average (for Method 7E, 1 hour minimum sample time per run)Performance test (Method 7 or 7E at 40 CFR part 60, appendix A-4). Particulate matter (filterable)18 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 2 dry standard cubic meters per run)Performance test (Method 5 or 29 at 40 CFR part 60, appendix A-3 or appendix A-8 at 40 CFR part 60). Sulfur dioxide11 parts per million dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 6 or 6C at 40 CFR part 60, appendix A-4).

1 All emission limitations are measured at 7 percent oxygen, dry basis at standard conditions. For dioxins/furans, you must meet either the Total Mass Limit or the toxic equivalency basis limit.

2 In lieu of performance testing, you may use a CEMS or, for mercury, an integrated sorbent trap monitoring system to demonstrate initial and continuing compliance with an emissions limit, as long as you comply with the CEMS or integrated sorbent trap monitoring system requirements applicable to the specific pollutant in §§ 60.2145 and 60.2165. As prescribed in § 60.2145(u), if you use a CEMS or an integrated sorbent trap monitoring system to demonstrate compliance with an emissions limit, your averaging time is a 30-day rolling average of 1-hour arithmetic average emission concentrations.

3 Incorporated by reference, see § 60.17.