- Table 6 to Subpart CCCC of Part 60—Emission Limitations for Energy Recovery Units That Commenced Construction After June 4, 2010, or That Commenced Reconstruction or Modification After August 7, 2013

For the air pollutant You must meet this emission limitation 1Using this averaging time 2And determining compliance using this method 2Liquid/gas Solids Cadmium0.023 milligrams per dry standard cubic meterBiomass—0.0014 milligrams per dry standard cubic meter. Coal—0.0017 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meters per run)Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use ICPMS for the analytical finish. Carbon monoxide35 parts per million dry volumeBiomass—240 parts per million dry volume. Coal—95 parts per million dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 10 at 40 CFR part 60, appendix A-4). Dioxin/furans (Total Mass Basis)No Total Mass Basis limit, must meet the toxic equivalency basis limit belowBiomass—0.52 nanograms per dry standard cubic meter. Coal—5.1 nanograms per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meters)Performance test (Method 23 at 40 CFR part 60, appendix A-7). Dioxins/furans (toxic equivalency basis)0.093 nanograms per dry standard cubic meterBiomass—0.076 nanograms per dry standard cubic meter. 3 Coal—0.075 nanograms per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meters per run)Performance test (Method 23 of appendix A-7 of this part). Fugitive ashVisible emissions for no more than 5 percent of the hourly observation periodThree 1-hour observation periodsVisible emission test (Method 22 at 40 CFR part 60, appendix A-7)Fugitive ash. Hydrogen chloride14 parts per million dry volumeBiomass—0.20 parts per million dry volume. Coal—58 parts per million dry volume3-run average (For Method 26, collect a minimum volume of 360 liters per run. For Method 26A, collect a minimum volume of 3 dry standard cubic meters per run)Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8). Lead0.096 milligrams per dry standard cubic meterBiomass—0.014 milligrams per dry standard cubic meter. Coal—0.057 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 4 dry standard cubic meters per run)Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use ICPMS for the analytical finish. Mercury0.00056 milligrams per dry standard cubic meterBiomass—0.0022 milligrams per dry standard cubic meter. Coal—0.013 milligrams per dry standard cubic meter3-run average (collect enough volume to meet an in-stack detection limit data quality objective of 0.03 ug/dscm)Performance test (Method 29 or 30B at 40 CFR part 60, appendix A-8) or ASTM D6784-02 (Reapproved 2008). 3Nitrogen oxides76 parts per million dry volumeBiomass—290 parts per million dry volume. Coal—460 parts per million dry volume3-run average (for Method 7E, 1 hour minimum sample time per run)Performance test (Method 7 or 7E at 40 CFR part 60, appendix A-4). Particulate matter (filterable)110 milligrams per dry standard cubic meterBiomass—5.1 milligrams per dry standard cubic meter. Coal—130 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 1 dry standard cubic meter per run)Performance test (Method 5 or 29 at 40 CFR part 60, appendix A-3 or appendix A-8). Sulfur dioxide720 parts per million dry volumeBiomass—7.3 parts per million dry volume. Coal—850 parts per million dry volume3-run average (for Method 6, collect a minimum of 60 liters, for Method 6C, 1 hour minimum sample time per run)Performance test (Method 6 or 6C at 40 CFR part 60, appendix A-4).

1 All emission limitations are measured at 7 percent oxygen, dry basis at standard conditions. For dioxins/furans, you must meet either the Total Mass Basis limit or the toxic equivalency basis limit.

2 In lieu of performance testing, you may use a CEMS or, for mercury, an integrated sorbent trap monitoring system to demonstrate initial and continuing compliance with an emissions limit, as long as you comply with the CEMS or integrated sorbent trap monitoring system requirements applicable to the specific pollutant in §§ 60.2145 and 60.2165. As prescribed in § 60.2145(u), if you use a CEMS or an integrated sorbent trap monitoring system to demonstrate compliance with an emissions limit, your averaging time is a 30-day rolling average of 1-hour arithmetic average emission concentrations.

3 Incorporated by reference, see § 60.17.

[85 FR 63404, Oct. 7, 2020]