§ 192.115 - Temperature derating factor (T) for steel pipe.
The temperature derating factor to be used in the design formula in § 192.105 is determined as follows:
Gas temperature in degrees
Fahrenheit (Celsius) | Temperature
derating factor (T) | 250 °F (121 °C) or less | 1.000 | 300 °F (149 °C) | 0.967 | 350 °F (177 °C) | 0.933 | 400 °F (204 °C) | 0.900 | 450 °F (232 °C) | 0.867 |
---|