View all text of Subpart F [§ 610.50 - § 610.53]

§ 610.53 - Dating periods for Whole Blood and blood components.

(a) General. Dating periods for Whole Blood and blood components are specified in the table in paragraph (b) of this section.

(b) Table of dating periods. In using the table in this paragraph, when a product in column A is stored at the storage temperature prescribed in column B, storage of a product must not exceed the dating period specified in column C, unless a different dating period is specified in the instructions for use by the blood collection, processing and storage system approved or cleared for such use by FDA. Container labels for each product must include the recommended storage temperatures.

Whole Blood and Blood Components Storage Temperatures and Dating Periods

A B C Product Storage temperature Dating period Whole BloodACD, CPD, CP2DBetween 1 and 6 °C21 days from date of collection. CPDA-1do 135 days from date of collection. Red Blood CellsACD, CPD, CP2DBetween 1 and 6 °C21 days from date of collection. CPDA-1do35 days from date of collection. Additive solutionsdo42 days from date of collection. Open system
(e.g., deglycerolized, washed)
do24 hours after entering bag. Deglycerolized in closed system with additive solution addeddo14 days after entering bag. Irradiateddo28 days from date of irradiation or original dating, whichever is shorter. Frozen−65 °C or colder10 years from date of collection. PlateletsPlateletsBetween 20 and 24 °C5 days from date of collection. PlateletsOther temperatures according to storage bag instructionsAs specified in the instructions for use by the blood collection, processing and storage system approved or cleared for such use by FDA. PlasmaFresh Frozen Plasma−18 °C or colder1 year from date of collection. Plasma Frozen Within 24 Hours After Phlebotomydo1 year from date of collection. Plasma Frozen Within 24 Hours After Phlebotomy Held at Room Temperature Up To 24 Hours After Phlebotomydo1 year from date of collection. Plasma Cryoprecipitate Reduceddo1 year from date of collection. Plasmado5 years from date of collection. Liquid PlasmaBetween 1 and 6 °C5 days from end of Whole Blood dating period. Source Plasma (frozen injectable)−20 °C or colder10 years from date of collection. Source Plasma Liquid (injectable)10 °C or colderAccording to approved biologics license application. Source Plasma (noninjectable)Temperature appropriate for final product10 years from date of collection. Therapeutic Exchange Plasma−20 °C or colder10 years from date of collection. Cryoprecipitated AHFCryoprecipitated AHF−18 °C or colder1 year from date of collection of source blood or from date of collection of oldest source blood in pre-storage pool. Source LeukocytesSource LeukocytesTemperature appropriate for final productIn lieu of expiration date, the collection date must appear on the label.

1 The abbreviation “do.” for ditto is used in the table to indicate that the previous line is being repeated.

[81 FR 26691, May 4, 2016]