Collapse to view only § 56.6900 - Damaged or deteriorated explosive material.
Storage
- SECTION § 56.6100 - Separation of stored explosive material.
- SECTION § 56.6101 - Areas around explosive material storage facilities.
- SECTION § 56.6102 - Explosive material storage practices.
- SECTION § 56.6130 - Explosive material storage facilities.
- SECTION § 56.6131 - Location of explosive material storage facilities.
- SECTION § 56.6132 - Magazine requirements.
- SECTION § 56.6133 - Powder chests.
- § 56.6000 - Definitions.
Transportation
- SECTION § 56.6300 - Control of blasting operations.
- SECTION § 56.6301 - Blasthole obstruction check.
- SECTION § 56.6302 - Separation of explosive material.
- SECTION § 56.6303 - Initiation preparation.
- SECTION § 56.6304 - Primer protection.
- SECTION § 56.6305 - Unused explosive material.
- SECTION § 56.6306 - Loading, blasting, and security.
- SECTION § 56.6307 - Drill stem loading.
- SECTION § 56.6308 - Initiation systems.
- SECTION § 56.6309 - Fuel oil requirements for ANFO.
- SECTION § 56.6310 - Misfire waiting period.
- SECTION § 56.6311 - Handling of misfires.
- SECTION § 56.6312 - Secondary blasting.
Electric Blasting
- SECTION § 56.6400 - Compatibility of electric detonators.
- SECTION § 56.6401 - Shunting.
- SECTION § 56.6402 - Deenergized circuits near detonators.
- SECTION § 56.6403 - Branch circuits.
- SECTION § 56.6404 - Separation of blasting circuits from power source.
- SECTION § 56.6405 - Firing devices.
- SECTION § 56.6406 - Duration of current flow.
- SECTION § 56.6407 - Circuit testing.
Nonelectric Blasting
Extraneous Electricity
Equipment/Tools
Maintenance
General Requirements
Storage
§ 56.6100 - Separation of stored explosive material.
(a) Detonators shall not be stored in the same magazine with other explosive material.
(b) When stored in the same magazine, blasting agents shall be separated from explosives, safety fuse, and detonating cord to prevent contamination.
§ 56.6101 - Areas around explosive material storage facilities.
(a) Areas surrounding storage facilities for explosive material shall be clear of rubbish, brush, dry grass, and trees for 25 feet in all directions, except that live trees 10 feet or taller need not be removed.
(b) Other combustibles shall not be stored or allowed to accumulate within 50 feet of explosive material. Combustible liquids shall be stored in a manner that ensures drainage will occur away from the explosive material storage facility in case of tank rupture.
§ 56.6102 - Explosive material storage practices.
(a) Explosive material shall be—
(1) Stored in a manner to facilitate use of oldest stocks first;
(2) Stored according to brand and grade in such a manner as to facilitate identification; and
(3) Stacked in a stable manner but not more than 8 feet high.
(b) Explosives and detonators shall be stored in closed nonconductive containers except that nonelectric detonating devices may be stored on nonconductive racks provided the case-insert instructions and the date-plant-shift code are maintained with the product.
§ 56.6130 - Explosive material storage facilities.
(a) Detonators and explosives shall be stored in magazines.
(b) Packaged blasting agents shall be stored in a magazine or other facility which is ventilated to prevent dampness and excessive heating, weather-resistant, and locked or attended. Drop trailers do not have to be ventilated if they are currently licensed by the Federal, State, or local authorities for over-the-road use. Facilities other than magazines used to store blasting agents shall contain only blasting agents.
(c) Bulk blasting agents shall be stored in weather-resistant bins or tanks which are locked, attended, or otherwise inaccessible to unauthorized entry.
(d) Facilities, bins or tanks shall be posted with the appropriate United States Department of Transportation placards or other appropriate warning signs that indicate the contents and are visible from each approach.
§ 56.6131 - Location of explosive material storage facilities.
(a) Storage facilities for any explosive material shall be—
(1) Located so that the forces generated by a storage facility explosion will not create a hazard to occupants in mine buildings and will not damage dams or electric substations; and
(2) Detached structures located outside the blast area and a sufficient distance from powerlines so that the powerlines, if damaged, would not contact the magazines.
(b) Operators should also be aware of regulations affecting storage facilities in 27 CFR part 55, in particular, 27 CFR 55.218 and 55.220. This document is available at any MSHA Metal and Nonmetal Safety and Health district office.
§ 56.6132 - Magazine requirements.
(a) Magazines shall be—
(1) Structurally sound;
(2) Noncombustible or the exterior covered with fire-resistant material;
(3) Bullet resistant;
(4) Made of nonsparking material on the inside;
(5) Ventilated to control dampness and excessive heating within the magazine;
(6) Posted with the appropriate United States Department of Transportation placards or other appropriate warning signs that indicate the contents and are visible from each approach, so located that a bullet passing through any of the signs will not strike the magazine;
(7) Kept clean and dry inside;
(8) Unlighted or lighted by devices that are specifically designed for use in magazines and which do not create a fire or explosion hazard;
(9) Unheated or heated only with devices that do not create a fire or explosion hazard;
(10) Locked when unattended; and
(11) Used exclusively for the storage of explosive material except for essential nonsparking equipment used for the operation of the magazine.
(b) Metal magazines shall be equipped with electrical bonding connections between all conductive portions so the entire structure is at the same electrical potential. Suitable electrical bonding methods include welding, riveting, or the use of securely tightened bolts where individual metal portions are joined. Conductive portions of nonmetal magazines shall be grounded.
(c) Electrical switches and outlets shall be located on the outside of the magazine.
§ 56.6133 - Powder chests.
(a) Powder chests (day boxes) shall be—
(1) Structurally sound, weather-resistant, equipped with a lid or cover, and with only nonsparking material on the inside;
(2) Posted with the appropriate United States Department of Transportation placards or other appropriate warning signs that indicate the contents and are visible from each approach;
(3) Located out of the blast area once loading has been completed;
(4) Locked or attended when containing explosive material; and
(5) Emptied at the end of each shift with the contents returned to a magazine or other storage facility, or attended.
(b) Detonators shall be kept in chests separate from explosives or blasting agents, unless separated by 4 inches of hardwood or equivalent, or a laminated partition. When a laminated partition is used, operators must follow the provisions of the Institute of Makers of Explosives (IME) Safety Library Publication No. 22, “Recommendations for the Safe Transportation of Detonators in a Vehicle with Other Explosive Materials” (May 1993), and the “Generic Loading Guide for the IME-22 Container” (October 1993). The IME is located at 1120 19th Street NW., Suite 310, Washington, DC 20036-3605; 202-429-9280; https://www.ime.org. This incorporation by reference has been approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies are available at MSHA's Office of Standards, Regulations, and Variances, 201 12th Street South, Arlington, VA 22202-5452; 202-693-9440; and at all Metal and Nonmetal Mine Safety and Health District Offices, or available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
§ 56.6000 - Definitions.
The following definitions apply in this subpart.
Blasting agent. Any substance classified as a blasting agent by the Department of Transportation in 49 CFR 173.114a(a). This document is available at any MSHA Metal and Nonmetal Safety and Health district office.
Detonating cord. A flexible cord containing a center core of high explosives which may be used to initiate other explosives.
Detonator. Any device containing a detonating charge used to initiate an explosive. These devices include electronic detonators, electric or nonelectric instantaneous or delay blasting caps, and delay connectors. The term “detonator” does not include detonating cord. Detonators may be either “Class A” detonators or “Class C” detonators, as classified by the Department of Transportation in 49 CFR 173.53 and 173.100, which is available at any MSHA Metal and Nonmetal Safety and Health district office.
Flash point. The minimum temperature at which sufficient vapor is released by a liquid to form a flammable vapor-air mixture near the surface of the liquid.
Igniter cord. A fuse that burns progressively along its length with an external flame at the zone of burning, used for lighting a series of safety fuses in a desired sequence.
Magazine. A bullet-resistant, theft-resistant, fire-resistant, weather-resistant, ventilated facility for the storage of explosives and detonators (BATF Type 1 or Type 2 facility).
Misfire. The complete or partial failure of explosive material to detonate as planned. The term also is used to describe the explosive material itself that has failed to detonate.
Primer. A unit, package, or cartridge of explosives which contains a detonator and is used to initiate other explosives or blasting agents.
Safety switch. A switch that provides shunt protection in blasting circuits between the blast site and the switch used to connect a power source to the blasting circuit.
Slurry. An explosive material containing substantial portions of a liquid, oxidizers, and fuel, plus a thickener.
Water gel. An explosive material containing substantial portions of water, oxidizers, and fuel, plus a cross-linking agent.
Transportation
§ 56.6200 - Delivery to storage or blast site areas.
Explosive material shall be transported without undue delay to the storage area or blast site.
§ 56.6201 - Separation of transported explosive material.
Detonators shall not be transported on the same vehicle or conveyance with other explosives except as follows:
(a) Detonators in quantities of more than 1000 may be transported in a vehicle or conveyance with explosives or blasting agents provided the detonators are—
(1) Maintained in the original packaging as shipped from the manufacturer; and
(2) Separated from explosives or blasting agents by 4 inches of hardwood or equivalent, or a laminated partition. The hardwood or equivalent shall be fastened to the vehicle or conveyance. When a laminated partition is used, operators must follow the provisions of the Institute of Makers of Explosives (IME) Safety Library Publication No.22, “Recommendations for the Safe Transportation of Detonators in a Vehicle with Other Explosive Materials” (May 1993), and the “Generic Loading Guide for the IME-22 Container” (October 1993). The IME is located at 1120 19th Street NW., Suite 310, Washington, DC 20036-3605; 202-429-9280; https://www.ime.org. This incorporation by reference has been approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies are available at MSHA's Office of Standards, Regulations, and Variances, 201 12th Street South, Arlington, VA 22202-5452; 202-693-9440; and at all Metal and Nonmetal Mine Safety and Health District Offices, or available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
(b) Detonators in quantities of 1000 or fewer may be transported with explosives or blasting agents provided the detonators are—
(1) Kept in closed containers; and
(2) Separated from explosives or blasting agents by 4 inches of hardwood or equivalent, or a laminated partition. The hardwood or equivalent shall be fastened to the vehicle or conveyance. When a laminated partition is used, operators must follow the provisions of IME Safety Library Publication No. 22, “Recommendations for the Safe Transportation of Detonators in a Vehicle with Other Explosive Materials” (May 1993), and the “Generic Loading Guide for the IME-22 Container” (October 1993). The IME is located at 1120 19th Street NW., Suite 310, Washington, DC 20036-3605; 202-429-9280; https://www.ime.org. This incorporation by reference has been approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies are available at MSHA's Office of Standards, Regulations, and Variances, 201 12th Street South, Arlington, VA 22202-5452; 202-693-9440; and at all Metal and Nonmetal Mine Safety and Health District Offices, or available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
§ 56.6202 - Vehicles.
(a) Vehicles containing explosive material shall be—
(1) Maintained in good condition and shall comply with the requirements of subpart M of this part;
(2) Equipped with sides and enclosures higher than the explosive material being transported or have the explosive material secured to a nonconductive pallet;
(3) Equipped with a cargo space that shall contain the explosive material (passenger areas shall not be considered cargo space);
(4) Equipped with at least two multipurpose dry-chemical fire extinguishers or one such extinguisher and an automatic fire suppression system;
(5) Posted with warning signs that indicate the contents and are visible from each approach;
(6) Occupied only by persons necessary for handling the explosive material;
(7) Attended or the cargo compartment locked, except when parked at the blast site and loading is in progress; and
(8) Secured while parked by having—
(i) The brakes set;
(ii) The wheels chocked if movement could occur; and
(iii) The engine shut off unless powering a device being used in the loading operation.
(b) Vehicles containing explosives shall have—
(1) No sparking material exposed in the cargo space; and
(2) Only properly secured nonsparking equipment in the cargo space with the explosives.
(c) Vehicles used for dispensing bulk explosive material shall—
(1) Have no zinc or copper exposed in the cargo space; and
(2) Provide any enclosed screw-type conveyors with protection against internal pressure and frictional heat.
§ 56.6203 - Locomotives.
Explosive material shall not be transported on a locomotive. When explosive material is hauled by trolley locomotive, covered, electrically insulated cars shall be used.
§ 56.6204 - Hoists.
(a) Before explosive material is transported in hoist conveyances, the hoist operator shall be notified.
(b) Explosive material transported in hoist conveyances shall be placed within a container which prevents shifting of the cargo that could cause detonation of the container by impact or by sparks. The manufacturer's container may be used if secured to a nonconductive pallet. When explosives are transported, they shall be secured so as not to contact any sparking material.
(c) No explosive material shall be transported during a mantrip.
§ 56.6205 - Conveying explosives by hand.
Closed, nonconductive containers shall be used to carry explosives and detonators to and from blast sites. Separate containers shall be used for explosives and detonators.
§ 56.6300 - Control of blasting operations.
(a) Only persons trained and experienced in the handling and use of explosive material shall direct blasting operations and related activities.
(b) Trainees and inexperienced persons shall work only in the immediate presence of persons trained and experienced in the handling and use of explosive material.
§ 56.6301 - Blasthole obstruction check.
Before loading, blastholes shall be checked and, wherever possible, cleared of obstructions.
§ 56.6302 - Separation of explosive material.
Explosives and blasting agents shall be kept separated from detonators until loading begins.
§ 56.6303 - Initiation preparation.
(a) Primers shall be made up only at the time of use and as close to the blast site as conditions allow.
(b) Primers shall be prepared with the detonator contained securely and completely within the explosive or contained securely and appropriately for its design in the tunnel or cap well.
(c) When using detonating cord to initiate another explosive, a connection shall be prepared with the detonating cord threaded through, attached securely to, or otherwise in contact with the explosive.
§ 56.6304 - Primer protection.
(a) Tamping shall not be done directly on a primer.
(b) Rigid cartridges of explosives or blasting agents that are 4 inches (100 millimeters) in diameter or larger shall not be dropped on the primer except where the blasthole contains sufficient depth of water to protect the primer from impact. Slit packages of prill, water gel, or emulsions are not considered rigid cartridges and may be drop loaded.
§ 56.6305 - Unused explosive material.
Unused explosive material shall be moved to a protected location as soon as practical after loading operations are completed.
§ 56.6306 - Loading, blasting, and security.
(a) When explosive materials or initiating systems are brought to the blast site, the blast site shall be attended; barricaded and posted with warning signs, such as “Danger,” “Explosives,” or “Keep Out;” or flagged against unauthorized entry.
(b) Vehicles and equipment shall not be driven over explosive material or initiating systems in a manner which could contact the material or systems, or create other hazards.
(c) Once loading begins, the only activities permitted within the blast site shall be those activities directly related to the blasting operation and the activities of surveying, stemming, sampling of geology, and reopening of holes, provided that reasonable care is exercised. Haulage activity is permitted near the base of a highwall being loaded or awaiting firing, provided no other haulage access exists.
(d) Loading and blasting shall be conducted in a manner designed to facilitate a continuous process, with the blast fired as soon as possible following the completion of loading. If blasting a loaded round may be delayed for more than 72 hours, the operator shall notify the appropriate MSHA district office.
(e) In electric blasting prior to connecting to the power source, and in nonelectric blasting prior to attaching an initiating device, all persons shall leave the blast area except persons in a blasting shelter or other location that protects them from concussion (shock wave), flying material, and gases.
(f) Before firing a blast—
(1) Ample warning shall be given to allow all persons to be evacuated;
(2) Clear exit routes shall be provided for persons firing the round; and
(3) All access routes to the blast area shall be guarded or barricaded to prevent the passage of persons or vehicles.
(g) Work shall not resume in the blast area until a post-blast examination addressing potential blast-related hazards has been conducted by a person with the ability and experience to perform the examination.
§ 56.6307 - Drill stem loading.
Explosive material shall not be loaded into blastholes with drill stem equipment or other devices that could be extracted while containing explosive material. The use of loading hose, collar sleeves, or collar pipes is permitted.
§ 56.6308 - Initiation systems.
Initiation systems shall be used in accordance with the manufacturer's instructions.
§ 56.6309 - Fuel oil requirements for ANFO.
(a) Liquid hydrocarbon fuels with flash points lower than that of No. 2 diesel oil (125 °F) shall not be used to prepare ammonium nitrate-fuel oil, except that diesel fuels with flash points no lower than 100 °F may be used at ambient air temperatures below 45 °F.
(b) Waste oil, including crankcase oil, shall not be used to prepare ammonium nitrate-fuel oil.
§ 56.6310 - Misfire waiting period.
When a misfire is suspected, persons shall not enter the blast area—
(a) For 30 minutes if safety fuse and blasting caps are used;
(b) For 15 minutes if any other type detonators are used; or
(c) For 30 minutes if electronic detonators are used, or for the manufacturer-recommended time, whichever is longer.
§ 56.6311 - Handling of misfires.
(a) Faces and muck piles shall be examined for misfires after each blasting operation.
(b) Only work necessary to remove a misfire and protect the safety of miners engaged in the removal shall be permitted in the affected area until the misfire is disposed of in a safe manner.
(c) When a misfire cannot be disposed of safely, each approach to the area affected by the misfire shall be posted with a warning sign at a conspicuous location to prohibit entry, and the condition shall be reported immediately to mine management.
(d) Misfires occurring during the shift shall be reported to mine management not later than the end of the shift.
§ 56.6312 - Secondary blasting.
Secondary blasts fired at the same time in the same work area shall be initiated from one source.
Electric Blasting
§ 56.6400 - Compatibility of electric detonators.
All electric detonators to be fired in a round shall be from the same manufacturer and shall have similar electrical firing characteristics.
§ 56.6401 - Shunting.
Except during testing—
(a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round;
(b) Wired rounds shall be kept shunted until connected to the blasting line; and
(c) Blasting lines shall be kept shunted until immediately before blasting.
§ 56.6402 - Deenergized circuits near detonators.
Electrical distribution circuits within 50 feet of electric detonators at the blast site shall be deenergized. Such circuits need not be deenergized between 25 to 50 feet of the electric detonators if stray current tests, conducted as frequently as necessary, indicate a maximum stray current of less than 0.05 amperes through a 1-ohm resistor as measured at the blast site.
§ 56.6403 - Branch circuits.
(a) If electric blasting includes the use of branch circuits, each branch shall be equipped with a safety switch or equivalent method to isolate the circuits to be used.
(b) At least one safety switch or equivalent method of protection shall be located outside the blast area and shall be in the open position until persons are withdrawn.
§ 56.6404 - Separation of blasting circuits from power source.
(a) Switches used to connect the power source to a blasting circuit shall be locked in the open position except when closed to fire the blast.
(b) Lead wires shall not be connected to the blasting switch until the shot is ready to be fired.
§ 56.6405 - Firing devices.
(a) Power sources shall be capable of delivering sufficient current to energize all electric detonators to be fired with the type of circuits used. Storage or dry cell batteries are not permitted as power sources.
(b) Blasting machines shall be tested, repaired, and maintained in accordance with manufacturer's instructions.
(c) Only the blaster shall have the key or other control to an electrical firing device.
§ 56.6406 - Duration of current flow.
If any part of a blast is connected in parallel and is to be initiated from powerlines or lighting circuits, the time of current flow shall be limited to a maximum of 25 milliseconds. This can be accomplished by incorporating an arcing control device in the blasting circuit or by interrupting the circuit with an explosive device attached to one or both lead lines and initiated by a 25-millisecond delay electric detonator.
§ 56.6407 - Circuit testing.
A blasting galvanometer or other instrument designed for testing blasting circuits shall be used to test each of the following:
(a) Continuity of each electric or electronic detonator in the blasthole prior to stemming and connection to the blasting line.
(b) Resistance of individual series or the resistance of multiple balanced series to be connected in parallel prior to their connection to the blasting line.
(c) Continuity of blasting lines prior to the connection of electric or electronic detonator series.
(d) Total blasting circuit resistance prior to connection to the power source.
Nonelectric Blasting
§ 56.6500 - Damaged initiating material.
A visual check of the completed circuit shall be made to ensure that the components are properly aligned and connected. Safety fuse, igniter cord, detonating cord, shock or gas tubing, and similar material which is kinked, bent sharply, or damaged shall not be used.
§ 56.6501 - Nonelectric initiation systems.
(a) When the nonelectric initiation system uses shock tube—
(1) Connections with other initiation devices shall be secured in a manner which provides for uninterrupted propagation;
(2) Factory-made units shall be used as assembled and shall not be cut except that a single splice is permitted on the lead-in trunkline during dry conditions; and
(3) Connections between blastholes shall not be made until immediately prior to clearing the blast site when surface delay detonators are used.
(b) When the nonelectric initiation system uses detonating cord—
(1) The line of detonating cord extending out of a blasthole shall be cut from the supply spool immediately after the attached explosive is correctly positioned in the hole;
(2) In multiple row blasts, the trunkline layout shall be designed so that the detonation can reach each blasthole from at least two directions;
(3) Connections shall be tight and kept at right angles to the trunkline;
(4) Detonators shall be attached securely to the side of the detonating cord and pointed in the direction in which detonation is to proceed;
(5) Connections between blastholes shall not be made until immediately prior to clearing the blast site when surface delay detonators are used; and
(6) Lead-in lines shall be manually unreeled if connected to the trunklines at the blast site.
(c) When the nonelectric initiation system uses gas tube, continuity of the circuit shall be tested prior to blasting.
§ 56.6502 - Safety fuse.
(a) The burning rate of each spool of safety fuse to be used shall be measured, posted in locations which will be conspicuous to safety fuse users, and brought to the attention of all persons involved with the blasting operation.
(b) When firing with safety fuse ignited individually using handheld lighters, the safety fuse shall be of lengths which provide at least the minimum burning time for a particular size round, as specified in the following table:
Table E-1—Safety Fuse—Minimum Burning Time
Number of holes in a round | Minimum
burning time | 1 | 2 min. 1 | 2-5 | 2 min. 40 sec. | 6-10 | 3 min. 20 sec. | 11 to 15 | 5 min. |
---|
1 For example, at least a 36-inch length of 40-second-per-foot safety fuse or at least a 48-inch length of 30-second-per-foot safety fuse would have to be used to allow sufficient time to evacuate the area.
(c) Where flyrock might damage exposed safety fuse, the blast shall be timed so that all safety fuses are burning within the blastholes before any blasthole detonates.
(d) Fuse shall be cut and capped in dry locations.
(e) Blasting caps shall be crimped to fuse only with implements designed for that purpose.
(f) Safety fuse shall be ignited only after the primer and the explosive material are securely in place.
(g) Safety fuse shall be ignited only with devices designed for that purpose. Carbide lights, liquefied petroleum gas torches, and cigarette lighters shall not be used to light safety fuse.
(h) At least two persons shall be present when lighting safety fuse, and no one shall light more than 15 individual fuses. If more than 15 holes per person are to be fired, electric initiation systems, igniter cord and connectors, or other nonelectric initiation systems shall be used.
Extraneous Electricity
§ 56.6600 - Loading practices.
If extraneous electricity is suspected in an area where electric detonators are used, loading shall be suspended until tests determine that stray current does not exceed 0.05 amperes through a 1-ohm resister when measured at the location of the electric detonators. If greater levels of extraneous electricity are found, the source shall be determined and no loading shall take place until the condition is corrected.
§ 56.6601 - Grounding.
Electric blasting circuits, including powerline sources when used, shall not be grounded.
§ 56.6602 - Static electricity dissipation during loading.
When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard—
(a) An evaluation of the potential static electricity hazard shall be made and any hazard shall be eliminated before loading begins;
(b) The loading hose shall be of a semiconductive type, have a total of not more than 2 megohms of resistance over its entire length and not less than 1000 ohms of resistance per foot;
(c) Wire-countered hoses shall not be used;
(d) Conductive parts of the loading equipment shall be bonded and grounded and grounds shall not be made to other potential sources of extraneous electricity; and
(e) Plastic tubes shall not be used as hole liners if the hole contains an electric detonator.
§ 56.6603 - Air gap.
At least a 15-foot air gap shall be provided between the blasting circuit and the electric power source.
§ 56.6604 - Precautions during storms.
During the approach and progress of an electrical storm, blasting operations shall be suspended and persons withdrawn from the blast area or to a safe location.
§ 56.6605 - Isolation of blasting circuits.
Lead wires and blasting lines shall be isolated and insulated from power conductors, pipelines, and railroad tracks, and shall be protected from sources of stray or static electricity. Blasting circuits shall be protected from any contact between firing lines and overhead powerlines which could result from the force of a blast.
Equipment/Tools
§ 56.6700 - Nonsparking tools.
Only nonsparking tools shall be used to open containers of explosive material or to punch holes in explosive cartridges.
§ 56.6701 - Tamping and loading pole requirements.
Tamping and loading poles shall be of wood or other nonconductive, nonsparking material. Couplings for poles shall be nonsparking.
Maintenance
§ 56.6800 - Storage facilities.
When repair work which could produce a spark or flame is to be performed on a storage facility—
(a) The explosive material shall be moved to another facility, or moved at least 50 feet from the repair activity and monitored; and
(b) The facility shall be cleaned to prevent accidental detonation.
§ 56.6801 - Vehicle repair.
Vehicles containing explosive material and oxidizers shall not be taken into a repair garage or shop.
§ 56.6802 - Bulk delivery vehicles.
No welding or cutting shall be performed on a bulk delivery vehicle until the vehicle has been washed down and all explosive material has been removed. Before welding or cutting on a hollow shaft, the shaft shall be thoroughly cleaned inside and out and vented with a minimum 1/2-inch diameter opening to allow for sufficient ventilation.
§ 56.6803 - Blasting lines.
Permanent blasting lines shall be properly supported. All blasting lines shall be insulated and kept in good repair.
General Requirements
§ 56.6900 - Damaged or deteriorated explosive material.
Damaged or deteriorated explosive material shall be disposed of in a safe manner in accordance with the instructions of the manufacturer.
§ 56.6901 - Black powder.
(a) Black powder shall be used for blasting only when a desired result cannot be obtained with another type of explosive, such as in quarrying certain types of dimension stone.
(b) Containers of black powder shall be—
(1) Nonsparking;
(2) Kept in a totally enclosed cargo space while being transported by a vehicle;
(3) Securely closed at all times when—
(i) Within 50 feet of any magazine or open flame;
(ii) Within any building in which a fuel-fired or exposed-element electric heater is operating; or
(iii) In an area where electrical or incandescent-particle sparks could result in powder ignition; and
(4) Opened only when the powder is being transferred to a blasthole or another container and only in locations not listed in paragraph (b)(3) of this section.
(c) Black powder shall be transferred from containers only by pouring.
(d) Spills shall be cleaned up promptly with nonsparking equipment. Contaminated powder shall be put into a container of water and shall be disposed of promptly after the granules have disintegrated, or the spill area shall be flushed promptly with water until the granules have disintegrated completely.
(e) Misfires shall be disposed of by washing the stemming and powder charge from the blasthole, and removing and disposing of the initiator in accordance with the requirement for damaged explosives.
(f) Holes shall not be reloaded for at least 12 hours when the blastholes have failed to break as planned.
§ 56.6902 - Excessive temperatures.
(a) Where heat could cause premature detonation, explosive material shall not be loaded into hot areas, such as kilns or sprung holes.
(b) When blasting sulfide ores where hot holes occur that may react with explosive material in blastholes, operators shall—
(1) Measure an appropriate number of blasthole temperatures in order to assess the specific mine conditions prior to the introduction of explosive material;
(2) Limit the time between the completion of loading and the initiation of the blast to no more than 12 hours; and
(3) Take other special precautions to address the specific conditions at the mine to prevent premature detonation.
§ 56.6903 - Burning explosive material.
If explosive material is suspected of burning at the blast site, persons shall be evacuated from the endangered area and shall not return for at least one hour after the burning or suspected burning has stopped.
§ 56.6904 - Smoking and open flames.
Smoking and use of open flames shall not be permitted within 50 feet of explosive material except when separated by permanent noncombustible barriers. This standard does not apply to devices designed to ignite safety fuse or to heating devices which do not create a fire or explosion hazard.
§ 56.6905 - Protection of explosive material.
(a) Explosive material shall be protected from temperatures in excess of 150 degrees Fahrenheit.
(b) Explosive material shall be protected from impact, except for tamping and dropping during loading.