Collapse to view only § 52.725 - Control strategy: Particulates.

§ 52.719 - [Reserved]

§ 52.720 - Identification of plan.

(a) Purpose and scope. This section sets forth the applicable State implementation plan for the State of Illinois under section 110 of the Clean Air Act, 42 U.S.C. 7401-7671q and 40 CFR part 51 to meet national ambient air quality standards.

(b) Incorporation by reference. (1) Material listed in paragraphs (c) and (d) of this section with an EPA approval date prior to December 31, 2016, was approved for incorporation by reference by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Entries in paragraphs (c) and (d) of this section with the EPA approval dates after December 31, 2016, have been approved by EPA for inclusion in the State implementation plan and for incorporation by reference into the plan as it is contained in this section, and will be considered by the Director of the Federal Register for approval in the next update to the SIP compilation.

(2) EPA Region 5 certifies that the materials provided by EPA at the addresses in paragraph (b)(3) of this section are an exact duplicate of the officially promulgated state rules/regulations which have been approved as part of the state implementation plan as of the dates referenced in paragraph (b)(1).

(3) Copies of the materials incorporated by reference may be inspected at the Environmental Protection Agency, Region 5, Air Programs Branch, 77 West Jackson Boulevard, Chicago, IL 60604, or the National Archives and Records Administration. For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.

(c) EPA approved regulations.

EPA-Approved Illinois Regulations and Statutes

Illinois citation Title/subject State
effective
date
EPA approval date Comments Title 35 of the Illinois Administrative CodeSubtitle A: General ProvisionsChapter I: Pollution Control BoardPart 101: General Rules—Subpart A: General Provisions101.112Bias and Conflict of Interest7/5/20179/23/2019, 84 FR 49671Only paragraph (d). Part 106: Procedural RegulationsSubpart E: Alternative Opacity Procedures106.501Scope and Applicability7/13/198812/29/1992, 57 FR 61834 106.502Joint or Single Petition7/13/198812/29/1992, 57 FR 61834 106.503Request to Agency to Join as Co-Petitioner7/13/198812/29/1992, 57 FR 61834 106.504Contents of Petition7/13/198812/29/1992, 57 FR 61834 106.505Response and Reply7/13/198812/29/1992, 57 FR 61834 106.506Notice and Conduct of Hearing6/5/199012/29/1992, 57 FR 61834 106.507Opinions and Orders7/13/198812/29/1992, 57 FR 61834 Subpart J: Culpability Determinations106.930Applicability7/11/19947/13/1995, 60 FR 36060 106.931Petition for Review7/11/19947/13/1995, 60 FR 36060 106.932Response and Reply7/11/19947/13/1995, 60 FR 36060 106.933Notice and Hearing7/11/19947/13/1995, 60 FR 36060 106.934Opinion and Order7/11/19947/13/1995, 60 FR 36060 Subtitle B: Air PollutionChapter I: Pollution Control BoardSubchapter a: Permits and General ProvisionsPart 201: Permits and General ProvisionsSubpart A: Definitions201.102Definitions4/14/19725/31/1972, 37 FR 10862Approved as Rule 101. Subpart B: General Provisions201.121Existence of Permit No Defense4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(h). 201.122Proof of Emissions4/14/19725/31/1972, 37 FR 10862Approved as Rule 108. 201.123Burden of Persuasion Regarding Exceptions4/14/19725/31/1972, 37 FR 10862Approved as Rule 111. 201.124Annual Report4/14/19725/31/1972, 37 FR 10862Approved as Rule 112. 201.125Severability4/14/19725/31/1972, 37 FR 10862Approved as Rule 113. 201.126Repealer4/14/19725/31/1972, 37 FR 10862Approved as Rule 114. Subpart C: Prohibitions201.141Prohibition of Air Pollution4/14/19725/31/1972, 37 FR 10862Approved as Rule 102. 201.142Construction Permit Required4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(a)(1). 201.143Operating Permits for New Sources4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(b)(1). 201.144Operating Permits for Existing Sources4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(b)(2). 201.146Exemptions From State Permit Requirements3/24/201710/10/2018, 83 FR 50854Except (mmm). 201.147Former Permits4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(j). 201.148Operation Without Compliance Program and Project Completion Schedule4/14/19725/31/1972, 37 FR 10862Approved as Rule 104(a). 201.149Operation During Malfunction, Breakdown or Startups4/14/19725/31/1972, 37 FR 10862Approved as Rule 105(a). 201.150Circumvention4/14/19725/31/1972, 37 FR 10862Approved as Rule 109. 201.151Design of Effluent Exhaust Systems4/14/19725/31/1972, 37 FR 10862Approved as Rule 110. Subpart D: Permit Applications and Review Process201.152Contents of Application for Construction Permit6/23/19981/3/2000, 65 FR 14 201.156Conditions4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(a)(6). 201.157Contents of Application for Operating Permit6/23/19981/3/2000, 65 FR 14 201.158Incomplete Applications6/23/19981/3/2000, 65 FR 14 201.159Signatures6/23/19981/3/2000, 65 FR 14 201.160Standards for Issuance6/23/19981/3/2000, 65 FR 14 201.161Conditions4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(b)(7). 201.162Duration12/1/20104/7/2014, 79 FR 18997 201.163Joint Construction and Operating Permits6/23/19981/3/2000, 65 FR 14 201.164Design Criteria6/23/19981/3/2000, 65 FR 14 201.165Hearings4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(e). 201.166Revocation4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(f). 201.167Revisions to Permits4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(g). 201.168Appeals From Conditions4/14/19725/31/1972, 37 FR 10862Approved as Rule 103(k). Subpart F: CAAPP Permits201.207Applicability6/23/19981/3/2000, 65 FR 14 Subpart H: Compliance Programs and Project Completion Schedules201.241Contents of Compliance Program4/14/19725/31/1972, 37 FR 10862Approved as Rule 104(b)(1). 201.242Contents of Project Completion Schedule4/14/19725/31/1972, 37 FR 10862Approved as Rule 104(b)(2, 3). 201.243Standards for Approval4/14/19725/31/1972, 37 FR 10862Approved as Rule 104(c). 201.244Revisions4/14/19725/31/1972, 37 FR 10862Approved as Rule 104(d). 201.245Effects of Approval4/14/19725/31/1972, 37 FR 10862Approved as Rule 104(e). 201.246Records and Reports4/14/19725/31/1972, 37 FR 10862Approved as Rule 104(f). Subpart I: Malfunctions, Breakdowns or Startups201.261Contents of Request for Permission To Operate During a Malfunction, Breakdown or Startup4/14/19725/31/1972, 37 FR 10862Approved as Rule 105(b). 201.262Standards for Granting Permission To Operate During a Malfunction, Breakdown or Startup4/14/19725/31/1972, 37 FR 10862Approved as Rule 105(c). 201.263Records and Reports4/14/19725/31/1972, 37 FR 10862Approved as Rule 105(d). 201.264Continued Operation or Startup Prior to Granting of Operating Permit4/14/19725/31/1972, 37 FR 10862Approved as Rule 105(e). 201.265Effect of Granting of Permission To Operate During a Malfunction, Breakdown or Startup4/14/19725/31/1972, 37 FR 10862Approved as Rule 105(f). Subpart J: Monitoring and Testing201.281Permit Monitoring Equipment Requirements2/3/19894/6/1993, 58 FR 17780 201.282Testing4/14/19725/31/1972, 37 FR 10862Approved as Rule 106(b). 201.283Records and Reports4/14/19725/31/1972, 37 FR 10862Approved as Rule 106(c). Subpart K: Records and Reports201.301Records4/14/19725/31/1972, 37 FR 10862Approved as Rule 107(a). 201.302Reports12/23/20133/13/2015, 80 FR 13248 Subpart L: Continuous Monitoring201.401Continuous Monitoring Requirements2/3/19894/6/1993, 58 FR 17780 201.402Alternative Monitoring2/3/19894/6/1993, 58 FR 17780 201.403Exempt Sources2/3/19894/6/1993, 58 FR 17780 201.404Monitoring System Malfunction2/3/19894/6/1993, 58 FR 17780 201.405Excess Emission Reporting2/3/19894/6/1993, 58 FR 17780 201.406Data Reduction2/3/19894/6/1993, 58 FR 17780 201.407Retention of Information2/3/19894/6/1993, 58 FR 17780 201.408Compliance Schedules2/3/19894/6/1993, 58 FR 17780 Subpart M: Permit By Rule (PBR)—General Provisions201.500Purpose3/24/201710/10/2018, 83 FR 50854 201.505Applicability3/24/201710/10/2018, 83 FR 50854 201.510Notice of Intent to Be Covered By a PBR (Notification)3/24/201710/10/2018, 83 FR 50854 201.515Commencing Construction or Modification3/24/201710/10/2018, 83 FR 50854 201.520Modification or Change in Status of an Emission Unit Covered by a PBR3/24/201710/10/2018, 83 FR 50854 201.525Standard Conditions for PBR3/24/201710/10/2018, 83 FR 50854 201.530Recordkeeping and Reporting3/24/201710/10/2018, 83 FR 50854 201.535Authority to Operate3/24/201710/10/2018, 83 FR 50854 201.540Enforcement Authority3/24/201710/10/2018, 83 FR 50854 Subpart N: Permit By Rule (PBR)—Boilers Less Than Or Equal To 100 MMBtu/hr201.600Applicability3/24/201710/10/2018, 83 FR 50854 201.605Boiler Notice of Intent to Be Covered by a PBR (Notification) 201.6103/24/201710/10/2018, 83 FR 50854 201.615Opacity Requirements3/24/201710/10/2018, 83 FR 50854 201.620Requirements for Use of Diesel Fuel and Refinery Fuel Gas 201.6253/24/201710/10/2018, 83 FR 50854 201.625Carbon Monoxide (CO) Requirements3/24/201710/10/2018, 83 FR 50854 201.630Nitrogen Oxide (NOX) Requirements3/24/201710/10/2018, 83 FR 50854 201.635PBR Boiler Reporting Requirements3/24/201710/10/2018, 83 FR 50854 Part 203: Major Stationary Sources Construction and ModificationSubpart A: General Provisions203.101Definitions4/30/19939/27/1995, 60 FR 49778 203.103Actual Construction3/22/198812/17/1992, 57 FR 59928 203.104Actual Emissions3/22/198812/17/1992, 57 FR 59928 203.107Allowable Emissions4/30/19939/27/1995, 60 FR 49778 203.110Available Growth Margin4/30/19939/27/1995, 60 FR 49778 203.112Building, Structure and Facility4/30/19939/27/1995, 60 FR 49778 203.113Commence3/22/198812/17/1992, 57 FR 59928 203.116Construction3/22/198812/17/1992, 57 FR 59928 203.117Dispersion Enhancement Techniques3/22/198812/17/1992, 57 FR 59928 203.119Emission Baseline7/22/198312/17/1992, 57 FR 59928 203.121Emission Offset4/30/19939/27/1995, 60 FR 49778 203.122Emissions Unit4/30/19939/27/1995, 60 FR 49778 203.123Federally Enforceable4/30/19939/27/1995, 60 FR 49778 203.124Fugitive Emissions3/22/198812/17/1992, 57 FR 59928 203.125Installation3/22/198812/17/1992, 57 FR 59928 203.126Lowest Achievable Emission Rate4/30/19939/27/1995, 60 FR 49778 203.127Nonattainment Area3/22/198812/17/1992, 57 FR 59928 203.128Potential To Emit4/30/19939/27/1995, 60 FR 49778 203.131Reasonable Further Progress3/22/198812/17/1992, 57 FR 59928 203.134Secondary Emissions3/22/198812/17/1992, 57 FR 59928 203.136Stationary Source3/22/198812/17/1992, 57 FR 59928 203.150Public Participation4/30/19939/27/1995, 60 FR 49778 Subpart B: Major Stationary Sources in Nonattainment Areas203.201Prohibition4/30/19939/27/1995, 60 FR 49778 203.202Coordination With Permit Requirement and Application Pursuant to 35 Ill. Adm. Code 2013/22/198812/17/1992, 57 FR 59928 203.203Construction Permit Requirement and Application4/30/19939/27/1995, 60 FR 49778 203.205Effect of Permits3/22/198812/17/1992, 57 FR 59928 203.206Major Stationary Source3/10/19985/13/2003, 68 FR 25504 203.207Major Modification of a Source9/4/20209/9/2021, 86 FR 50459 203.208Net Emission Determination4/30/19939/27/1995, 60 FR 49778 203.209Significant Emissions Determination4/30/19939/27/1995, 60 FR 49778 203.210Relaxation of a Source-Specific Limitation3/22/198812/17/1992, 57 FR 59928 203.211Permit Exemption Based on Fugitive Emissions3/22/198812/17/1992, 57 FR 59928 Subpart C: Requirements for Major Stationary Sources in Nonattainment Areas203.301Lowest Achievable Emission Rate3/10/19985/13/2003, 68 FR 25504 203.302Maintenance of Reasonable Further Progress and Emission Offsets4/30/19939/27/1995, 60 FR 49778 203.303Baseline and Emission Offsets Determination4/30/19939/27/1995, 60 FR 49778 203.305Compliance by Existing Sources3/22/198812/17/1992, 57 FR 59928 203.306Analysis of Alternatives4/30/19939/27/1995, 60 FR 49778 Subpart F: Operation of a Major Stationary Source or Major Modification203.601Lowest Achievable Emission Rate Compliance Requirement3/22/198812/17/1992, 57 FR 59928 203.602Emission Offset Maintenance Requirement3/22/198812/17/1992, 57 FR 59928 Subpart G: General Maintenance of Emission Offsets203.701General Maintenance of Emission Offsets3/22/198812/17/1992, 57 FR 59928 Subpart H: Offsets for Emission Increases From Rocket Engines and Motor Firing203.801Offsetting by Alternative or Innovative Means5/14/19939/27/1995, 60 FR 49778 Part 204: Prevention of Significant DeteriorationSubpart A: General Provisions204.100Incorporations by Reference9/4/20209/9/2021, 86 FR 50459 204.110Abbreviations and Acronyms9/4/20209/9/2021, 86 FR 50459 204.120Severability9/4/20209/9/2021, 86 FR 50459 Subpart B: Definitions204.200Definitions9/4/20209/9/2021, 86 FR 50459 204.210Actual Emissions9/4/20209/9/2021, 86 FR 50459 204.220Adverse Impact on Visibility9/4/20209/9/2021, 86 FR 50459 204.230Allowable Emissions9/4/20209/9/2021, 86 FR 50459 204.240Baseline Actual Emissions9/4/20209/9/2021, 86 FR 50459 204.250Baseline Area9/4/20209/9/2021, 86 FR 50459 204.260Baseline Concentration9/4/20209/9/2021, 86 FR 50459 204.270Begin Actual Construction9/4/20209/9/2021, 86 FR 50459 204.280Best Available Control Technology (BACT)9/4/20209/9/2021, 86 FR 50459 204.290Building, Structure, Facility, or Installation9/4/20209/9/2021, 86 FR 50459 204.300Clean Coal Technology9/4/20209/9/2021, 86 FR 50459 204.310Clean Coal Technology Demonstration Project9/4/20209/9/2021, 86 FR 50459 204.320Commence9/4/20209/9/2021, 86 FR 50459 204.330Complete9/4/20209/9/2021, 86 FR 50459 204.340Construction9/4/20209/9/2021, 86 FR 50459 204.350Dispersion Technique9/4/20209/9/2021, 86 FR 50459 204.360Electric Utility Steam Generating Unit9/4/20209/9/2021, 86 FR 50459 204.370Emissions Unit9/4/20209/9/2021, 86 FR 50459 204.380Excessive Concentration9/4/20209/9/2021, 86 FR 50459 204.390Federal Land Manager9/4/20209/9/2021, 86 FR 50459 204.400Federally Enforceable9/4/20209/9/2021, 86 FR 50459 204.410Fugitive Emissions9/4/20209/9/2021, 86 FR 50459 204.420Good Engineering Practice9/4/20209/9/2021, 86 FR 50459 204.430Greenhouse Gases (GHGs)9/4/20209/9/2021, 86 FR 50459 204.440High Terrain9/4/20209/9/2021, 86 FR 50459 204.450Indian Reservation9/4/20209/9/2021, 86 FR 50459 204.460Indian Governing Body9/4/20209/9/2021, 86 FR 50459 204.470Innovative Control Technology9/4/20209/9/2021, 86 FR 50459 204.480Low Terrain9/4/20209/9/2021, 86 FR 50459 204.490Major Modification9/4/20209/9/2021, 86 FR 50459 204.500Major Source Baseline Date9/4/20209/9/2021, 86 FR 50459 204.510Major Stationary Source9/4/20209/9/2021, 86 FR 50459 204.520Minor Source Baseline Date9/4/20209/9/2021, 86 FR 50459 204.530Nearby9/4/20209/9/2021, 86 FR 50459 204.540Necessary Preconstruction Approvals or Permits9/4/20209/9/2021, 86 FR 50459 204.550Net Emissions Increase9/4/20209/9/2021, 86 FR 50459 204.560Potential to Emit9/4/20209/9/2021, 86 FR 50459 204.570Prevention of Significant Deterioration (PSD) Permit9/4/20209/9/2021, 86 FR 50459 204.580Process Unit9/4/20209/9/2021, 86 FR 50459 204.590Project9/4/20209/9/2021, 86 FR 50459 204.600Projected Actual Emissions9/4/20209/9/2021, 86 FR 50459 204.610Regulated NSR Pollutant9/4/20209/9/2021, 86 FR 50459 204.620Replacement Unit9/4/20209/9/2021, 86 FR 50459 204.630Repowering9/4/20209/9/2021, 86 FR 50459 204.640Reviewing Authority9/4/20209/9/2021, 86 FR 50459 204.650Secondary Emissions9/4/20209/9/2021, 86 FR 50459 204.660Significant9/4/20209/9/2021, 86 FR 50459 204.670Significant Emissions Increase9/4/20209/9/2021, 86 FR 50459 204.680Stack in Existence9/4/20209/9/2021, 86 FR 50459 204.690Stationary Source9/4/20209/9/2021, 86 FR 50459 204.700Subject to Regulation9/4/20209/9/2021, 86 FR 50459 204.710Temporary Clean Coal Technology Demonstration Project9/4/20209/9/2021, 86 FR 50459 Subpart C: Major Stationary Sources in Attainment and Unclassifiable Areas204.800Applicability9/4/20209/9/2021, 86 FR 50459 204.810Source Information9/4/20209/9/2021, 86 FR 50459 204.820Source Obligation9/4/20209/9/2021, 86 FR 50459 204.830Permit Expiration9/4/20209/9/2021, 86 FR 50459 204.840Effect of Permits9/4/20209/9/2021, 86 FR 50459 204.850Relaxation of a Source-Specific Limitation9/4/20209/9/2021, 86 FR 50459 204.860Exemptions9/4/20209/9/2021, 86 FR 50459 Subpart D: Increment204.900Ambient Air Increments9/4/20209/9/2021, 86 FR 50459 204.910Ambient Air Ceilings9/4/20209/9/2021, 86 FR 50459 204.920Restrictions on Area Classifications9/4/20209/9/2021, 86 FR 50459 204.930Redesignation9/4/20209/9/2021, 86 FR 50459 Subpart E: Stack Heights204.1000Stack Heights9/4/20209/9/2021, 86 FR 50459 Subpart F: Requirements for Major Stationary Sources and Major Modifications in Attainment and Unclassifiable Areas204.1100Control Technology Review9/4/20209/9/2021, 86 FR 50459 204.1110Source Impact Analysis9/4/20209/9/2021, 86 FR 50459 204.1120Air Quality Models9/4/20209/9/2021, 86 FR 50459 204.1130Air Quality Analysis9/4/20209/9/2021, 86 FR 50459 204.1140Additional Impact Analyses9/4/20209/9/2021, 86 FR 50459 Subpart G: Additional Requirements for Class I Areas204.1200Additional Requirements for Sources Impacting Federal Class I Areas9/4/20209/9/2021, 86 FR 50459 Subpart H: General Obligations of the Illinois Environmental Protection Agency204.1300Notification of Application Completeness to Applicants9/4/20209/9/2021, 86 FR 50459 204.1310Transmittal of Application to USEPA9/4/20209/9/2021, 86 FR 50459 204.1320Public Participation9/4/20209/9/2021, 86 FR 50459 204.1330Issuance Within One Year of Submittal of Complete Application9/4/20209/9/2021, 86 FR 50459 204.1340Permit Rescission9/4/20209/9/2021, 86 FR 50459 Subpart I: Nonapplicability Recordkeeping and Reporting204.1400Recordkeeping and Reporting Requirements for Certain Projects at Major Stationary Sources9/4/20209/9/2021, 86 FR 50459 Subpart J: Innovative Control Technology204.1500Innovative Control Technology9/4/20209/9/2021, 86 FR 50459 Subpart K: Plantwide Applicability Limitation204.1600Applicability9/4/20209/9/2021, 86 FR 50459 204.1610Definitions9/4/20209/9/2021, 86 FR 50459 204.1620Actuals PAL9/4/20209/9/2021, 86 FR 50459 204.1630Allowable Emissions9/4/20209/9/2021, 86 FR 50459 204.1640Continuous Emissions Monitoring System (CEMS)9/4/20209/9/2021, 86 FR 50459 204.1650Continuous Emissions Rate Monitoring System (CERMS)9/4/20209/9/2021, 86 FR 50459 204.1660Continuous Parameter Monitoring System (CPMS)9/4/20209/9/2021, 86 FR 50459 204.1670Lowest Achievable Emission Rate (LAER)9/4/20209/9/2021, 86 FR 50459 204.1680Major Emissions Unit9/4/20209/9/2021, 86 FR 50459 204.1690Plantwide Applicability Limitation (PAL)9/4/20209/9/2021, 86 FR 50459 204.1700PAL Effective Date9/4/20209/9/2021, 86 FR 50459 204.1710PAL Effective Period9/4/20209/9/2021, 86 FR 50459 204.1720PAL Major Modification9/4/20209/9/2021, 86 FR 50459 204.1730PAL Permit9/4/20209/9/2021, 86 FR 50459 204.1740PAL Pollutant9/4/20209/9/2021, 86 FR 50459 204.1750Predictive Emissions Monitoring System (PEMS)9/4/20209/9/2021, 86 FR 50459 204.1760Reasonably Achievable Control Technology (RACT)9/4/20209/9/2021, 86 FR 50459 204.1770Significant Emissions Unit9/4/20209/9/2021, 86 FR 50459 204.1780Small Emissions Unit9/4/20209/9/2021, 86 FR 50459 204.1790Permit Application Requirements9/4/20209/9/2021, 86 FR 50459 204.1800General Requirements for Establishing PAL9/4/20209/9/2021, 86 FR 50459 204.1810Public Participation Requirements9/4/20209/9/2021, 86 FR 50459 204.1820Setting the 10-Year Actuals PAL Level9/4/20209/9/2021, 86 FR 50459 204.1830Contents of the PAL Permit9/4/20209/9/2021, 86 FR 50459 204.1840Effective Period and Reopening a PAL Permit9/4/20209/9/2021, 86 FR 50459 204.1850Expiration of a PAL9/4/20209/9/2021, 86 FR 50459 204.1860Renewal of a PAL9/4/20209/9/2021, 86 FR 50459 204.1870Increasing the PAL During the PAL Effective Period9/4/20209/9/2021, 86 FR 50459 204.1880Monitoring Requirements9/4/20209/9/2021, 86 FR 50459 204.1890Recordkeeping Requirements9/4/20209/9/2021, 86 FR 50459 204.1900Reporting and Notification Requirements9/4/20209/9/2021, 86 FR 50459 204.1910Transition Requirements9/4/20209/9/2021, 86 FR 50459 Subchapter c: Emission Standards and Limitations for Stationary SourcesPart 211: Definitions and General ProvisionsSubpart A: General Provisions211.101Incorporations by Reference1/28/201310/6/2014, 79 FR 60070 211.102Abbreviations and Conversion Factors9/14/20103/23/2012, 77 FR 16940 Subpart B: Definitions211.121Other Definitions9/27/19939/9/1994, 59 FR 46562 211.125Ablative Coating3/4/20214/11/2023, 88 FR 21490 211.130Accelacota9/27/19939/9/1994, 59 FR 46562 211.150Accumulator9/27/19939/9/1994, 59 FR 46562 211.170Acid Gases9/27/19939/9/1994, 59 FR 46562 211.200Acrylonitrile Butadiene Styrene (ABS) Welding9/14/20103/23/2012, 77 FR 16940 211.210Actual Heat Input9/27/19939/9/1994, 59 FR 46562 211.230Adhesive9/27/19939/9/1994, 59 FR 46562 211.233Adhesion Primer9/14/20103/23/2012, 77 FR 16940 211.234Adhesive Bonding Primer3/4/20214/11/2023, 88 FR 21490 211.235Adhesive Primer9/14/20103/23/2012, 77 FR 16940 211.240Adhesion Promoter5/9/19957/25/1996, 61 FR 38577 211.245Adhesion Promoter for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.250Aeration9/27/19939/9/1994, 59 FR 46562 211.260Aerosol Adhesive and Adhesive Primer9/14/20103/23/2012, 77 FR 16940 211.270Aerosol Can Filling Line1/18/199410/21/1996, 61 FR 54556 211.271Aerosol Coating3/4/20214/11/2023, 88 FR 21490 211.272Aerospace Coating3/4/20214/11/2023, 88 FR 21490 211.273Aerospace Coating Operation3/4/20214/11/2023, 88 FR 21490 211.275Aerospace Flexible Primer3/4/20214/11/2023, 88 FR 21490 211.277Aerospace Facility3/4/20214/11/2023, 88 FR 21490 211.278Aerospace Pretreatment Coating3/4/20214/11/2023, 88 FR 21490 211.280Aerospace Primer3/4/20214/11/2023, 88 FR 21490 211.284Aerospace Specialty Coating3/4/20214/11/2023, 88 FR 21490 211.289Aerospace Vehicle or Component3/4/20214/11/2023, 88 FR 21490 211.290Afterburner9/27/19939/9/1994, 59 FR 46562 211.300Aircraft Fluid Systems3/4/20214/11/2023, 88 FR 21490 211.303Aircraft Transparancies3/4/20214/11/2023, 88 FR 21490 211.310Air Contaminant9/27/19939/9/1994, 59 FR 46562 211.330Air Dried Coatings9/27/19939/9/1994, 59 FR 46562 211.350Air Oxidation Process9/27/19939/9/1994, 59 FR 46562 211.370Air Pollutant9/27/19939/9/1994, 59 FR 46562 211.390Air Pollution9/27/19939/9/1994, 59 FR 46562 211.410Air Pollution Control Equipment9/27/19939/9/1994, 59 FR 46562 211.430Air Suspension Coater/Dryer9/27/19939/9/1994, 59 FR 46562 211.450Airless Spray9/27/19939/9/1994, 59 FR 46562 211.470Air Assisted Airless Spray9/27/19939/9/1994, 59 FR 46562 211.474Alcohol5/9/199511/8/1995, 60 FR 56238 211.481Ammunition Sealant9/14/20103/23/2012, 77 FR 16940 211.490Annual Grain Through Put9/27/19939/9/1994, 59 FR 46562 211.491Antichafe Coating3/4/20214/11/2023, 88 FR 21490 211.492Antifoulant Coating9/14/20103/23/2012, 77 FR 16940 211.493Antifouling Sealer/Tie Coat7/27/20113/23/2012, 77 FR 16940 211.495Anti-Glare/Safety Coating5/9/19957/25/1996, 61 FR 38577 211.500Antique Aerospace Vehicle or Component3/4/20214/11/2023, 88 FR 21490 211.510Application Area9/27/19939/9/1994, 59 FR 46562 211.520Aqueous Cleaning Solvent3/4/20214/11/2023, 88 FR 21490 211.530Architectural Coating9/27/19939/9/1994, 59 FR 46562 211.540Architectural Structure9/14/20103/23/2012, 77 FR 16940 211.550As Applied9/27/19939/9/1994, 59 FR 46562 211.560As-Applied Fountain Solution5/9/199511/8/1995, 60 FR 56238 211.570Asphalt9/27/19939/9/1994, 59 FR 46562 211.590Asphalt Prime Coat9/27/19939/9/1994, 59 FR 46562 211.610Automobile9/27/19939/9/1994, 59 FR 46562 211.630Automobile or Light Duty Truck Assembly Source or Automobile or Light Duty Truck Manufacturing Plant9/27/19939/9/1994, 59 FR 46562 211.650Automobile or Light Duty Truck Refinishing9/27/19939/9/1994, 59 FR 46562 211.660Automotive/Transportation Plastic Parts5/9/199510/26/1995, 60 FR 54807 211.670Baked Coatings5/9/199510/26/1995, 60 FR 54807 211.685Basecoat/Clearcoat System5/9/19957/25/1996, 61 FR 38577 211.690Batch Loading9/27/19939/9/1994, 59 FR 46562 211.695Batch Operation5/22/19954/2/1996, 61 FR 14484 211.696Batch Process Train5/22/19954/2/1996, 61 FR 14484 211.710Bead Dipping9/27/19939/9/1994, 59 FR 46562 211.712Bearing Coating3/4/20214/11/2023, 88 FR 21490 211.715Bedliner9/14/20103/23/2012, 77 FR 16940 211.730Binders9/27/19939/9/1994, 59 FR 46562 211.735Black Coating9/14/20103/23/2012, 77 FR 16940 211.737Bonding Maskant3/4/20214/11/2023, 88 FR 21490 211.740Brakehorsepower (rated-bhp)9/25/20076/26/2009, 74 FR 30466 211.750British Thermal Unit9/27/19939/9/1994, 59 FR 46562 211.770Brush or Wipe Coating9/27/19939/9/1994, 59 FR 46562 211.790Bulk Gasoline Plant9/27/19939/9/1994, 59 FR 46562 211.810Bulk Gasoline Terminal9/27/19939/9/1994, 59 FR 46562 211.820Business Machine Plastic Parts9/14/20103/23/2012, 77 FR 16940 211.825Camouflage Coating9/14/20103/23/2012, 77 FR 16940 211.830Can9/27/19939/9/1994, 59 FR 46562 211.850Can Coating9/27/19939/9/1994, 59 FR 46562 211.870Can Coating Line9/27/19939/9/1994, 59 FR 46562 211.880Cap Sealant9/14/20103/23/2012, 77 FR 16940 211.890Capture9/27/19939/9/1994, 59 FR 46562 211.910Capture Device9/27/19939/9/1994, 59 FR 46562 211.930Capture Efficiency9/27/19939/9/1994, 59 FR 46562 211.950Capture System9/27/19939/9/1994, 59 FR 46562 211.954Cavity Wax9/14/20103/23/2012, 77 FR 16940 211.955Cement3/15/200111/8/2001, 66 FR 56449 211.960Cement Kiln3/15/200111/8/2001, 66 FR 56449 211.965Ceramic Tile Installation Adhesive9/14/20103/23/2012, 77 FR 16940 211.970Certified Investigation9/27/19939/9/1994, 59 FR 46562 211.975Chemical Agent-Resistant Coating3/4/20214/11/2023, 88 FR 21490 211.980Chemical Manufacturing Process Unit5/9/19953/23/1998, 63 FR 13784 211.985Chemical Milling Maskant3/4/20214/11/2023, 88 FR 21490 211.990Choke Loading9/27/19939/9/1994, 59 FR 46562 211.1000Class II Finish6/25/20103/23/2012, 77 FR 16940 211.1010Clean Air Act9/27/19939/9/1994, 59 FR 46562 211.1050Cleaning and Separating Operation9/27/19939/9/1994, 59 FR 46562 211.1070Cleaning Materials1/18/199410/21/1996, 61 FR 54556 211.1090Clear Coating9/27/19939/9/1994, 59 FR 46562 211.1095Clear Coating for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.1110Clear Topcoat9/27/19939/9/1994, 59 FR 46562 211.1120Clinker3/15/200111/8/2001, 66 FR 56449 211.1128Closed Molding9/14/20103/23/2012, 77 FR 16940 211.1130Closed Purge System9/27/19939/9/1994, 59 FR 46562 211.1150Closed Vent System9/27/19939/9/1994, 59 FR 46562 211.1170Coal Refuse9/27/19939/9/1994, 59 FR 46562 211.1190Coating9/27/19939/9/1994, 59 FR 46562 211.1210Coating Applicator9/27/19939/9/1994, 59 FR 46562 211.1230Coating Line9/27/19939/9/1994, 59 FR 46562 211.1250Coating Plant9/27/19939/9/1994, 59 FR 46562 211.1270Coil Coating9/27/19939/9/1994, 59 FR 46562 211.1290Coil Coating Line9/27/19939/9/1994, 59 FR 46562 211.1310Cold Cleaning9/27/19939/9/1994, 59 FR 46562 211.1326Commercial Exterior Aerodynamic Structure Primer3/4/20214/11/2023, 88 FR 21490 211.1327Commercial Interior Adhesive3/4/20214/11/2023, 88 FR 21490 211.1329Compatible Substrate Primer3/4/20214/11/2023, 88 FR 21490 211.1330Complete Combustion9/27/19939/9/1994, 59 FR 46562 211.1350Component9/27/19939/9/1994, 59 FR 46562 211.1370Concrete Curing Compounds9/27/19939/9/1994, 59 FR 46562 211.1390Concentrated Nitric Acid Manufacturing Process9/27/19939/9/1994, 59 FR 46562 211.1410Condensate9/27/19939/9/1994, 59 FR 46562 211.1430Condensible PM 109/27/19939/9/1994, 59 FR 46562 211.1432Confined Space3/4/20214/11/2023, 88 FR 21490 211.1455Contact Adhesive9/14/20103/23/2012, 77 FR 16940 211.1467Continuous Coater2/2/19985/19/1998, 63 FR 27489 211.1470Continuous Process9/27/19939/9/1994, 59 FR 46562 211.1490Control Device9/27/19939/9/1994, 59 FR 46562 211.1510Control Device Efficiency9/27/19939/9/1994, 59 FR 46562 211.1520Conventional Air Spray2/2/19985/19/1998, 63 FR 27489 211.1530Conventional Soybean Crushing Source9/27/19939/9/1994, 59 FR 46562 211.1550Conveyorized Degreasing9/27/19939/9/1994, 59 FR 46562 211.1555Corrosion Prevention System3/4/20214/11/2023, 88 FR 21490 211.1560Cove Base9/14/20103/23/2012, 77 FR 16940 211.1565Cove Base Installation Adhesive9/14/20103/23/2012, 77 FR 16940 211.1567Critical Use and Line Sealer Maskant3/4/20214/11/2023, 88 FR 21490 211.1570Crude Oil9/27/19939/9/1994, 59 FR 46562 211.1590Crude Oil Gathering9/27/19939/9/1994, 59 FR 46562 211.1610Crushing9/27/19939/9/1994, 59 FR 46562 211.1620Cryogenic Flexible Primer3/4/20214/11/2023, 88 FR 21490 211.1625Cryoprotective Coating3/4/20214/11/2023, 88 FR 21490 211.1630Custody Transfer9/27/19939/9/1994, 59 FR 46562 211.1650Cutback Asphalt9/27/19939/9/1994, 59 FR 46562 211.1655Cyanoacrylate Adhesive9/14/20103/23/2012, 77 FR 16940 211.1670Daily Weighted Average VOM Content9/27/19939/9/1994, 59 FR 46562 211.1690Day9/27/19939/9/1994, 59 FR 46562 211.1700Deadener9/14/20103/23/2012, 77 FR 16940 211.1710Degreaser9/27/19939/9/1994, 59 FR 46562 211.1730Delivery Vessel9/27/19939/9/1994, 59 FR 46562 211.1735Department of Defense Classified Coating3/4/20214/11/2023, 88 FR 21490 211.1740Diesel Engine9/25/20076/26/2009, 74 FR 30466 211.1745Digital Printing6/25/20103/23/2012, 77 FR 16940 211.1750Dip Coating9/27/19939/9/1994, 59 FR 46562 211.1770Distillate Fuel Oil9/27/19939/9/1994, 59 FR 46562 211.1780Distillation Unit5/9/19953/23/1998, 63 FR 13784 211.1790Drum9/27/19939/9/1994, 59 FR 46562 211.1810Dry Cleaning Operation or Dry Cleaning Facility9/27/19939/9/1994, 59 FR 46562 211.1820Dry Lubricative Material for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.1830Dump Pit Area9/27/19939/9/1994, 59 FR 46562 211.1850Effective Grate Area9/27/19939/9/1994, 59 FR 46562 211.1870Effluent Water Separator9/27/19939/9/1994, 59 FR 46562 211.1872Ejection Cartridge Sealant9/14/20103/23/2012, 77 FR 16940 211.1875Elastomeric Materials5/9/19957/25/1996, 61 FR 38577 211.1876Electric Dissipating Coating9/14/20103/23/2012, 77 FR 16940 211.1877Electric-Insulating Varnish9/14/20103/23/2012, 77 FR 16940 211.1878Electrical Apparatus Component6/25/20103/23/2012, 77 FR 16940 211.1880Electrical Switchgear Compartment Coating9/14/20103/23/2012, 77 FR 16940 211.1882Electrodeposition Primer (EDP)9/14/20103/23/2012, 77 FR 16940 211.1883Electromagnetic Interference/Radio Frequency Interference (EMI/RFI) Shielding Coatings9/14/20103/23/2012, 77 FR 16940 211.1885Electronic Component6/25/20103/23/2012, 77 FR 16940 211.1890Electrostatic Bell or Disc Spray9/27/19939/9/1994, 59 FR 46562 211.1895Electrostatic Discharge and Electromagnetic Interference Coating3/4/20214/11/2023, 88 FR 21490 211.1900Electrostatic Prep Coat5/9/199510/26/1995, 60 FR 54807 211.1910Electrostatic Spray9/27/19939/9/1994, 59 FR 46562 211.1915Elevated-Temperature Skydrol-Resistant Commercial Primer3/4/20214/11/2023, 88 FR 21490 211.1920Emergency or Standby Unit9/25/20076/26/2009, 74 FR 30466 211.1930Emission Rate9/27/19939/9/1994, 59 FR 46562 211.1950Emission Unit9/27/19939/9/1994, 59 FR 46562 211.1970Enamel9/27/19939/9/1994, 59 FR 46562 211.1990Enclose9/27/19939/9/1994, 59 FR 46562 211.2010End Sealing Compound Coat9/27/19939/9/1994, 59 FR 46562 211.2030Enhanced Under-the-Cup Fill1/18/199410/21/1996, 61 FR 54556 211.2035Epoxy Polyamide Topcoat3/4/20214/11/2023, 88 FR 21490 211.2040Etching Filler9/14/20103/23/2012, 77 FR 16940 211.2050Ethanol Blend Gasoline9/27/19939/9/1994, 59 FR 46562 211.2055Ethylene Propylenediene Monomer (DPDM) Roof Membrane9/14/20103/23/2012, 77 FR 16940 211.2070Excess Air9/27/19939/9/1994, 59 FR 46562 211.2090Excessive Release9/27/19939/9/1994, 59 FR 46562 211.2130Existing Grain Handling Operation9/27/19939/9/1994, 59 FR 46562 211.2150Exterior Base Coat9/27/19939/9/1994, 59 FR 46562 211.2170Exterior End Coat9/27/19939/9/1994, 59 FR 46562 211.2180Exterior Primer for Large Commercial Aircraft3/4/20214/11/2023, 88 FR 21490 211.2190External Floating Roof9/27/19939/9/1994, 59 FR 46562 211.2200Extreme High-Gloss Coating7/27/20113/23/2012, 77 FR 16940 211.2210Extreme Performance Coating9/14/20103/23/2012, 77 FR 16940 211.2230Fabric Coating9/27/19939/9/1994, 59 FR 46562 211.2250Fabric Coating Line9/27/19939/9/1994, 59 FR 46562 211.2270Federally Enforceable Limitations and Conditions9/27/19939/9/1994, 59 FR 46562 211.2285Feed Mill6/17/19972/17/2000, 65 FR 8064 211.2300Fill11/15/19948/8/1996, 61 FR 41338 211.2310Final Repair Coat9/14/20103/23/2012, 77 FR 16940 211.2320Finish Primer Surfacer9/14/20103/23/2012, 77 FR 16940 211.2330Firebox9/27/19939/9/1994, 59 FR 46562 211.2340Fire-Resistant Interior Coating3/4/20214/11/2023, 88 FR 21490 211.2350Fixed Roof Tank9/27/19939/9/1994, 59 FR 46562 211.2358Flat Wood Paneling7/27/20113/23/2012, 77 FR 16940 211.2359Flat Wood Paneling Coating Line6/25/20103/23/2012, 77 FR 16940 211.2360Flexible Coating9/14/20103/23/2012, 77 FR 16940 211.2365Flexible Operation Unit5/9/19953/23/1998, 63 FR 13784 211.2368Flexible Packaging6/25/20103/23/2012, 77 FR 16940 211.2369Flexible Vinyl9/14/20103/23/2012, 77 FR 16940 211.2370Flexographic Printing9/27/19939/9/1994, 59 FR 46562 211.2390Flexographic Printing Line9/27/19939/9/1994, 59 FR 46562 211.2400Flight Test Coating3/4/20214/11/2023, 88 FR 21490 211.2410Floating Roof9/27/19939/9/1994, 59 FR 46562 211.2412Flush Cleaning at Aerospace Facilities3/4/20214/11/2023, 88 FR 21490 211.2415Fog Coat9/14/20103/23/2012, 77 FR 16940 211.2430Fountain Solution9/27/19939/9/1994, 59 FR 46562 211.2450Freeboard Height9/27/19939/9/1994, 59 FR 46562 211.2470Fuel Combustion Emission Unit or Fuel Combustion Emission Source9/27/19939/9/1994, 59 FR 46562 211.2480Fuel Tank Adhesive for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.2485Fuel Tank Coating for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.2490Fugitive Particulate Matter9/27/19939/9/1994, 59 FR 46562 211.2510Full Operating Flowrate9/27/19939/9/1994, 59 FR 46562 211.2525Gasket/Gasket Sealing Material9/14/20103/23/2012, 77 FR 16940 211.2530Gas Service9/27/19939/9/1994, 59 FR 46562 211.2550Gas/Gas Method9/27/19939/9/1994, 59 FR 46562 211.2570Gasoline9/27/19939/9/1994, 59 FR 46562 211.2590Gasoline Dispensing Operation or Gasoline Dispensing Facility9/27/19939/9/1994, 59 FR 46562 211.2610Gel Coat1/18/199410/21/1996, 61 FR 54556 211.2612General Aviation3/4/20214/11/2023, 88 FR 21490 211.2613General Aviation Rework Facility3/4/20214/11/2023, 88 FR 21490 211.2615General Work Surface6/25/20103/23/2012, 77 FR 16940 211.2622Glass Bonding Primer9/14/20103/23/2012, 77 FR 16940 211.2630Gloss Reducers5/9/199510/26/1995, 60 FR 54807 211.2650Grain9/27/19939/9/1994, 59 FR 46562 211.2670Grain Drying Operation9/27/19939/9/1994, 59 FR 46562 211.2690Grain Handling and Conditioning Operation9/27/19939/9/1994, 59 FR 46562 211.2710Grain Handling Operation9/27/19939/9/1994, 59 FR 46562 211.2730Green Tire Spraying9/27/19939/9/1994, 59 FR 46562 211.2750Green Tires9/27/19939/9/1994, 59 FR 46562 211.2770Gross Heating Value9/27/19939/9/1994, 59 FR 46562 211.2790Gross Vehicle Weight Rating9/27/19939/9/1994, 59 FR 46562 211.2795Hand-Wipe Cleaning Operation at Aerospace Facilities3/4/20214/11/2023, 88 FR 21490 211.2800Hardwood Plywood7/27/20113/23/2012, 77 FR 16940 211.2810Heated Airless Spray9/27/19939/9/1994, 59 FR 46562 211.2825Heat-Resistant Coating9/14/20103/23/2012, 77 FR 16940 211.2830Heatset6/25/20103/23/2012, 77 FR 16940 211.2840Heatset Web Letterpress Printing Line6/25/20103/23/2012, 77 FR 16940 211.2850Heatset Web Offset Lithographic Printing Line5/9/199511/8/1995, 60 FR 56238 211.2870Heavy Liquid1/28/201310/6/2014, 79 FR 60070 211.2890Heavy Metals9/27/19939/9/1994, 59 FR 46562 211.2910Heavy Off Highway Vehicle Products9/27/19939/9/1994, 59 FR 46562 211.2930Heavy Off Highway Vehicle Products Coating9/27/19939/9/1994, 59 FR 46562 211.2950Heavy Off Highway Vehicle Products Coating Line9/27/19939/9/1994, 59 FR 46562 211.2955High Bake Coating9/14/20103/23/2012, 77 FR 16940 211.2956High Build Primer Surfacer9/14/20103/23/2012, 77 FR 16940 211.2958High Gloss Coating9/14/20103/23/2012, 77 FR 16940 211.2960High-Performance Architectural Coating9/14/20103/23/2012, 77 FR 16940 211.2965High Precision Optic6/25/20103/23/2012, 77 FR 16940 211.2970High Temperature Aluminum Coating9/27/19939/9/1994, 59 FR 46562 211.2980High Temperature Coating3/4/20214/11/2023, 88 FR 21490 211.2990High Volume Low Pressure (HVLP) Spray9/27/19939/9/1994, 59 FR 46562 211.3010Hood9/27/19939/9/1994, 59 FR 46562 211.3030Hot Well9/27/19939/9/1994, 59 FR 46562 211.3050Housekeeping Practices9/27/19939/9/1994, 59 FR 46562 211.3070Incinerator9/27/19939/9/1994, 59 FR 46562 211.3090Indirect Heat Transfer9/27/19939/9/1994, 59 FR 46562 211.3095Indoor Floor Covering Installation Adhesive9/14/20103/23/2012, 77 FR 16940 211.3110Ink9/27/19939/9/1994, 59 FR 46562 211.3120In-Line Repair9/14/20103/23/2012, 77 FR 16940 211.3130In-Process Tank9/27/19939/9/1994, 59 FR 46562 211.3150In-Situ Sampling Systems9/27/19939/9/1994, 59 FR 46562 211.3160Insulation Covering3/4/20214/11/2023, 88 FR 21490 211.3170Interior Body Spray Coat9/27/19939/9/1994, 59 FR 46562 211.3180Intermediate Release Coating3/4/20214/11/2023, 88 FR 21490 211.3190Internal Floating Roof9/27/19939/9/1994, 59 FR 46562 211.3210Internal Transferring Area9/27/19939/9/1994, 59 FR 46562 211.3215Janitorial Cleaning6/25/20103/23/2012, 77 FR 16940 211.3230Lacquers3/4/20214/11/2023, 88 FR 21490 211.3240Laminate9/14/20103/23/2012, 77 FR 16940 211.3250Large Appliance9/27/19939/9/1994, 59 FR 46562 211.3270Large Appliance Coating9/27/19939/9/1994, 59 FR 46562 211.3290Large Appliance Coating Line9/27/19939/9/1994, 59 FR 46562 211.3300Lean-Burn Engine9/25/20076/26/2009, 74 FR 30466 211.3305Letterpress Printing Line6/25/20103/23/2012, 77 FR 16940 211.3310Light Liquid9/27/19939/9/1994, 59 FR 46562 211.3330Light Duty Truck9/27/19939/9/1994, 59 FR 46562 211.3350Light Oil9/27/19939/9/1994, 59 FR 46562 211.3360Limited Access Space3/4/20214/11/2023, 88 FR 21490 211.3370Liquid/Gas Method9/27/19939/9/1994, 59 FR 46562 211.3390Liquid Mounted Seal9/27/19939/9/1994, 59 FR 46562 211.3410Liquid Service9/27/19939/9/1994, 59 FR 46562 211.3430Liquids Dripping9/27/19939/9/1994, 59 FR 46562 211.3450Lithographic Printing Line9/27/19939/9/1994, 59 FR 46562 211.3470Load Out Area9/27/19939/9/1994, 59 FR 46562 211.3480Loading Event10/25/19944/3/1995, 60 FR 16801 211.3483Long Dry Kiln3/15/200111/8/2001, 66 FR 56449 211.3485Long Wet Kiln3/15/200111/8/2001, 66 FR 56449 211.3487Low-NOX Burner3/15/200111/8/2001, 66 FR 56449 211.3490Low Solvent Coating9/27/19939/9/1994, 59 FR 46562 211.3505Lubricating Wax/Compound9/14/20103/23/2012, 77 FR 16940 211.3510Magnet Wire9/27/19939/9/1994, 59 FR 46562 211.3530Magnet Wire Coating9/27/19939/9/1994, 59 FR 46562 211.3550Magnet Wire Coating Line9/27/19939/9/1994, 59 FR 46562 211.3555Maintenance Cleaning6/25/20103/23/2012, 77 FR 16940 211.3570Major Dump Pit9/27/19939/9/1994, 59 FR 46562 211.3590Major Metropolitan Area (MMA)9/27/19939/9/1994, 59 FR 46562 211.3610Major Population Area (MPA)9/27/19939/9/1994, 59 FR 46562 211.3630Manufacturing Process9/27/19939/9/1994, 59 FR 46562 211.3650Marine Terminal10/25/19944/3/1995, 60 FR 16801 211.3660Marine Vessel10/25/19944/3/1995, 60 FR 16801 211.3665Mask Coating9/14/20103/23/2012, 77 FR 16940 211.3670Material Recovery Section9/27/19939/9/1994, 59 FR 46562 211.3690Maximum Theoretical Emissions9/27/19939/9/1994, 59 FR 46562 211.3695Maximum True Vapor Pressure11/15/19948/8/1996, 61 FR 41338 211.3705Medical Device6/25/20103/23/2012, 77 FR 16940 211.3707Medical Device and Pharmaceutical Manufacturing6/25/20103/23/2012, 77 FR 16940 211.3710Metal Furniture9/27/19939/9/1994, 59 FR 46562 211.3730Metal Furniture Coating9/27/19939/9/1994, 59 FR 46562 211.3750Metal Furniture Coating Line9/27/19939/9/1994, 59 FR 46562 211.3755Metalized Epoxy Coating3/4/20214/11/2023, 88 FR 21490 211.3760Metallic Coating9/14/20103/23/2012, 77 FR 16940 211.3770Metallic Shoe Type Seal9/27/19939/9/1994, 59 FR 46562 211.3775Metal to Urethane/Rubber Molding or Casting Adhesive9/14/20103/23/2012, 77 FR 16940 211.3780Mid-Kiln Firing3/15/200111/8/2001, 66 FR 56449 211.3785Military Specification Coating9/14/20103/23/2012, 77 FR 16940 211.3790Miscellaneous Fabricated Product Manufacturing Process9/27/19939/9/1994, 59 FR 46562 211.3810Miscellaneous Formulation Manufacturing Process9/27/19939/9/1994, 59 FR 46562 211.3820Miscellaneous Industrial Adhesive Application Operation9/14/20103/23/2012, 77 FR 16940 211.3830Miscellaneous Metal Parts and Products9/27/19939/9/1994, 59 FR 46562 211.3850Miscellaneous Metal Parts and Products Coating3/4/20214/11/2023, 88 FR 21490 211.3870Miscellaneous Metal Parts or Products Coating Line3/4/20214/11/2023, 88 FR 21490 211.3890Miscellaneous Organic Chemical Manufacturing Process9/27/19939/9/1994, 59 FR 46562 211.3910Mixing Operation9/27/19939/9/1994, 59 FR 46562 211.3915Mobile Equipment5/9/19957/25/1996, 61 FR 38577 211.3920Mold Release Coating for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.3925Mold Seal Coating9/14/20103/23/2012, 77 FR 16940 211.3930Monitor9/27/19939/9/1994, 59 FR 46562 211.3950Monomer1/18/199410/21/1996, 61 FR 54556 211.3960Motor Vehicles5/9/19957/25/1996, 61 FR 38577 211.3961Motor Vehicle Adhesive9/14/20103/23/2012, 77 FR 16940 211.3965Motor Vehicle Refinishing5/9/19957/25/1996, 61 FR 38577 211.3966Motor Vehicle Weatherstrip Adhesive9/14/20103/23/2012, 77 FR 16940 211.3967Mouth Waterproofing Sealant9/14/20103/23/2012, 77 FR 16940 211.3968Multi-Colored Coating9/14/20103/23/2012, 77 FR 16940 211.3969Multi-Component Coating9/14/20103/23/2012, 77 FR 16940 211.3970Multiple Package Coating9/27/19939/9/1994, 59 FR 46562 211.3975Multipurpose Construction Adhesive9/14/20103/23/2012, 77 FR 16940 211.3985Natural Finish Hardwood Plywood Panel7/27/20113/23/2012, 77 FR 16940 211.3990New Grain Drying Operation9/27/19939/9/1994, 59 FR 46562 211.4010New Grain Handling Operation9/27/19939/9/1994, 59 FR 46562 211.4030No Detectable Volatile Organic Material Emissions9/27/19939/9/1994, 59 FR 46562 211.4050Non-Contact Process Water Cooling Tower1/18/199410/21/1996, 61 FR 54556 211.4052Non-Convertible Coating9/14/20103/23/2012, 77 FR 16940 211.4055Non-Flexible Coating5/9/199510/26/1995, 60 FR 54807 211.4065Non-Heatset6/25/20103/23/2012, 77 FR 16940 211.4066Nonstructural Adhesive3/4/20214/11/2023, 88 FR 21490 211.4067NOX Trading Program4/17/200111/8/2001, 66 FR 56449 211.4070Offset9/27/19939/9/1994, 59 FR 46562 211.4080One-Component Coating9/14/20103/23/2012, 77 FR 16940 211.4090One Hundred Percent Acid9/27/19939/9/1994, 59 FR 46562 211.4110One Turn Storage Space9/27/19939/9/1994, 59 FR 46562 211.4130Opacity9/27/19939/9/1994, 59 FR 46562 211.4150Opaque Stains9/27/19939/9/1994, 59 FR 46562 211.4170Open Top Vapor Degreasing9/27/19939/9/1994, 59 FR 46562 211.4190Open Ended Valve9/27/19939/9/1994, 59 FR 46562 211.4210Operator of a Gasoline Dispensing Operation or Operator of a Gasoline Dispensing Facility9/27/19939/9/1994, 59 FR 46562 211.4215Optical Antireflection Coating3/4/20214/11/2023, 88 FR 21490 211.4220Optical Coating9/14/20103/23/2012, 77 FR 16940 211.4230Organic Compound9/27/19939/9/1994, 59 FR 46562 211.4250Organic Material and Organic Materials10/19/19953/21/1996, 61 FR 11550 211.4260Organic Solvent10/19/19953/21/1996, 61 FR 11550 211.4270Organic Vapor9/27/19939/9/1994, 59 FR 46562 211.4285Outdoor Floor Covering Installation Adhesive9/14/20103/23/2012, 77 FR 16940 211.4290Oven9/27/19939/9/1994, 59 FR 46562 211.4310Overall Control9/27/19939/9/1994, 59 FR 46562 211.4330Overvarnish9/27/19939/9/1994, 59 FR 46562 211.4350Owner of a Gasoline Dispensing Operation or Owner of a Gasoline Dispensing Facility9/27/19939/9/1994, 59 FR 46562 211.4370Owner or Operator9/27/19939/9/1994, 59 FR 46562 211.4390Packaging Rotogravure Printing9/27/19939/9/1994, 59 FR 46562 211.4410Packaging Rotogravure Printing Line9/27/19939/9/1994, 59 FR 46562 211.4430Pail9/27/19939/9/1994, 59 FR 46562 211.4450Paint Manufacturing Source or Paint Manufacturing Plant9/27/19939/9/1994, 59 FR 46562 211.4455Pan-Backing Coating9/14/20103/23/2012, 77 FR 16940 211.4460Panel7/27/20113/23/2012, 77 FR 16940 211.4470Paper Coating9/27/19939/9/1994, 59 FR 46562 211.4490Paper Coating Line9/27/19939/9/1994, 59 FR 46562 211.4510Particulate Matter9/27/19939/9/1994, 59 FR 46562 211.4530Parts per Million (Volume) or Ppm (VOL)9/27/19939/9/1994, 59 FR 46562 211.4535Part Marking Aerospace Coating3/4/20214/11/2023, 88 FR 21490 211.4540Perimeter Bonded Sheet Flooring9/14/20103/23/2012, 77 FR 16940 211.4550Person9/27/19939/9/1994, 59 FR 46562 211.4590Petroleum9/27/19939/9/1994, 59 FR 46562 211.4610Petroleum Liquid10/19/19953/21/1996, 61 FR 11550 211.4630Petroleum Refinery9/27/19939/9/1994, 59 FR 46562 211.4650Pharmaceutical9/27/19939/9/1994, 59 FR 46562 211.4670Pharmaceutical Coating Operation9/27/19939/9/1994, 59 FR 46562 211.4690Photochemically Reactive Material9/27/19939/9/1994, 59 FR 46562 211.4710Pigmented Coatings9/27/19939/9/1994, 59 FR 46562 211.4730Plant9/27/19939/9/1994, 59 FR 46562 211.4735Plastic9/14/20103/23/2012, 77 FR 16940 211.4740Plastic Part5/9/199510/26/1995, 60 FR 54807 211.4750Plasticizers9/27/19939/9/1994, 59 FR 46562 211.4760Plastic Solvent Welding Adhesive9/14/20103/23/2012, 77 FR 16940 211.4765Plastic Solvent Welding Adhesive Primer9/14/20103/23/2012, 77 FR 16940 211.4768Pleasure Craft9/14/20103/23/2012, 77 FR 16940 211.4769Pleasure Craft Surface Coating9/14/20103/23/2012, 77 FR 16940 211.4770PM 109/27/19939/9/1994, 59 FR 46562 211.4790Pneumatic Rubber Tire Manufacture9/27/19939/9/1994, 59 FR 46562 211.4810Polybasic Organic Acid Partial Oxidation Manufacturing Process9/27/19939/9/1994, 59 FR 46562 211.4830Polyester Resin Material(s)1/18/199410/21/1996, 61 FR 54556 211.4850Polyester Resin Products Manufacturing Process1/18/199410/21/1996, 61 FR 54556 211.4870Polystyrene Plant9/27/19939/9/1994, 59 FR 46562 211.4890Polystyrene Resin9/27/19939/9/1994, 59 FR 46562 211.4895Polyvinyl Chloride Plastic (PVC Plastic)9/14/20103/23/2012, 77 FR 16940 211.4900Porous Material9/14/20103/23/2012, 77 FR 16940 211.4910Portable Grain Handling Equipment9/27/19939/9/1994, 59 FR 46562 211.4930Portland Cement Manufacturing Process Emission Source9/27/19939/9/1994, 59 FR 46562 211.4950Portland Cement Process or Portland Cement Manufacturing Plant9/27/19939/9/1994, 59 FR 46562 211.4970Potential To Emit1/18/199410/21/1996, 61 FR 54556 211.4990Power Driven Fastener Coating9/27/19939/9/1994, 59 FR 46562 211.5010Precoat5/9/19957/25/1996, 61 FR 38577 211.5012Prefabricated Architectural Coating9/14/20103/23/2012, 77 FR 16940 211.5015Preheater Kiln3/15/200111/8/2001, 66 FR 56449 211.5020Preheater/Precalciner Kiln3/15/200111/8/2001, 66 FR 56449 211.5030Pressure Release9/27/19939/9/1994, 59 FR 46562 211.5050Pressure Tank9/27/19939/9/1994, 59 FR 46562 211.5060Pressure/Vacuum Relief Valve9/21/19941/27/1995, 60 FR 5318 211.5061Pretreatment Coating9/14/20103/23/2012, 77 FR 16940 211.5062Pretreatment Wash Primer9/14/20103/23/2012, 77 FR 16940 211.5065Primary Product5/9/19953/23/1998, 63 FR 13784 211.5070Prime Coat9/27/19939/9/1994, 59 FR 46562 211.5072Primer for General Aviation Rework Facility3/4/20214/11/2023, 88 FR 21490 211.5075Primer Sealant9/14/20103/23/2012, 77 FR 16940 211.5080Primer Sealer5/9/19957/25/1996, 61 FR 38577 211.5090Primer Surfacer Coat9/14/20103/23/2012, 77 FR 16940 211.5110Primer Surfacer Operation9/27/19939/9/1994, 59 FR 46562 211.5130Primers9/27/19939/9/1994, 59 FR 46562 211.5140Printed Interior Panel7/27/20113/23/2012, 77 FR 16940 211.5150Printing9/27/19939/9/1994, 59 FR 46562 211.5170Printing Line9/27/19939/9/1994, 59 FR 46562 211.5185Process Emission Source9/27/19939/9/1994, 59 FR 46562 211.5190Process Emission Unit9/27/19939/9/1994, 59 FR 46562 211.5210Process Unit9/27/19939/9/1994, 59 FR 46562 211.5230Process Unit Shutdown9/27/19939/9/1994, 59 FR 46562 211.5245Process Vent5/22/19954/2/1996, 61 FR 14484 211.5250Process Weight Rate9/27/19939/9/1994, 59 FR 46562 211.5270Production Equipment Exhaust System9/27/19939/9/1994, 59 FR 46562 211.5310Publication Rotogravure Printing Line9/27/19939/9/1994, 59 FR 46562 211.5330Purged Process Fluid9/27/19939/9/1994, 59 FR 46562 211.5335Radiation Effect Coating6/25/20103/23/2012, 77 FR 16940 211.5336Radiation-Effect or Electric Coating3/4/20214/11/2023, 88 FR 21490 211.5338Radome3/4/20214/11/2023, 88 FR 21490 211.5339Rain Erosion-Resistant Coating3/4/20214/11/2023, 88 FR 21490 211.5350Reactor9/27/19939/9/1994, 59 FR 46562 211.5370Reasonably Available Control Technology (RACT)9/27/19939/9/1994, 59 FR 46562 211.5390Reclamation System1/18/199410/21/1996, 61 FR 54556 211.5400Red Coating9/14/20103/23/2012, 77 FR 16940 211.5410Refiner9/27/19939/9/1994, 59 FR 46562 211.5430Refinery Fuel Gas9/27/19939/9/1994, 59 FR 46562 211.5450Refinery Fuel Gas System9/27/19939/9/1994, 59 FR 46562 211.5470Refinery Unit or Refinery Process Unit9/27/19939/9/1994, 59 FR 46562 211.5480Reflective Argent Coating5/9/199510/26/1995, 60 FR 54807 211.5490Refrigerated Condenser9/27/19939/9/1994, 59 FR 46562 211.5500Regulated Air Pollutant12/7/19934/5/1995, 60 FR 17229 211.5510Reid Vapor Pressure1/28/201310/6/2014, 79 FR 60070 211.5520Reinforced Plastic Composite9/14/20103/23/2012, 77 FR 16940 211.5530Repair1/18/199410/21/1996, 61 FR 54556 211.5535Repair Cleaning6/25/20103/23/2012, 77 FR 16940 211.5550Repair Coat9/14/20103/23/2012, 77 FR 16940 211.5570Repaired9/27/19939/9/1994, 59 FR 46562 211.5585Research and Development Operation3/4/20214/11/2023, 88 FR 21490 211.5590Residual Fuel Oil9/27/19939/9/1994, 59 FR 46562 211.5600Resist Coat5/9/199510/26/1995, 60 FR 54807 211.5610Restricted Area9/27/19939/9/1994, 59 FR 46562 211.5630Retail Outlet9/27/19939/9/1994, 59 FR 46562 211.5640Rich-Burn Engine9/25/20076/26/2009, 74 FR 30466 211.5650Ringelmann Chart9/27/19939/9/1994, 59 FR 46562 211.5670Roadway9/27/19939/9/1994, 59 FR 46562 211.5675Rocket Motor Bonding Adhesive3/4/20214/11/2023, 88 FR 21490 211.5680Rocket Motor Nozzle Coating3/4/20214/11/2023, 88 FR 21490 211.5690Roll Coater9/27/19939/9/1994, 59 FR 46562 211.5710Roll Coating9/27/19939/9/1994, 59 FR 46562 211.5730Roll Printer9/27/19939/9/1994, 59 FR 46562 211.5750Roll Printing9/27/19939/9/1994, 59 FR 46562 211.5770Rotogravure Printing9/27/19939/9/1994, 59 FR 46562 211.5790Rotogravure Printing Line9/27/19939/9/1994, 59 FR 46562 211.5800Rubber9/14/20103/23/2012, 77 FR 16940 211.5805Rubber-Based Adhesive3/4/20214/11/2023, 88 FR 21490 211.5810Safety Relief Valve9/27/19939/9/1994, 59 FR 46562 211.5830Sandblasting9/27/19939/9/1994, 59 FR 46562 211.5850Sanding Sealers9/27/19939/9/1994, 59 FR 46562 211.5855Scale Inhibitor3/4/20214/11/2023, 88 FR 21490 211.5860Scientific Instrument6/25/20103/23/2012, 77 FR 16940 211.5870Screening9/27/19939/9/1994, 59 FR 46562 211.5875Screen Printing6/25/20103/23/2012, 77 FR 16940 211.5883Screen Print Ink for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.5885Screen Reclamation6/25/20103/23/2012, 77 FR 16940 211.5887Sealant for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.5890Sealer9/14/20103/23/2012, 77 FR 16940 211.5895Seal Coat Maskant3/4/20214/11/2023, 88 FR 21490 211.5900Self-Priming Topcoat for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.5905Self-Priming Topcoat for General Aviation Rework Facility3/4/20214/11/2023, 88 FR 21490 211.5907Semi-Aqueous Cleaning Solvent3/4/20214/11/2023, 88 FR 21490 211.5910Semi Transparent Stains9/27/19939/9/1994, 59 FR 46562 211.5930Sensor9/27/19939/9/1994, 59 FR 46562 211.5950Set of Safety Relief Valves9/27/19939/9/1994, 59 FR 46562 211.5970Sheet Basecoat9/27/19939/9/1994, 59 FR 46562 211.5980Sheet-Fed5/9/199511/8/1995, 60 FR 56238 211.5985Sheet Rubber Lining Installation9/14/20103/23/2012, 77 FR 16940 211.5987Shock-Free Coating9/14/20103/23/2012, 77 FR 16940 211.5990Shotblasting9/27/19939/9/1994, 59 FR 46562 211.6010Side Seam Spray Coat9/27/19939/9/1994, 59 FR 46562 211.6012Silicone-Release Coating9/14/20103/23/2012, 77 FR 16940 211.6013Silicone Insulation Material3/4/20214/11/2023, 88 FR 21490 211.6015Single-Ply Roof Membrane9/14/20103/23/2012, 77 FR 16940 211.6017Single-Ply Roof Membrane Adhesive Primer9/14/20103/23/2012, 77 FR 16940 211.6020Single-Ply Roof Membrane Installation and Repair Adhesive9/14/20103/23/2012, 77 FR 16940 211.6025Single Unit Operation5/22/19954/2/1996, 61 FR 14484 211.6030Smoke9/27/19939/9/1994, 59 FR 46562 211.6050Smokeless Flare9/27/19939/9/1994, 59 FR 46562 211.6055Smoothing and Caulking Compounds3/4/20214/11/2023, 88 FR 21490 211.6060Soft Coat5/9/199510/26/1995, 60 FR 54807 211.6063Solar-Absorbent Coating9/14/20103/23/2012, 77 FR 16940 211.6064Solid Film Lubricant3/4/20214/11/2023, 88 FR 21490 211.6065Solids Turnover Ratio (RT)9/14/20103/23/2012, 77 FR 16940 211.6070Solvent9/27/19939/9/1994, 59 FR 46562 211.6090Solvent Cleaning9/27/19939/9/1994, 59 FR 46562 211.6110Solvent Recovery System1/18/199410/21/1996, 61 FR 54556 211.6130Source4/17/200111/8/2001, 66 FR 56449 211.6133Space Vehicle3/4/20214/11/2023, 88 FR 21490 211.6137Specialized Function Coating3/4/20214/11/2023, 88 FR 21490 211.6140Specialty Coatings5/9/199510/26/1995, 60 FR 54807 211.6145Specialty Coatings for Motor Vehicles5/9/19957/25/1996, 61 FR 38577 211.6150Specialty High Gloss Catalyzed Coating9/27/19939/9/1994, 59 FR 46562 211.6170Specialty Leather1/18/199410/21/1996, 61 FR 54556 211.6190Specialty Soybean Crushing Source9/27/19939/9/1994, 59 FR 46562 211.6210Splash Loading9/27/19939/9/1994, 59 FR 46562 211.6230Stack9/27/19939/9/1994, 59 FR 46562 211.6250Stain Coating1/18/199410/21/1996, 61 FR 54556 211.6270Standard Conditions9/27/19939/9/1994, 59 FR 46562 211.6290Standard Cubic Foot (Scf)9/27/19939/9/1994, 59 FR 46562 211.6310Start Up9/27/19939/9/1994, 59 FR 46562 211.6330Stationary Emission Source9/27/19939/9/1994, 59 FR 46562 211.6350Stationary Emission Unit9/27/19939/9/1994, 59 FR 46562 211.6370Stationary Source9/27/19939/9/1994, 59 FR 46562 211.6390Stationary Storage Tank9/27/19939/9/1994, 59 FR 46562 211.6400Stencil Coat9/14/20103/23/2012, 77 FR 16940 211.6405Sterilization Indicating Ink6/25/20103/23/2012, 77 FR 16940 211.6410Storage Tank or Storage Vessel9/27/19939/9/1994, 59 FR 46562 211.6420Strippable Spray Booth Coating2/2/19985/19/1998, 63 FR 27489 211.6425Stripping6/25/20103/23/2012, 77 FR 16940 211.6426Structural Autoclavable Adhesive for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.6427Structural Glazing9/14/20103/23/2012, 77 FR 16940 211.6428Structural Nonautoclavable Adhesive for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.6430Styrene Devolatilizer Unit9/27/19939/9/1994, 59 FR 46562 211.6450Styrene Recovery Unit9/27/19939/9/1994, 59 FR 46562 211.6460Subfloor9/14/20103/23/2012, 77 FR 16940 211.6470Submerged Loading Pipe9/27/19939/9/1994, 59 FR 46562 211.6490Substrate9/27/19939/9/1994, 59 FR 46562 211.6510Sulfuric Acid Mist9/27/19939/9/1994, 59 FR 46562 211.6530Surface Condenser9/27/19939/9/1994, 59 FR 46562 211.6535Surface Preparation6/25/20103/23/2012, 77 FR 16940 211.6540Surface Preparation Materials5/9/19957/25/1996, 61 FR 38577 211.6550Synthetic Organic Chemical or Polymer Manufacturing Plant9/27/19939/9/1994, 59 FR 46562 211.6570Tablet Coating Operation9/27/19939/9/1994, 59 FR 46562 211.6575Temporary Protective Coating for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.6580Texture Coat5/9/199510/26/1995, 60 FR 54807 211.6583Thermal Control Coating for Aerospace Applications3/4/20214/11/2023, 88 FR 21490 211.6585Thin Metal Laminating Adhesive9/14/20103/23/2012, 77 FR 16940 211.6587Thin Particleboard7/27/20113/23/2012, 77 FR 16940 211.6590Thirty Day Rolling Average9/27/19939/9/1994, 59 FR 46562 211.6610Three Piece Can9/27/19939/9/1994, 59 FR 46562 211.6620Three or Four Stage Coating System5/9/19957/25/1996, 61 FR 38577 211.6630Through-the-Valve Fill1/18/199410/21/1996, 61 FR 54556 211.6635Tileboard7/27/20113/23/2012, 77 FR 16940 211.6640Tire Repair9/14/20103/23/2012, 77 FR 16940 211.6650Tooling Resin1/18/199410/21/1996, 61 FR 54556 211.6670Topcoat3/4/20214/11/2023, 88 FR 21490 211.6685Topcoat for General Aviation Rework Facility3/4/20214/11/2023, 88 FR 21490 211.6690Topcoat Operation9/14/20103/23/2012, 77 FR 16940 211.6695Topcoat System5/9/19957/25/1996, 61 FR 38577 211.6710Touch-Up1/18/199410/21/1996, 61 FR 54556 211.6720Touch-Up Coating3/4/20214/11/2023, 88 FR 21490 211.6730Transfer Efficiency9/27/19939/9/1994, 59 FR 46562 211.6740Translucent Coating9/14/20103/23/2012, 77 FR 16940 211.6750Tread End Cementing9/27/19939/9/1994, 59 FR 46562 211.6770True Vapor Pressure9/27/19939/9/1994, 59 FR 46562 211.6780Trunk Interior Coating9/14/20103/23/2012, 77 FR 16940 211.6790Turnaround9/27/19939/9/1994, 59 FR 46562 211.6810Two Piece Can9/27/19939/9/1994, 59 FR 46562 211.6825Underbody Coating9/14/20103/23/2012, 77 FR 16940 211.6830Under-the-Cup Fill1/18/199410/21/1996, 61 FR 54556 211.6850Undertread Cementing9/27/19939/9/1994, 59 FR 46562 211.6860Uniform Finish Blender5/9/19957/25/1996, 61 FR 38577 211.6870Unregulated Safety Relief Valve9/27/19939/9/1994, 59 FR 46562 211.6880Vacuum Metallizing5/9/199510/26/1995, 60 FR 54807 211.6885Vacuum Metalizing Coating9/14/20103/23/2012, 77 FR 16940 211.6890Vacuum Producing System9/27/19939/9/1994, 59 FR 46562 211.6910Vacuum Service9/27/19939/9/1994, 59 FR 46562 211.6930Valves Not Externally Regulated9/27/19939/9/1994, 59 FR 46562 211.6950Vapor Balance System9/27/19939/9/1994, 59 FR 46562 211.6970Vapor Collection System10/25/19944/3/1995, 60 FR 16801 211.6990Vapor Control System10/25/19944/3/1995, 60 FR 16801 211.7010Vapor Mounted Primary Seal9/27/19939/9/1994, 59 FR 46562 211.7030Vapor Recovery System9/27/19939/9/1994, 59 FR 46562 211.7050Vapor-Suppressed Polyester Resin1/18/199410/21/1996, 61 FR 54556 211.7070Vinyl Coating9/27/19939/9/1994, 59 FR 46562 211.7090Vinyl Coating Line9/27/19939/9/1994, 59 FR 46562 211.7110Volatile Organic Liquid (VOL)9/27/19939/9/1994, 59 FR 46562 211.7130Volatile Organic Material Content (VOMC)9/27/19939/9/1994, 59 FR 46562 211.7150Volatile Organic Material (VOM) or Volatile Organic Compound (VOC)10/20/20206/16/2021, 86 FR 31920 211.7170Volatile Petroleum Liquid9/27/19939/9/1994, 59 FR 46562 211.7190Wash Coat9/27/19939/9/1994, 59 FR 46562 211.7200Washoff Operations2/2/19985/19/1998, 63 FR 27489 211.7210Wastewater (Oil/Water) Separator9/27/19939/9/1994, 59 FR 46562 211.7220Waterproof Resorcinol Glue9/14/20103/23/2012, 77 FR 16940 211.7230Weak Nitric Acid Manufacturing Process9/27/19939/9/1994, 59 FR 46562 211.7240Weatherstrip Adhesive9/14/20103/23/2012, 77 FR 16940 211.7250Web9/27/19939/9/1994, 59 FR 46562 211.7260Wet Fastener Installation Coating3/4/20214/11/2023, 88 FR 21490 211.7270Wholesale Purchase Consumer9/27/19939/9/1994, 59 FR 46562 211.7275Wing Coating3/4/20214/11/2023, 88 FR 21490 211.7290Wood Furniture6/25/20103/23/2012, 77 FR 16940 211.7310Wood Furniture Coating9/27/19939/9/1994, 59 FR 46562 211.7330Wood Furniture Coating Line9/27/19939/9/1994, 59 FR 46562 211.7350Woodworking9/27/19939/9/1994, 59 FR 46562 Part 212: Visible and Particulate Matter EmissionsSubpart A: General212.107Measurement Method for Visible Emissions5/22/19963/11/1998, 63 FR 11842 212.108Measurement Methods for PM-10 Emissions and Condensible PM-10 Emissions5/22/19963/11/1998, 63 FR 11842 212.109Measurement Methods for Opacity5/22/19963/11/1998, 63 FR 11842 212.110Measurement Methods for Particulate Matter5/22/19963/11/1998, 63 FR 11842 212.111Abbreviations and Units10/4/199110/21/1993, 58 FR 54291 212.113Incorporations by Reference5/22/19967/14/1999, 64 FR 37847 Subpart B: Visible Emissions212.121Opacity Standards7/13/198812/29/1992, 57 FR 61834 212.122Visible Emissions Limitations for Certain Emission Units for Which Construction or Modification Commenced on or After April 14, 19727/13/198812/29/1992, 57 FR 61834 212.123Visible Emissions Limitations for All Other Emission Units7/13/198812/29/1992, 57 FR 61834 212.124Exceptions7/13/198812/29/1992, 57 FR 61834 212.125Determination of Violations7/13/198812/29/1992, 57 FR 61834 212.126Adjusted Opacity Standards Procedures7/13/198812/29/1992, 57 FR 61834 Subpart D: Particulate Matter Emissions From Incinerators212.181Limitations for Incinerators6/4/198011/27/1981, 46 FR 57893 212.182Aqueous Waste Incinerators6/4/198011/27/1981, 46 FR 57893 212.183Certain Wood Waste Incinerators6/4/198011/27/1981, 46 FR 57893 212.184Explosive Waste Incinerators6/4/198011/27/1981, 46 FR 57893 212.185Continuous Automatic Stoking Animal Pathological Waste Incinerators12/30/19869/15/1993, 58 FR 48312 Subpart E: Particulate Matter Emissions From Fuel Combustion Emission Units212.201Emission Units for Which Construction or Modification Commenced Prior to April 14, 1972, Using Solid Fuel Exclusively Located in the Chicago Area7/9/198612/29/1992, 57 FR 61834 212.202Emission Units for Which Construction or Modification Commenced Prior to April 14, 1972, Using Solid Fuel Exclusively Located Outside the Chicago Area7/9/198612/29/1992, 57 FR 61834 212.203Controlled Emission Units for Which Construction or Modification Commenced Prior to April 14, 1972, Using Solid Fuel Exclusively7/9/198612/29/1992, 57 FR 61834 212.204Emission Units for Which Construction or Modification Commenced on or After April 14, 1972, Using Solid Fuel Exclusively7/9/198612/29/1992, 57 FR 61834 212.205Coal-Fired Industrial Boilers for Which Construction or Modification Commenced Prior to April 14, 1972, Equipped With Flue Gas Desulfurization Systems10/19/19812/22/1984, 49 FR 6490 212.206Emission Units Using Liquid Fuel Exclusively4/14/19725/31/1972, 37 FR 10842 212.207Emission Units Using More Than One Type of Fuel4/14/19725/31/1972, 37 FR 10842 212.208Aggregation of Emission Units for Which Construction or Modification Commenced Prior to April 14, 19724/14/19725/31/1972, 37 FR 10842 212.210Emissions Limitations for Certain Fuel Combustion Emission Units Located in the Vicinity of Granite City5/22/19967/14/1999, 64 FR 37847 Subpart K: Fugitive Particulate Matter212.301Fugitive Particulate Matter10/26/19792/21/1980, 45 FR 11472 212.302Geographical Areas of Application5/22/19967/14/1999, 64 FR 37847 212.304Storage Piles10/26/19794/26/1982, 47 FR 17814 212.305Conveyor Loading Operations10/26/19794/26/1982, 47 FR 17814 212.306Traffic Areas10/26/19792/21/1980, 45 FR 11472 212.307Materials Collected by Pollution Control Equipment10/26/19792/21/1980, 45 FR 11472 212.308Spraying or Choke-Feeding Required10/26/19792/21/1980, 45 FR 11472 212.309Operating Program5/22/19967/14/1999, 64 FR 37847 212.310Minimum Operating Program10/26/19792/21/1980, 45 FR 11472 212.312Amendment to Operating Program10/26/19792/21/1980, 45 FR 11472 212.313Emission Standard for Particulate Collection Equipment10/26/19792/21/1980, 45 FR 11472 212.314Exception for Excess Wind Speed10/26/19792/21/1980, 45 FR 11472 212.315Covering for Vehicles10/26/19792/21/1980, 45 FR 11472 212.316Emissions Limitations for Emission Units in Certain Areas5/22/19967/14/1999, 64 FR 37847 Subpart L: Particulate Matter Emissions From Process Emission Units212.321Process Emission Units for Which Construction or Modification Commenced on or After April 14, 19729/28/19792/21/1980, 45 FR 11472 212.322Process Emission Units for Which Construction or Modification Commenced Prior to April 14, 19729/28/19792/21/1980, 45 FR 11472 212.323Stock Piles9/28/19792/21/1980, 45 FR 11472 212.324Process Emission Units in Certain Areas5/22/19963/11/1998, 63 FR 11842 Subpart N: Food Manufacturing212.361Corn Wet Milling Processes9/28/19792/21/1980, 45 FR 11472 212.362Emission Units in Certain Areas5/22/19963/11/1998, 63 FR 11842 Subpart O: Petroleum Refining, Petrochemical and Chemical Manufacturing212.381Catalyst Regenerators of Fluidized Catalytic Converters9/28/19792/21/1980, 45 FR 11472 Subpart Q: Stone, Clay, Glass and Concrete Manufacturing212.421Portland Cement Processes for Which Construction or Modification Commenced on or After April 14, 19724/14/19725/31/1972, 37 FR 10842 212.422Portland Cement Manufacturing Processes9/28/19792/21/1980, 45 FR 11472 212.423Emission Limits for the Portland Cement Manufacturing Plant Located in LaSalle County, South of the Illinois River10/4/199110/21/1993, 58 FR 54291 212.424Fugitive Particulate Matter Control for the Portland Cement Manufacturing Plant and Associated Quarry Operations Located in LaSalle County, South of the Illinois River5/15/19921/12/1993, 58 FR 3844 212.425Emission Units in Certain Areas5/22/19963/11/1998, 63 FR 11842 Subpart R: Primary and Fabricated Metal Products and Machinery Manufacture212.441Steel Manufacturing Processes9/28/19792/21/1980, 45 FR 11472 212.442Beehive Coke Ovens9/28/19792/21/1980, 45 FR 11472 212.443Coke Plants5/15/19921/12/1993, 58 FR 3844 212.444Sinter Processes9/28/19799/3/1981, 46 FR 44172 212.445Blast Furnace Cast Houses5/15/19921/12/1993, 58 FR 3844 212.446Basic Oxygen Furnaces5/22/19963/11/1998, 63 FR 11842 212.447Hot Metal Desulfurization Not Located in the BOF9/28/19799/3/1981, 46 FR 44172 212.448Electric Arc Furnaces9/28/19799/3/1981, 46 FR 44172 212.449Argon-Oxygen Decarburization Vessels9/28/19799/3/1981, 46 FR 44172 212.450Liquid Steel Charging9/28/19799/3/1981, 46 FR 44172 212.451Hot Scarfing Machines9/28/19799/3/1981, 46 FR 44172 212.455Highlines on Steel Mills10/26/19792/21/1980, 45 FR 11472 212.456Certain Small Foundries9/28/19792/21/1980, 45 FR 11472 212.457Certain Small Iron-Melting Air Furnaces9/28/19797/12/1982, 47 FR 30057 212.458Emission Units in Certain Areas5/22/19963/11/1998, 63 FR 11842 Subpart S: Agriculture212.461Grain-Handling and Drying in General9/28/19792/21/1980, 45 FR 11472 212.462Grain-Handling Operations9/28/19792/21/1980, 45 FR 11472 212.463Grain Drying Operations9/28/19792/21/1980, 45 FR 11472 212.464Sources in Certain Areas5/22/19963/11/1998, 63 FR 11842 Subpart T: Construction and Wood Products212.681Grinding, Woodworking, Sandblasting and Shotblasting4/14/19725/31/1972, 37 FR 10842 Subpart U: Additional Control Measures212.700Applicability7/11/19947/13/1995, 60 FR 36060 212.701Contingency Measure Plans, Submittal and Compliance Date7/11/19947/13/1995, 60 FR 36060 212.702Determination of Contributing Sources7/11/19947/13/1995, 60 FR 36060 212.703Contingency Measure Plan Elements7/11/19947/13/1995, 60 FR 36060 212.704Implementation7/11/19947/13/1995, 60 FR 36060 212.705Alternative Implementation7/11/19947/13/1995, 60 FR 36060 212.Appendix C:Past Compliance Dates4/14/19725/31/1972, 37 FR 10842Approved as Rules 202(e), 203(c), 203(d)(3)(A) & (B), 203(d)(5)(L) & (M), 203(d)(8)(J), 203(f)(3) Preamble, 203(f)(3)(F) Preamble, and 203(i). Part 214: Sulfur LimitationsSubpart A: General Provisions214.101Measurement Methods12/7/20152/1/2018, 83 FR 4591 214.102Abbreviations and Units12/7/20152/1/2018, 83 FR 4591 214.103Definitions12/7/20152/1/2018, 83 FR 4591 214.104Incorporations by Reference12/7/20152/1/2018, 83 FR 4591 Subpart B: New Fuel Combustion Emission Sources214.121Large Sources12/7/20152/1/2018, 83 FR 4591 214.122Small Sources12/7/20152/1/2018, 83 FR 4591 Subpart C: Existing Solid Fuel Combustion Emission Sources214.141Sources Located in Metropolitan Areas3/28/19839/3/1992, 57 FR 40333thru (a). 214.141Sources Located in Metropolitan Areas5/20/19869/2/1992, 57 FR 40126(b), (c), and (d). 214.142Small Sources Located Outside Metropolitan Areas4/14/19725/31/1972, 37 FR 10842Approved as Rule 204(c)(1)(B). 214.143Large Sources Located Outside Metropolitan Areas2/3/19792/21/1980, 45 FR 11472 Subpart D: Existing Liquid or Mixed Fuel Combustion Emission Sources214.161Liquid Fuel Burned Exclusively12/7/20152/1/2018, 83 FR 4591 214.162Combination of Fuels12/7/20152/1/2018, 83 FR 4591 Subpart E: Aggregation of Sources Outside Metropolitan Areas214.181Dispersion Enhancement Techniques2/3/19792/21/1980, 45 FR 11472 214.182Prohibition2/3/19792/21/1980, 45 FR 11472Approved as Rule 204(e) (intro). 214.183General Formula2/3/19792/21/1980, 45 FR 11472Approved as Rule 204(e)(1). 214.184Special Formula2/3/19792/21/1980, 45 FR 11472Approved as Rule 204(e)(2). 214.185Alternative Emission Rate2/3/19792/21/1980, 45 FR 11472Approved as Rule 204(e)(3). 214.186New Operating Permits2/3/19792/21/1980, 45 FR 11472Approved as Rule 204(e)(4). Subpart F: Alternative Standards for Sources Inside Metropolitan Areas214.201Alternative Standards for Sources in Metropolitan Areas12/7/20152/1/2018, 83 FR 4591 214.202Dispersion Enhancement Techniques3/28/19839/3/1992, 57 FR 40333 Subpart K: Process Emission Sources214.300Scope12/7/20152/1/2018, 83 FR 4591 214.301General Limitation2/3/19792/21/1980, 45 FR 11472Approved as Rule 204(f)(1)(A). 214.302Exception for Air Pollution Control Equipment4/14/19725/31/1972, 37 FR 10842Approved as Rule 204(f)(1)(C). 214.303Use of Sulfuric Acid2/3/19792/21/1980, 45 FR 11472Approved as Rule 204(f)(2)(B). 214.305Fuel Sulfur Content Limitations12/7/20152/1/2018, 83 FR 4591 Subpart O: Petroleum Refining, Petrochemical and Chemical Manufacturing214.381Sulfuric Acid Manufacturing2/3/19792/21/1980, 45 FR 11472Only (a) and (b). Approved as Rule 204(f)(1)(B) and (f)(2)(A). 214.382Petroleum and Petrochemical Processes12/5/19881/28/1994, 59 FR 4001 214.383Chemical Manufacturing2/3/19792/21/1980, 45 FR 11472Approved as Rule 204(f)(1)(E). Subpart Q: Primary and Secondary Metal Manufacturing214.421Combination of Fuels at Steel Mills in Metropolitan Areas12/7/20152/1/2018, 83 FR 4591 Subpart X: Utilities214.560Scope5/20/19869/2/1992, 57 FR 40126 214.561E. D. Edwards Electric Generating Station7/11/200311/10/2008, 73 FR 66555 Subpart AA: Requirements for Certain SO2 Sources214.600Definitions12/7/20152/1/2018, 83 FR 4591 214.601Applicability12/7/20152/1/2018, 83 FR 4591 214.602Compliance Deadline12/7/20152/1/2018, 83 FR 4591 214.603Emission Limitations12/7/20152/1/2018, 83 FR 4591 214.604Monitoring and Testing12/7/20152/1/2018, 83 FR 4591 214.605Recordkeeping and Reporting12/7/20152/1/2018, 83 FR 4591 214.Appendix C:Compliance Dates4/14/19725/31/1972, 37 FR 10842Approved as Rule 204(e)(1). Part 215: Organic Material Emission Standards and LimitationsSubpart A: General Provisions215.101Clean-Up and Disposal Operations7/28/19792/21/1980, 45 FR 11472 215.102Testing Methods5/14/19918/18/1992, 57 FR 37100 215.104Definitions1/28/201310/6/2014, 79 FR 60070 215.105Incorporation by Reference1/28/201310/6/2014, 79 FR 60070 215.108Measurement of Vapor Pressures5/14/19918/18/1992, 57 FR 37100 215.109Monitoring for Negligibly-Reactive Compounds6/19/19981/15/1999, 64 FR 2581 Subpart B: Organic Emissions From Storage and Loading Operations215.121Storage Containers7/28/19792/21/1980, 45 FR 11472 215.122Loading Operations7/28/19792/21/1980, 45 FR 11472 215.123Petroleum Liquid Storage Tanks7/28/19792/21/1980, 45 FR 11472 215.124External Floating Roofs1/21/19836/29/1990, 55 FR 26814 215.125Compliance Dates and Geographical Areas1/21/19836/29/1990, 55 FR 26814 215.126Compliance Plan1/21/19836/29/1990, 55 FR 26814 Subpart C: Organic Emissions From Miscellaneous Equipment215.141Separation Operations7/28/19792/21/1980, 45 FR 11472 215.142Pumps and Compressors7/28/19792/21/1980, 45 FR 11472 215.143Vapor Blowdown7/28/19792/21/1980, 45 FR 11472 215.144Safety Relief Valves7/28/19792/21/1980, 45 FR 11472 Subpart E: Solvent Cleaning215.181Solvent Cleaning in General7/28/19792/21/1980, 45 FR 11472 215.182Cold Cleaning7/28/19792/21/1980, 45 FR 11472 215.183Open Top Vapor Degreasing7/28/19792/21/1980, 45 FR 11472 215.184Conveyorized Degreasing7/28/19792/21/1980, 45 FR 11472 Subpart F: Coating Operations215.202Compliance Schedules7/28/19792/21/1980, 45 FR 11472 215.204Emission Limitations for Manufacturing Plants6/19/19981/15/1999, 64 FR 2581 215.205Alternative Emission Limitations6/19/19981/15/1999, 64 FR 2581 215.206Exemptions From Emission Limitations6/19/19981/15/1999, 64 FR 2581 215.207Compliance by Aggregation of Emission Units6/19/19981/15/1999, 64 FR 2581 215.208Testing Methods for Volatile Organic Material Content7/28/19792/21/1980, 45 FR 11472 215.209Exemption From General Rule on Use of Organic Material7/28/19792/21/1980, 45 FR 11472 215.211Compliance Dates and Geographical Areas6/19/19981/15/1999, 64 FR 2581 215.212Compliance Plan6/19/19981/15/1999, 64 FR 2581 215.213Special Requirements for Compliance Plan7/28/19792/21/1980, 45 FR 11472 215.215DMI Emissions Limitations7/28/19792/21/1980, 45 FR 11472 Subpart H: Special Limitations for Sources in Major Urbanized Areas Which Are Nonattainment for Ozone215.240Applicability6/29/19876/29/1990, 55 FR 26814 215.241External Floating Roofs6/29/19876/29/1990, 55 FR 26814 215.249Compliance Dates6/29/19876/29/1990, 55 FR 26814 Subpart K: Use of Organic Material215.301Use of Organic Material7/28/19792/21/1980, 45 FR 11472 215.302Alternative Standard7/28/19792/21/1980, 45 FR 11472 215.303Fuel Combustion Emission Sources7/28/19792/21/1980, 45 FR 11472 215.304Operations With Compliance Program7/28/19792/21/1980, 45 FR 11472 Subpart P: Printing and Publishing215.408Heatset Web Offset Lithographic Printing9/30/19876/29/1990, 55 FR 26814 Subpart Q: Leaks From Synthetic Organic Chemical and Polymer Manufacturing Equipment215.420Applicability12/14/19876/29/1990, 55 FR 26814 215.421General Requirements12/14/19876/29/1990, 55 FR 26814 215.422Inspection Program Plan for Leaks8/28/19856/29/1990, 55 FR 26814 215.423Inspection Program for Leaks8/28/19856/29/1990, 55 FR 26814 215.424Repairing Leaks8/28/19856/29/1990, 55 FR 26814 215.425Recordkeeping for Leaks8/28/19856/29/1990, 55 FR 26814 215.426Reporting for Leaks8/28/19856/29/1990, 55 FR 26814 215.427Alternative Program for Leaks8/28/19856/29/1990, 55 FR 26814 215.428Compliance Dates12/14/19876/29/1990, 55 FR 26814 215.429Compliance Plan12/14/19876/29/1990, 55 FR 26814 215.430General Requirements12/14/19876/29/1990, 55 FR 26814 215.431Inspection Program Plan for Leaks12/14/19876/29/1990, 55 FR 26814 215.433Repairing Leaks12/14/19876/29/1990, 55 FR 26814 215.434Recordkeeping for Leaks12/14/19876/29/1990, 55 FR 26814 215.435Report for Leaks12/14/19876/29/1990, 55 FR 26814 215.437Open-Ended Valves12/14/19876/29/1990, 55 FR 26814 215.438Compliance Plan12/14/19876/29/1990, 55 FR 26814 Subpart R: Petroleum Refining and Related Industries; Asphalt Materials215.441Petroleum Refinery Waste Gas Disposal7/28/19792/21/1980, 45 FR 11472 215.442Vacuum Producing Systems7/28/19792/21/1980, 45 FR 11472 215.443Wastewater (Oil/Water) Separator7/28/19792/21/1980, 45 FR 11472 215.444Process Unit Turnarounds7/28/19792/21/1980, 45 FR 11472 215.445Leaks: General Requirements1/21/198311/27/1987, 52 FR 45333 215.446Monitoring Program Plan for Leaks1/21/198311/27/1987, 52 FR 45333 215.447Monitoring Program for Leaks1/21/198311/27/1987, 52 FR 45333 215.448Recordkeeping for Leaks1/21/198311/27/1987, 52 FR 45333 215.449Reporting for Leaks1/21/198311/27/1987, 52 FR 45333 215.450Alternative Program for Leaks1/21/198311/27/1987, 52 FR 45333 215.451Sealing Device Requirements1/21/198311/27/1987, 52 FR 45333 215.453Compliance Dates and Geographical Areas1/21/19836/29/1990, 55 FR 26814 Subpart S: Rubber and Miscellaneous Plastic Products215.461Manufacture of Pneumatic Rubber Tires1/21/198311/27/1987, 52 FR 45333 215.462Green Tire Spraying Operations1/21/198311/27/1987, 52 FR 45333 215.463Alternative Emission Reduction Systems1/21/198311/27/1987, 52 FR 45333 215.464Emissions Testing1/21/198311/27/1987, 52 FR 45333 215.465Compliance Dates and Geographical Areas1/21/19836/29/1990, 55 FR 26814 215.466Compliance Plan1/21/19836/29/1990, 55 FR 26814 Subpart T: Pharmaceutical Manufacturing215.480Applicability of Subpart T5/14/19918/18/1992, 57 FR 37100 215.481Control of Reactors, Distillation Units, Crystallizers, Centrifuges and Vacuum Dryers5/14/19918/18/1992, 57 FR 37100 215.482Control of Air Dryers, Production Equipment Exhaust Systems and Filters5/14/19918/18/1992, 57 FR 37100 215.483Material Storage and Transfer5/14/19918/18/1992, 57 FR 37100 215.484In-Process Tanks5/14/19918/18/1992, 57 FR 37100 215.485Leaks5/14/19918/18/1992, 57 FR 37100 215.486Other Emission Sources5/14/19918/18/1992, 57 FR 37100 215.487Testing5/14/19918/18/1992, 57 FR 37100 215.488Monitors for Air Pollution Control Equipment5/14/19918/18/1992, 57 FR 37100 215.489Recordkeeping (Renumbered)5/14/19918/18/1992, 57 FR 37100 215.490Compliance Schedule (Renumbered)5/14/19918/18/1992, 57 FR 37100 Subpart V: Air Oxidation Processes215.520Applicability12/14/19876/29/1990, 55 FR 26814 215.521Definitions12/14/19876/29/1990, 55 FR 26814 215.525Emission Limitations for Air Oxidation Processes12/14/19876/29/1990, 55 FR 26814 215.526Testing and Monitoring12/14/19876/29/1990, 55 FR 26814 215.527Compliance Date12/14/19876/29/1990, 55 FR 26814 Subpart W: Agriculture215.541Pesticide Exception7/28/19792/21/1980, 45 FR 11472 Subpart X: Construction215.561Architectural Coatings7/28/19792/21/1980, 45 FR 11472 215.562Paving Operations7/28/19792/21/1980, 45 FR 11472 215.563Cutback Asphalt7/28/19792/21/1980, 45 FR 11472 Subpart Y: Gasoline Distribution215.581Bulk Gasoline Plants7/28/19792/21/1980, 45 FR 11472 215.582Bulk Gasoline Terminals6/29/19876/29/1990, 55 FR 26814 215.583Gasoline Dispensing Facilities—Storage Tank Filling Operations6/29/19876/29/1990, 55 FR 26814 215.584Gasoline Delivery Vessels6/29/19876/29/1990, 55 FR 26814 Subpart Z: Dry Cleaners215.607Standards for Petroleum Solvent Dry Cleaners4/3/19876/29/1990, 55 FR 26814 215.608Operating Practices for Petroleum Solvent Dry Cleaners4/3/19876/29/1990, 55 FR 26814 215.609Program for Inspection and Repair of Leaks4/3/19876/29/1990, 55 FR 26814 215.610Testing and Monitoring4/3/19876/29/1990, 55 FR 26814 215.611Exemption for Petroleum Solvent Dry Cleaners4/3/19876/29/1990, 55 FR 26814 215.612Compliance Dates and Geographical Areas4/3/19876/29/1990, 55 FR 26814 215.613Compliance Plan4/3/19876/29/1990, 55 FR 26814 Subpart BB: Polystyrene Plants215.875Applicability of Subpart BB9/30/19876/29/1990, 55 FR 26814 215.877Emissions Limitation at Polystyrene Plants9/30/19876/29/1990, 55 FR 26814 215.879Compliance Date9/30/19876/29/1990, 55 FR 26814 215.881Compliance Plan9/30/19876/29/1990, 55 FR 26814 215.883Special Requirements for Compliance Plan9/30/19876/29/1990, 55 FR 26814 215.886Emissions Testing9/30/19876/29/1990, 55 FR 26814 215.Appendix C:Past Compliance Dates7/28/19792/21/1980, 45 FR 11472Approved as Rules 104(a), 104(g), 104(h), 205(j), and 205(m). Part 216: Carbon Monoxide EmissionsSubpart A: General Provisions216.101Measurement Methods7/28/19792/21/1980, 45 FR 11472Approved as Rule 206(f). Subpart B: Fuel Combustion Emission Sources216.121Fuel Combustion Emission Sources7/28/19792/21/1980, 45 FR 11472Approved as Rule 206(a). Subpart C: Incinerators216.141Incinerators7/28/19792/21/1980, 45 FR 11472Approved as Rule 206(b). 216.142Exceptions7/28/19792/21/1980, 45 FR 11472Approved as Rule 206(b)(1,2). Subpart N: Petroleum Refining and Chemical Manufacture216.361Petroleum and Petrochemical Processes7/28/19792/21/1980, 45 FR 11472Approved as Rule 206(c). 216.362Polybasic Organic Acid Partial Oxidation Manufacturing Processes7/28/19792/21/1980, 45 FR 11472Approved as Rule 206(h). Subpart O: Primary and Fabricated Metal Products216.381Cupolas7/28/19792/21/1980, 45 FR 11472Approved as Rule 206(e). 216.382Exception, General Motor's Ferrous Foundry in Vermilion County11/13/19928/4/1994, 59 FR 39686 216.Appendix C:Compliance Dates7/28/19792/21/1980, 45 FR 11472Approved as Rule 206(g). Part 217: Nitrogen Oxides EmissionsSubpart A: General Provisions217.101Measurement Methods9/25/20076/26/2009, 74 FR 30466 217.102Abbreviations and Units9/25/20076/26/2009, 74 FR 30466 217.104Incorporations by Reference9/25/20076/26/2009, 74 FR 30466 Subpart B: New Fuel Combustion Emission Sources217.121New Emission Sources4/14/19725/31/1972, 37 FR 10862Approved as Rule 207(a)(1)-(4), 207(a)(5)(A). Subpart C: Existing Fuel Combustion Emission Sources217.141Existing Emission Sources in Major Metropolitan Areas4/14/19725/31/1972, 37 FR 10862Approved as Rule 207(b) and (c). Subpart K: Process Emission Sources217.301Industrial Processes4/14/19725/31/1972, 37 FR 10862Approved as Rule 207(e). Subpart O: Chemical Manufacture217.381Nitric Acid Manufacturing Processes4/14/19725/31/1972, 37 FR 10862Approved as Rule 207(d). Subpart Q: Stationary Reciprocating Internal Combustion Engines and Turbines217.386Applicability9/25/20076/26/2009, 74 FR 30466 217.388Control and Maintenance Requirements9/25/20076/26/2009, 74 FR 30466 217.390Emissions Averaging Plans9/25/20076/26/2009, 74 FR 30466 217.392Compliance9/25/20076/26/2009, 74 FR 30466 217.394Testing and Monitoring9/25/20076/26/2009, 74 FR 30466 217.396Recordkeeping and Reporting9/25/20076/26/2009, 74 FR 30466 Subpart T: Cement Kilns217.400Applicability3/15/200111/8/2001, 66 FR 56449 217.402Control Requirements3/15/200111/8/2001, 66 FR 56449 217.404Testing3/15/200111/8/2001, 66 FR 56449 217.406Monitoring3/15/200111/8/2001, 66 FR 56449 217.408Reporting3/15/200111/8/2001, 66 FR 56449 217.410Recordkeeping3/15/200111/8/2001, 66 FR 56449 Subpart U: NOX Control and Trading Program for Specified NOX Generating Units217.450Purpose4/17/200111/8/2001, 66 FR 56449 217.452Severability4/17/200111/8/2001, 66 FR 56449 217.454Applicability4/17/200111/8/2001, 66 FR 56449 217.456Compliance Requirements4/17/200111/8/2001, 66 FR 56449 217.458Permitting Requirements4/17/200111/8/2001, 66 FR 56449 217.460Subpart U NOX Trading Budget4/17/200111/8/2001, 66 FR 56449 217.462Methodology for Obtaining NOX Allocations4/17/200111/8/2001, 66 FR 56449 217.464Methodology for Determining NOX Allowances From the New Source Set-Aside4/17/200111/8/2001, 66 FR 56449 217.466NOX Allocations Procedure for Subpart U Budget Units4/17/200111/8/2001, 66 FR 56449 217.468New Source Set-Asides for “New” Budget Units4/17/200111/8/2001, 66 FR 56449 217.470Early Reduction Credits (ERCS) for Budget Units4/17/200111/8/2001, 66 FR 56449 217.472Low-Emitter Requirements4/17/200111/8/2001, 66 FR 56449 217.474Opt-In Units4/17/200111/8/2001, 66 FR 56449 217.476Opt-In Process4/17/200111/8/2001, 66 FR 56449 217.478Opt-In Budget Units: Withdrawal From NOX Trading Program4/17/200111/8/2001, 66 FR 56449 217.480Opt-In Units: Change in Regulatory Status4/17/200111/8/2001, 66 FR 56449 217.482Allowance Allocations To Opt-In Budget Units4/17/200111/8/2001, 66 FR 56449 Subpart V: Electric Power Generation217.521Lake of Egypt Power Plant4/13/19786/18/2001, 66 FR 32769 217.700Purpose4/17/20016/18/2001, 66 FR 32769 217.702Severability4/17/20016/18/2001, 66 FR 32769 217.704Applicability4/17/20016/18/2001, 66 FR 32769 217.706Emission Limitations4/17/20016/18/2001, 66 FR 32769 217.708NOX Averaging4/17/20016/18/2001, 66 FR 32769 217.710Monitoring4/17/20016/18/2001, 66 FR 32769 217.712Reporting and Recordkeeping4/17/20016/18/2001, 66 FR 32769 Subpart W: NOX Trading Program for Electrical Generating Units217.750Purpose12/26/200011/8/2001, 66 FR 56454 217.751Sunset Provisions11/2/20093/1/2010, 75 FR 9103 217.752Severability12/26/200011/8/2001, 66 FR 56454 217.754Applicability12/26/200011/8/2001, 66 FR 56454 217.756Compliance Requirements12/26/200011/8/2001, 66 FR 56454Except (d)(3). 217.758Permitting Requirements12/26/200011/8/2001, 66 FR 56454 217.760NOx Trading Budget12/26/200011/8/2001, 66 FR 56454 217.762Methodology for Calculating NOX Allocations for Budget Electrical Generating Units (EGUs)12/26/200011/8/2001, 66 FR 56454 217.764NOX Allocations for Budget EGUs12/26/200011/8/2001, 66 FR 56454 217.768New Source Set-Asides for “New” Budget EGUs12/26/200011/8/2001, 66 FR 56454 217.770Early Reduction Credits for Budget EGUs12/26/200011/8/2001, 66 FR 56454 217.774Opt-In Units12/26/200011/8/2001, 66 FR 56454 217.776Opt-In Process12/26/200011/8/2001, 66 FR 56454 217.778Budget Opt-In Units: Withdrawal From NOX Trading Program12/26/200011/8/2001, 66 FR 56454 217.780Opt-In Units: Change in Regulatory Status12/26/200011/8/2001, 66 FR 56454 217.782Allowance Allocations to Budget Opt-In Units12/26/200011/8/2001, 66 FR 56454 217.Appendix C:Compliance Dates4/14/19725/31/1972, 37 FR 10862 217.Appendix G:Existing Reciprocating Internal Combustion Engines Affected by the NOX Sip Call9/25/20076/26/2009, 74 FR 30466 Part 218: Organic Material Emission Standards and Limitations for the Chicago AreaSubpart A: General Provisions218.100Introduction9/27/19939/9/1994, 59 FR 46562 218.101Savings Clause10/25/19944/3/1995, 60 FR 16801 218.102Abbreviations and Conversion Factors9/27/19939/9/1994, 59 FR 46562 218.103Applicability9/27/19939/9/1994, 59 FR 46562 218.104Definitions9/27/19939/9/1994, 59 FR 46562 218.105Test Methods and Procedures7/27/20113/23/2012, 77 FR 16940 218.106Compliance Dates9/14/20103/23/2012, 77 FR 16940 218.107Operation of Afterburners9/27/19939/9/1994, 59 FR 46562 218.108Exemptions, Variations, and Alternative Means of Control or Compliance Determinations1/24/199410/21/1996, 61 FR 54556 218.109Vapor Pressure of Volatile Organic Liquids9/27/19939/9/1994, 59 FR 46562 218.110Vapor Pressure of Organic Material or Solvent9/27/19939/9/1994, 59 FR 46562 218.111Vapor Pressure of Volatile Organic Material9/27/19939/9/1994, 59 FR 46562 218.112Incorporations by Reference12/23/20133/13/2015, 80 FR 13248 218.114Compliance With Permit Conditions1/24/199410/21/1996, 61 FR 54556 Subpart B: Organic Emissions From Storage and Loading Operations218.119Applicability for VOL11/15/19948/8/1996, 61 FR 41338 218.120Control Requirements for Storage Containers of VOL11/15/19948/8/1996, 61 FR 41338 218.121Storage Containers9/27/19939/9/1994, 59 FR 46562 218.122Loading Operations9/27/19939/9/1994, 59 FR 46562 218.123Petroleum Liquid Storage Tanks9/27/19939/9/1994, 59 FR 46562 218.124External Floating Roofs9/27/19939/9/1994, 59 FR 46562 218.125Compliance Dates11/15/19948/8/1996, 61 FR 41338 218.127Testing VOL Operations11/15/19948/8/1996, 61 FR 41338 218.128Monitoring VOL Operations1/28/201310/6/2014, 79 FR 60070 218.129Recordkeeping and Reporting for VOL Operations11/15/19948/8/1996, 61 FR 41338 Subpart C: Organic Emissions From Miscellaneous Equipment218.141Separation Operations9/27/19939/9/1994, 59 FR 46562 218.142Pumps and Compressors8/16/19919/9/1994, 59 FR 46562 218.143Vapor Blowdown9/27/19939/9/1994, 59 FR 46562 218.144Safety Relief Valves9/27/19939/9/1994, 59 FR 46562 Subpart E: Solvent Cleaning218.181Solvent Cleaning Degreasing Operations6/25/20103/23/2012, 77 FR 16940 218.182Cold Cleaning6/9/199711/26/1997, 62 FR 62951 218.183Open Top Vapor Degreasing9/27/19939/9/1994, 59 FR 46562 218.184Conveyorized Degreasing9/27/19939/9/1994, 59 FR 46562 218.186Test Methods9/27/19939/9/1994, 59 FR 46562 218.187Other Industrial Solvent Cleaning Operations7/27/20113/23/2012, 77 FR 16940 Subpart F: Coating Operations218.204Emission Limitations7/27/20113/23/2012, 77 FR 16940 218.205Daily-Weighted Average Limitations9/14/20103/23/2012, 77 FR 16940 218.206Solids Basis Calculation9/27/19939/9/1994, 59 FR 46562 218.207Alternative Emission Limitations7/27/20113/23/2012, 77 FR 16940 218.208Exemptions From Emission Limitations10/25/20114/19/2013, 78 FR 23495 218.209Exemption From General Rule on Use of Organic Material9/27/19939/9/1994, 59 FR 46562 218.210Compliance Schedule6/25/20103/23/2012, 77 FR 16940 218.211Recordkeeping and Reporting7/27/20113/23/2012, 77 FR 16940 218.212Cross-Line Averaging To Establish Compliance for Coating Lines9/14/20103/23/2012, 77 FR 16940 218.213Recordkeeping and Reporting for Cross-Line Averaging Participating Coating Lines5/9/19952/13/1996, 61 FR 5511 218.214Changing Compliance Methods5/9/19952/13/1996, 61 FR 5511 218.215Wood Furniture Coating Averaging Approach2/2/19985/19/1998, 63 FR 27489 218.216Wood Furniture Coating Add-On Control Use2/2/19985/19/1998, 63 FR 27489 218.217Wood Furniture Coating and Flat Wood Paneling Coating Work Practice Standards7/27/20113/23/2012, 77 FR 16940 218.218Work Practice Standards for Paper Coatings, Metal Furniture Coatings, and Large Appliance Coatings3/23/20103/23/2012, 77 FR 16940 218.219Work Practice Standards for Automobile and Light-Duty Truck Assembly Coatings and Miscellaneous Metal and Plastic Parts Coatings9/14/20103/23/2012, 77 FR 16940 Subpart G: Use of Organic Material218.301Use of Organic Material9/27/19939/9/1994, 59 FR 46562 218.302Alternative Standard9/27/19939/9/1994, 59 FR 46562 218.303Fuel Combustion Emission Units9/27/19939/9/1994, 59 FR 46562 218.304Operations With Compliance Program9/27/19939/9/1994, 59 FR 46562 Subpart H: Printing and Publishing218.401Flexographic and Rotogravure Printing7/27/20113/23/2012, 77 FR 16940 218.402Applicability7/27/20113/23/2012, 77 FR 16940 218.403Compliance Schedule6/25/20103/23/2012, 77 FR 16940 218.404Recordkeeping and Reporting7/27/20113/23/2012, 77 FR 16940 218.405Lithographic Printing: Applicability6/25/20103/23/2012, 77 FR 16940 218.407Emission Limitations and Control Requirements for Lithographic Printing Lines6/25/20103/23/2012, 77 FR 16940 218.409Testing for Lithographic Printing on and After March 15, 19967/27/20113/23/2012, 77 FR 16940 218.410Monitoring Requirements for Lithographic Printing6/25/20103/23/2012, 77 FR 16940 218.411Recordkeeping and Reporting for Lithographic Printing7/27/20113/23/2012, 77 FR 16940 218.412Letterpress Printing Lines: Applicability6/25/20103/23/2012, 77 FR 16940 218.413Emission Limitations and Control Requirements for Letterpress Printing Lines6/25/20103/23/2012, 77 FR 16940 218.415Testing for Letterpress Printing Lines7/27/20113/23/2012, 77 FR 16940 218.416Monitoring Requirements for Letterpress Printing Lines6/25/20103/23/2012, 77 FR 16940 218.417Recordkeeping and Reporting for Letterpress Printing Lines7/27/20113/23/2012, 77 FR 16940 Subpart Q: Synthetic Organic Chemical and Polymer Manufacturing Plant218.421General Requirements9/27/19939/9/1994, 59 FR 46562 218.422Inspection Program Plan for Leaks9/27/19939/9/1994, 59 FR 46562 218.423Inspection Program for Leaks9/27/19939/9/1994, 59 FR 46562 218.424Repairing Leaks9/27/19939/9/1994, 59 FR 46562 218.425Recordkeeping for Leaks9/27/19939/9/1994, 59 FR 46562 218.426Report for Leaks9/27/19939/9/1994, 59 FR 46562 218.427Alternative Program for Leaks9/27/19939/9/1994, 59 FR 46562 218.428Open-Ended Valves9/27/19939/9/1994, 59 FR 46562 218.429Standards for Control Devices9/27/19939/9/1994, 59 FR 46562 218.431Applicability5/9/19953/23/1998, 63 FR 13784 218.432Control Requirements5/9/19953/23/1998, 63 FR 13784 218.433Performance and Testing Requirements5/9/19953/23/1998, 63 FR 13784 218.434Monitoring Requirements5/9/19953/23/1998, 63 FR 13784 218.435Recordkeeping and Reporting Requirements5/9/19953/23/1998, 63 FR 13784 218.436Compliance Date5/9/19953/23/1998, 63 FR 13784 Subpart R: Petroleum Refining and Related Industries; Asphalt Materials218.441Petroleum Refinery Waste Gas Disposal9/27/19939/9/1994, 59 FR 46562 218.442Vacuum Producing Systems8/16/19919/9/1994, 59 FR 46562 218.443Wastewater (Oil/Water) Separator9/27/19939/9/1994, 59 FR 46562 218.444Process Unit Turnarounds8/16/19919/9/1994, 59 FR 46562 218.445Leaks: General Requirements9/27/19939/9/1994, 59 FR 46562 218.446Monitoring Program Plan for Leaks9/27/19939/9/1994, 59 FR 46562 218.447Monitoring Program for Leaks9/27/19939/9/1994, 59 FR 46562 218.448Recordkeeping for Leaks8/16/19919/9/1994, 59 FR 46562 218.449Reporting for Leaks9/27/19939/9/1994, 59 FR 46562 218.450Alternative Program for Leaks9/27/19939/9/1994, 59 FR 46562 218.451Sealing Device Requirements8/16/19919/9/1994, 59 FR 46562 218.452Compliance Schedule for Leaks9/27/19939/9/1994, 59 FR 46562 Subpart S: Rubber and Miscellaneous Plastic Products218.461Manufacture of Pneumatic Rubber Tires9/27/19939/9/1994, 59 FR 46562 218.462Green Tire Spraying Operations9/27/19939/9/1994, 59 FR 46562 218.463Alternative Emission Reduction Systems9/27/19939/9/1994, 59 FR 46562 218.464Emission Testing9/27/19939/9/1994, 59 FR 46562 Subpart T: Pharmaceutical Manufacturing218.480Applicability8/26/200811/3/2010, 75 FR 67623 218.481Control of Reactors, Distillation Units, Crystallizers, Centrifuges and Vacuum Dryers9/27/19939/9/1994, 59 FR 46562 218.482Control of Air Dryers, Production Equipment Exhaust Systems and Filters9/27/19939/9/1994, 59 FR 46562 218.483Material Storage and Transfer9/27/19939/9/1994, 59 FR 46562 218.484In-Process Tanks8/16/19919/9/1994, 59 FR 46562 218.485Leaks9/27/19939/9/1994, 59 FR 46562 218.486Other Emission Units9/27/19939/9/1994, 59 FR 46562 218.487Testing9/27/19939/9/1994, 59 FR 46562 218.488Monitoring for Air Pollution Control Equipment8/16/19919/9/1994, 59 FR 46562 218.489Recordkeeping for Air Pollution Control Equipment9/27/19939/9/1994, 59 FR 46562 Subpart V: Batch Operations and Air Oxidation Processes218.500Applicability for Batch Operations5/22/19954/2/1996, 61 FR 14484 218.501Control Requirements for Batch Operations5/22/19954/2/1996, 61 FR 14484 218.502Determination of Uncontrolled Total Annual Mass Emissions and Average Flow Rate Values for Batch Operations5/22/19954/2/1996, 61 FR 14484 218.503Performance and Testing Requirements for Batch Operations5/22/19954/2/1996, 61 FR 14484 218.504Monitoring Requirements for Batch Operations5/22/19954/2/1996, 61 FR 14484 218.505Reporting and Recordkeeping for Batch Operations5/22/19954/2/1996, 61 FR 14484 218.506Compliance Date5/22/19954/2/1996, 61 FR 14484 218.520Emission Limitations for Air Oxidation Processes11/15/19949/27/1995, 60 FR 49770 218.522Savings Clause11/15/19949/27/1995, 60 FR 49770 218.523Compliance11/15/19949/27/1995, 60 FR 49770 218.524Determination of Applicability11/15/19949/27/1995, 60 FR 49770 218.525Emission Limitations for Air Oxidation Processes11/15/19949/27/1995, 60 FR 49770 218.526Testing and Monitoring8/16/19919/9/1994, 59 FR 46562 Subpart W: Agriculture218.541Pesticide Exception9/27/19939/9/1994, 59 FR 46562 Subpart X: Construction218.561Architectural Coatings8/16/19919/9/1994, 59 FR 46562 218.562Paving Operations9/27/19939/9/1994, 59 FR 46562 218.563Cutback Asphalt8/16/19919/9/1994, 59 FR 46562 Subpart Y: Gasoline Distribution218.581Bulk Gasoline Plants9/27/19939/9/1994, 59 FR 46562 218.582Bulk Gasoline Terminals9/27/19939/9/1994, 59 FR 46562 218.583Gasoline Dispensing Operations—Storage Tank Filling Operations12/23/20133/13/2015, 80 FR 13248 218.584Gasoline Delivery Vessels9/27/19939/9/1994, 59 FR 46562 218.586Gasoline Dispensing Operations—Motor Vehicle Fueling Operations12/23/20133/13/2015, 80 FR 13248 Subpart Z: Dry Cleaners218.607Standards for Petroleum Solvent Dry Cleaners8/16/19919/9/1994, 59 FR 46562 218.608Operating Practices for Petroleum Solvent Dry Cleaners9/27/19939/9/1994, 59 FR 46562 218.609Program for Inspection and Repair of Leaks9/27/19939/9/1994, 59 FR 46562 218.610Testing and Monitoring9/27/19939/9/1994, 59 FR 46562 218.611Applicability for Petroleum Solvent Dry Cleaners1/24/199410/21/1996, 61 FR 54556 Subpart AA: Paint and Ink Manufacturing218.620Applicability1/24/199410/21/1996, 61 FR 54556 218.621Exemption for Waterbase Material and Heatset Offset Ink9/27/19939/9/1994, 59 FR 46562 218.624Open Top Mills, Tanks, Vats or Vessels9/27/19939/9/1994, 59 FR 46562 218.625Grinding Mills8/16/19919/9/1994, 59 FR 46562 218.626Storage Tanks8/16/19919/9/1994, 59 FR 46562 218.628Leaks9/27/19939/9/1994, 59 FR 46562 218.630Clean Up8/16/19919/9/1994, 59 FR 46562 218.636Compliance Schedule9/27/19939/9/1994, 59 FR 46562 218.637Recordkeeping and Reporting9/27/19939/9/1994, 59 FR 46562 Subpart BB: Polystyrene Plants218.640Applicability9/27/19939/9/1994, 59 FR 46562 218.642Emissions Limitation at Polystyrene Plants9/27/19939/9/1994, 59 FR 46562 218.644Emissions Testing9/27/19939/9/1994, 59 FR 46562 Subpart CC: Polyester Resin Product Manufacturing Process218.660Applicability1/24/199410/21/1996, 61 FR 54556 218.666Control Requirements1/24/199410/21/1996, 61 FR 54556 218.667Compliance Schedule1/24/199410/21/1996, 61 FR 54556 218.668Testing1/24/199410/21/1996, 61 FR 54556 218.670Recordkeeping and Reporting for Exempt Emission Units1/24/199410/21/1996, 61 FR 54556 218.672Recordkeeping and Reporting for Subject Emission Units1/24/199410/21/1996, 61 FR 54556 Subpart DD: Aerosol Can Fillings218.680Applicability1/24/199410/21/1996, 61 FR 54556 218.686Control Requirements5/9/19953/12/1997, 62 FR 11327 218.688Testing1/24/199410/21/1996, 61 FR 54556 218.690Recordkeeping and Reporting for Exempt Emission Units1/24/199410/21/1996, 61 FR 54556 218.692Recordkeeping and Reporting for Subject Emission Units1/24/199410/21/1996, 61 FR 54556 Subpart GG: Marine Terminals218.760Applicability10/25/19944/3/1995, 60 FR 16801 218.762Control Requirements10/25/19944/3/1995, 60 FR 16801 218.764Compliance Certification10/25/19944/3/1995, 60 FR 16801 218.766Leaks10/25/19944/3/1995, 60 FR 16801 218.768Testing and Monitoring10/25/19944/3/1995, 60 FR 16801 218.770Recordkeeping and Reporting10/25/19944/3/1995, 60 FR 16801 Subpart HH: Motor Vehicle Refinishing218.780Emission Limitations5/9/19957/25/1996, 61 FR 38577 218.782Alternative Control Requirements5/9/19957/25/1996, 61 FR 38577 218.784Equipment Specifications1/28/201310/6/2014, 79 FR 60070 218.786Surface Preparation Materials5/9/19957/25/1996, 61 FR 38577 218.787Work Practices5/9/19957/25/1996, 61 FR 38577 218.788Testing5/9/19957/25/1996, 61 FR 38577 218.789Monitoring and Recordkeeping for Control Devices5/9/19957/25/1996, 61 FR 38577 218.790General Recordkeeping and Reporting5/9/19957/25/1996, 61 FR 38577 218.791Compliance Date5/9/19957/25/1996, 61 FR 38577 Subpart II: Fiberglass Boat Manufacturing Materials218.890Applicability9/14/20103/23/2012, 77 FR 16940 218.891Emission Limitations and Control Requirements7/27/113/23/12, 77 FR 16940 218.892Testing Requirements7/27/20113/23/2012, 77 FR 16940 218.894Recordkeeping and Reporting Requirements7/27/20113/23/2012, 77 FR 16940 Subpart JJ: Miscellaneous Industrial Adhesives218.900Applicability9/14/20103/23/2012, 77 FR 16940 218.901Emission Limitations and Control Requirements7/27/20113/23/2012, 77 FR 16940 218.902Testing Requirements7/27/20113/23/2012, 77 FR 16940 218.903Monitoring Requirements7/27/20113/23/2012, 77 FR 16940 218.904Recordkeeping and Reporting Requirements7/27/20113/23/2012, 77 FR 16940 Subpart PP: Miscellaneous Fabricated Product Manufacturing Processes218.920Applicability1/24/199410/21/1996, 61 FR 54556 218.926Control Requirements1/24/199410/21/1996, 61 FR 54556 218.927Compliance Schedule9/27/199310/21/1996, 61 FR 54556 218.928Testing9/27/199310/21/1996, 61 FR 54556 218.929Cementable and Dress or Performance Shoe Leather4/8/20035/24/2004, 69 FR 29446 Subpart QQ: Miscellaneous Formulation Manufacturing Processes218.940Applicability7/16/19986/18/1999, 64 FR 32810 218.946Control Requirements1/24/199410/21/1996, 61 FR 54556 218.947Compliance Schedule9/27/19939/9/1994, 59 FR 46562 218.948Testing9/27/19939/9/1994, 59 FR 46562 Subpart RR: Miscellaneous Organic Chemical Manufacturing Processes218.960Applicability1/24/199410/21/1996, 61 FR 54556 218.966Control Requirements5/9/19953/12/1997, 62 FR 11327 218.967Compliance Schedule9/27/199310/21/1996, 61 FR 54556 218.968Testing9/27/199310/21/1996, 61 FR 54556 Subpart TT: Other Emission Units218.980Applicability5/9/19953/12/1997, 62 FR 11327 218.986Control Requirements1/24/199410/21/1996, 61 FR 54556 218.987Compliance Schedule9/27/199310/21/1996, 61 FR 54556 218.988Testing9/27/199310/21/1996, 61 FR 54556 Subpart UU: Recordkeeping and Reporting218.990Exempt Emission Units9/27/199310/21/1996, 61 FR 54556 218.991Subject Emission Units1/24/199410/21/1996, 61 FR 54556 218.Appendix A:List of Chemicals Defining Synthetic Organic Chemical and Polymer Manufacturing9/27/19939/9/1994, 59 FR 46562 218.Appendix B:VOM Measurement Techniques for Capture Efficiency9/27/19939/9/1994, 59 FR 46562 218.Appendix C:Reference Test Methods for Air Oxidation Processes9/27/19939/9/1994, 59 FR 46562 218.Appendix D:Coefficients for the Total Resource Effectiveness Index (TRE) Equation9/27/19939/9/1994, 59 FR 46562 218.Appendix E:List of Affected Marine Terminals10/25/19944/3/1995, 60 FR 16801 218.Appendix G:TRE Index Measurements for SOCMI Reactors and Distillation Units5/9/19953/23/1998, 63 FR 13784 218.Appendix H:Baseline VOM Content Limitations for Subpart F, Section 218.212 Cross-Line Averaging5/9/19952/13/1996, 61 FR 5511 Part 219: Organic Material Emission Standards and Limitations for the Metro East AreaSubpart A: General Provisions219.100Introduction9/27/19939/9/1994, 59 FR 46562 219.101Savings Clause10/25/19944/3/1995, 60 FR 16801 219.102Abbreviations and Conversion Factors9/27/19939/9/1994, 59 FR 46562 219.103Applicability8/16/19919/9/1994, 59 FR 46562 219.104Definitions9/27/19939/9/1994, 59 FR 46562 219.105Test Methods and Procedures3/4/20214/11/2023, 88 FR 21490 219.106Compliance Dates3/4/20214/11/2023, 88 FR 21490 219.107Operation of Afterburners9/27/19939/9/1994, 59 FR 46562 219.108Exemptions, Variations, and Alternative Means of Control or Compliance Determinations8/16/19919/9/1994, 59 FR 46562 219.109Vapor Pressure of Volatile Organic Liquids9/27/19939/9/1994, 59 FR 46562 219.110Vapor Pressure of Organic Material or Solvent3/4/20214/11/2023, 88 FR 21490 219.111Vapor Pressure of Volatile Organic Material9/27/19939/9/1994, 59 FR 46562 219.112Incorporation by Reference3/4/20214/11/2023, 88 FR 21490 Subpart B: Organic Emissions From Storage and Loading Operations219.119Applicability for VOL11/15/19948/8/1996, 61 FR 41338 219.120Control Requirements for Storage Containers of VOL11/15/19948/8/1996, 61 FR 41338 219.121Storage Containers of VPL9/27/19939/9/1994, 59 FR 46562 219.122Loading Operations9/27/19939/9/1994, 59 FR 46562 219.123Petroleum Liquid Storage Tanks9/27/19939/9/1994, 59 FR 46562 219.124External Floating Roofs9/27/19939/9/1994, 59 FR 46562 219.125Compliance Dates11/15/19948/8/1996, 61 FR 41338 219.127Testing VOL Operations11/15/19948/8/1996, 61 FR 41338 219.128Monitoring VOL Operations1/28/201310/6/2014, 79 FR 60070 219.129Recordkeeping and Reporting for VOL Operations11/15/19948/8/1996, 61 FR 41338 Subpart C: Organic Emissions From Miscellaneous Equipment219.141Separation Operations9/27/19939/9/1994, 59 FR 46562 219.142Pumps and Compressors8/16/19919/9/1994, 59 FR 46562 219.143Vapor Blowdown9/27/19939/9/1994, 59 FR 46562 219.144Safety Relief Valves9/27/19939/9/1994, 59 FR 46562 Subpart E: Solvent Cleaning219.181Solvent Cleaning Degreasing Operations6/25/20103/23/2012, 77 FR 16940 219.182Cold Cleaning6/9/199711/26/1997, 62 FR 62951 219.183Open Top Vapor Degreasing9/27/19939/9/1994, 59 FR 46562 219.184Conveyorized Degreasing9/27/19939/9/1994, 59 FR 46562 219.186Test Methods9/27/19939/9/1994, 59 FR 46562 219.187Other Industrial Cleaning Operations3/4/20214/11/2023, 88 FR 21490 Subpart F: Coating Operations219.204Emission Limitations3/4/20214/11/2023, 88 FR 21490 219.205Daily-Weighted Average Limitations3/4/20214/11/2023, 88 FR 21490 219.206Solids Basis Calculation9/27/19939/9/1994, 59 FR 46562 219.207Alternative Emission Limitations3/4/20214/11/2023, 88 FR 21490 219.208Exemptions from Emission Limitations3/4/20214/11/2023, 88 FR 21490 219.209Exemption From General Rule on Use of Organic Material9/27/19939/9/1994, 59 FR 46562 219.210Compliance Schedule9/14/20103/23/2012, 77 FR 16940 219.211Recordkeeping and Reporting3/4/20214/11/2023, 88 FR 21490 219.212Cross-Line Averaging To Establish Compliance for Coating Lines9/14/20103/23/2012, 77 FR 16940 219.213Recordkeeping and Reporting for Cross-Line Averaging Participating Coating Lines5/9/19952/13/1996, 61 FR 5511 219.214Changing Compliance Methods5/9/19952/13/1996, 61 FR 5511 219.215Wood Furniture Coating Averaging Approach2/2/19985/19/1998, 63 FR 27489 219.216Wood Furniture Coating Add-On Control Use2/2/19985/19/1998, 63 FR 27489 219.217Wood Furniture Coating and Flat Wood Paneling Coating Work Practice Standards7/27/20113/23/2012, 77 FR 16940 219.218Work Practice Standards for Paper Coatings, Metal Furniture Coatings, and Large Appliance Coatings3/23/20103/23/2012, 77 FR 16940 219.219Work Practice Standards for Aerospace Facilities3/4/20214/11/2023, 88 FR 21490 Subpart G: Use of Organic Material219.301Use of Organic Material9/27/19939/9/1994, 59 FR 46562 219.302Alternative Standard9/27/19939/9/1994, 59 FR 46562 219.303Fuel Combustion Emission Units9/27/19939/9/1994, 59 FR 46562 219.304Operations With Compliance Program9/27/19939/9/1994, 59 FR 46562 Subpart H: Printing and Publishing219.401Flexographic and Rotogravure Printing7/27/20113/23/2012, 77 FR 16940 219.402Applicability6/25/20103/23/2012, 77 FR 16940 219.403Compliance Schedule6/25/20103/23/2012, 77 FR 16940 219.404Recordkeeping and Reporting7/27/20113/23/2012, 77 FR 16940 219.405Lithographic Printing: Applicability6/25/20103/23/2012, 77 FR 16940 219.407Emission Limitations and Control Requirements for Lithographic Printing Lines6/25/20103/23/2012, 77 FR 16940 219.409Testing for Lithographic Printing7/27/20113/23/2012, 77 FR 16940 219.410Monitoring Requirements for Lithographic Printing6/25/20103/23/2012, 77 FR 16940 219.411Recordkeeping and Reporting for Lithographic Printing7/27/20113/23/2012, 77 FR 16940 219.412Letterpress Printing Lines: Applicability6/25/20103/23/2012, 77 FR 16940 219.413Emission Limitations and Control Requirements for Letterpress Printing Lines6/25/20103/23/2012, 77 FR 16940 219.415Testing for Letterpress Printing Lines7/27/20113/23/2012, 77 FR 16940 219.416Monitoring Requirements for Letterpress Printing Lines6/25/20103/23/2012, 77 FR 16940 219.417Recordkeeping and Reporting for Letterpress Printing Lines7/27/20113/23/2012, 77 FR 16940 Subpart Q: Synthetic Organic Chemical and Polymer Manufacturing Plant219.421General Requirements9/27/19939/9/1994, 59 FR 46562 219.422Inspection Program Plan for Leaks9/27/19939/9/1994, 59 FR 46562 219.423Inspection Program for Leaks9/27/19939/9/1994, 59 FR 46562 219.424Repairing Leaks9/27/19939/9/1994, 59 FR 46562 219.425Recordkeeping for Leaks9/27/19939/9/1994, 59 FR 46562 219.426Report for Leaks9/27/19939/9/1994, 59 FR 46562 219.427Alternative Program for Leaks9/27/19939/9/1994, 59 FR 46562 219.428Open-Ended Valves9/27/19939/9/1994, 59 FR 46562 219.429Standards for Control Devices9/27/19939/9/1994, 59 FR 46562 219.431Applicability5/9/19953/23/1998, 63 FR 13784 219.432Control Requirements5/9/19953/23/1998, 63 FR 13784 219.433Performance and Testing Requirements5/9/19953/23/1998, 63 FR 13784 219.434Monitoring Requirements5/9/19953/23/1998, 63 FR 13784 219.435Recordkeeping and Reporting Requirements5/9/19953/23/1998, 63 FR 13784 219.436Compliance Date5/9/19953/23/1998, 63 FR 13784 Subpart R: Petroleum Refining and Related Industries; Asphalt Materials219.441Petroleum Refinery Waste Gas Disposal9/27/19939/9/1994, 59 FR 46562 219.442Vacuum Producing Systems8/16/19919/9/1994, 59 FR 46562 219.443Wastewater (Oil/Water) Separator9/27/19939/9/1994, 59 FR 46562 219.444Process Unit Turnarounds8/16/19919/9/1994, 59 FR 46562 219.445Leaks: General Requirements9/27/19939/9/1994, 59 FR 46562 219.446Monitoring Program Plan for Leaks9/27/19939/9/1994, 59 FR 46562 219.447Monitoring Program for Leaks9/27/19939/9/1994, 59 FR 46562 219.448Recordkeeping for Leaks8/16/19919/9/1994, 59 FR 46562 219.449Reporting for Leaks9/27/19939/9/1994, 59 FR 46562 219.450Alternative Program for Leaks9/27/19939/9/1994, 59 FR 46562 219.451Sealing Device Requirements8/16/19919/9/1994, 59 FR 46562 219.452Compliance Schedule for Leaks9/27/19939/9/1994, 59 FR 46562 Subpart S: Rubber and Miscellaneous Plastic Products219.461Manufacture of Pneumatic Rubber Tires9/27/19939/9/1994, 59 FR 46562 219.462Green Tire Spraying Operations9/27/19939/9/1994, 59 FR 46562 219.463Alternative Emission Reduction Systems9/27/19939/9/1994, 59 FR 46562 219.464Emission Testing9/27/19939/9/1994, 59 FR 46562 Subpart T: Pharmaceutical Manufacturing219.480Applicability5/9/19953/12/1997, 62 FR 11327 219.481Control of Reactors, Distillation Units, Crystallizers, Centrifuges and Vacuum Dryers9/27/19939/9/1994, 59 FR 46562 219.482Control of Air Dryers, Production Equipment Exhaust Systems and Filters9/27/19939/9/1994, 59 FR 46562 219.483Material Storage and Transfer9/27/19939/9/1994, 59 FR 46562 219.484In-Process Tanks8/16/19919/9/1994, 59 FR 46562 219.485Leaks9/27/19939/9/1994, 59 FR 46562 219.486Other Emission Units9/27/19939/9/1994, 59 FR 46562 219.487Testing9/27/19939/9/1994, 59 FR 46562 219.488Monitoring for Air Pollution Control Equipment8/16/19919/9/1994, 59 FR 46562 219.489Recordkeeping for Air Pollution Control Equipment9/27/19939/9/1994, 59 FR 46562 Subpart V: Batch Operations and Air Oxidation Processes219.500Applicability for Batch Operations5/22/19954/2/1996, 61 FR 14484 219.501Control Requirements for Batch Operations5/22/19954/2/1996, 61 FR 14484 219.502Determination of Uncontrolled Total Annual Mass Emissions and Actual Weighted Average Flow Rate Values for Batch Operations5/22/19954/2/1996, 61 FR 14484 219.503Performance and Testing Requirements for Batch Operations5/22/19954/2/1996, 61 FR 14484 219.504Monitoring Requirements for Batch Operations5/22/19954/2/1996, 61 FR 14484 219.505Reporting and Recordkeeping for Batch Operations5/22/19954/2/1996, 61 FR 14484 219.506Compliance Date5/22/19954/2/1996, 61 FR 14484 219.520Emission Limitations for Air Oxidation Processes11/15/19949/27/1995, 60 FR 49770 219.522Savings Clause11/15/19949/27/1995, 60 FR 49770 219.523Compliance11/15/19949/27/1995, 60 FR 49770 219.524Determination of Applicability11/15/19949/27/1995, 60 FR 49770 219.526Testing and Monitoring8/16/19919/9/1994, 59 FR 46562 Subpart W: Agriculture219.541Pesticide Exception9/27/19939/9/1994, 59 FR 46562 Subpart X: Construction219.561Architectural Coatings8/16/19919/9/1994, 59 FR 46562 219.562Paving Operations9/27/19939/9/1994, 59 FR 46562 219.563Cutback Asphalt8/16/19919/9/1994, 59 FR 46562 Subpart Y: Gasoline Distribution219.581Bulk Gasoline Plants9/27/19939/9/1994, 59 FR 46562 219.582Bulk Gasoline Terminals9/27/19939/9/1994, 59 FR 46562 219.583Gasoline Dispensing Operations—Storage Tank Filling Operations12/23/20133/13/2015, 80 FR 13248 219.584Gasoline Delivery Vessels9/27/19939/9/1994, 59 FR 46562 Subpart Z: Dry Cleaners219.607Standards for Petroleum Solvent Dry Cleaners8/16/19919/9/1994, 59 FR 46562 219.608Operating Practices for Petroleum Solvent Dry Cleaners9/27/19939/9/1994, 59 FR 46562 219.609Program for Inspection and Repair of Leaks9/27/19939/9/1994, 59 FR 46562 219.610Testing and Monitoring9/27/19939/9/1994, 59 FR 46562 219.611Exemption for Petroleum Solvent Dry Cleaners9/27/19939/9/1994, 59 FR 46562 Subpart AA: Paint and Ink Manufacturing219.620Applicability9/27/19939/9/1994, 59 FR 46562 219.621Exemption for Waterbase Material and Heatset-Offset Ink9/27/19939/9/1994, 59 FR 46562 219.623Permit Conditions9/27/19939/9/1994, 59 FR 46562 219.624Open-Top Mills, Tanks, Vats or Vessels9/27/19939/9/1994, 59 FR 46562 219.625Grinding Mills8/16/19919/9/1994, 59 FR 46562 219.626Storage Tanks8/16/19919/9/1994, 59 FR 46562 219.628Leaks9/27/19939/9/1994, 59 FR 46562 219.630Clean Up8/16/19919/9/1994, 59 FR 46562 219.636Compliance Schedule9/27/19939/9/1994, 59 FR 46562 219.637Recordkeeping and Reporting9/27/19939/9/1994, 59 FR 46562 Subpart BB: Polystyrene Plants219.640Applicability9/27/19939/9/1994, 59 FR 46562 219.642Emissions Limitation at Polystyrene Plants9/27/19939/9/1994, 59 FR 46562 219.644Emissions Testing9/27/19939/9/1994, 59 FR 46562 Subpart GG: Marine Terminals219.760Applicability10/25/19944/3/1995, 60 FR 16801 219.762Control Requirements10/25/19944/3/1995, 60 FR 16801 219.764Compliance Certification10/25/19944/3/1995, 60 FR 16801 219.766Leaks10/25/19944/3/1995, 60 FR 16801 219.768Testing and Monitoring10/25/19944/3/1995, 60 FR 16801 219.770Recordkeeping and Reporting10/25/19944/3/1995, 60 FR 16801 Subpart HH: Motor Vehicle Refinishing219.780Emission Limitations5/9/19957/25/1996, 61 FR 38577 219.782Alternative Control Requirements5/9/19957/25/1996, 61 FR 38577 219.784Equipment Specifications1/28/201310/6/2014, 79 FR 60070 219.786Surface Preparation Materials5/9/19957/25/1996, 61 FR 38577 219.787Work Practices5/9/19957/25/1996, 61 FR 38577 219.788Testing5/9/19957/25/1996, 61 FR 38577 219.789Monitoring and Recordkeeping for Control Devices5/9/19957/25/1996, 61 FR 38577 219.791Compliance Date5/9/19957/25/1996, 61 FR 38577 Subpart II: Fiberglass Boat Manufacturing Materials219.890Applicability9/14/20103/23/2012, 77 FR 16940 219.891Emission Limitations and Control Requirements7/27/20113/23/2012, 77 FR 16940 219.892Testing and Monitoring Requirements7/27/20113/23/2012, 77 FR 16940 219.894Recordkeeping and Reporting Requirements7/27/20113/23/2012, 77 FR 16940 Subpart JJ: Miscellaneous Industrial Adhesives219.900Applicability9/14/20103/23/2012, 77 FR 16940 219.901Emission Limitations and Control Requirements7/27/20113/23/2012, 77 FR 16940 219.902Testing Requirements7/27/20113/23/2012, 77 FR 16940 219.903Monitoring Requirements7/27/20113/23/2012, 77 FR 16940 219.904Recordkeeping and Reporting Requirements7/27/20113/23/2012, 77 FR 16940 Subpart PP: Miscellaneous Fabricated Product Manufacturing Processes219.920Applicability9/27/19935/7/1996, 61 FR 20455 219.923Permit Conditions9/27/19935/7/1996, 61 FR 20455 219.926Control Requirements5/9/19955/7/1996, 61 FR 20455 219.927Compliance Schedule9/27/19935/7/1996, 61 FR 20455 219.928Testing9/27/19935/7/1996, 61 FR 20455 Subpart QQ: Miscellaneous Formulation Manufacturing Processes219.940Applicability9/27/19935/7/1996, 61 FR 20455 219.943Permit Conditions9/27/19935/7/1996, 61 FR 20455 219.946Control Requirements5/9/19955/7/1996, 61 FR 20455 219.947Compliance Schedule9/27/19935/7/1996, 61 FR 20455 219.948Testing9/27/19935/7/1996, 61 FR 20455 Subpart RR: Miscellaneous Organic Chemical Manufacturing Processes219.960Applicability9/27/19935/7/1996, 61 FR 20455 219.963Permit Conditions9/27/19935/7/1996, 61 FR 20455 219.966Control Requirements5/9/19955/7/1996, 61 FR 20455 219.967Compliance Schedule9/27/19935/7/1996, 61 FR 20455 219.968Testing9/27/19935/7/1996, 61 FR 20455 Subpart TT: Other Emission Units219.980Applicability5/9/19953/12/1997, 62 FR 11327 219.983Permit Conditions9/27/19935/7/1996, 61 FR 20455 219.986Control Requirements5/9/19955/7/1996, 61 FR 20455 219.987Compliance Schedule9/27/19935/7/1996, 61 FR 20455 219.988Testing9/27/19935/7/1996, 61 FR 20455 Subpart UU: Recordkeeping and Reporting219.990Exempt Emission Units9/27/19935/7/1996, 61 FR 20455 219.991Subject Emission Units9/27/19935/7/1996, 61 FR 20455 219.Appendix A:List of Chemicals Defining Synthetic Organic Chemical and Polymer Manufacturing9/27/19939/9/1994, 59 FR 46562 219.Appendix B:VOM Measurement Techniques for Capture Efficiency (Repealed)9/27/19939/9/1994, 59 FR 46562 219.Appendix C:Reference Methods and Procedures9/27/19939/9/1994, 59 FR 46562 219.Appendix D:Coefficients for the Total Resource Effectiveness Index (TRE) Equation9/27/19939/9/1994, 59 FR 46562 219.Appendix E:List of Affected Marine Terminals2/15/19964/3/1995, 60 FR 16801 219.Appendix G:TRE Index Measurements for SOCMI Reactors and Distillation Units5/9/19953/23/1998, 63 FR 13784 219.Appendix H:Baseline VOM Content Limitations for Subpart F, Section 219.212 Cross-Line Averaging5/9/19952/13/1996, 61 FR 5511 Part 223: Standards and Limitations for Organic Material Emissions for Area SourcesSubpart A: General Provisions223.100Severability6/8/20095/6/2013, 78 FR 26258 223.105Abbreviations and Acronyms6/8/20095/6/2013, 78 FR 26258 223.120Incorporations by Reference6/8/20095/6/2013, 78 FR 26258 Subpart B: Consumer and Commercial Products223.200Purpose6/8/20095/6/2013, 78 FR 26258 223.201Applicability5/4/20125/6/2013, 78 FR 26258 223.203Definitions for Subpart B5/4/20125/6/2013, 78 FR 26258 223.205Standards5/4/20125/6/2013, 78 FR 26258 223.206Diluted Products6/8/20095/6/2013, 78 FR 26258 223.207Products Registered Under FIFRA5/4/20125/6/2013, 78 FR 26258 223.208Requirements for Aerosol Adhesives5/4/20125/6/2013, 78 FR 26258 223.209Requirements for Floor Wax Strippers6/8/20095/6/2013, 78 FR 26258 223.210Products Containing Ozone-Depleting Compounds6/8/20095/6/2013, 78 FR 26258 223.211Requirements for Adhesive Removers, Aerosol Adhesives, Contact Adhesives, Electrical Cleaners, Electronic Cleaners, Footwear or Leather Care Products, General Purpose Degreasers, and Graffiti Removers5/4/20125/6/2013, 78 FR 26258 223.220Requirements for Charcoal Lighter Material6/8/20095/6/2013, 78 FR 26258 223.230Exemptions6/8/20095/6/2013, 78 FR 26258 223.240Innovative Product Exemption6/8/20095/6/2013, 78 FR 26258 223.245Alternative Compliance Plans6/8/20095/6/2013, 78 FR 26258 223.250Product Dating6/8/20095/6/2013, 78 FR 26258 223.255Additional Product Dating Requirements6/8/20095/6/2013, 78 FR 26258 223.260Most Restrictive Limit6/8/20095/6/2013, 78 FR 26258 223.265Additional Labeling Requirements for Aerosol Adhesives, Adhesive Removers, Electronic Cleaners, Electrical Cleaners, Energized Electrical Cleaners, and Contact Adhesives6/8/20095/6/2013, 78 FR 26258 223.270Reporting Requirements6/8/20095/6/2013, 78 FR 26258 223.275Special Recordkeeping Requirements for Consumer Products That Contain Perchloroethylene or Methylene Chloride6/8/20095/6/2013, 78 FR 26258 223.280Calculating Illinois Sales6/8/20095/6/13, 78 FR 26258 223.285Test Methods6/8/20095/6/2013, 78 FR 26258 Subpart C: Architectural and Industrial Maintenance Coatings223.300Purpose6/8/20095/6/2013, 78 FR 26258 223.305Applicability5/4/20125/6/2013, 78 FR 26258 223.307Definitions for Subpart C6/8/20095/6/2013, 78 FR 26258 223.310Standards6/8/20095/6/2013, 78 FR 26258 223.320Container Labeling Requirements6/8/20095/6/2013, 78 FR 26258 223.330Reporting Requirements6/8/20095/6/2013, 78 FR 26258 223.340Compliance Provisions and Test Methods6/8/20095/6/2013, 78 FR 26258 223.350Alternative Test Methods6/8/20095/6/2013, 78 FR 26258 223.360Methacrylate Traffic Coating Markings6/8/20095/6/2013, 78 FR 26258 223.370Test Methods6/8/20095/6/2013, 78 FR 26258 Part 225: Control of Emissions From Large Combustion SourcesSubpart A: General Provisions225.120Abbreviations and Acronyms8/31/200710/16/2007, 72 FR 58528 225.130Definitions8/31/200710/16/2007, 72 FR 58528 225.140Incorporations by Reference8/31/200710/16/2007, 72 FR 58528 225.150Commence Commercial Operation8/31/200710/16/2007, 72 FR 58528 Subpart B: Control of Mercury Emissions From Coal-Fired Electric Generating Units225.233Multi-Pollutant Standard (MPS)8/23/20196/25/2021, 86 FR 33527Except (c), (d), and (i). 225.291Combined Pollutant Standard: Purpose12/7/20152/28/2018, 83 FR 8612 225.292Applicability of the Combined Pollutant Standard12/7/20152/28/2018, 83 FR 8612 225.293Combined Pollutant Standard: Notice of Intent12/7/20152/28/2018, 83 FR 8612 225.295Combined Pollutant Standard: Emission Standards for NOX and SO212/7/20152/28/2018, 83 FR 8612 Except (a)(4). 225.296Combined Pollutant Standard: Control Technology Requirements for NOX, SO2, and PM Emissions12/7/20152/28/2018, 83 FR 8612 Except (d). Subpart C: Clean Air Act Interstate Rule (CAIR) SO2 Trading Program225.300Purpose8/31/200710/16/2007, 72 FR 58528 225.305Applicability8/31/200710/16/2007, 72 FR 58528 225.310Compliance Requirements8/31/200710/16/2007, 72 FR 58528 225.315Appeal Procedures8/31/200710/16/2007, 72 FR 58528 225.320Permit Requirements8/31/200710/16/2007, 72 FR 58528 225.325Trading Program8/31/200710/16/2007, 72 FR 58528 Subpart D: CAIR NOX Annual Trading Program225.400Purpose8/31/200710/16/2007, 72 FR 58528 225.405Applicability8/31/200710/16/2007, 72 FR 58528 225.410Compliance Requirements8/31/200710/16/2007, 72 FR 58528 225.415Appeal Procedures8/31/200710/16/2007, 72 FR 58528 225.420Permit Requirements8/31/200710/16/2007, 72 FR 58528 225.425Annual Trading Budget8/31/200710/16/2007, 72 FR 58528 225.430Timing for Annual Allocations8/31/200710/16/2007, 72 FR 58528 225.435Methodology for Calculating Annual Allocations8/31/200710/16/2007, 72 FR 58528 225.440Annual Allocations8/31/200710/16/2007, 72 FR 58528 225.445New Unit Set-Aside (NUSA)8/31/200710/16/2007, 72 FR 58528 225.450Monitoring, Recordkeeping and Reporting Requirements for Gross Electrical Output and Useful Thermal Energy8/31/200710/16/2007, 72 FR 58528 225.455Clean Air Set-Aside (CASA)8/31/200710/16/2007, 72 FR 58528 225.460Energy Efficiency and Conservation, Renewable Energy, and Clean Technology Projects8/31/200710/16/2007, 72 FR 58528 225.465Clean Air Set-Aside (CASA) Allowances8/31/200710/16/2007, 72 FR 58528 225.470Clean Air Set-Aside (CASA) Applications8/31/200710/16/2007, 72 FR 58528 225.475Agency Action on Clean Air Set-Aside (CASA) Applications8/31/200710/16/2007, 72 FR 58528 225.480Compliance Supplement Pool8/31/200710/16/2007, 72 FR 58528 Subpart E: CAIR NOX Ozone Season Trading Program225.500Purpose8/31/200710/16/2007, 72 FR 58528 225.505Applicability8/31/200710/16/2007, 72 FR 58528 225.510Compliance Requirements8/31/200710/16/2007, 72 FR 58528 225.515Appeal Procedures8/31/200710/16/2007, 72 FR 58528 225.520Permit Requirements8/31/200710/16/2007, 72 FR 58528 225.525Ozone Season Trading Budget8/31/200710/16/2007, 72 FR 58528 225.530Timing for Ozone Season Allocations8/31/200710/16/2007, 72 FR 58528 225.535Methodology for Calculating Ozone Season Allocations8/31/200710/16/2007, 72 FR 58528 225.540Ozone Season Allocations8/31/200710/16/2007, 72 FR 58528 225.545New Unit Set-Aside (NUSA)8/31/200710/16/2007, 72 FR 58528 225.550Monitoring, Recordkeeping and Reporting Requirements for Gross Electrical Output and Useful Thermal Energy8/31/200710/16/2007, 72 FR 58528 225.555Clean Air Set-Aside (CASA)8/31/200710/16/2007, 72 FR 58528 225.560Energy Efficiency and Conservation, Renewable Energy, and Clean Technology Projects8/31/200710/16/2007, 72 FR 58528 225.565Clean Air Set-Aside (CASA) Allowances8/31/200710/16/2007, 72 FR 58528 225.570Clean Air Set-Aside (CASA) Applications8/31/200710/16/2007, 72 FR 58528 225.575Agency Action on Clean Air Set-Aside (CASA) Applications8/31/200710/16/2007, 72 FR 58528 225.Appendix ASpecified EGUs for Purposes of the CPS Coal-Fired Boilers as of July 1, 201612/7/20152/28/2018, 83 FR 8612 Part 226: Standards and Limitations for Certain Sources of Lead226.100Severability4/21/20143/28/2018, 83 FR 13198 226.105Scope and Organization4/21/20143/28/2018, 83 FR 13198 226.110Abbreviations and Acronyms4/21/20143/28/2018, 83 FR 13198 226.115Definitions4/21/20143/28/2018, 83 FR 13198 226.120Incorporations by Reference4/21/20143/28/2018, 83 FR 13198 226.125Applicability4/21/20143/28/2018, 83 FR 13198 226.130Compliance Date4/21/20143/28/2018, 83 FR 13198 226.140Lead Emission Standards4/21/20143/28/2018, 83 FR 13198 226.150Operational Monitoring for Control Device4/21/20143/28/2018, 83 FR 13198 226.155Total Enclosure4/21/20143/28/2018, 83 FR 13198 226.160Operational Measurement for Total Enclosure4/21/20143/28/2018, 83 FR 13198 226.165Inspection4/21/20143/28/2018, 83 FR 13198 226.170Lead Fugitive Dust Operating Program4/21/20143/28/2018, 83 FR 13198 226.175Emissions Testing4/21/20143/28/2018, 83 FR 13198 226.185Recordkeeping and Reporting4/21/20143/28/2018, 83 FR 13198 Subchapter i: Open BurningPart 237: Open BurningSubpart A: General Provisions237.101Definitions9/7/19715/31/1972, 37 FR 10862Approved as Rule 401. 237.102Prohibitions9/7/19715/31/1972, 37 FR 10862Approved as Rule 402. 237.103Explosive Wastes9/7/19715/31/1972, 37 FR 10862Approved as Rule 405. 237.110Local Enforcement9/7/19715/31/1972, 37 FR 10862Approved as Rule 406. 237.120Exemptions9/7/19715/31/1972, 37 FR 10862Approved as Rule 403. Subpart B: Permits237.201Permits9/7/19715/31/1972, 37 FR 10862Approved as Rule 404. Subchapter k: Emission Standards and Limitations for Mobile SourcesPart 240: Mobile SourcesSubpart A: Definitions and General Provisions240.101Preamble12/20/19948/13/2014, 79 FR 47377 240.102Definitions2/1/20128/13/2014, 79 FR 47377 240.103Prohibitions4/14/19728/13/2014, 79 FR 47377 240.104Inspection2/1/20128/13/2014, 79 FR 47377 240.105Penalties2/1/20128/13/2014, 79 FR 47377 240.106Determination of Violation2/1/20128/13/2014, 79 FR 47377 240.107Incorporations by Reference3/18/20118/13/2014, 79 FR 47377 Subpart B: Emissions240.121Smoke Emissions2/1/20128/13/2014, 79 FR 47377 240.122Diesel Engine Emissions Standards for Locomotives4/7/19928/13/2014, 79 FR 47377 240.123Liquid Petroleum Gas Fuel Systems2/1/20128/13/2014, 79 FR 47377 Subpart C: Smoke Opacity Standards and Test Procedures for Diesel-Powered Heavy Duty Vehicles240.140Applicability2/26/20018/13/2014, 79 FR 47377 240.141Smoke Opacity Standards and Test Procedures for Diesel-Powered Heavy Duty Vehicles2/26/20018/13/2014, 79 FR 47377 Subpart D: Steady-State Idle Mode Test Emission Standards240.151Applicability2/1/20128/13/2014, 79 FR 47377 240.152Steady-State Idle Mode Vehicle Exhaust Emission Standards3/18/20118/13/2014, 79 FR 47377 240.153Compliance Determination3/18/20118/13/2014, 79 FR 47377 Subpart F: Evaporative Test Standards240.171Applicability2/1/20128/13/2014, 79 FR 47377 240.172Evaporative System Integrity Test Standards7/13/19988/13/2014, 79 FR 47377 Subpart G: On-Road Remote Sensing Test Emission Standards240.181Applicability3/18/20118/13/2014, 79 FR 47377 240.182On-Road Remote Sensing Emission Standards3/18/20118/13/2014, 79 FR 47377 240.183Compliance Determination7/13/19988/13/2014, 79 FR 47377 Subpart H: On-Board Diagnostic Test Standards240.191Applicability3/18/20118/13/2014, 79 FR 47377 240.192On-Board Diagnostic Test Standards12/18/20018/13/2014, 79 FR 47377 240.193Compliance Determination12/18/20018/13/2014, 79 FR 47377 Subpart I: Visual Inspection Test Standards240.201Applicability2/1/20128/13/2014, 79 FR 47377 240.202Visual Inspection Test Standards2/1/20128/13/2014, 79 FR 47377 240.203Compliance Determination2/1/20128/13/2014, 79 FR 47377 240.Appendix A:Rule Into Section Table2/1/20128/13/2014, 79 FR 47377 240.Appendix B:Section Into Rule Table2/1/20128/13/2014, 79 FR 47377 Part 241: Clean Fuel Fleet ProgramSubpart A: General Provisions241.101Other Definitions9/11/19953/19/1996, 61 FR 11139 241.102Definitions9/11/19953/19/1996, 61 FR 11139 241.103Abbreviations9/11/19953/19/1996, 61 FR 11139 241.104Incorporations by Reference9/11/19953/19/1996, 61 FR 11139 Subpart B: General Requirements241.110Applicability9/11/19953/19/1996, 61 FR 11139 241.111Exemptions9/11/19953/19/1996, 61 FR 11139 241.112Registration of Fleet Owners or Operators9/11/19953/19/1996, 61 FR 11139 241.113Control Requirements11/25/19972/17/1999, 64 FR 7788 241.114Conversions9/11/19953/19/1996, 61 FR 11139 241.115Operating Requirements9/11/19953/19/1996, 61 FR 11139 Subpart C: Credits241.130Clean Fuel Fleet Credit Program11/25/19972/17/1999, 64 FR 7788 241.131Credit Provisions9/11/19953/19/1996, 61 FR 11139 Subpart D: Recordkeeping and Reporting241.140Reporting Requirements11/25/19972/17/1999, 64 FR 7788 241.141Recordkeeping Requirements9/11/19953/19/1996, 61 FR 11139 241.142Report of Credit Activities9/11/19953/19/1996, 61 FR 11139 241.Appendix A:Emission Standards for Clean Fuel Vehicles9/11/19953/19/1996, 61 FR 11139 241.Appendix B:Credit Values11/25/19972/17/1999, 64 FR 7788 Subchapter l: Air Quality Standards and EpisodesPart 243: Air Quality StandardsSubpart A: General Provisions243.101Definitions12/17/202010/4/2021, 86 FR 54626 243.102Scope12/17/202010/4/2021, 86 FR 54626 243.103Applicability7/29/20135/20/2015, 80 FR 28835 243.104Nondegradation10/25/20115/23/2013, 78 FR 30770 243.105Air Quality Monitoring Data Influenced by Exceptional Events12/17/202010/4/2021, 86 FR 54626 243.106Monitoring4/14/19722/21/1980, 45 FR 11472 243.107Reference Conditions12/17/202010/4/2021, 86 FR 54626 243.108Incorporation by Reference3/4/20221/17/2024, 89 FR 2883 Subpart B: Standards and Measurement Methods243.120PM10 and PM2.58/18/202010/4/2021, 86 FR 54626 243.122Sulfur Oxides (Sulfur Dioxide)3/4/20221/17/2024, 89 FR 2883 243.123Carbon Monoxide8/18/202010/4/2021, 86 FR 54626 243.124Nitrogen Oxides (Nitrogen Dioxide as Indicator)8/18/202010/4/2021, 86 FR 54626 243.126Lead8/18/202010/4/2021, 86 FR 54626 243.120PM10 and PM2.52/19/201911/5/2019, 84 FR 59527 243.123Carbon Monoxide7/29/20135/20/2015, 80 FR 28835 243.124Nitrogen Oxides (Nitrogen Dioxide as Indicator)1/23/20177/18/2017, 82 FR 32771 243.125Ozone2/19/201911/5/2019, 84 FR 59527 243.126Lead2/19/201911/5/2019, 84 FR 59527 Part 244: EpisodesSubpart A: Definitions and General Provisions244.101Definitions5/15/19921/12/1993, 58 FR 3844 244.102Responsibility of the Agency8/18/19722/21/1980, 45 FR 11472Approved as Rule 402. 244.103Determination of Required Actions8/18/19722/21/1980, 45 FR 11472Approved as Rule 402. 244.104Determination of Atmospheric Conditions8/18/19722/21/1980, 45 FR 11472Approved as Rule 402. 244.105Determination of Expected Contaminant Emissions8/18/19722/21/1980, 45 FR 11472Approved as Rule 402. 244.106Monitoring5/15/19921/12/1993, 58 FR 3844 244.107Determination of Areas Affected5/15/19921/12/1993, 58 FR 3844 244.108Failure To Comply With Episode Requirements8/18/19722/21/1980, 45 FR 11472Approved as Rule 402. 244.109Sealing of Offenders8/18/19722/21/1980, 45 FR 11472Approved as Rule 402. Subpart B: Local Agency Responsibilities244.121Local Agency Responsibilities5/15/19921/12/1993, 58 FR 3844 Subpart C: Episode Action Plans244.141Requirement for Plans8/18/19722/21/1980, 45 FR 11472Approved as Rule 404. 244.142Facilities for Which Action Plans Are Required8/18/19722/21/1980, 45 FR 11472Approved as Rule 404. 244.143Submission of Plans8/18/19722/21/1980, 45 FR 11472Approved as Rule 404. 244.144Contents of Plans8/18/19722/21/1980, 45 FR 11472Approved as Rule 404. 244.145Processing Procedures8/18/19722/21/1980, 45 FR 11472Approved as Rule 404. Subpart D: Episode Stages244.161Advisory, Alert and Emergency Levels5/15/19921/12/1993, 58 FR 3844 244.162Criteria for Declaring an Advisory5/15/19921/12/1993, 58 FR 3844 244.163Criteria for Declaring a Yellow Alert5/15/19921/12/1993, 58 FR 3844 244.164Criteria for Declaring a Red Alert8/18/19722/21/1980, 45 FR 11472Approved as Rule 405(e). 244.165Criteria for Declaring an Emergency8/18/19722/21/1980, 45 FR 11472Approved as Rule 405(e). 244.166Criteria for Terminating Advisory, Alert and Emergency5/15/19921/12/1993, 58 FR 3844 244.167Episode Stage Notification5/15/19921/12/1993, 58 FR 3844 244.168Contents of Episode Stage Notification5/15/19921/12/1993, 58 FR 3844 244.169Actions During Episode Stages5/15/19921/12/1993, 58 FR 3844 244.Appendix D:Required Emission Reduction Actions5/15/19921/12/1993, 58 FR 3844 Chapter II: Environmental Protection AgencyPart 252: Public Participation in the Air Pollution Control Permit ProgramSubpart A: Introduction252.101Purpose6/10/20209/9/2021, 86 FR 50459 252.102Abbreviations and Acronyms6/10/20209/9/2021, 86 FR 50459 252.103Definitions6/10/20209/9/2021, 86 FR 50459 252.104Applicability6/10/20209/9/2021, 86 FR 50459 252.105Application for a PSD Permit6/10/20209/9/2021, 86 FR 50459 252.106Consolidation6/10/20209/9/2021, 86 FR 50459 Subpart B: Procedures for Public Review252.201Notice and Opportunity to Comment6/10/20209/9/2021, 86 FR 50459 252.202Draft Permit6/10/20209/9/2021, 86 FR 50459 252.203Project Summary, Statement of Basis, or Fact Sheet6/10/20209/9/2021, 86 FR 50459 252.204Availability of Documents6/10/20209/9/2021, 86 FR 50459 252.205Opportunity for Public Hearing6/10/20209/9/2021, 86 FR 50459 252.206Procedures for Public Hearings6/10/20209/9/2021, 86 FR 50459 252.207Obligation to Raise Issues and Provide Information During the Public Comment Period for PSD Permits6/10/20209/9/2021, 86 FR 50459 252.208Reopening of the Public Comment Period for PSD Permits6/10/20209/9/2021, 86 FR 50459 252.209Issuance of a Final PSD Permit Decision6/10/20209/9/2021, 86 FR 50459 252.210Response to Comments for a Final PSD Permit Decision6/10/20209/9/2021, 86 FR 50459 252.211Administrative Record for a Final PSD Permit Decision6/10/20209/9/2021, 86 FR 50459 Part 254: Annual Emissions ReportSubpart A: General Provisions254.101Purpose7/17/20015/15/2002, 67 FR 34614 254.102Applicability4/20/20127/3/2013, 67 FR 40013 254.103Definitions7/17/20015/15/2002, 67 FR 34614 254.120Applicable Pollutants for Annual Emissions Reporting7/17/20015/15/2002, 67 FR 34614 254.132Failure To File a Complete Report7/17/20015/15/2002, 67 FR 34614 254.133Voluntary Submittal of Data5/14/19935/15/2002, 67 FR 34614 254.134Retention of Records7/17/20015/15/2002, 67 FR 34614 254.135Reporting of Errors7/17/20015/15/2002, 67 FR 34614 254.136Confidentiality and Trade Secret Protection7/17/20015/15/2002, 67 FR 34614 254.137Reporting Schedule7/17/20015/15/2002, 67 FR 34614 254.138Issuance of Source Inventory Report7/17/20015/15/2002, 67 FR 34614 Subpart B: Reporting Requirements for Large Sources254.203Contents of Subpart B Annual Emissions Report7/17/20015/15/2002, 67 FR 34614 254.204Complete Reports7/17/20015/15/2002, 67 FR 34614 Subpart C: Reporting Requirements for Other Sources254.303Contents of Subpart C Annual Emissions Report7/17/20015/15/2002, 67 FR 34614 254.306Complete Reports7/17/20015/15/2002, 67 FR 34614 Subpart E: Seasonal Emissions Report Under ERMS254.501Contents of a Seasonal Emissions Report7/17/20015/15/2002, 67 FR 34614 Part 255: General Conformity: Criteria and Procedures255.100Purpose3/6/199712/23/1997, 62 FR 67000 255.110Federal Requirement3/6/199712/23/1997, 62 FR 67000 255.120Applicability3/6/199712/23/1997, 62 FR 67000 255.140Definitions3/6/199712/23/1997, 62 FR 67000 255.150Abbreviations3/6/199712/23/1997, 62 FR 67000 255.160Incorporations by Reference3/6/199712/23/1997, 62 FR 67000 255.170Activities Exempt From Conformity Analysis3/6/199712/23/1997, 62 FR 67000 255.180Conformity Analysis3/6/199712/23/1997, 62 FR 67000 255.190Reporting Requirements3/6/199712/23/1997, 62 FR 67000 255.200Public Participation3/6/199712/23/1997, 62 FR 67000 255.210Frequency of Conformity Determinations3/6/199712/23/1997, 62 FR 67000 255.220Criteria for Determining Conformity of General Federal Actions3/6/199712/23/1997, 62 FR 67000 255.230Procedures for Conformity Determinations of General Federal Actions3/6/199712/23/1997, 62 FR 67000 255.240Mitigation of Air Quality Impacts3/6/199712/23/1997, 62 FR 67000 Part 276: Procedures To Be Followed in the Performance of Inspections of Motor Vehicle EmissionsSubpart A: General Provisions276.101Purpose and Applicability6/28/20118/13/2014, 79 FR 47377 276.102Definitions1/30/20128/13/2014, 79 FR 47377 276.103Abbreviations6/28/20118/13/2014, 79 FR 47377 276.104Incorporations by Reference1/30/20128/13/2014, 79 FR 47377 276.105Sunset Provisions1/30/20128/13/2014, 79 FR 47377 Subpart B: Vehicle Emissions Inspection Procedures276.201General Description of Vehicle Emissions Inspection Procedures1/30/20128/13/2014, 79 FR 47377 276.202Pollutants To Be Tested—Exhaust Test9/28/19988/13/2014, 79 FR 47377 276.203Dilution—Steady-State Idle Exhaust Test and Transient Loaded Mode Exhaust Test6/28/20118/13/2014, 79 FR 47377 276.204Steady-State Idle Exhaust Emissions Test Procedures6/28/20118/13/2014, 79 FR 47377 276.205Evaporative System Integrity Test Procedures6/28/20118/13/2014, 79 FR 47377 276.206Engine and Fuel Type Modifications6/14/19968/13/2014, 79 FR 47377 276.208On-Road Remote Sensing Test Procedures9/28/19988/13/2014, 79 FR 47377 276.209On-Board Diagnostic Test Procedures6/28/20118/13/2014, 79 FR 47377 276.210Visual Inspection Test Procedures1/30/20128/13/2014, 79 FR 47377276.210 Subpart C: Sticker or Certificate Issuance, Display, and Possession276.301General Requirements6/28/20118/13/2014, 79 FR 47377 276.302Determination of Affected Counties1/30/20128/13/2014, 79 FR 47377 276.303Emissions Inspection Sticker or Certificate Design and Content6/28/20118/13/2014, 79 FR 47377 Subpart D: Waiver and Economic Hardship Extension Requirements276.401Waiver Requirements6/28/20118/13/2014, 79 FR 47377 276.403Denial or Issuance of Waiver1/30/20128/13/2014, 79 FR 47377 276.404Economic Hardship Extension Requirements1/30/20128/13/2014, 79 FR 47377 276.405Outside of Affected Counties Annual Exemption Requirements1/30/20128/13/2014, 79 FR 47377 Subpart E: Test Equipment Specifications276.501General Requirements6/28/20118/13/2014, 79 FR 47377 276.502Steady-State Idle Exhaust Test Analysis Systems Functional Requirements6/28/20118/13/2014, 79 FR 47377 276.503Steady-State Idle Exhaust Test Analysis Systems Performance Criteria6/28/20118/13/2014, 79 FR 47377 276.504Evaporative System Integrity Test Functional Requirements and Performance Criteria6/28/20118/13/2014, 79 FR 47377 276.507On-Road Remote Sensing Test Systems Functional Requirements and Performance Criteria6/28/20118/13/2014, 79 FR 47377 276.508On-Board Diagnostic Test Systems Functional Requirements and Performance Criteria6/28/20118/13/2014, 79 FR 47377 Subpart F: Equipment Maintenance and Calibration276.601Steady-State Idle Test Equipment Maintenance9/28/19988/13/2014, 79 FR 47377 276.602Steady-State Idle Test Equipment Calibration6/28/20118/13/2014, 79 FR 47377 276.603Evaporative System Integrity Test Maintenance and Calibration9/28/19988/13/2014, 79 FR 47377 276.604Record Keeping6/28/20118/13/2014, 79 FR 47377 276.606On-Road Remote Sensing Test Systems Maintenance and Calibration9/28/19988/13/2014, 79 FR 47377 276.607On-Board Diagnostic Test Systems Maintenance and Calibration9/28/19988/13/2014, 79 FR 47377 Subpart G: Fleet Self-Testing Requirements276.701General Requirements6/28/20118/13/2014, 79 FR 47377 276.702Fleet Inspection Permit6/28/20118/13/2014, 79 FR 47377 276.703Fleet Inspection Permittee Operating Requirements6/28/20118/13/2014, 79 FR 47377 276.704Private Official Inspection Station Auditing and Surveillance6/28/20118/13/2014, 79 FR 47377 276.705Fleet Vehicle Inspection Procedures (Renumbered)6/14/19968/13/2014, 79 FR 47377 Subpart H: Grievance Procedure276.801General Requirements6/14/19968/13/2014, 79 FR 47377 276.802Procedure for Filing Grievance6/28/20118/13/2014, 79 FR 47377 276.803Agency Investigation6/28/20118/13/2014, 79 FR 47377 276.804Review of Agency's Determination6/14/19968/13/2014, 79 FR 47377 Subpart I: Notices276.901General Requirements6/28/20118/13/2014, 79 FR 47377 276.902Vehicle Emissions Test Notice6/28/20118/13/2014, 79 FR 47377 Subpart J: Reciprocity With Other Jurisdictions276.1001Requirements for Vehicles Registered in Affected Counties and Located in Other Jurisdictions Requiring Vehicle Emissions Inspection6/28/20118/13/2014, 79 FR 47377 276.1002Requirements for Vehicles Registered in Other Jurisdictions Requiring Vehicle Emissions Inspection and Located in an Affected County6/28/20118/13/2014, 79 FR 47377 Subpart K: Repair Facility Performance Reporting276.1101Requirements for Collecting and Reporting Data Pertaining to the Repair of Vehicles That Failed or Were Rejected From an Emissions Inspection6/28/20118/13/2014, 79 FR 47377 Part 283: General Procedures for Emissions Tests AveragingSubpart A: Introduction283.110Purpose9/11/20005/9/2003, 68 FR 24885 283.120Applicability9/11/20005/9/2003, 68 FR 24885 283.130Definitions9/11/20005/9/2003, 68 FR 24885 Subpart B: Procedures for Averaging of Test Results283.210Criteria for Averaging Tests9/11/20005/9/2003, 68 FR 24885 283.220Test Plan Requirements9/11/20005/9/2003, 68 FR 24885 283.230Changes to the Test Plan9/11/20005/9/2003, 68 FR 24885 283.240Averaging Procedure9/11/20005/9/2003, 68 FR 24885 283.250Compliance Determination9/11/20005/9/2003, 68 FR 24885 State Statutes20 ILCS 605/46.13aCivil Administrative Code9/21/19928/30/1993, 58 FR 45448Subsection 46.13(a) [Approved Under Public Act 87-1177]. 415 ILCS 5/9Illinois Environmental Protection Act6/21/19965/29/2002, 67 FR 37323Section 9(f) [Approved Under Public Act 89-491]. 415 ILCS 5/9.1Illinois Environmental Protection Act9/17/199112/17/1992, 57 FR 59928(Ch. 111 1/2, par. 1009.1) par. 1009.1(a), (b), (c), (d) and (f). [Approved Under Public Act 87-555]. 415 ILCS 5/9.9Illinois Environmental Protection Act7/1/200111/8/2001, 66 FR 56454Section 9.9(f) [Approved Under Public Act 92-0012]. 415 ILCS 5/39.5Illinois Environmental Protection Act9/26/19928/30/1993, 58 FR 45448Subsection 20 [Approved Under Public Act 87-1213]. 625 ILCS 5/13BIllinois Vehicle Code1/18/19947/25/1996, 61 FR 38582625 ILCS 5/13B [Approved Under Public Act 88-533].

(d) EPA approved state source-specific requirements.

EPA-Approved Illinois Source-Specific Requirements

Name of source Order/permit No. State
effective
date
EPA
approval
date
Comments Alton Steel180200093/5/20182/21/2023, 88 FR 10464 Alumax Incorporated, Morris, ILPCB AS 92-139/1/19942/1/1996, 61 FR 3575 Argonne National LaboratoryPCB AS 03-412/18/20037/28/2004, 69 FR 44967 Bema Film Systems, Incorporated, DuPage CoPCB AS 00-111/18/200111/30/2001, 66 FR 59702 Calpine Corporation (Zion Energy Center)PCB 16-11212/19/201612/9/2019, 84 FR 67191As amended on 8/17/2017. Central Can Company (CCC), Chicago, ILPCB AS 94-188/6/1998, eff. 7/1/19913/18/1999, 64 FR 13346 Chase Products Company, Broadview (Cook Co.)PCB AS 94-45/16/19966/9/1997, 62 FR 31341 City Water, Light & Power, City of Springfield90900466/23/20117/6/2012, 77 FR 39943Joint Construction and Operating Permit. CP-D Acquisition Company, LLC. (formerly Cromwell-Phoenix, Inc)PCB AS 03-0511/20/200310/29/2008, 73 FR 64213 Exelon Generation, LLCPCB 16-1069/13/201612/9/2019, 84 FR 67191 Ford Motor CompanyPCB, AS 02-0311/21/20023/22/2004, 69 FR 13239 Ford Motor Company Chicago Assembly PlantPCB, AS 05-59/1/20059/6/2006, 71 FR 52464 Greif Packaging, LLC, Naperville, DuPage CoPCB AS 2011-014/5/201210/22/2012, 77 FR 64422 IL Power Company's Baldwin Power StationPCB 79-79/8/19834/18/1990, 55 FR 14419Emission limits within Paragraph 1 of Final Order. Kincaid Generation, LLC90500226/24/20117/6/2012, 77 FR 39943Joint Construction and Operating Permit. Laclede Steel Sulfur dioxide plan9307003011/18/19934/20/1994, 59 FR 18752FESOP for boilers and reheat furnaces. Leisure Properties LLC/D/B/A Crownline Boats, West Frankfort, IllinoisPCB AS 04-017/22/20044/20/2012, 77 FR 23622Effective date identified in error as 7/22/2002 in the document heading. Due to ownership change, the Board transferred the adjusted standard to Leisure Properties LLC D/B/A Crownline Boats by Board order AS04-l, effective 10/7/2010. Louis Berkman Company, d/b/a/ the Swenson Spreader Company's Lindenwood, Ogle CoPCB, AS 97-55/7/19985/27/2004, 69 FR 30224 LTV Steel Company, Inc.981200915/14/19997/14/1999, 64 FR 37847Federally Enforceable State Operating Permit. Midwest Generation, LLCPCB 12-1218/23/20127/20/2015, 80 FR 42726Certificate of Acceptance, dated 8/24/2012, filed with the Illinois Pollution Control Board Clerk's Office 8/27/2012. Midwest Generation, LLCPCB 13-244/4/20137/20/2015, 80 FR 42726Certificate of Acceptance, dated 5/16/13, filed with the Illinois Pollution Control Board Clerk's Office 5/17/2013. National Steel Corporation, Granite City Division9501000510/21/19973/11/1998, 63 FR 11842Joint Construction and Operating Permit. Quantum Chemical Corporation, Morris, Aux Sable Township, Grundy CoPCB AS 92-1410/7/19934/3/1995, 60 FR 16803adjusted standard. Reynolds Metals Company's McCook Sheet and Plate Plant in McCook, IL (in Cook Co.)PCB AS 91-89/21/19951/21/1997, 62 FR 2916 Royal Fiberglass Products, d/b/a Viking PoolsPCB AS 09-149/5/20137/14/2014, 79 FR 40673 Solar Corporation, Libertyville, ILPCB AS 94-27/20/19952/23/1998, 63 FR 8855 Stepan Company Millsdale Plant197800AAE10/30/20208/13/2021, 86 FR 44616 Sun Chemical Corporation, Northlake, ILPCB AS 99-45/20/19999/13/1999, 64 FR 49400 Vonco Products, Incorporated, Lake CoPCB AS 00-121/18/200111/30/2001, 66 FR 59704

(e) EPA approved nonregulatory and quasi-regulatory provisions.

EPA-Approved Illinois Nonregulatory and Quasi-Regulatory Provisions

Name of SIP provision Applicable geographic or nonattainment area State submittal date EPA approval date Comments Air quality surveillance networkState-wide12/20/19793/4/1981, 46 FR 15137 Coal banChicago Area10/22/19733/2/1976, 41 FR 8956 Compliance schedulesState-wide3/13/1973,
4/3/1973,
5/3/1973,
6/15/1973, and
8/7/1973
3/2/1976, 41 FR 8956 Ozone (8-hour, 2008) certification of emissions statement regulationsChicago and St. Louis areas5/9/20177/11/2017, 82 FR 31913Certification that Illinois' previously approved regulations at 35 IAC part 254 meet the emission statement requirements for the 2008 ozone NAAQS. Ozone (8-hour, 2008) Nonattainment New Source Review RequirementsChicago area5/23/20182/6/2019, 84 FR 2063 Ozone (8-hour, 2015) certification of emissions statement regulationsChicago and St. Louis areas5/16/20191/24/2020, 85 FR 4231Certification that Illinois' previously approved regulations at 35 IAC Part 254 meet the emissions statement requirements for the 2015 ozone NAAQS. Regional haze planStatewide6/24/20117/6/2012, 77 FR 39943 Regional Haze Progress ReportStatewide2/1/20174/12/2018, 83 FR 15744 Small business stationary source technical and environmental compliance assistance programState-wide11/12/19928/30/1993, 58 FR 45451 Total Suspended Particulate Control Strategy analysisState-wide10/1/19819/30/1982, 47 FR 43054 Transportation control planChicago Area4/17/19733/2/1976, 41 FR 8956 Transportation control planChicago Area4/30/19801/27/1981, 46 FR 8472 Transportation control planChicago Area8/20/1980 and 3/20/198111/16/1981, 46 FR 56196 Transportation control planPeoria Area10/15/198011/16/1981, 46 FR 56196 Transportation control planSt. Louis Area4/1/198111/16/1981, 46 FR 56196 Transportation control plansChicago and St. Louis areas12/3/198210/4/1990, 55 FR 40658 Attainment and Maintenance PlansCarbon monoxide attainment demonstrationChicago Area5/4/198310/4/1990, 55 FR 40658 Lead (1978) attainment and maintenance planGranite City area9/30/19837/24/1984, 49 FR 29790 Lead (2008)—Clean Data DeterminationChicago AreaN/A8/25/2015, 80 FR 51131 Lead (2008) Redesignation and maintenance planChicago and Granite City areas9/22/20163/28/2018, 83 FR 13198 Ozone (1-hour) attainment demonstrationChicago area12/26/200011/13/2001, 66 FR 56904 Ozone (1-hour) attainment demonstrationSt. Louis area11/15/1999,
2/10/2000,
4/13/2001, and 4/30/2001
6/26/2001, 66 FR 33996EPA is disapproving the request for an exemption from the NOX NSR and certain NOX conformity requirements for Madison, Monroe, and St. Clair Counties. Ozone (1-hour) attainment plan revisionChicago severe nonattainment area4/11/20039/15/2003, 68 FR 53887 Ozone (1-hour) redesignation and maintenance planJersey County11/12/19933/14/1995, 60 FR 13634 Ozone (1-hour) redesignation and maintenance planSt. Louis Area12/30/20025/12/2003, 68 FR 25542 Ozone (1-hour revoked) finding of attainmentChicago area1/30/200712/30/2008, 73 FR 79652 Ozone (8-hour, 1997) Determination of AttainmentChicago areaN/A7/8/2011, 76 FR 40262Correction to codification published on 3/12/2010 at 75 FR 12088. Ozone (8-hour, 1997) Determination of AttainmentSt. Louis areaN/A6/9/2011, 76 FR 33647 Ozone (8-hour, 1997) maintenance plan revisionChicago area3/28/201410/6/2014, 79 FR 60073Revised VOC and NOX Motor Vehicle Emissions Budgets (MVEB) for the year 2025. Ozone (8-hour, 1997) redesignation and maintenance planChicago area7/23/2009, and 9/16/20118/13/2012, 77 FR 48062 Ozone (8-hour, 1997) redesignation and maintenance planSt. Louis area5/26/2010, and 9/16/20116/12/2012, 77 FR 34819 Ozone (8-hour, 1997) second maintenance planSt. Louis area8/24/20225/30/2023, 88 FR 34449Jersey County only. Ozone (8-hour, 2008) Determination of AttainmentSt. Louis areaN/A6/27/2016, 81 FR 41444determination that the area attained by the 7/20/2016 attainment date. Ozone (8-hour, 2008) redesignation and maintenance planSt. Louis area5/8/20173/1/2018, 83 FR 8756 Ozone (8-hour, 2008) redesignation and maintenance planChicago Area1/25/20225/20/2022, 87 FR 30828 PM10 maintenance planGranite City area3/19/1996, and 10/15/19963/11/1998, 47 FR 11842 PM10 maintenance planLake Calumet (Southeast Chicago), Cook County8/2/2005, as supplemented on 9/8/20059/22/2005, 70 FR 55545 PM10 maintenance planLaSalle County6/2/1995, and 1/9/19968/8/1996, 61 FR 41342 PM10 maintenance planLyons Township (McCook), Cook County8/2/20059/22/2005, 70 FR 55541 PM2.5 (1997)—Clean Data DeterminationSt. Louis areaN/A5/23/2011, 76 FR 29652 PM2.5 (1997)—Determination of AttainmentChicago areaN/A11/27/2009, 74 FR 62243 PM2.5 (1997)—Determination of AttainmentSt. Louis areaN/A6/27/2012, 77 FR 38184 PM2.5 (1997)—maintenance plan and motor vehicle emissions budgetsChicago area10/15/2010, supplemented on 9/16/2011, and 5/6/201310/2/2013, 78 FR 60704 PM2.5 (1997)—maintenance plan and motor vehicle emissions budgetsSt. Louis area12/6/20185/28/2019, 84 FR 24395 Sulfur dioxide (2010) nonattainment plansLemont and Pekin3/2/20162/1/2018, 83 FR 4591 Sulfur dioxide (2010) nonattainment planAlton Township12/31/20182/21/2023, 88 FR 10464 Sulfur dioxide control strategyCincinnati, Pekin and Elm Grove Townships in Tazewell County and Logan and Limestone Townships in Peoria County3/24/1983 and 5/3/19838/8/1984, 49 FR 31685Correction to codification published on 2/9/1994 at 59 FR 5955. Sulfur dioxide maintenance planPeoria and Hollis Townships in Peoria County and Groveland Township in Tazewell County11/10/199460 FR 17001, 4/4/1995 Sulfur dioxide (2010) maintenance planLemont and Pekin5/24/20195/26/2020, 85 FR 31378 Emission InventoriesEmission inventory—1990 (1-hour ozone)Chicago and St. Louis areas11/12/19933/14/1995, 60 FR 13631 Emission inventories—2002 (NOX, primary PM2.5, SO2, ammonia, and VOC)Chicago area10/15/2010, supplemented on 5/6/201310/2/2013, 78 FR 60704 Emissions inventory—2002 (1997 8-hour ozone)St. Louis area5/26/2010, supplemented on 9/16/20116/12/2012, 77 FR 34819 Emissions inventory—2002 (1997 8-hour ozone)Chicago area6/21/2006, supplemented on 9/16/20118/13/2012, 77 FR 48062 Emissions inventories—2008 (NOX, primary PM2.5, SO2, ammonia, and VOC)St. Louis area12/6/20185/28/2019, 84 FR 24395 Emission inventory—2011 (2008 8-hour ozone)St. Louis area9/3/20143/7/2016, 81 FR 11671 Emission inventory—2011 (2008 8-hour ozone)Chicago area1/10/20198/19/2020, 85 FR 50955 Emission inventory—2012 (2008 Lead)Chicago and Granite City areas9/22/20163/28/2018, 83 FR 13198 Emissions inventory—2017 (2015 8-hour ozone)Chicago and St. Louis areas10/22/20208/15/2023, 88 FR 55383 Moderate Area & Above Ozone Requirements15 percent rate-of-progress and 3 percent contingency plansChicago and St. Louis areas11/15/199312/18/1997, 62 FR 66279 I/M certification (8-hour, 2008 ozone)Chicago area1/10/20198/19/2020, 85 FR 50955 Negative declaration—Natural gas/gasoline processing plantsState-wide11/14/198511/24/1986, 51 FR 42221 Negative declaration—Aerospace manufacturing and rework industryChicago and St. Louis areas10/11/19962/11/1997, 62 FR 6127 Negative declaration—Industrial cleaning solvents categorySt. Louis area10/2/19981/6/1999, 64 FR 756 Negative declaration—Industrial cleaning solvents categoryChicago area12/23/19992/7/2001, 66 FR 9206 Negative declaration—Industrial wastewater categoryChicago area12/23/19994/27/2001, 66 FR 21096 Negative declaration—Industrial wastewater categorySt. Louis area10/2/19981/6/1999, 64 FR 756 Negative declaration—Shipbuilding and ship repair industryChicago and St. Louis areas10/11/19962/11/1997, 62 FR 6126 2008 8-hour Ozone Negative DeclarationsChicago area1/10/20198/13/2021, 86 FR 44616Includes: Aerospace Manufacturing and Rework Facilities, High-Density Polyethylene, Polypropylene, and Polystyrene Resins, Natural Gas/Gasoline Processing Plants, Oil and Natural Gas Industry, Shipbuilding and Ship Repair Industry, and Vegetable Oil Processing. 2008 8-hour Ozone Section 182(b)(2) VOC RACT Rules CertificationChicago area1/10/20198/13/2021, 86 FR 44616 2008 8-hour Ozone Non-CTG RACT Demonstration—Chicago area1/10/20198/13/2021, 86 FR 44616Industrial Wastewater Category. 2008 8-hour Ozone Serious Planning ElementsChicago Area1/25/20225/20/2022, 87 FR 308282035 VOC and NOX motor vehicle emissions budgets, VOC RACT certification, Enhanced Motor Vehicle Inspection and Maintenance Program certification, clean-fuel vehicle programs certification, enhanced monitoring of ozone and ozone precursors certification. 2008 8-hour Ozone NOX RACT WaiverChicago Area1/25/20225/20/2022, 87 FR 30828 NOX RACT waiver (1997 8-hour ozone)Chicago and St. Louis areas7/29/20102/22/2011, 76 FR 9655 NOX waiver—RACT, NSR, vehicle I/M, and general conformityChicago severe nonattainment area7/13/19941/26/1996, 61 FR 2428does not cover the exemption of NOX transportation conformity requirements. NOX waiver—transportation conformity requirementsChicago severe nonattainment area6/20/19952/12/1996, 61 FR 5291 Photochemical assessment ambient monitoring system (PAMS)11/4/19932/25/1994, 59 FR 9091 Post-1996 Rate Of Progress PlanChicago area12/18/1997,
12/17/1999,
1/14/2000,
1/21/2000, and
2/17/2000
12/18/2000, 65 FR 78961Includes Contingency measure plan and Transportation Control Measures (TCMs). Transportation control measures as part of the 15 percent rate-of-progress and 3 percent contingency plansSt. Louis area11/15/199312/18/1997, 62 FR 66279Work trip reductions; transit improvements; and traffic flow improvements. Vehicle miles traveled (VMT) SIP and, transportation control measures (TCMs) as part of the 15 percent rate-of-progress planChicago area7/14/19949/21/1995, 60 FR 48896 Section 110(a)(2) Infrastructure Requirements1997 8-hour Ozone NAAQS Infrastructure RequirementsStatewide12/12/2007 and 9/22/20204/8/2022, 87 FR 20715All CAA infrastructure elements under 110(a)(2) have been approved except (D)(i)(I) [Prongs 1 and 2]. A FIP is in place for these elements. 1997 PM2.5 NAAQS Infrastructure RequirementsStatewide12/12/2007 and 9/22/20204/8/2022, 87 FR 20715All CAA infrastructure elements under 110(a)(2) have been approved except (D)(i)(I) [Prongs 1 and 2]. A FIP is in place for these elements. 2006 24-hour PM2.5 NAAQS Infrastructure RequirementsStatewide8/9/2011, supplemented on 8/25/2011, 6/27/2012,
7/5/2017 and 9/22/2020
4/8/2022, 87 FR 20715All CAA infrastructure elements under 110(a)(2) have been approved except (D)(i)(I) [Prongs 1 and 2]. A FIP is in place for these elements. 2008 Lead NAAQS Infrastructure RequirementsStatewide12/31/2012,
7/5/2017 and 9/22/2020
4/8/2022, 87 FR 20715All CAA infrastructure elements under 110(a)(2) have been approved. 2008 Ozone NAAQS Infrastructure RequirementsStatewide12/31/2012,
7/5/2017 and 9/22/2020
4/8/2022, 87 FR 20715All CAA infrastructure elements under 110(a)(2) have been approved except (D)(i)(I) [Prongs 1 and 2]. A FIP is in place for these elements. 2010 NO2 NAAQS Infrastructure RequirementsStatewide12/31/2012,
7/5/2017 and 9/22/2020
4/8/2022, 87 FR 20715All CAA infrastructure elements under 110(a)(2) have been approved. 2010 SO2 NAAQS Infrastructure RequirementsStatewide12/31/2012,
7/5/2017 and 9/22/2020
4/8/2022, 87 FR 20715All CAA infrastructure elements under 110(a)(2) have been approved except (D)(i)(I) [Prongs 1 and 2], which have not yet been submitted. 2012 PM2.5 NAAQS Infrastructure RequirementsStatewide9/29/2017 and 9/22/20204/8/2022, 87 FR 20715All CAA infrastructure elements under 110(a)(2) have been approved except (D)(i)(II) Prong 4. 2015 Ozone NAAQS Infrastructure RequirementsStatewide5/16/2019 and 9/22/20202/13/2023, 88 FR 9336All CAA infrastructure elements under 110(a)(2) have been approved except (D)(i)(I) Prongs 1, 2, which are disapproved, and no action has been taken on (D)(i)(II) Prong 4.
[82 FR 30638, June 30, 2017] Editorial Notes:1. For Federal Register citations affecting § 52.720, see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume and at www.govinfo.gov..

2. At 83 FR 50855, Oct. 10, 2018, § 52.720(c) was amended in part by revising entries for 201.103, 201.104, and 211.4720; however, the revisions could not be completed because those entries did not exist.

3. At 86 FR 54627, Oct. 4, 2021, § 52.720(c) was amended in part by adding entries for 243.120, 243.122, 243.123, 243.124, and 243.126 under the heading “Subpart B: Standards and Measurement Methods.” Those entries already existed, resulting in duplicate entries. At 89 FR 2885, Jan. 17, 2024, the duplicate entry for 243.122 in § 52.720(c) was removed, effective Feb. 16, 2024.

§ 52.721 - Classification of regions.

The Illinois plan was evaluated on the basis of the following classifications:

Air quality control region Pollutant Particulate matter Sulfur oxides Nitrogen dioxide Carbon monoxide Ozone Burlington-Keokuk InterstateIIIIIIIIIII East Central Illinois IntrastateIIIIIIIIIIIIII Metropolitan Chicago Interstate (Indiana-Illinois)IIIII Metropolitan Dubuque InterstateIIIIIIIIIIIII Metropolitan Quad Cities InterstateIIIIIIIIIIIII Metropolitan St. Louis Interstate (Missouri-Illinois)IIIIIII North Central Illinois IntrastateIIIAIIIIIIIII Paducah (Kentucky)-Cairo (Illinois) InterstateIIIIIIIIIIII Rockford (Illinois)-Janesville-Beloit (Wisconsin) InterstateIIIIIIIIIIIIII Southeast Illinois IntrastateIIIIIIIIIIIIII West Central Illinois IntrastateIIAIIIIIIIII
[37 FR 10862, May 31, 1972, as amended at 39 FR 16346, May 8, 1974; 45 FR 11493, Feb. 21, 1980]

§ 52.722 - Approval status.

(a) With the exceptions set forth in this subpart, the Administrator approved Illinois' plan for the attainment and maintenance of the National Ambient Air Quality Standards under section 110 of the Clean Air Act. Furthermore, the Administrator finds the plan satisfies all requirements of part D, title I of the Clean Air Act as amended in 1977, except as noted below. In addition, continued satisfaction of the requirements of part D for the ozone portion of the SIP depends on the adoption and submittal of RACT requirements by July 1, 1980, for the sources covered by CTGs between January 1978 and January 1979 and adoption and submittal by each subsequent January of additional RACT requirements for sources covered by CTGs issued by the previous January.

(b) The Administrator finds that the transportation control plans for the East St. Louis and Chicago areas submitted on December 3, 1982, satisfy the related requirements of part D, title I of the Clean Air Act, as amended in 1977.

(c) The Administrator finds that the carbon monoxide control strategy submitted on May 4, 1983, satisfies all requirements of part D, title I of the Clean Air Act, as amended in 1977, except for section 172(b)(6).

[55 FR 40661, Oct. 4, 1990]

§ 52.723 - [Reserved]

§ 52.724 - Control strategy: Sulfur dioxide.

(a) Part D—Conditional Approval—The Illinois plan is approved provided that the following condition is satisfied:

(1) The plan includes a reanalysis of the Pekin, Illinois area, a submittal of the analysis results to USEPA, the proposal of any additional regulations to the Illinois Pollution Control Board necessary to insure attainment and maintenance of the sulfur dioxide standard, and the promulgation of any necessary regulations. The State must complete the reanalysis, submit the results to USEPA and submit any necessary, additional regulations to the Illinois Pollution Control Board by September 30, 1980. Any necessary regulation must be finally promulgated by the State and submitted to USEPA by September 30, 1981.

(2) Extension of Condition—USEPA approves the date of July 1, 1984 for submitting the draft sulfur dioxide rule revisions and supporting documentation as required in (a)(1) for Peoria, Hollis and Groveland Townships in Illinois. The State must complete final rule adoption as expeditiously as possible but no later than December 31, 1985.

(b) Part D—Disapproval—USEPA disapproves Rules 204(c)(1)(B), Rule 204(c)(1)(C), Rule 204(e)(1) and Rule 204(e)(2) for those sources for which these rules represent a relaxation of the federally enforceable State Implementation Plan. Rule 204(c)(1)(B), Rule 204(c)(1)(C), Rule 204(e)(1) and Rule 204(e)(2) are approved as not representing relaxations of the State Implementation Plan for the following sources:

Sources of 10 Million Btu per Hour or More Not Increasing Allowable Sulfur Dioxide Emissions as a Result of Record Rules 204(c) and 204(e) Because New Allowable Emissions Rate is Same as or Less Than Old Allowable Rate Pounds per Hour (Pounds per Million Btu)

County Name Emissions formerly allowable 1Emissions now allowable without new permit application 2BooneChrysler1,760 (4.4)1,760 (4.4) ChampaignChanute Air Base1,317 (3.0)1,317 (3.0) CrawfordCIPS8,242 (5.1)8,242 (5.1) DouglasUSI Chemicals8,022 (5.3)8,022 (5.3) FultonFreeman Coal22.2 (1.2)22.2 (1.2) La SalleDel Monte296 (3.9)296 (3.9) MassacEEI Joppa36,865 (3.6)36,865 (3.6) MontgomeryCIPS55,555 (5.8)55,555 (5.8) Morgan......do24,000 (6.0)20,800 (5.2) PutnamIllinois Power17,051 (5.8)17,051 (5.8) Randolph......do 381,339 (4.6)81,339 (4.6) Rock IslandInternational Harvester1,643 (4.35)1,643 (4.35) WilliamsonMarion Correctional396 (5.7)396 (5.7)

1 6.0 lbs/MMBTU of existing coal fired capacity or total 204(e)(2) emissions less actual oil fired and NSPS emissions, whichever is lower.

2 Maximum allowable emissions for existing coal fired capacity according to revised rules 204(c) and 204(e) consolidated, usually equally equalling total emissions as given by 204(e)(2) less actual oil fired NSPS emissions. (In the one case wherein the new allowable limit is less than that given by 204(e)(2) the allowable emissions were determined by 204(e)(1) with which the source is required to comply.)

3 Source is in compliance per 204(e)(3).

CIPS = Central Illinois Public Service.

EEI = Electric Energy Incorporated.

This disapproval does not in and of itself result in the growth restrictions of section 110(a)(2)(1).

(c) Disapproval—USEPA disapproves Rule 204(e)(4) as not being adequate to protect the NAAQS. This disapproval does not in and of itself result in the growth restrictions of section 110(a)(2)(I).

(d) Disapproval—USEPA disapproves Rule 204(f)(1)(D) as completely deregulating SO2 emissions from existing processes without providing an assessment of the ambient air quality impact or a showing that increasing the allowable emissions from these sources will not cause or contribute to violations of the NAAQS or PSD increments. This disapproval does not in and of itself result in the growth restrictions of section 110(a)(2)(I).

(e) Disapproval—USEPA disapproves Rule 204(h) for those sources for which USEPA has disapproved rules 204(c) and 204(e). This disapproval does not in and of itself result in the growth restrictions of section 110(a)(2)(I).

(f) Approval—USEPA approves rule 204(e)(3) for those sources able to show that the proposed emission rate will not cause or contribute to a violation of the NAAQS. The State must submit these emission limitations, along with the technical support to USEPA for approval.

(g) Part D—Approval—The State plan for Alton Township, Madison County, which consists of a federally Enforceable State Operating Permit controlling sulfur dioxide emissions from the boilers and reheat furnaces at Laclede Steel, which was submitted on November 18, 1993, is approved.

(h) Approval—On November 10, 1994, the Illinois Environmental Protection Agency submitted a sulfur dioxide redesignation request and maintenance plan for Peoria and Hollis Townships in Peoria County and Groveland Township in Tazewell County to redesignate the townships to attainment for sulfur dioxide. The redesignation request and maintenance plan meet the redesignation requirements in section 107(d)(3)(d) of the Clean Air Act (Act) as amended in 1990.

[45 FR 62806, 62809, Sept. 22, 1980, as amended at 50 FR 5250, Feb. 7, 1985; 59 FR 18753, Apr. 20, 1994; 60 FR 17001, Apr. 4, 1995]

§ 52.725 - Control strategy: Particulates.

(a) [Reserved]

(b) Part D—Disapproval. (1) U.S. EPA disapproves the provisions of Rule 203(f) which allow the use of an equivalent method without review and approval of that method. Any source subject to Rule 203(f) which chooses to use an equivalent method must have that equivalent method submitted to U.S. EPA and approved as a SIP revision.

(2) U.S. EPA disapproves the following portions of Rule 203(d)(5) which regulate the control of particulate matter from specific sources within the iron and steel industry: Rule 205(d)(5)(B)(ii), Rule 205(d)(5)(B)(iii), Rule 205(d)(5)(D), and Rule 205(d)(5)(K).

(3) USEPA disapproves a proposed SIP revision submitted by the State on May 12, 1982, in the form of a May 18, 1981 Consent Decree (Civil Action 81-3009) to which USEPA, Illinois Environmental Protection Agency and National Steel Corporation are parties and a draft Alternative Control Strategy Permit. This submission was modified by the State, September 30, 1982, with the submission of a separate document embodying the elements of the Alternative Control Strategy. This separate document was intended to become an enforceable part of the SIP.

(c) Approval—On September 28, 1988, the State of Illinois submitted a committal SIP for particulate matter with an aerodynamic diameter equal to or less than 10 micrometers (PM10) for the Illinois Group II areas of concern in DuPage, Will, Rock Island, Macon, Randolph, and St. Clair Counties. The committal SIP contains all the requirements identified in the July 1, 1987, promulgation of the SIP requirements for PM10 at 52 FR 24681.

(d) Approval—On June 2, 1995, and January 9, 1996, the State of Illinois submitted a maintenance plan for the particulate matter nonattainment portion of LaSalle County, and requested that it be redesignated to attainment of the National Ambient Air Quality Standard for particulate matter. The redesignation request and maintenance plan satisfy all applicable requirements of the Clean Air Act.

(e) Approval—On March 19, 1996, and October 15, 1996, Illinois submitted requests to redesignate the Granite City Particulate Matter (PM) nonattainment area to attainment status for the PM National Ambient Air Quality Standards (NAAQS), as well as a maintenance plan for the Granite City area to ensure continued attainment of the NAAQS. The redesignation request and maintenance plan satisfy all applicable requirements of the Clean Air Act.

(f) On November 14, 1995, May 9, 1996, and June 14, 1996, the State of Illinois submitted State Implementation Plan (SIP) revision requests to meet commitments related to the conditional approval of Illinois' May 15, 1992, SIP submittal for the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM) nonattainment areas. The EPA is approving the SIP revision request as it applies to the McCook PM nonattainment area. For the McCook PM nonattainment area, all of the deficiencies of the May 15, 1992, submittal have been corrected.

(g) Approval—On May 5, 1992, November 14, 1995, May 9, 1996, June 14, 1996, February 3, 1997, October 16, 1997, October 21, 1997, February 1, 1999, and May 19, 1999, Illinois submitted SIP revision requests to meet the Part D particulate matter (PM) nonattainment plan requirements for the Lake Calumet, Granite City and McCook moderate PM nonattainment areas. The submittals include federally enforceable construction permit, application number 93040047, issued on January 11, 1999, to Acme Steel Company. The part D plans for these areas are approved.

(h) Approval—On August 2, 2005, the State of Illinois submitted a request to redesignate the Lyons Township (McCook), Cook County particulate matter nonattainment area to attainment of the NAAQS for particulate matter with an aerodynamic diameter less than or equal to a nominal 10 micrometers (PM-10). In its submittal, the State also requested that EPA approve the maintenance plan for the area into the Illinois PM SIP. The redesignation request and maintenance plan meet the redesignation requirements of the Clean Air Act.

(i) Approval—On August 2, 2005, and as supplemented on September 8, 2005, the State of Illinois submitted a request to redesignate the Lake Calumet (Southeast Chicago), Cook County particulate matter nonattainment area to attainment of the NAAQS for particulate matter with an aerodynamic diameter less than or equal to a nominal 10 micrometers (PM-10). In its submittal, the State also requested that EPA approve the maintenance plan for the area into the Illinois PM SIP. The redesignation request and maintenance plan meet the redesignation requirements of the Clean Air Act.

(j) Determination of Attainment. EPA has determined, as of November 27, 2009, that the Chicago-Gary-Lake County, IL-IN PM2.5 nonattainment area has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 51.1004(c), suspends the requirements for this area to submit an attainment demonstration, associated reasonably available control measures, reasonable further progress, contingency measures, and other plan elements related to attainment of the standard for as long as this area continues to meet the 1997 PM2.5 NAAQS.

(k) Determination of attainment. EPA has determined, as of May 23, 2011, that the St. Louis (MO-IL) metropolitan 1997 PM2.5 nonattainment area has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 51.1004(c), suspends the requirements for this area to submit an attainment demonstration, associated reasonably available control measures, reasonable further progress, contingency measures, and other plan elements related to attainment of the standards for as long as the area continues to meet the 1997 PM2.5 NAAQS. In addition, based upon review of the air quality data for the 3-year period 2007 to 2009, EPA has determined that the St. Louis (MO-IL) PM2.5 nonattainment area has attained the 1997 PM2.5 NAAQS by the applicable attainment date of April 5, 2010.

(l) Approval—The 1997 annual PM2.5 maintenance plan for the Illinois portion of the Chicago-Gary-Lake County, IL-IN nonattainment area (including Cook, DuPage, Kane, Lake, McHenry and Will Counties, Aux Sable and Goose Lake Townships in Grundy County, and Oswego Township in Kendall County) has been approved as submitted on October 15, 2010, and supplemented on September 16, 2011, and May 6, 2013. The maintenance plan establishes 2008 and 2025 motor vehicle emissions budgets for this area of 127,951 tons per year for NOX and 5,100 tons per year for primary PM2.5 in 2008 and 44,224 tons per year for NOX and 2,377 tons per year for primary PM2.5 in 2025.

(m) Illinois' 2002 NOX, primary PM2.5, SO2, ammonia, and VOC emission inventories, as submitted on October 15, 2010, and supplemented on May 6, 2013, satisfy the emission inventory requirements of section 172(c)(3) of the Clean Air Act for the Chicago area.

[45 FR 11493, Feb. 21, 1980, as amended at 46 FR 44185, Sept. 3, 1981; 47 FR 26620, June 21, 1982; 48 FR 45246, Oct. 4, 1983; 49 FR 1905, Jan. 16, 1984; 55 FR 20266, May 16, 1990; 61 FR 41345, Aug. 8, 1996; 63 FR 11846, Mar. 11, 1998; 63 FR 47434, Sept. 8, 1998; 64 FR 37851, July 14, 1999; 70 FR 55545, 55549, Sept. 22, 2005; 74 FR 62249, Nov. 27, 2009; 76 FR 29656, May 23, 2011; 77 FR 38184, June 27, 2012; 78 FR 60706, Oct. 2, 2013]

§ 52.726 - Control strategy: Ozone.

(a) Part D—Conditional Approval—The Illinois plan is approved provided that the following conditions are satisfied:

(1) [Reserved]

(2) The State conducts a study to demonstrate that the 75 percent overall control efficiency requirement in Rule 205(n) represents RACT, submits the results of the study to USEPA, and submits any necessary regulations representing RACT to the Illinois Pollution Control Board. The State must comply with these conditions by February 28, 1981. Any necessary regulations must be finally promulgated by the State and submitted to USEPA by February 28, 1982.

(3) Extension of Condition—USEPA approves the date of July 31, 1984 for the State of Illinois to satisfy the condition of approval to the ozone State Implementation Plan listed in paragraph (a)(2) of this section.

(b) Disapproval—USEPA disapproves the compliance schedule in Rule 205(j) as it applies to loading rack controls for all emission sources subject to Rule 205(b)(1), as approved by USEPA on May 31, 1972 which were required to be in compliance by December 31, 1973. This disapproval does not in and of itself result in the growth restrictions of section 110(a)(2)(I).

(c) Negative Declarations—Stationary Source Categories. The State of Illinois has certified to the satisfaction of USEPA that no sources are located in the nonattainment areas of the State which are covered by the following Control Technique Guidelines:

(1) High density polyethylene and polypropylene manufacturers.

(2) Vegetable oil processing sources with volatile organic compound emissions equal to or greater than 100 tons per year.

(d) Part D Disapproval—The Administrator finds that Illinois' ozone plan for Cook, Lake, DuPage and Kane Counties, which was required to be submitted by July 1, 1982, does not satisfy all the requirements of Part D, Title I of the Clean Air Act and, thus, is disapproved. No major new stationary source, of major modification of a stationary source, or volatile organic compounds may be constructed in Cook, Lake, DuPage or Kane Counties, unless the construction permit application is complete on or before November 16, 1988. This disapproval does not affect USEPA's approval (or conditional approval) of individual parts of Illinois' ozone plan, and they remain approved.

(e) Disapproval—The Administrator finds that the following State rules have not been demonstrated to be consistent with the reasonably available control technology requirements of section 172 of the Clean Air Act, as amended in 1977, and thus, are disapproved: subpart F, section 215.204(c); subpart F, section 215.206(b); subpart F, section 215.204(j)(4); subpart I; subpart AA; subpart PP; subpart QQ; subpart RR; subpart A, section 215.102; subpart T; subpart H, section 215.245; subpart F, section 215.207; and subpart A, section 215.107, all of title 35; Environmental Protection; subtitle B: Air Pollution; Chapter 1: Pollution Control Board of the Illinois Administrative Code (June 1989).

(f) On September 30, 1992, the State submitted rules regulating volatile organic compound emissions from gasoline dispensing facilities' motor vehicle fuel operations (Stage II vapor recovery rules) in the Chicago ozone nonattainment area. The Illinois Environmental Protection Agency Bureau of Air must as part of the program conduct inspections of facilities subject to this rule to ensure compliance with the applicable rules. These inspections will be conducted on an annual basis or an alternative schedule as approved in the USEPA Fiscal Year Inspection Program Plan.

(g) Approval—The Administrator approves the incorporation of the photochemical assessment ambient monitoring system submitted by Illinois on November 4, 1993, into the Illinois State Implementation Plan. This submittal satisfies 40 CFR 58.20(f) which requires the State to provide for the establishment and maintenance of photochemical assessment monitoring stations (PAMS) by November 12, 1993.

(h) Approval—On November 12, 1993, the Illinois Environmental Protection Agency submitted an ozone redesignation request and maintenance plan for Jersey County ozone nonattainment area and requested that Jersey County be redesignated to attainment for ozone. The redesignation request and maintenance plan meet the redesignation requirements in section 107(d)(3)(d) of the Act. The redesignation meets the Federal requirements of section 182(a)(1) of the Clean Air Act as a revision to the Illinois ozone State Implementation Plan for Jersey County.

(i) The base year (1990) ozone emission inventory requirement of section 182(a)(1) of the Clean Air Act, as amended in 1990, has been satisfied for the following Illinois ozone nonattainment areas: the Chicago nonattainment area—Cook, DuPage, Kane, Lake, Will and McHenry Counties, Aux Sable and Gooselake Townships in Grundy County, and Oswego Township in Kendall County; the Metro-East St. Louis nonattainment area—Madison, Monroe, and St. Clair Counties; and Jersey County.

(j) Approval—On July 14, 1994, Illinois submitted two of three elements required by section 182(d)(1)(A) of the Clean Air Amendments of 1990 to be incorporated as part of the vehicle miles traveled (VMT) State Implementation Plan intended to offset any growth in emissions from a growth in vehicle miles traveled. These elements are the offsetting of growth in emissions attributable to growth in VMT which was due November 15, 1992, and, transportation control measures (TCMs) required as part of Illinois' 15 percent reasonable further progress (RFP) plan which was due November 15, 1993. Illinois satisfied the first requirement by projecting emissions from mobile sources and demonstrating that no increase in emissions would take place. Illinois satisfied the second requirement by submitting the TCMs listed in Table 1 which are now approved into the Illinois SIP.

Table 1

Project type Location description Completion status SIP credit VOC tpd RS/SIG MODMadison Street (Western Ave. to Halsted Street)Done0.015400 SIG COORDWillow Road (Landwer Road to Shermer)Awarded0.052000 SIG COORDRand Road (Baldwin Road to Kennicott)Awarded0.052000 SIG COORDNorthwest Hwy (Potter Road to Cumberland Avenue)Awarded0.030000 SIGS/SIG COORD159th Street (US 45 to 76th Ave & at 91st Avenue)Awarded0.030000 SIG COORDHarlem Ave. (71st St. to 92nd)Awarded0.052000 SIG COORDHarlem Ave. (99th Street to 135th St.)Awarded0.052000 RECONST/SIGS/LTSArcher Ave. (88th Ave to 65th St.)Awarded0.030000 SIG COORDOgden Ave. (N. Aurora Road to Naper Boulevard)Awarded0.030000 SIG COORDNorth Ave. (Tyler to Kautz)Awarded0.030000 SIG COORDHiggens Road (Il 72 at Il 31)Awarded0.030000 SIG COORDSheridan Road (Il 173 to Wadsworth)Awarded0.030000 SIG COORDLagrange Road (Belmont to Lake St.)Awarded0.030000 SIG COORDDundee Road (Sanders Road to Skokie Valley Road)Awarded0.052000 SIG COORDDundee Road (Buffalo Grove Road to Il 21)Awarded0.030000 INT IMP/SIG COORDGolf Road (E. River Road to Washington Ave.)Awarded0.052000 SIG COORDGolf Road (Barrington to Roselle Road)Awarded0.030000 SIG COORDHiggins Road (Barrington to Roselle Road)Awarded0.030000 SIG COORDJoe Orr Road (Vincennes Ave. to Il 1)Awarded0.030000

Table 1

Project type Location description Completion status SIP credit SIG COORD/RSCrawford Ave. (93rd Street to 127th Street)Awarded0.052000 SIG COORDIL 53 (Briarcliff to South of I-55)Done0.030000 SIG COORDOgden Ave. (Oakwood Avenue to Fairview Avenue)Awarded0.019000 SIG COORDUS 14 (Rohlwing Road to Wilke Road)Awarded0.030000 SIG COORDUS 30 (At Cottage Grove, Ellis St)Awarded0.030000 SIG COORDIL 53 (Modonough to Mills)Done0.030000 SIG CONNOgden Ave. (IL 43 to 31st Street)Awarded0.013000 SIG CONNUS 12 (Long Grove—Hicks Road)Awarded0.055200 SIG CONNNorth Ave. (Oak Park to Ridgeland)Awarded0.007000 SIG CONNRoosevelt Road (Westchester Bl—IL 43)Awarded0.137000 SIG CONNDepster St (Keeler to Crawford Ave.)Awarded0.010000 SIG CONNArlington Hgts Rd. (Thomas to Central)Awarded0.044000 SIG CONNPalatine Rd. (Shoenbeck to Wolf Roads)Awarded0.042500 SIG CONNWestern Ave. (US 30—Lakewood)Awarded0.018900 RS/INT IMPNorth Ave. (I-290 to IL 43)Awarded0.056100 INT IMPPlum Grove Rd. (At Higgins Road)Awarded0.010700 INT IMPSt Street (At Illinois)Awarded0.002700 RS/SIG MOD/INT IMPIllinois/Grand (Kingsbury to Lake Shore Drive)Done0.004200 ADD TURN LANESYork Rd. (Industrial to Grand Ave.)Done0.003800 SERVICE IMPSW Route Lane ServiceScheduled0.005516 SIG INTCONNWashington StreetScheduled0.030370 SIG INTCONNIL 59Scheduled0.068650 ENGRCitywide—Naperville0.086230 SIG INTCONNWashington StreetScheduled0.008230 SIG INTCONNLewis Ave. (Yorkhousse to ILL 173)Scheduled0.034600 SIG INTCONNSchaumberg Rd. (Barrington to Martingale)Scheduled0.078080 Vanpool Program (94 vehicles)Region-Wide SuburbanDone0.134000 Transp. CenterNorth West Cook CountyDone0.032835 Transp. CenterSears T.F.Done0.005805 StationClark/LakeDone0.010000 Station Recon18Th Douglas LineDone0.001500 Station ReconLindenDone0.001500 Station ReconCottage GroveDone0.001300 Com. PkgLisleDone0.010177 Com. PkgJefferson ParkDone0.000110 Com. PkgEdison ParkDone0.003614 Com. PkgPalatineDone0.004336 Com. PkgCentral StreetDone0.000519 Com. PkgPalatineDone0.004890 Com. PkgCrystal LakeDone0.034948 Com. Pkg137Th/RiverdaleDone0.004565 Com. PkgRiver ForestDone0.000289 Com. Pkg115Th/KensingtonDone0.002795 Com. Pkg119Th StDone0.004483 Com. PkgWilmetteDone0.001587 Com. Pkg111Th StDone0.000507 Com. PkgEdison ParkDone0.002371 Com. PkgJolietDone0.003967 Com. PkgHanover ParkDone0.021799 Com. PkgBartlettDone0.008911 Com. PkgChicago RidgeDone0.002159 Com. Pkg103 Rd StDone0.000675 Com. PkgElmhurstDone0.003857 Com. PkgBartlettDone0.009326 Com. PkgMorton GroveDone0.001444 Com. PkgPalatineDone0.003598 Com. PkgHarvardDone0.006299 Com. PkgWillow SpringsDone0.001200 Com. PkgEdgebrookDone0.002240 Com. PkgBensenvilleDone0.002010 Com. PkgHanover ParkDone0.015020 Com. PkgMidlothianDone0.002570 Com. PkgRoute 59Done0.025020 Com. PkgLake Forest (West)Done0.013780 Com. PkgLombardDone Com. PkgElmhurstDone0.001010 Com. PkgWoodstockDone0.019000 Com. PkgUniversity ParkDone0.019950 Com. PkgGrayslakeDone0.006210 Com. PkgOak ForestDone0.004260 Com. Pkg91 St St.Done0.003380 Com. PkgLockportDone0.007360 Com. PkgRavenswoodDone0.000130 Com. PkgHickory CreekDone0.060140 Com. PkgCaryDone0.005980 Com. PkgBlue IslandDone0.019430 Com. PkgLemontDone0.016200 Com. PkgItascaDone0.003860 Com. PkgMaywoodDone0.000600 Com. PkgIvanhoeDone0.001960 Com. PkgRaviniaDone0.003210 Com. PkgFox River GroveDone0.025170 Com. PkgMedinahDone0.012250 Com. PkgHanover ParkDone0.011840 Com. PkgWorthDone0.003530 Com. PkgRoselleDone0.007710 Com. PkgCrystal LakeDone0.015050 Com. PkgGreshamDone0.000300 Com. PkgBarringtonDone0.002420 Rideshare Prog.RegionwideScheduled0.040000 Rapid Transit ServiceMidway AirportDone0.220000 Transp. CenterDeerfield Lake-CookDone0.004160 Station ReconDavis St.Done0.004000 Station ReconAddisonDone0.004000 Station ReconKing DriveDone0.003000 Station ReconWashington/WellsDone0.003000 Com. PkgCaryDone0.027910 Com. PkgMorton GroveDone0.002460 Com. Pkg80th Ave.Scheduled0.043200 Com. PkgRound LakeDone0.015150 Com. PkgGrayslakeDone0.009170 Com. PkgInglesideScheduled0.005430 Com. PkgSchamburgScheduled0.042090 Com. PkgOak ForestScheduled0.004680 Com. PkgLake CookScheduled0.026390 Com. PkgGrayslakeScheduled0.035290

(k) Approval—EPA is approving the section 182(f) oxides of nitrogen (NOX) reasonably available control technology (RACT), new source review (NSR), vehicle inspection/maintenance (I/M), and general conformity exemptions for the Illinois portion of the Chicago-Gary-Lake County severe ozone nonattainment area as requested by the States of Illinois, Indiana, Michigan, and Wisconsin in a July 13, 1994 submittal. This approval does not cover the exemption of NOX transportation conformity requirements of section 176(c) for this area. Approval of these exemptions is contingent on the results of the final ozone attainment demonstration expected to be submitted in mid-1997. The approval will be modified if the final attainment demonstration demonstrates that NOX emission controls are needed in the nonattainment area to attain the ozone standard in the Lake Michigan Ozone Study modeling domain.

(l) Approval—The United States Environmental Protection Agency is approving under section 182(b)(1) of the Clean Air Act the exemption of the Chicago severe, ozone nonattainment area from the build/no-build and less than-1990 interim transportation conformity oxides of nitrogen requirements as requested by the State of Illinois in a June 20, 1995 submittal. In light of the modeling completed thus far and considering the importance of the OTAG process and attainment plan modeling efforts, USEPA grants this NOX waiver on a contingent basis. As the OTAG modeling results and control recommendations are completed in 1996, this information will be incorporated into attainment plans being developed by the LADCO States. When these attainment plans are submitted to USEPA in mid-1997, these new modeling analyses will be reviewed to determine if the NOX waiver should be continued, altered, or removed. USEPA's rulemaking action to reconsider the initial NOX waiver may occur simultaneously with rulemaking action on the attainment plans. The USEPA also reserves the right to require NOX emission controls for transportation sources under section 110(a)(2)(D) of the Act if future ozone modeling demonstrates that such controls are needed to achieve the ozone standard in downwind areas. The Chicago severe ozone nonattainment area includes the Counties of Cook, DuPage, Grundy (Aux Sable and Gooselake Townships), Kane, Kendall (Oswego Township), Lake, McHenry, and Will.

(m) [Reserved]

(n) Negative declaration—Shipbuilding and ship repair industry. On October 11, 1996, the State of Illinois certified to the satisfaction of the United States Environmental Protection Agency that no major sources categorized as part of the shipbuilding and ship repair industry are located in the Chicago, Illinois ozone nonattainment area which is comprised of Cook, DuPage, Kane, Lake, McHenry, Will Counties and Aux Sable and Goose Lake Townships in Grundy County and Oswego Township in Kendall County or the Metro-East, Illinois ozone nonattainment area which is comprised of Madison, Monroe, and St. Clair Counties.

(o) Negative declaration—Aerospace manufacturing and rework industry. On October 11, 1996, the State of Illinois certified to the satisfaction of the United States Environmental Protection Agency that no major sources categorized as part of the Aerospace Manufacturing and Rework Industry are located in the Chicago, Illinois ozone nonattainment area which is comprised of Cook, DuPage, Kane, Lake, McHenry, Will Counties and Aux Sable and Goose Lake Townships in Grundy County and Oswego Township in Kendall County or the Metro-East, Illinois ozone nonattainment area which is comprised of Madison, Monroe, and St. Clair Counties.

(p) Approval—On November 15, 1993, Illinois submitted 15 percent rate-of-progress and 3 percent contingency plans for the Chicago ozone nonattainment area as a requested revision to the Illinois State Implementation Plan. These plans satisfy sections 182(b)(1), 172(c)(9), and 182(c)(9) of the Clean Air Act, as amended in 1990.

(q) Approval—On November 15, 1993, Illinois submitted 15 percent rate-of-progress and 3 percent contingency plans for the Metro-East St. Louis ozone nonattainment area as a requested revision to the Illinois State Implementation Plan. These plans satisfy sections 182(b)(1) and 172(c)(9) of the Clean Air Act, as amended in 1990.

(r) Approval—On November 15, 1993, Illinois submitted the following transportation control measures as part of the 15 percent rate-of-progress and 3 percent contingency plans for the Metro-East ozone nonattainment area: Work trip reductions; transit improvements; and traffic flow improvements.

(s) On October 10, 1997, Illinois submitted a site-specific revision to the State Implementation Plan, in the form of a letter from Bharat Mathur, Chief, Bureau of Air, Illinois Environmental Protection Agency. This October 10, 1997, letter requests a change in regulatory status for Riverside Laboratories, Inc.'s Kane County facility, to reflect that the Federal site-specific rule for Riverside (40 CFR 52.741(e)(10)) has been superseded by the State of Illinois regulations, including the emission limits in 35 Illinois Administrative Code 218.204(c) and the associated control requirements, test methods and recordkeeping requirements in Part 218 and the associated definitions in part 211. These State regulations shall become the federally approved regulations applicable to Riverside on August 31, 1998. The site-specific rule, applicable to Riverside, promulgated by the Environmental Protection Agency on August 21, 1995 (40 CFR 52.741(e)(10)), remains in effect and is enforceable after August 31, 1998 for the period before August 31, 1998.

(t) The Illinois volatile organic compound (VOC) rules that apply to the Stepan Company Millsdale Plant for volatile organic liquid storage (35 Ill. Admin. Code Part 218, Subpart B), batch processing (35 Ill. Admin. Code Parts 218 and 219, Subpart V) and continuous reactor and distillation processes (35 Ill. Admin. Code Part 218, Subpart Q) were approved by the United States Environmental Protection Agency (USEPA) on August 8, 1996, April 2, 1996, and June 17, 1997, respectively. Because these rules have been approved into the State Implementation Plan and represent reasonably available control technology for VOC, USEPA revokes the June 29, 1990 Federal Implementation Plan as it applies to Stepan and replaces it with Illinois' volatile organic liquid storage, batch process, and continuous reactor and distillation process rules.

(u) Negative declaration—Industrial wastewater category. On October 2, 1998, the State of Illinois certified to the satisfaction of the United States Environmental Protection Agency that no major sources categorized as part of the Industrial wastewater category are located in the Metro-East ozone nonattainment area (Metro-East). The Metro-East area is comprised of Madison, Monroe and St. Clair Counties which are located in southwest Illinois, adjacent to St. Louis, Missouri.

(v) Negative declaration—Industrial cleaning solvents category. On October 2, 1998, the State of Illinois certified to the satisfaction of the United States Environmental Protection Agency that no major sources categorized as part of the Industrial cleaning solvents category are located in the Metro-East ozone nonattainment area (Metro-East). The Metro-East area is comprised of Madison, Monroe and St. Clair Counties which are located in southwest Illinois, adjacent to St. Louis, Missouri.

(w) Approval—On December 18, 1997, December 17, 1999, January 14, 2000, and January 21, 2000, Illinois submitted a post-1996 Rate Of Progress Plan for the Chicago ozone nonattainment area as a requested revision to the Illinois State Implementation Plan. This plan reduces ozone precursor emissions by 9 percent from 1990 baseline emissions by November 15, 1999. This plan also supports a mobile source emissions budget of 279.3 tons/day of volatile organic compounds for transportation conformity purposes.

(x) Approval—On December 18, 1997, Illinois submitted a contingency measure plan as part of the Chicago Area post-1996 Rate of Progress Plan. This plan reduces volatile organic compound emissions in the Chicago ozone nonattainment area by 3 percent from 1990 baseline emissions by November 15, 1999.

(y) Approval—On December 18, 1997, Illinois submitted Transportation Control Measures (TCMs) as part of the post-1996 Rate Of Progress Plan for the Chicago ozone nonattainment area. The TCMs being approved are listed in the following documents published by the Chicago Area Transportation Study: “Transportation Control Measures Contribution to the Post-1996 Rate-Of-Progress State Implementation Plan,” March 22, 1996; “Transportation Control Measures Contribution to the 9 percent Control Strategy State Implementation Plan,” June 11, 1998; and “1999 Transportation Control Measures Contribution to the 9 percent Rate of Progress Control Strategy State Implementation Plan,” December 9, 1999.

(z) Negative declaration—Industrial cleaning solvents category. On December 23, 1999, the State of Illinois certified to the satisfaction of the United States Environmental Protection Agency that no major sources categorized as part of the industrial cleaning solvents category are located in the Chicago ozone nonattainment area. The Chicago ozone nonattainment area includes Cook County, DuPage County, Aux Sable and Goose Lake Townships in Grundy County, Kane County, Oswego Township in Kendall County, Lake County, McHenry County and Will County.

(aa) Negative declaration—Industrial wastewater category. On December 23, 1999, the State of Illinois certified to the satisfaction of the United States Environmental Protection Agency that no major sources categorized as part of the Industrial Wastewater Category are located in the Chicago ozone nonattainment area. The Chicago ozone nonattainment area includes Cook County, DuPage County, Aux Sable and Goose Lake Townships in Grundy County, Kane County, Oswego Township in Kendall County, Lake County, McHenry County and Will County.

(bb) Approval—Revisions to the SIP submitted by Illinois on November 15, 1999; February 10, 2000; April 13, 2001; and April 30, 2001. The revisions are for the purpose of satisfying the attainment demonstration requirements of section 182(c)(2)(A) of the Act for the Metro-East St. Louis area. The revision establishes an attainment date of November 15, 2004, for the St. Louis moderate ozone nonattainment area. This revision establishes MVEBs for 2004 of 26.62 TPD of VOC and 35.52 TPD of NOX to be used in transportation conformity in the Metro-East St. Louis area until revised budgets pursuant to MOBILE6 are submitted and found adequate. In the revision, Illinois commits to revise its VOC and NOX transportation conformity budgets within two years of the release of MOBILE6. No conformity determinations will be made during the second year following the release of MOBILE6 unless and until the MVEBs have been recalculated using MOBILE6 and found adequate by EPA. EPA is granting a waiver for the Metro East St. Louis area to the state of Illinois from the NOX RACT requirements of the Act and disapproving the request for a waiver from the NOX NSR and NOX general conformity requirements. EPA is finding that the Contingency Measures identified by Illinois are adequate to meet the requirements of the Act. EPA finds that the Illinois SIP meets the requirements pertaining to RACM under the Act for the Metro-East St. Louis area.

(cc) Approval—Illinois has adopted and USEPA has approved sufficient NOX emission regulations to assure that it will achieve the level of NOX emissions budgeted for the State by USEPA. USEPA has made two minor budget revisions requested by Illinois, adding a boiler owned by LTV Steel and deleting a boiler owned by the University of Illinois from the inventory of large NOX sources.

(dd) Chicago Ozone Attainment Demonstration Approval—On December 26, 2000, Illinois submitted a one-hour ozone attainment demonstration plan as a requested revision to the Illinois State Implementation Plan. This plan includes: A modeled demonstration of attainment and associated attainment year conformity emission budgets; a plan to reduce ozone precursor emissions by 3 percent per year from 2000 to 2007 (a post-1999 rate-of-progress plan), and associated conformity emission budgets; a contingency measures plan for both the ozone attainment demonstration and the post-1999 rate-of-progress plan; a commitment to conduct a Mid-Course Review of the ozone attainment demonstration by the end of 2004; a demonstration that Illinois has implemented all reasonably available control measures; and a commitment to revise motor vehicle emission budgets within two years after the U.S. Environmental Protection Agency officially releases the MOBILE6 emission factor model.

(ee) Approval of the Maintenance Plan for the Illinois Portion of the St. Louis Area—On December 30, 2002 Illinois submitted Maintenance Plan for the Illinois portion of the St. Louis Nonattainment Area. The plan includes 2014 On-Road Motor Vehicle Emission Budget of 10.13 tons per ozone season weekday of VOCs and 18.72 tons per ozone season weekday NOX to be used in transportation conformity.

(ff) Approval—On April 11, 2003, Illinois submitted a revision to the ozone attainment plan for the Chicago severe 1-hour ozone nonattainment area. This plan revised the 2005 and 2007 Motor Vehicle Emissions Budgets (MVEB) recalculated using the emissions factor model MOBILE6. The approved motor vehicle emissions budgets are 151.11 tons per day VOC for 2005 and 127.42 tons per day VOC and 280.4 tons per day NOX for 2007.

(gg) Approval—On January 30, 2007, the Illinois Environmental Protection Agency (IEPA) requested that EPA find that the Illinois portion of the Chicago-Gary-Lake County, Illinois-Indiana (IL-IN) nonattainment area, attained the revoked 1-hour ozone National Ambient Air Quality Standard (NAAQS). After review of this submission, EPA approves this finding.

(hh) Disapproval. EPA is disapproving 35 Illinois Administrative Code part 217, subpart X, Voluntary NOX Emissions Reduction Program, as a revision to the Illinois SIP.

(ii) Approval. EPA is approving a July 29, 2010, request from the State of Illinois for a waiver from the Clean Air Act requirement for Oxides of Nitrogen (NOx) Reasonably Available Control Technology (RACT) in the Illinois portions of the Chicago-Gary-Lake County, Illinois-Indiana (Cook, DuPage, Kane, Lake, McHenry, and Will Counties, and portions of Grundy (Aux Sable and Goose Lake Townships) and Kendall (Oswego Township) Counties in Illinois) and St. Louis, Missouri-Illinois (Jersey, Madison, Monroe, and St. Clair Counties in Illinois) 1997 8-hour ozone nonattainment areas.

(jj) Determination of attainment. On June 5, 2009, the state of Indiana requested that EPA find that the Indiana portion of the Chicago-Gary-Lake County, Illinois-Indiana (IL-IN) ozone nonattainment area has attained the 1997 8-hour ozone National Ambient Air Quality Standard (NAAQS). After review of Indiana's submission and 2006-2008 ozone air quality data for this ozone nonattainment area, EPA finds that the entire Chicago-Gary-Lake County, IL-IN area has attained the 1997 8-hour ozone NAAQS. Therefore, EPA has determined, as of March 12, 2010, that Cook, DuPage, Kane, Lake, McHenry, and Will Counties, and portions of Grundy County (Aux Sable and Goose Lake Townships) and Kendall County (Oswego Township) in Illinois have attained the 1997 8-hour ozone standard.

(kk) Determination of attainment. EPA has determined, as of June 9, 2011, that the St. Louis (MO-IL) metropolitan 1997 8-hour ozone nonattainment area has attained the 1997 8-hour ozone NAAQS. This determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit an attainment demonstration, associated reasonably available control measures, reasonable further progress, contingency measures, and other plan elements related to attainment of the standards for as long as the area continues to meet the 1997 Ozone NAAQS. In addition, based upon EPA's review of the air quality data for the 3-year period 2007 to 2009, the St. Louis (MO-IL) ozone nonattainment area has attained the 1997 8-hour ozone NAAQS by the applicable attainment date of June 15, 2010.

(ll) Approval—On May 26, 2010, and September 16, 2011, Illinois submitted a request to redesignate the Illinois portion of the St. Louis, MO-IL area to attainment of the 1997 8-hour ozone standard. The St. Louis area includes Jersey, Madison, Monroe, and St. Clair Counties in Illinois and St. Louis City and Franklin, Jefferson, St. Charles and St. Louis Counties in Missouri. As part of the redesignation request, the State submitted a plan for maintaining the 1997 8-hour ozone standard through 2025 in the area as required by section 175A of the Clean Air Act. Part of the section 175A maintenance plan includes a contingency plan. The ozone maintenance plan establishes 2008 motor vehicle emissions budgets for the Illinois portion of the St. Louis area of 17.27 tpd for volatile organic compounds (VOC) and 52.57 tpd for nitrogen oxides (NOX). In addition the maintenance plan establishes 2025 motor vehicle emissions budgets for the Illinois portion of the St. Louis area of 5.68 tpd for VOC and 15.22 tpd for NOX.

(mm) Emissions inventories for the 1997 8-hour ozone standard

(1) Approval—Illinois' 2002 emissions inventory satisfies the emissions inventory requirements of section 182(a)(1) of the Clean Air Act for the Illinois portion of the St. Louis, MO-IL area under the 1997 8-hour ozone standard.

(2) Approval—Illinois' 2002 volatile organic compounds and nitrogen oxides emission inventories satisfy the emissions inventory requirements of section 182(a)(1) of the Clean Air Act for the Illinois portion of the Chicago-Gary-Lake County, Illinois-Indiana area under the 1997 8-hour ozone standard.

(nn) Approval—On July 23, 2009, and September 16, 2011, Illinois submitted a request to redesignate the Illinois portion of the Chicago-Gary-Lake County, Illinois-Indiana area to attainment of the 1997 8-hour ozone standard. The Illinois portion of the Chicago-Gary-Lake County, Illinois-Indiana area includes Cook, DuPage, Kane, Lake, McHenry, and Will Counties and portions of Grundy (Aux Sable and Goose Lake Townships) and Kendall (Oswego Township) Counties. As part of the redesignation request, the State submitted a plan for maintaining the 1997 8-hour ozone standard through 2025 in the area as required by section 175A of the Clean Air Act. Part of the section 175A maintenance plan includes a contingency plan. The ozone maintenance plan establishes 2008 motor vehicle emissions budgets for the Illinois portion of the Chicago-Gary-Lake County, Illinois-Indiana area of 117.23 tons per day (tpd) for volatile organic compounds (VOC) and 373.52 tpd for nitrogen oxides (NOX). In addition, the maintenance plan establishes 2025 motor vehicle emissions budgets for the Illinois portion of the Chicago-Gary-Lake County, Illinois-Indiana area of 48.13 tpd for VOC and 125.27 tpd for NOX.

(oo) Approval—On March 28, 2014, the State of Illinois submitted a revision to its State Implementation Plan for the Illinois portion of the Chicago-Gary-Lake County, Illinois-Indiana area (the Greater Chicago Area). The submittal established new Motor Vehicle Emissions Budgets (MVEB) for Volatile Organic Compounds (VOC) and Oxides of Nitrogen (NOX) for the year 2025. The MVEBs for the Illinois portion of the Greater Chicago Area are: 60.13 tons/day of VOC emissions and 150.27 tons/day of NOX emissions for the year 2025.

(pp) On September 3, 2014, Illinois submitted 2011 volatile organic compounds and oxides of nitrogen emission inventories for the Illinois portions of the Chicago-Naperville, Illinois-Indiana-Wisconsin and St. Louis, Missouri-Illinois nonattainment areas for the 2008 ozone national ambient air quality standard as a revision of the Illinois state implementation plan. The emission inventories are approved as a revision of the state's implementation plan.

(qq) Determination of attainment. As required by section 181(b)(2)(A) of the Clean Air Act, EPA has determined that the St. Louis, MO-IL marginal 2008 ozone nonattainment area has attained the NAAQS by the applicable attainment date of July 20, 2016.

[45 FR 55197, Aug. 19, 1980] Editorial Note:For Federal Register citations affecting § 52.726, see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume and at www.govinfo.gov.

§ 52.727 - [Reserved]

§ 52.728 - Control strategy: Nitrogen dioxide. [Reserved]

§ 52.729 - [Reserved]

§ 52.730 - Compliance schedules.

(a) The requirements of § 51.262(a) of this chapter are not met since compliance schedules with adequate increments of progress have not been submitted for every source for which they are required.

(b) Federal compliance schedules. (1) Except as provided in paragraph (b)(3) of this section, the owner or operator of any stationary source subject to the following emission limiting regulations in the Illinois implementation plan shall comply with the applicable compliance schedule in paragraph (b)(2) of this section: Illinois Air Pollution Control Regulations Rule 203(d)(4), 203(d)(6)(B)(ii)(bb), 203(g)(1)(B), 203(g)(2), 203(g)(3), 203(g)(4), 204(c)(1)(A), 204(c)(2), 204(d), and 204(e).

(2) Compliance schedules. (i) The owner or operator of any stationary source subject to Illinois Air Pollution Control Regulation Rule 203(d)(4) shall take the following actions with respect to the source no later than the date specified.

(a) September 30, 1973—Advertise for bids for purchase and construction or installation of equipment, or for materials requisite for process modification sufficient to control particulate emissions from the source.

(b) November 15, 1973—Award contracts for emission control systems or process modification, or issue orders for the purchase of component parts to accomplish emission control or process modification.

(c) May 31, 1974—Initiate onsite construction or installation of emission control system or process modification.

(d) March 31, 1975—Complete onsite construction or installation of emission system or process modification.

(e) May 31, 1975—Complete shakedown operation and performance test on source, submit performance test results to the Administrator; achieve full compliance with State agency regulation.

(ii) The owner or operator of any stationary source subject to Illinois Air Pollution Control Regulation Rule 203(d)(6)(B)(ii)(bb) shall take the following actions with respect to the source no later than the date specified.

(a) September 30, 1973—Advertise for bids for purchase and construction or for modification of equipment sufficient to control particulate emissions from the source.

(b) November 15, 1973—Award contracts for emissions control systems or process modification, or issue orders for the purchase of component parts to accomplish emission control or process modification.

(c) March 31, 1974—Initiate onsite construction or installation of emission control system.

(d) October 31, 1974—Complete onsite construction or installation of emission control system.

(e) December 31, 1974—Achieve final compliance with Illinois Air Pollution Control Regulations Rule 203(d)(6)(B)(ii)(bb).

(iii) (a) The owner or operator of any boiler or furnace of more than 250 million BTU per hour heat input subject to Illinois Air Pollution Control Regulation Rule 204(c)(1)(A), 204(c)(2), 204(d), and 204(e) shall notify the Administrator, no later than October 1, 1973, of his intent to utilize either low-sulfur fuel or stack gas desulfurization to the requirements of said regulation.

(b) Any owner or operator of a stationary source subject to paragraph (b)(2)(iii)(a) of this section who elects to utilize low sulfur fuel shall take the following actions with respect to the source no later than the date specified.

(1) November 1, 1973—Submit to the Administrator a projection of the amount of fuel, by types, that will be substantially adequate to enable compliance with Illinois Air Pollution Control Regulations Rule 204(c)(1)(A), 204(c)(2), 204(d), and 204(e) on May 31, 1975, and for at least one year thereafter.

(2) December 31, 1973—Sign contracts with fuel suppliers for fuel requirements as projected above.

(3) January 31, 1974—Submit a statement as to whether boiler modifications will be required. If modifications will be required, submit plans for such modifications.

(4) March 15, 1974—Let contracts for necessary boiler modifications, if applicable.

(5) June 15, 1974—Initiate onsite modifications, if applicable.

(6) March 31, 1975—Complete onsite modifications, if applicable.

(7) May 31, 1975—Final compliance with the emission limitation of Rules 204(c)(1)(A), 204(c)(2), 204(d), and 204(e).

(c) Any owner or operator of a fuel combustion source subject to paragraph (b)(2)(iii)(a) of this section who elects to utilize stack gas desulfurization shall take the following actions with respect to the source no later than the date specified.

(1) November 1, 1973—Let necessary contracts for construction.

(2) March 31, 1974—Initiate onsite construction.

(3) March 31, 1975—Complete onsite construction.

(4) May 31, 1975—Complete shakedown operations and performance test on source, submit performance test results to the Administrator; achieve full compliance with Rule 204(c)(1)(A), 204(c)(2), 204(d), and 204(e).

(iv) (a) The owner or operator of any stationary source subject to Illinois Air Pollution Control Regulations Rule 203(g)(1)(B), 203(g)(2), 203(g)(3), and 203(g)(4) shall notify the Administrator, no later than October 1, 1973, of his intent to utilize either low ash fuel or a stack gas cleaning system to meet the requirements of said regulation.

(b) Any owner or operator of a stationary source subject to paragraph (b)(2)(iv)(a) of this section who elects to utilize low ash fuel shall take the following actions with respect to the source no later than the date specified.

(1) November 1, 1973—Submit to the Administrator a projection of the amount of fuel, by types, that will be substantially adequate to enable compliance with Illinois Air Pollution Control Regulations Rule 203(g)(1)(B), 203(g)(2), 203(g)(3), and 203(g)(4) on May 31, 1975, and for at least one year thereafter.

(2) December 31, 1973—Sign contracts with fuel suppliers for fuel requirements as projected above.

(3) January 31, 1974—Submit a statement as to whether boiler modifications will be required. If modifications will be required, submit plans for such modifications.

(4) March 15, 1974—Let contracts for necessary boiler modifications, if applicable.

(5) June 15, 1974—Initiate onsite modifications, if applicable.

(6) March 31, 1975—Complete onsite modifications, if applicable.

(7) May 31, 1975—Final compliance with the emission limitation of Rule 203(g)(1)(B), 203(g)(2), 203(g)(3), and 203(g)(4).

(c) Any owner or operator of a stationary source subject to paragraph (b)(2)(iv)(a) of this section who elects to utilize a stack gas cleaning system shall take the following actions with respect to the source no later than the date specified.

(1) January 15, 1974—Let necessary contracts for construction.

(2) April 1, 1974—Initiate onsite construction.

(3) April 1, 1975—Complete onsite construction.

(4) May 31, 1975—Complete shakedown operations and performance tests on source, submit performance test results to the Administrator; achieve full compliance with Rule 203(g)(1)(B), 203(g)(2), 203(g)(3), and 203(g)(4).

(v) Ten days prior to the conduct of any performance test required by this paragraph, the owner or operator of the affected source shall give notice of such test to the Administrator to afford him the opportunity to have an observer present.

(vi) Any owner or operator subject to a compliance schedule above shall certify to the Administrator, within five days after the deadline for each increment of progress in that schedule, whether or not the increment has been met.

(3)(i) None of the above paragraphs shall apply to a source which is presently in compliance with applicable regulations and which has certified such compliance to the Administrator by October 1, 1973. The Administrator may request whatever supporting information he considers necessary for proper certification.

(ii) Any compliance schedule adopted by the State and approved by the Administrator shall satisfy the requirements of this paragraph for the affected source.

(iii) Any owner or operator subject to a compliance schedule in this paragraph may submit to the Administrator no later than October 1, 1973, a proposed alternative compliance schedule. No such compliance schedule may provide for final compliance after the final compliance date in the applicable compliance schedule of this paragraph. If promulgated by the Administrator, such schedule shall satisfy the requirements of this paragraph for the affected source.

(4) Nothing in this paragraph shall preclude the Administrator from promulgating a separate schedule for any source to which the application of the compliance schedules in paragraph (b)(2) of this section fail to satisfy the requirements of §§ 51.261 and 51.262(a) of this chapter.

(c) [Reserved]

(d) The compliance schedules for the sources identified below are disapproved as not meeting the requirements of subpart N of this chapter. All regulations cited are air pollution control regulations of the State, unless otherwise noted.

Source Location Regulation involved Date schedule adopted christian countyAllied Mills, IncTaylorville204(c)Feb. 28, 1973. cook countyHarco Aluminum IncChicago204(c)Dec. 9, 1973. J. L. Clark Manufacturing CoDowners Grove205(f)May 4, 1973. Johnson & JohnsonBedford Park205(f)Jun. 20, 1973. Lloyd J. Harris Pie, Co. IncChicago204(c)Feb. 27, 1973. Union Oil Co. of California
(a) No. 10 boiler
......do204(c)Jun. 19, 1973,
Dec. 13, 1973.
(b) 11BIA crude heater W. H. Hutchingson & Son, Inc......do205(f)Aug. 12, 1973. Western Rust Proof Co......do204(c)Oct. 10, 1973. Wheeler Uniform Service Inc......do204(c)May 22, 1973. Wm. Yuenger Manufacturing Co......do204(c)Aug. 16, 1973. World's Finest Chocolate Inc......do204(c)May 30, 1973. jackson countyTuck Industries, IncCarbondale204(c)Jun. 20, 1973. kane countyAll Steel Equipment CorpMontgomery204(f)July 24, 1973. Consolidated Food IncAurora205(f)May 9, 1973. lake countyMorton Manufacturing CoLibertyville205(f)Aug. 27, 1973. la salle countyAllied Mills IncMendota204(c)May 28, 1973. madison countyClark Oil & Refining CorpHartford204(f)Feb. 22, 1973. Granite City Steel CoGranite City203(d)(6)Apr. 25, 1972. (a) Coke oven pushing operationsas amended. (b) Charging operationsMay 21, 1973. Illinois Power Company (Wood River Boiler No. 5)E. Alton204(c)May 1, 1973. Owens-Illinois IncMadison204(c)May 2, 1973. Owen-Illinois Inc. (No. 2 Powerhouse)Alton204(c)Mar. 30, 1973. Shell Oil Co. (Cat. Cracker Units Nos. 1, 2)Roxana203(b)Nov. 27, 1972. randolf countyChester Dairy CoChester204(c)Aug. 6, 1973. st. clair countyLock Stove CoEast St. Louis205(b)June 11, 1973. tazewell countyQuaker Oats CoPekin204(c)May 24, 1973. vermillion countyLauhoff Grain CoDanville204(c)Mar. 31, 1973.
[38 FR 16145, June 20, 1973, as amended at 38 FR 22742, Aug. 23, 1973; 38 FR 24342, Sept. 7, 1973; 39 FR 28155, Aug. 5, 1974; 51 FR 40675, 40676, 40677, Nov. 7, 1986; 54 FR 25258, June 14, 1989]

§ 52.731 - Interstate pollutant transport provisions; What are the FIP requirements for decreases in emissions of nitrogen oxides?

(a)(1) The owner and operator of each source and each unit located in the State of Illinois and for which requirements are set forth under the CSAPR NOX Annual Trading Program in subpart AAAAA of part 97 of this chapter must comply with such requirements. The obligation to comply with such requirements will be eliminated by the promulgation of an approval by the Administrator of a revision to Illinois' State Implementation Plan (SIP) as correcting the SIP's deficiency that is the basis for the CSAPR Federal Implementation Plan under § 52.38(a), except to the extent the Administrator's approval is partial or conditional.

(2) Notwithstanding the provisions of paragraph (a)(1) of this section, if, at the time of the approval of Illinois' SIP revision described in paragraph (a)(1) of this section, the Administrator has already started recording any allocations of CSAPR NOX Annual allowances under subpart AAAAA of part 97 of this chapter to units in the State for a control period in any year, the provisions of subpart AAAAA of part 97 of this chapter authorizing the Administrator to complete the allocation and recordation of CSAPR NOX Annual allowances to units in the State for each such control period shall continue to apply, unless provided otherwise by such approval of the State's SIP revision.

(b)(1) The owner and operator of each source and each unit located in the State of Illinois and for which requirements are set forth under the CSAPR NOX Ozone Season Group 1 Trading Program in subpart BBBBB of part 97 of this chapter must comply with such requirements with regard to emissions occurring in 2015 and 2016.

(2) The owner and operator of each source and each unit located in the State of Illinois and for which requirements are set forth under the CSAPR NOX Ozone Season Group 2 Trading Program in subpart EEEEE of part 97 of this chapter must comply with such requirements with regard to emissions occurring in 2017 through 2020.

(3) The owner and operator of each source and each unit located in the State of Illinois and for which requirements are set forth under the CSAPR NOX Ozone Season Group 3 Trading Program in subpart GGGGG of part 97 of this chapter must comply with such requirements with regard to emissions occurring in 2021 and each subsequent year. The obligation to comply with such requirements will be eliminated by the promulgation of an approval by the Administrator of a revision to Illinois' State Implementation Plan (SIP) as correcting the SIP's deficiency that is the basis for the CSAPR Federal Implementation Plan (FIP) under § 52.38(b)(1) and (b)(2)(iii), except to the extent the Administrator's approval is partial or conditional.

(4) Notwithstanding the provisions of paragraph (b)(3) of this section, if, at the time of the approval of Illinois' SIP revision described in paragraph (b)(3) of this section, the Administrator has already started recording any allocations of CSAPR NOX Ozone Season Group 3 allowances under subpart GGGGG of part 97 of this chapter to units in the State for a control period in any year, the provisions of subpart GGGGG of part 97 of this chapter authorizing the Administrator to complete the allocation and recordation of CSAPR NOX Ozone Season Group 3 allowances to units in the State for each such control period shall continue to apply, unless provided otherwise by such approval of the State's SIP revision.

(5) Notwithstanding the provisions of paragraph (b)(2) of this section, after 2020 the provisions of § 97.826(c) of this chapter (concerning the transfer of CSAPR NOX Ozone Season Group 2 allowances between certain accounts under common control), the provisions of § 97.826(d) of this chapter (concerning the conversion of amounts of unused CSAPR NOX Ozone Season Group 2 allowances allocated for control periods before 2021 to different amounts of CSAPR NOX Ozone Season Group 3 allowances), and the provisions of § 97.811(d) of this chapter (concerning the recall of CSAPR NOX Ozone Season Group 2 allowances equivalent in quantity and usability to all such allowances allocated to units in the State for control periods after 2020) shall continue to apply.

(c) The owner and operator of each source located in the State of Illinois and for which requirements are set forth in § 52.40 and § 52.41, § 52.42, § 52.43, § 52.44, § 52.45, or § 52.46 must comply with such requirements with regard to emissions occurring in 2026 and each subsequent year.

[77 FR 75384, Dec. 20, 2012, as amended at 81 FR 74586 and 74594, Oct. 26, 2016; 83 FR 65924, Dec. 21, 2018; 86 FR 23174, Apr. 30, 2021; 88 FR 36890, June 5, 2023]

§ 52.732 - Interstate pollutant transport provisions; What are the FIP requirements for decreases in emissions of sulfur dioxide?

(a) The owner and operator of each source and each unit located in the State of Illinois and for which requirements are set forth under the CSAPR SO2 Group 1 Trading Program in subpart CCCCC of part 97 of this chapter must comply with such requirements. The obligation to comply with such requirements will be eliminated by the promulgation of an approval by the Administrator of a revision to Illinois' State Implementation Plan (SIP) as correcting the SIP's deficiency that is the basis for the CSAPR Federal Implementation Plan under § 52.39, except to the extent the Administrator's approval is partial or conditional.

(b) Notwithstanding the provisions of paragraph (a) of this section, if, at the time of the approval of Illinois' SIP revision described in paragraph (a) of this section, the Administrator has already started recording any allocations of CSAPR SO2 Group 1 allowances under subpart CCCCC of part 97 of this chapter to units in the State for a control period in any year, the provisions of subpart CCCCC of part 97 of this chapter authorizing the Administrator to complete the allocation and recordation of CSAPR SO2 Group 1 allowances to units in the State for each such control period shall continue to apply, unless provided otherwise by such approval of the State's SIP revision.

[76 FR 48364, Aug. 8, 2011. Redesignated at 77 FR 10334, Feb. 21, 2012, as amended at 81 FR 74586, Oct. 26, 2016]

§§ 52.733-52.735 - §[Reserved]

§ 52.736 - Review of new sources and modifications.

(a) [Reserved]

(b) The rules submitted by the State on March 24, 1988, to satisfy the requirements of the Clean Air Act are approved. These rules are part 203: Major Stationary Sources Construction and Modification as effective March 22, 1991. The moratorium on construction and modification of new sources in nonattainment areas as provided in section 110(a)(2)(I) of the Clean Air Act is revoked.

[57 FR 59935, Dec. 17, 1992]

§ 52.737 - Operating permits.

Emission limitation and other provisions contained in operating permits issued by the State in accordance with the provisions of the federally approved permit program shall be the applicable requirements of the federally approved Illinois SIP for the purpose of section 113 of the Clean Air Act and shall be enforceable by USEPA and by any person in the same manner as other requirements of the SIP. USEPA reserves the right to deem an operating permit not federally enforceable. Such a determination will be made according to appropriate procedures, and be based upon the permit, permit approval procedures or permit requirements which do not conform with the operating permit program requirements or the requirements of USEPA's underlying regulations.

[57 FR 59936, Dec. 17, 1992]

§ 52.738 - Significant deterioration of air quality.

(a) The requirements of sections 160 through 165 of the Clean Air Act are met, except for sources seeking permits to locate in Indian reservations within the State of Illinois, and any other area where the EPA or an Indian tribe has demonstrated that a tribe has jurisdiction.

(b) The provisions of § 52.21 except paragraph (a)(1) are hereby incorporated and made a part of the applicable State plan for the State of Illinois for sources seeking permits to locate in Indian reservations or in any other area where the EPA or an Indian tribe has demonstrated that a tribe has jurisdiction.

(c) All applications and other information required pursuant to § 52.21 from sources located in the State of Illinois shall be submitted to the state agency, Illinois Environmental Protection Agency, 1021 North Grand Avenue East, Springfield, Illinois 62794.

[45 FR 52741, Aug. 7, 1980, as amended at 46 FR 9584, Jan. 29, 1981; 68 FR 11323, Mar. 10, 2003; 68 FR 74489, Dec. 24, 2003; 75 FR 55275, Sept. 10, 2010; 86 FR 50470, Sept. 9, 2021]

§ 52.739 - Permit fees.

(a) The requirements of section 110(a)(2)(K) of the Clean Air Act as amended in 1977 are not met since the state has not submitted to EPA, as a part of its State Implementation Plan, provisions for a permit fee system.

[46 FR 23237, Apr. 24, 1981]

§ 52.740 - Interstate pollution.

(a) The requirements of section 126(a)(2) of the Clean Air Act as amended in 1977 are not met since the state has not submitted to EPA, as a part of its State Implementation Plan, the procedures on which the state is relying to notify nearby states of any proposed major stationary source which may significantly contribute to levels of air pollution in excess of the National Ambient Air Quality Standards in that state.

[46 FR 23237, Apr. 24, 1981]

§ 52.741 - Control strategy: Ozone control measures for Cook, DuPage, Kane, Lake, McHenry and Will Counties.

(a) General Provisions—(1) Abbreviations and conversion factors. (i) The following abbreviations are used in § 52.741:

ASTM American Society for Testing and Materials bbl barrels (42 gallons) °C degrees Celsius or centigrade cm centimeters cu in. cubic inches °F degrees Fahrenheit FIP Federal implementation plan ft feet ft 2 square feet g grams gpm gallons per minute g/mole grams per mole gal gallons hr hours in inches K degrees Kelvin kcal kilocalories kg kilograms kg/hr kilograms per hour kPa kilopascals; one thousand newtons per square meter l liters l/sec liters per second lbs pounds lbs/hr pounds per hour lbs/gal pounds per gallon LEL lower explosive limit m meters m 2 square meters m 3 cubmic meters mg milligrams Mg Megagrams, metric tons or tonnes ml milliliters min minutes MJ megajoules mm Hg millimeters of mercury ppm parts per million ppmv parts per million by volume psi pounds per square inch psia pounds per square inch absolute psig pounds per square inch gauge scf standard cubic feet scm standard cubic meters sec seconds SIP State implementation plan sq cm square centimeters sq in square inches USEPA United States Environmental Protection Agency VOC volatile organic compounds VOL volatile organic liquids VOM volatile organic materials

(ii) The following conversion factors are used in § 52.741.

English Metric 1 gal3.785 l. 1,000 gal3,785 l or 3.785 m 3. 1 psia6.897 kPa (51.71 mm Hg). 2.205 lbs1 kg. 1 bbl159.0 l. 1 cu in16.39 ml. 1 lb/gal119,800 mg/l. 1 ton0.907 Mg.

(2) Applicability. (i) Any source that received a stay, as indicated in § 218.103(a)(2), remains subject to the stay if still in effect, or (if the stay is no longer in effect) the federally-promulgated or federally-approved rule applicable to such source.

(ii)(A) Effective November 20, 1996 Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, and Part 218: Organic Material Emission Standards and Limitations for the Chicago Area replace the requirements of 40 Cspan 52.741 Control strategy: Ozone control measures for Cook, DuPage, Kane, Lake, McHenry and Will County as the federally enforceable control measures in these counties for the major non-Control Technique Guideline (CTG) sources in the Chicago area, previously subject to paragraph u, v, w, or x because of the applicability criteria in these paragraphs.

(B) In accordance with § 218.101(b), for the major non-CTG sources subject to paragraphs u, v, w, or x because of the applicability criteria of those paragraphs, the requirements of paragraphs u, v, w, and x, and the recordkeeping requirements in paragraph y and any related parts of § 52.741 necessary to implement these paragraphs (including, but not limited to, those paragraphs containing test methods and definitions), shall remain in effect and are enforceable after November 20, 1996 for the period from July 30, 1990 until November 20, 1996.

(iii)(A) Except as provided in paragraphs (a)(2) (i) and (ii) of this section, effective October 11, 1994, Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, and Part 218: Organic Material Emission Standards and Limitations for the Chicago Area replace the requirements of this § 52.741 Control strategy: Ozone control measures for Cook, DuPage, Kane, Lake, McHenry and Will County as the federally enforceable control measures in these counties.

(B) In accordance with § 218.101(b), the requirements of § 52.741 shall remain in effect and are enforceable after October 11, 1994, for the period from July 30, 1990, to October 11, 1994.

(3) Definitions. The following terms are defined for the purpose of § 52.741.

Note:

The Federal definitions supersede the State definitions for these terms, which were previously approved by USEPA as part of the SIP. The federally approved definitions for all other terms remain in effect and applicable to these Federal rules.

Accelacota means a pharmaceutical coating operation which consists of a horizontally rotating perforated drum in which tablets are placed, a coating is applied by spraying, and the coating is dried by the flow of air across the drum through the perforations.

Accumulator means the reservoir of a condensing unit receiving the condensate from a surface condenser.

Actual emissions means the actual quantity of VOM emissions from an emission source during a particular time period.

Adhesive means any substance or mixture of substances intended to serve as a joining compound.

Administrator means the Administrator of the USEPA or that person's designee.

Afterburner means a control device in which materials in gaseous effluent are combusted.

Air contaminant means any solid, liquid, or gaseous matter, any odor, or any form of energy, that is capable of being released into the atmosphere from an emission source.

Air dried coatings means any coatings that dry by use of air or forced air at temperatures up to 363.15 K (194 °F).

Air pollution means the presence in the atmosphere of one or more air contaminants in sufficient quantities and of such characteristics and duration as to be injurious to human, plant, or animal life, to health, or to property, or to unreasonably interfere with the enjoyment of life or property.

Air pollution control equipment means any equipment or facility of a type intended to eliminate, prevent, reduce or control the emission of specified air contaminants to the atmosphere.

Air suspension coater/dryer means a pharmaceutical coating operation which consists of vertical chambers in which tablets or particles are placed, and a coating is applied and then dried while the tablets or particles are kept in a fluidized state by the passage of air upward through the chambers.

Air-assisted airless spray means a spray coating method which combines compressed air with hydraulic pressure to atomize the coating material into finer droplets than is achieved with pure airless spray. Lower hydraulic pressure is used than with airless spray.

Airless spray means a spray coating method in which the coating is atomized by forcing it through a small opening at high pressure. The coating liquid is not mixed with air before exiting from the nozzle.

Allowable emissions means the quantity of VOM emissions during a particular time period from a stationary source calculated using the maximum rated capacity of the source (unless restricted by federally enforceable limitations on operating rate, hours of operation, or both) and the most stringent of:

(A) The applicable standards in 40 Cspan parts 60 and 61:

(B) The applicable implementation plan; or

(C) A federally enforceable permit.

Ambient air quality standards means those standards designed to protect the public health and welfare codified in 40 Cspan part 50 and promulgated from time to time by the USEPA pursuant to authority contained in Section 108 of the Clean Air Act, 42 U.S.C. 7401 et seq., as amended from time to time.

Applicator means a device used in a coating line to apply coating.

As applied means the exact formulation of a coating during application on or impregnation into a substrate.

Asphalt means the dark-brown to black cementitious material (solid, semisolid, or liquid in consistency) of which the main constituents are bitumens which occur naturally or as a residue of petroleum refining.

Automobile means a motor vehicle capable of carrying no more than 12 passengers.

Automobile or light-duty truck assembly plant means a facility where parts are assembled or finished for eventual inclusion into a finished automobile or light-duty truck ready for sale to vehicle dealers, but not including customizers, body shops, and other repainters.

Automobile or light-duty truck refinishing means the repainting of used automobiles and light-duty trucks.

Baked coatings means any coating which is cured or dried in an oven where the oven air temperature exceeds 90 °C (194 °F).

Binders means organic materials and resins which do not contain VOM's.

Bituminous coatings means black or brownish coating materials which are soluble in carbon disulfide, which consist mainly of hydrocarbons, and which are obtained from natural deposits or as residues from the distillation of crude oils or of low grades of coal.

Brush or wipe coating means a manual method of applying a coating using a brush, cloth, or similar object.

Bulk gasoline plant means a gasoline storage and distribution facility with an average throughput of 76,000 l (20,000 gal) or less on a 30-day rolling average that distributes gasoline to gasoline dispensing facilities.

Can means any metal container, with or without a top, cover, spout or handles, into which solid or liquid materials are packaged.

Can coating means any coating applied on a single walled container that is manufactured from metal sheets thinner than 29 gauge (0.0141 in.).

Can coating facility means a facility that includes one or more can coating line(s).

Can coating line means a coating line in which any protective, decorative, or functional coating is applied onto the surface of cans or can components.

Capture means the containment or recovery of emissions from a process for direction into a duct which may be exhausted through a stack or sent to a control device. The overall abatement of emissions from a process with an add-on control device is a function both of the capture efficiency and of the control device.

Capture device means a hood, enclosed room floor sweep or other means of collecting solvent or other pollutants into a duct. The pollutant can then be directed to a pollution control device such as an afterburner or carbon adsorber. Sometimes the term is used loosely to include the control device.

Capture efficiency means the fraction of all VOM generated by a process that are directed to an abatement or recovery device.

Capture system means all equipment (including, but not limited to, hoods, ducts, fans, ovens, dryers, etc.) used to contain, collect and transport an air pollutant to a control device.

Clean Air Act means the Clean Air Act of 1963, as amended, including the Clean Air Act Amendments of 1977, (42 U.S.C. 7401 et seq.).

Clear coating means coatings that lack color and opacity or are transparent using the undercoat as a reflectant base or undertone color.

Clear topcoat means the final coating which contains binders, but not opaque pigments, and is specifically formulated to form a transparent or translucent solid protective film.

Closed vent system means a system that is not open to the atmosphere and is composed of piping, connections, and, if necessary, flow inducing devices that transport gas or vapor from an emission source to a control device.

Coating means a material applied onto or impregnated into a substrate for protective, decorative, or functional purposes. Such materials include, but are not limited to, paints, varnishes, sealers, adhesives, thinners, diluents, and inks.

Coating applicator means equipment used to apply a coating.

Coating line means an operation consisting of a series of one or more coating applicators and any associated flash-off areas, drying areas, and ovens wherein a surface coating is applied, dried, or cured. (It is not necessary for an operation to have an oven, or flash-off area, or drying area to be included in this definition.)

Coating plant means any plant that contains one or more coating line(s).

Coil means any flat metal sheet or strip that is rolled or wound in concentric rings.

Coil coating means any coating applied on any flat metal sheet or strip that comes in rolls or coils.

Coil coating facility means a facility that includes one or more coil coating line(s).

Coil coating line means a coating line in which any protective, decorative or functional coating is applied onto the surface of flat metal sheets, strips, rolls, or coils for industrial or commercial use.

Cold cleaning means the process of cleaning and removing soils from surfaces by spraying, brushing, flushing, or immersion while maintaining the organic solvent below its boiling point. Wipe cleaning is not included in this definition.

Component means, with respect to synthetic organic chemical and polymer manufacturing equipment, and petroleum refining and related industries, any piece of equipment which has the potential to leak VOM including, but not limited to, pump seals, compressor seals, seal oil degassing vents, pipeline valves, pressure relief devices, process drains, and open ended pipes. This definition excludes valves which are not externally regulated, flanges, and equipment in heavy liquid service. For purposes of paragraph (i) of this section, this definition also excludes bleed ports of gear pumps in polymer service.

Concrete curing compounds means any coating applied to freshly poured concrete to retard the evaporation of water.

Condensate means volatile organic liquid separated from its associated gases, which condenses due to changes in the temperature or pressure and remains liquid at standard conditions.

Continuous process means, with respect to polystyrene resin, a method of manufacture in which the styrene raw material is delivered on a continuous basis to the reactor in which the styrene is polymerized to polystyrene.

Control device means equipment (such as an afterburner or adsorber) used to remove or prevent the emission of air pollutants from a contaminated exhaust stream.

Control device efficiency means the ratio of pollution prevented by a control device and the pollution introduced to the control device, expressed as a percentage.

Conveyorized degreasing means the continuous process of cleaning and removing soils from surfaces utilizing either cold or vaporized solvents.

Crude oil means a naturally occurring mixture which consists of hydrocarbons and sulfur, nitrogen, or oxygen derivatives of hydrocarbons and which is a liquid at standard conditions.

Crude oil gathering means the transportation of crude oil or condensate after custody transfer between a production facility and a reception point.

Custody transfer means the transfer of produced petroleum and/or condensate after processing and/or treating in the producing operations, from storage tanks or automatic transfer facilities to pipelines or any other forms of transportation.

Daily-weighted average VOM content means the average VOM content of two or more coatings as applied on a coating line during any day, taking into account the fraction of total coating volume that each coating represents, as calculated with the following equation:

Where: VOMw = The average VOM content of two or more coatings as applied each day on a coating line in units of kg VOM/l (lbs VOM/gal) of coating (minus water and any compounds which are specifically exempted from the definition of VOM), n = The number of different coatings as applied each day on a coating line, Vi = The volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on a coating line in units of l (gal). Ci = The VOM content of each coating as applied each day on a coating line in units of kg VOM/l (lbs VOM/gal) of coating (minus water and any compounds which are specifically exempted from the definition of VOM), and VT = The total volume of all coatings (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on a coating line in units of l (gal).

Day means the consecutive 24 hours beginning at 12 a.m. (midnight) local time.

Degreaser means any equipment or system used in solvent cleaning.

Delivery vessel means any tank truck or trailer equipped with a storage tank that is used for the transport of gasoline to a stationary storage tank at a gasoline dispensing facility, bulk gasoline plant, or bulk gasoline terminal.

Dip coating means a method of applying coatings in which the part is submerged in a tank filled with the coating.

Drum means any cylindrical metal shipping container of 13- to 110-gallon capacity.

Electrostatic bell or disc spray means an electrostatic spray coating method in which a rapidly-spinning bell- or disc-shaped applicator is used to create a fine mist and apply the coating with high transfer efficiency.

Electrostatic spray means a spray coating method in which opposite electrical charges are applied to the substrate and the coating. The coating is attracted to the object due to the electrostatic potential between them.

Emission source and source mean any facility from which VOM is emitted or capable of being emitted into the atmosphere.

Enamel means a coating that cures by chemical cross-linking of its base resin. Enamels can be distinguished from lacquers because enamels are not readily resoluble in their original solvent.

Enclose means to cover any VOL surface that is exposed to the atmosphere.

End sealing compound coat means a compound applied to can ends which functions as a gasket when the end is assembled onto the can.

Excessive release means a discharge of more than 295 g (0.65 lbs) of mercaptans and/or hydrogen sulfide into the atmosphere in any 5-minute period.

Exterior base coat means a coating applied to the exterior of a can body, or flat sheet to provide protection to the metal or to provide background for any lithographic or printing operation.

Exterior end coat means a coating applied to the exterior end of a can to provide protection to the metal.

External-floating roof means a cover over an open top storage tank consisting of a double deck or pontoon single deck which rests upon and is supported by the volatile organic liquid being contained and is equipped with a closure seal or seals to close the space between the roof edge and tank shell.

Extreme environmental conditions means exposure to any or all of the following: ambient weather conditions; temperatures consistently above 95 °C (203 °F); detergents; abrasive and scouring agents; solvents; or corrosive atmospheres.

Extreme performance coating means any coating which during intended use is exposed to extreme environmental conditions.

Fabric coating means any coating applied on textile fabric. Fabric coating includes the application of coatings by impregnation.

Fabric coating facility means a facility that includes one or more fabric coating lines.

Fabric coating line means a coating line in which any protective, decorative, or functional coating or reinforcing material is applied on or impregnated into a textile fabric.

Federally enforceable means all limitations and conditions which are enforceable by the Administrator including those requirements developed pursuant to 40 Cspan parts 60 and 61; requirements within any applicable implementation plan; and any permit requirements established pursuant to 40 Cspan 52.21 or under regulations approved pursuant to 40 Cspan part 51 subpart I and 40 Cspan 51.166.

Final repair coat means the repainting of any topcoat which is damaged during vehicle assembly.

Firebox means the chamber or compartment of a boiler or furnace in which materials are burned, but not the combustion chamber or afterburner of an incinerator.

Fixed-roof tank means a cylindrical shell with a permanently affixed roof.

Flexographic printing means the application of words, designs, and pictures to a substrate by means of a roll printing technique in which the pattern to be applied is raised above the printing roll and the image carrier is made of elastomeric materials.

Flexographic printing line means a printing line in which each roll printer uses a roll with raised areas for applying an image such as words, designs, or pictures to a substrate. The image carrier on the roll is made of rubber or other elastome

Floating roof means a roof on a stationary tank, reservoir, or other container which moves vertically upon change in volume of the stored material.

Fountain solution means the solution which is applied to the image plate to maintain hydrophilic properties of the non-image areas.

Fuel combustion emission source means any furnace, boiler, or similar equipment used for the primary purpose of producing heat or power by indirect heat transfer.

Fuel gas system means a system for collection of refinery fuel gas including, but not limited to, piping for collecting tail gas from various process units, mixing drums and controls, and distribution piping.

Gas/gas method means either of two methods for determining capture which rely only on gas phase measurements. The first method requires construction of a temporary total enclosure (TTE) to ensure that all would-be fugitive emissions are measured. The second method uses the building or room which houses the facility as an enclosure. The second method requires that all other VOM sources within the room be shut down while the test is performed, but all fans and blowers within the room must be operated according to normal procedures.

Gas service means that the component contains process fluid that is in the gaseous state at operating conditions.

Gasoline means any petroleum distillate or petroleum distillate/alcohol blend having a Reid vapor pressure of 27.6 kPa or greater which is used as a fuel for internal combustion engines.

Gasoline dispensing facility means any site where gasoline is transferred from a stationary storage tank to a motor vehicle gasoline tank used to provide fuel to the engine of that motor vehicle.

Gross vehicle weight means the manufacturer's gross weight rating for the individual vehicle.

Gross vehicle weight rating means the value specified by the manufacturer as the maximum design loaded weight of a single vehicle.

Heated airless spray means an airless spray coating method in which the coating is heated just prior to application.

Heatset means a class of web-offset lithography which requires a heated dryer to solidify the printing inks.

Heatset-web-offset lithographic printing line means a lithographic printing line in which a blanket cylinder is used to transfer ink from a plate cylinder to a substrate continuously fed from a roll or an extension process and an oven is used to solidify the printing inks.

Heavy liquid means liquid with a true vapor pressure of less than 0.3 kPa (0.04 psi) at 294.3 K (70 °F) established in a standard reference text or as determined by ASTM method D2879-86 (incorporated by reference as specified in 40 Cspan 52.742); or which has 0.1 Reid Vapor Pressure as determined by ASTM method D323-82 (incorporated by reference as specified in 40 Cspan 52.742); or which when distilled requires a temperature of 421.95 K (300 °F) or greater to recover 10 percent of the liquid as determined by ASTM method D86-82 (incorporated by reference as specified in 40 Cspan 52.742).

Heavy off-highway vehicle products means, for the purpose of paragraph (e) of this section, heavy construction, mining, farming, or material handling equipment; heavy industrial engines; diesel-electric locomotives and associated power generation equipment; and the components of such equipment or engines.

Heavy off-highway vehicle products coating facility means a facility that includes one or more heavy off-highway vehicle products coating line(s).

Heavy off-highway vehicle products coating line means a coating line in which any protective, decorative, or functional coating is applied onto the surface of heavy off-highway vehicle products.

High temperature aluminum coating means a coating that is certified to withstand a temperature of 537.8 °C (1000 °F) for 24 hours.

Hood means a partial enclosure or canopy for capturing and exhausting, by means of a draft, the organic vapors or other fumes rising from a coating process or other source.

Hood capture efficiency means the emissions from a process which are captured by the hood and directed into a control device, expressed as a percentage of all emissions.

Hot well means the reservoir of a condensing unit receiving the condensate from a barometric condenser.

Hour means a block period of 60 minutes (e.g., 1 a.m. to 2 a.m.).

In vacuum service means, for the purpose of paragraph (i) of this section, equipment which is operating at an internal pressure that is at least 5 kPa (0.73 psia) below ambient pressure.

In-process tank means a container used for mixing, blending, heating, reacting, holding, crystallizing, evaporating or cleaning operations in the manufacture of pharmaceuticals.

Incinerator means a combustion apparatus in which refuse is burned.

Indirect heat transfer means transfer of heat in such a way that the source of heat does not come into direct contact with process materials.

Ink means a coating used in printing, impressing, or transferring an image onto a substrate.

Interior body spray coat means a coating applied by spray to the interior of a can body.

Internal-floating roof means a cover or roof in a fixed-roof tank which rests upon and is supported by the volatile organic liquid being contained and is equipped with a closure seal or seals to close the space between the roof edge and tank shell.

Lacquers means any clear wood finishes formulated with nitrocellulose or synthetic resins to dry by evaporation without chemical reaction, including clear lacquer sanding sealers.

Large appliance means any residential and commercial washers, dryers, ranges, refrigerators, freezers, water heaters, dish washers, trash compactors, air conditioners, and other similar products.

Large appliance coating means any coating applied to the component metal parts (including, but not limited to, doors, cases, lids, panels, and interior support parts) of residential and commercial washers, dryers, ranges, refrigerators, freezers, water heaters, dish washers, trash compactors, air conditioners, and other similar products.

Large appliance coating facility means a facility that includes one or more large appliance coating line(s).

Large appliance coating line means a coating line in which any protective, decorative, or functional coating is applied onto the surface of large appliances.

Light liquid means VOM in the liquid state which is not defined as heavy liquid.

Light-duty truck means any motor vehicle rated at 3,850 kg gross vehicle weight or less, designed mainly to transport property.

Liquid/gas method means either of two methods for determining capture which require both gas phase and liquid phase measurements and analysis. The first method requires construction of a TTE. The second method uses the building or room which houses the facility as an enclosure. The second method requires that all other VOM sources within the room be shut down while the test is performed, but all fans and blowers within the room must be operated according to normal procedures.

Liquid service means that the equipment or component contains process fluid that is in a liquid state at operating conditions.

Lithographic printing line means a printing line, except that the substrate is not necessarily fed from an unwinding roll, in which each roll printer uses a roll where both the image and non-image areas are essentially in the same plane (planographic).

Magnet wire means aluminum or copper wire formed into an electromagnetic coil.

Magnet wire coating means any coating or electrically insulating varnish or enamel applied to magnet wire.

Magnet wire coating facility means a facility that includes one or more magnet wire coating line(s).

Magnet wire coating line means a coating line in which any protective, decorative, or functional coating is applied onto the surface of a magnet wire.

Malfunction means any sudden and unavoidable failure of air pollution control equipment, process equipment, or a process to operate in a normal or usual manner. Failures that are caused entirely or in part by poor maintenance, careless operation, or any other preventable upset condition or preventable equipment breakdown shall not be considered malfunctions.

Manufacturing process means a method whereby a process emission source or series of process emission sources is used to convert raw materials, feed stocks, subassemblies, or other components into a product, either for sale or for use as a component in a subsequent manufacturing process.

Maximum theoretical emissions means the quantity of volatile organic material emissions that theoretically could be emitted by a stationary source before add-on controls based on the design capacity or maximum production capacity of the source and 8760 hours per year. The design capacity or maximum production capacity includes use of coating(s) or ink(s) with the highest volatile organic material content actually used in practice by the source.

Metal furniture means a furniture piece including, but not limited to, tables, chairs, waste baskets, beds, desks, lockers, benches, shelving, file cabinets, lamps, and room dividers.

Metal furniture coating means any non-adhesive coating applied to any furniture piece made of metal or any metal part which is or will be assembled with other metal, wood, fabric, plastic or glass parts to form a furniture piece including, but not limited to, tables, chairs, waste baskets, beds, desks, lockers, benches, shelving, file cabinets, lamps, and room dividers. This definition shall not apply to any coating line coating miscellaneous metal parts or products.

Metal furniture coating facility means a facility that includes one or more metal furniture coating line(s).

Metal furniture coating line means a coating line in which any protective, decorative, or functional coating is applied onto the surface of metal furniture.

Metallic shoe-type seal means a primary or secondary seal constructed of metal sheets (shoes) which are joined together to form a ring, springs, or levers which attach the shoes to the floating roof and hold the shoes against the tank wall, and a coated fabric which is suspended from the shoes to the floating roof.

Miscellaneous fabricated product manufacturing process means:

(A) A manufacturing process involving one or more of the following applications, including any drying and curing of formulations, and capable of emitting VOM:

(1) Adhesives to fabricate or assemble components or products.

(2) Asphalt solutions to paper or fiberboard.

(3) Asphalt to paper or felt.

(4) Coatings or dye to leather.

(5) Coatings to plastic.

(6) Coatings to rubber or glass.

(7) Disinfectant material to manufactured items.

(8) Plastic foam scrap or “fluff” from the manufacture of foam containers and packaging material to form resin pallets.

(9) Resin solutions to fiber substances.

(10) Viscose solutions for food casings.

(B) The storage and handling of formulations associated with the process described above, and the use and handling of organic liquids and other substances for clean-up operations associated with the process described in this definition.

Miscellaneous formulation manufacturing process means:

(A) A manufacturing process which compounds one or more of the following and is capable of emitting VOM:

(1) Adhesives.

(2) Asphalt solutions.

(3) Caulks, sealants, or waterproofing agents.

(4) Coatings, other than paint and ink.

(5) Concrete curing compounds.

(6) Dyes.

(7) Friction materials and compounds.

(8) Resin solutions.

(9) Rubber solutions.

(10) Viscose solutions.

(B) The storage and handling of formulations associated with the process described above, and the use and handling of organic liquids and other substances for clean-up operations associated with the process described in this definition.

Miscellaneous metal parts or products means any metal part or metal product, even if attached to or combined with a nonmental part or product, except cans, coils, metal furniture, large appliances, magnet wire, automobiles, ships, and airplane bodies.

Miscellaneous metal parts and products coating means any coating applied to any metal part or metal product, even if attached to or combined with a nonmetal part or product, except cans, coils, metal furniture, large appliances, and magnet wire. Prime coat, prime surfacer coat, topcoat, and final repair coat for automobiles and light-duty trucks are not miscellaneous metal parts and products coatings. However, underbody anti-chip (e.g., underbody plastisol) automobile, and light-duty truck coatings are miscellaneous metal parts and products coatings. Also, automobile or light-duty truck refinishing coatings, coatings applied to the exterior of marine vessels, coatings applied to the exterior of airplanes, and the customized topcoating of automobiles and trucks if production is less than 35 vehicles per day are not miscellaneous metal parts and products coatings.

Miscellaneous metal parts or products coating facility means a facility that includes one or more miscellaneous metal parts or products coating lines.

Miscellaneous metal parts or products coating line means a coating line in which any protective, decorative, or functional coating is applied onto the surface of miscellaneous metal parts or products.

Miscellaneous organic chemical manufacturing process means:

(A) A manufacturing process which produces by chemical reaction, one or more of the following organic compounds or mixtures of organic compounds and which is capable of emitting VOM:

(1) Chemicals listed in appendix A of this section.

(2) Chlorinated and sulfonated compounds.

(3) Cosmetic, detergent, soap, or surfactant intermediaries or specialties and products.

(4) Disinfectants.

(5) Food additives.

(6) Oil and petroleum product additives.

(7) Plasticizers.

(8) Resins or polymers.

(9) Rubber additives.

(10) Sweeteners.

(11) Varnishes.

(B) The storage and handling of formulations associated with the process described above and the use and handling of organic liquids and other substances for clean-up operations associated with the process described in this definition.

Monitor means to measure and record.

Multiple package coating means a coating made from more than one different ingredient which must be mixed prior to using and has a limited pot life due to the chemical reaction which occurs upon mixing.

Offset means, with respect to printing and publishing operations, use of a blanket cylinder to transfer ink from the plate cylinder to the surface to be printed.

Opaque stains means all stains that are not semi-transparent stains.

Open top vapor depressing means the batch process of cleaning and removing soils from surfaces by condensing hot solvent vapor on the colder metal parts.

Open-ended valve means any valve, except pressure relief devices, having one side of the valve in contact with process fluid and one side open to the atmosphere, either directly or through open piping.

Organic compound means any compound of carbon, excluding carbon monoxide, carbon dioxide, carbonic acid, metallic carbides or carbonates, and ammonium carbonate.

Organic material means any chemical compound of carbon including diluents and thinners which are liquids at standard conditions and which are used as dissolvers, viscosity reducers, or cleaning agents, but excluding methane, carbon monoxide, carbon dioxide, carbonic acid, metallic carbonic acid, metallic carbide, metallic carbonates, and ammonium carbonate.

Organic vapor means the gaseous phase of an organic material or a mixture of organic materials present in the atmosphere.

Oven means a chamber within which heat is used for one or more of the following purposes: Dry, bake, cure, or polymerize a coating or ink.

Overall control means the product of the capture efficiency and the control device efficiency.

Overvarnish means a transparent coating applied directly over ink or coating.

Owner or operator means any person who owns, operates, leases, controls, or supervises an emission source or air pollution control equipment.

Packaging rotogravure printing means rotogravure printing upon paper, paper board, metal foil, plastic film, and other substrates, which are, in subsequent operations, formed into packaging products or labels for articles to be sold.

Packaging rotogravure printing line means a rotogravure printing line in which surface coatings are applied to paper, paperboard, foil, film, or other substrates which are to be used to produce containers, packaging products, or labels for articles.

Pail means any cylindrical metal shipping container of 1- to 12-gallon capacity and constructed of 29-gauge and heavier metal.

Paint manufacturing plant means a plant that mixes, blends, or compounds enamels, lacquers, sealers, shellacs, stains, varnishes, or pigmented surface coatings.

Paper coating means any coating applied on paper, plastic film, or metallic foil to make certain products, including (but not limited to) adhesive tapes and labels, book covers, post cards, office copier paper, drafting paper, or pressure sensitive tapes. Paper coating includes the application of coatings by impregnation and/or saturation.

Paper coating facility means a facility that includes one or more paper coating lines.

Paper coating line means a coating line in which any protective, decorative, or functional coating is applied on, saturated into, or impregnated into paper, plastic film, or metallic foil to make certain products, including (but not limited to) adhesive tapes and labels, book covers, post cards, office copier paper, drafting paper, and pressure sensitive tapes.

Parts per million (volume) means a volume/volume ratio which expresses the volumetric concentration of gaseous air contaminant in a million unit volume of gas.

Person means any individual, corporation, partnership, association, State, municipality, political subdivision of a State; any agency, department, or instrumentality of the United States; and any officer, agent, or employee thereof.

Petroleum means the crude oil removed from the earth and the oils derived from tar sands, shale, and coal.

Petroleum refinery means any facility engaged in producing gasoline, kerosene, distillate fuel oils, residual fuel oils, lubricants, or other products through distillation of petroleum, or through redistillation, cracking, or reforming of unfinished petroleum derivatives.

Pharmaceutical means any compound or mixture, other than food, used in the prevention, diagnosis, alleviation, treatment, or cure of disease in man and animal.

Pharmaceutical coating operation means a device in which a coating is applied to a pharmaceutical, including air drying or curing of the coating.

Pigmented coatings means opaque coatings containing binders and colored pigments which are formulated to conceal the wood surface either as an undercoat or topcoat.

Plant means all of the pollutant-emitting activities which belong to the same industrial grouping, are located on one or more contiguous or adjacent properties, and are under the control of the same person (or persons under common control), except the activities of any marine vessel. Pollutant-emitting activities shall be considered as part of the same industrial grouping if they belong to the same “Major Group” (i.e., which have the same two-digit code) as described in the “Standard Industrial Classification Manual, 1987” (incorporated by reference as specified in 40 Cspan 52.742).

Plasticizers means a substance added to a polymer composition to soften and add flexibility to the product.

Prime coat means the first of two or more coatings applied to a surface.

Prime surfacer coat means a coating used to touch up areas on the surface of automobile or light-duty truck bodies not adequately covered by the prime coat before application of the top coat. The prime surfacer coat is applied between the prime coat and topcoat. An anti-chip coating applied to main body parts (e.g., rocker panels, bottom of doors and fenders, and leading edge of roof) is a prime surfacer coat.

Primers means any coatings formulated and applied to substrates to provide a firm bond between the substrate and subsequent coats.

Printing means the application of words, designs, and pictures to a substrate using ink.

Printing line means an operation consisting of a series of one or more roll printers and any associated roll coaters, drying areas, and ovens wherein one or more coatings are applied, dried, and/or cured.

Process means any stationary emission source other than a fuel combustion emission source or an incinerator.

Production equipment exhaust system means a system for collecting and directing into the atmosphere emissions of volatile organic material from reactors, centrifuges, and other process emission sources.

Publication rotogravure printing line means a rotogravure printing line in which coatings are applied to paper which is subsequently formed into books, magazines, catalogues, brochures, directories, newspaper supplements, or other types of printed material.

Reactor means a vat, vessel, or other device in which chemical reactions take place.

Refiner means any person who owns, leases operates, controls, or supervises a refinery.

Refinery unit, process unit or unit means a set of components which are a part of a basic process operation such as distillation, hydrotreating, cracking, or reforming of hydrocarbons.

Refrigerated condenser means a surface condenser in which the coolant supplied to the condenser has been cooled by a mechanical device, other than by a cooling tower or evaporative spray cooling, such as refrigeration unit or steam chiller unit.

Repair coatings means coatings used to correct imperfections or damage to furniture surface.

Repaired means, for the purpose of paragraph (i) of this section, that equipment component has been adjusted, or otherwise altered, to eliminate a leak.

Roll coater means an apparatus in which a uniform layer of coating is applied by means of one or more rolls across the entire width of a moving substrate.

Roll printer means an apparatus used in the application of words, designs, or pictures to a substrate, usually by means of one or more rolls each with only partial coverage.

Roll printing means the application of words, designs, and pictures to a substrate usually by means of a series of hard rubber or metal rolls each with only partial coverage.

Roller coating means a method of applying a coating to a sheet or strip in which the coating is transferred by a roller or series of rollers.

Rotogravure printing means the application of words, designs, and pictures to a substrate by means of a roll printing technique in which the pattern to be applied is recessed relative to the non-image area.

Rotogravure printing line means a printing line in which each roll printer uses a roll with recessed areas for applying an image to a substrate.

Safety relief valve means a valve which is normally closed and which is designed to open in order to relieve excessive pressures within a vessel or pipe.

Sanding sealers means any coatings formulated for and applied to bare wood for sanding and to seal the wood for subsequent application of varnish. To be considered a sanding sealer a coating must be clearly labelled as such.

Sealer means a coating containing binders which seals wood prior to the application of the subsequent coatings.

Semi-transparent stains means stains containing dyes or semi-transparent pigments which are formulated to enhance wood grain and change the color of the surface but not to conceal the surface, including, but not limited to, sap stain, toner, non-grain raising stains, pad stain, or spatter stain.

Set of safety relief valves means one or more safety relief valves designed to open in order to relieve excessive pressures in the same vessel or pipe.

Sheet basecoat means a coating applied to metal when the metal is in sheet form to serve as either the exterior or interior of a can for either two-piece or three-piece cans.

Side-seam spray coat means a coating applied to the seam of a three-piece can.

Single coat means one coating application applied to a metal surface.

Solvent means a liquid substance that is used to dissolve or dilute another substance.

Solvent cleaning means the process of cleaning soils from surfaces by cold cleaning, open top vapor degreasing, or conveyorized degreasing.

Specified air contaminant means any air contaminant as to which this Section contains emission standards or other specific limitations.

Splash loading means a method of loading a tank, railroad tank car, tank truck, or trailer by use of other than a submerged loading pipe.

Standard conditions means a temperature of 70 °F and a pressure of 14.7 psia.

Standard cubic foot (scf) means the volume of one cubic foot of gas at standard conditions.

Standard Industrial Classification Manual means the Standard Industrial Classification Manual (1987), Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402 (incorporated by reference as specified in 40 Cspan 52.742).

Start-up means the setting in operation of an emission source for any purpose.

Stationary emission source and Stationary source mean an emission source which is not self-propelled.

Storage tank or storage vessel means any stationary tank, reservoir or container used for the storage of VOL's.

Submerged loading pipe means any discharge pipe or nozzle which meets either of the following conditions:

(A) Where the tank is filled from the top, the end of the discharge pipe or nozzle must be totally submerged when the liquid level is 15 cm (6 in.) above the bottom of the tank.

(B) Where the tank is filled from the side, the discharge pipe or nozzle must be totally submerged when the liquid level is 46 cm (18 in.) above the bottom of the tank.

Substrate means the surface onto which a coating is applied or into which a coating is impregnated.

Surface condenser means a device which removes a substance from a gas stream by reducing the temperature of the stream, without direct contact between the coolant and the stream.

Tablet coating operation means a pharmaceutical coating operation in which tablets are coated.

Thirty-day rolling average means any value arithmetically averaged over any consecutive thirty-days.

Three-piece can means a can which is made from a rectangular sheet and two circular ends.

Topcoat means a coating applied in a multiple coat operation other than prime coat, final repair coat, or prime surfacer coat.

Topcoat operation means all topcoat spray booths, flash-off areas, and bake ovens at a facility which are used to apply, dry, or cure the final coatings (except final off-line repair) on components of automobile or light-duty truck bodies.

Transfer efficiency means the ratio of the amount of coating solids deposited onto a part or product to the total amount of coating solids used.

True vapor pressure means the equilibrium partial pressure exerted by a volatile organic liquid as determined in accordance with methods described in American Petroleum Institute Bulletin 2517, “Evaporation Loss From Floating Roof Tanks,” second edition, February 1980 (incorporated by reference as specified in 40 Cspan 52.742).

Two-piece can means a can which is drawn from a shallow cup and requires only one end to be attached.

Undercoaters means any coatings formulated for and applied to substrates to provide a smooth surface for subsequent coats.

Unregulated safety relief valve means a safety relief valve which cannot be actuated by a means other than high pressure in the pipe or vessel which it protects.

Vacuum producing system means any reciprocating, rotary, or centrifugal blower or compressor or any jet ejector or device that creates suction from a pressure below atmospheric and discharges against a greater pressure.

Valves not externally regulated means valves that have no external controls, such as in-line check valves.

Vapor balance system means any combination of pipes or hoses which creates a closed system between the vapor spaces of an unloading tank and a receiving tank such that vapors displaced from the receiving tank are transferred to the tank being unloaded.

Vapor collection system means all piping, seals, hoses, connections, pressure-vacuum vents, and other possible sources between the gasoline delivery vessel and the vapor processing unit and/or the storage tanks and vapor holder.

Vapor control system means any system that limits or prevents release to the atmosphere of organic material in the vapors displaced from a tank during the transfer of gasoline.

Vapor recovery system means a vapor gathering system capable of collecting all VOM vapors and gases discharged from the storage tank and a vapor disposal system capable of processing such VOM vapors and gases so as to prevent their emission to the atmosphere.

Vehicle means a device by which any person or property may be propelled, moved, or drawn upon a highway, excepting a device moved exclusively by human power or used exclusively upon stationary rails or tracks.

Vinyl coating means any topcoat or printing ink applied to vinyl coated fabric or vinyl sheets. Vinyl coating does not include plastisols.

Vinyl coating facility means a facility that includes one or more vinyl coating line(s).

Vinyl coating line means a coating line in which any protective, decorative or functional coating is applied onto vinyl coated fabric or vinyl sheets.

Volatile organic liquid means any substance which is liquid at storage conditions and which contains volatile organic compounds.

Volatile organic material (VOM) or volatile organic compounds (VOC) is as defined in § 51.100(s) of this chapter.

Wash coat means a coating containing binders which seals wood surfaces, prevents undesired staining, and controls penetration.

Web means a substrate which is printed in continuous roll-fed presses.

Wood furniture means room furnishings including cabinets (kitchen, bath, and vanity), tables, chairs, beds, sofas, shutters, art objects, wood paneling, wood flooring, and any other coated furnishings made of wood, wood composition, or fabricated wood materials.

Wood furniture coating facility means a facility that includes one or more wood furniture coating line(s).

Wood furniture coating line means a coating line in which any protective, decorative, or functional coating is applied onto wood furniture.

Woodworking means the shaping, sawing, grinding, smoothing, polishing, and making into products of any form or shape of wood.

(4) Testing methods and procedures—(i) Coatings, inks and fountain solutions. The following test methods and procedures shall be used to determine compliance of as applied coatings, inks, and fountain solutions with the limitations set forth in § 52.741.

(A) Sampling. Samples collected for analyses shall be one-liter taken into a one-liter container at a location and time such that the sample will be representative of the coating as applied (i.e., the sample shall include any dilution solvent or other VOM added during the manufacturing process). The container must be tightly sealed immediately after the sample is taken. Any solvent or other VOM added after the sample is taken must be measured and accounted for in the calculations in paragraph (a)(4)(i)(C) of this section. For multiple package coatings, separate samples of each component shall be obtained. A mixed sample shall not be obtained as it will cure in the container. Sampling procedures shall follow the guidelines presented in:

(1) ASTM D3925-81 (Reapproved 1985) Standard Practice for Sampling Liquid Paints and Related Pigment Coating. This practice is incorporated by reference as specified in 40 Cspan 52.742.

(2) ASTM E300-86 Standard Practice for Sampling Industrial Chemicals. This practice is incorporated by reference as specified in 40 Cspan 52.742.

(B) Analyses. The applicable analytical methods specified below shall be used to determine the composition of coatings, inks, or fountain solutions as applied.

(1) Method 24 of 40 Cspan part 60, appendix A, shall be used to determine the VOM content and density of coatings. If it is demonstrated to the satisfaction of the Administrator that plant coating formulation data are equivalent to Method 24 results, formulation data may be used. In the event of any inconsistency between a Method 24 test and a facility's formulation data, the Method 24 test will govern.

(2) Method 24A of 40 Cspan part 60, appendix A, shall be used to determine the VOM content and density of rotogravure printing inks and related coatings. If it is demonstrated to the satisfaction of the Administrator that the plant coating formulation data are equivalent to Method 24A results, formulation data may be used. In the event of any inconsistency between a Method 24A test and a facility's formulation data, the Method 24A test will govern.

(3) The following ASTM methods are the analytical procedures for determining VOM:

(i) ASTM D1475-85: Standard Test Method for Density of Paint, Varnish, Lacquer and Related Products. This test method is incorporated by reference as specified in 40 Cspan 52.742.

(ii) ASTM D2369-87: Standard Test Method for Volatile Content of Coatings. This test method is incorporated by reference as specified in 40 Cspan 52.742.

(iii) ASTM D3792-86: Standard Test Method for Water Content of Water-reducible Paints by Direct Injection into a Gas Chromatograph. This test method is incorporated by reference as specified in 40 Cspan 52.742.

(iv) ASTM D4017-81 (Reapproved 1987): Standard Test Method for Water in Paints and Paint Materials by the Karl Fischer Method. This test method is incorporated by reference as specified in 40 Cspan 52.742.

(v) ASTM D4457-85: Standard Test Method for Determination of Dichloromethane and 1,1,1-Trichloroethane in Paints and Coatings by Direct Injection into a Gas Chromatograph. (The procedure delineated above can be used to develop protocols for any compounds specifically exempted from the definition of VOM.) This test method is incorporated by reference as specified in 40 Cspan 52.742.

(vi) ASTM D2697-86: Standard Test Method for Volume Non-Volatile Matter in Clear or Pigmented Coatings. This test method is incorporated by reference as specified in 40 Cspan 52.742.

(vii) ASTM D3980-87: Standard Practice for Interlaboratory Testing of Paint and Related Materials. This practice is incorporated by reference as specified in 40 Cspan 52.742.

(viii) ASTM E180-85: Standard Practice for Determining the Precision of ASTM Methods for Analysis of and Testing of Industrial Chemicals. This practice is incorporated by reference as specified in 40 Cspan 52.742.

(ix) ASTM D2372-85: Standard Method of Separation of Vehicle from Solvent-reducible Paints. This method is incorporated by reference as specified in 40 Cspan 52.742.

(4) Use of an adaptation to any of the analytical methods specified in paragraphs (a)(4)(i)(B)(1), (2) and (3) may be approved by the Administrator on a case-by-case basis. An owner or operator must submit sufficient documentation for the Administrator to find that the analytical methods specified in paragraphs (a)(4)(i)(B)(1), (2) and (3) will yield inaccurate results and that the proposed adaptation is appropriate.

(C) Calculations. Calculations for determining the VOM content, water content and the content of any compounds which are specifically exempted from the definition of VOM of coatings, inks and fountain solutions as applied shall follow the guidance provided in the following documents.

(1) “A Guide for Surface Coating Calculation” EPA-340/1-86-016 (which is available from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(2) “Procedures for Certifying Quantity of Volatile Organic Compounds Emitted by Paint, Ink and Other Coatings” (revised June 1986) EPA-450/3-84-019 (which is available from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(3) “A Guide for Graphic Arts Calculations” August 1988 EPA-340/1-88-003 (which is available from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(ii) Automobile or light-duty truck test protocol. The protocol for testing, including determining the transfer efficiency, of coating applicators at topcoat coating operations at an automobile assembly facility shall follow the procedure in: “Protocol for Determining the Daily Volatile Organic Compound Emission Rate of Automobile and Light-Duty Truck Topcoat Operations” December 1988 EPA-450/3-88-018 (which is available for purchase from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(iii) Capture system efficiency test protocols—(A) Applicability. The requirements of paragraphs (a)(4)(iii)(B) of this section shall apply to all VOM emitting processes employing capture equipment (e.g., hoods, ducts), except those cases noted below.

(1) If a source installs a permanent total enclosure (PTE) that meets USEPA specifications, and which directs all VOM to a control device, then the source is exempted from the requirements described in paragraph (B). The USEPA specifications to determine whether a structure is considered a PTE are given in Procedure T of appendix B of this section. In this instance, the capture efficiency is assumed to be 100 percent and the source is still required to measure control efficiency using appropriate test methods as specified in (a)(4)(iv) of this section.

(2) If a source uses a control device designed to collect and recover VOM (e.g., carbon adsorber), an explicit measurement of capture efficiency is not necessary provided that the conditions given below are met. The overall control of the system can be determined by directly comparing the input liquid VOM to the recovered liquid VOM. The general procedure for use in this situation is given in 40 Cspan 60.433, with the following additional restrictions:

(i) The source must be able to equate solvent usage with solvent recovery on a 24-hour (daily) basis, rather than a 30-day weighted average, within 72 hours following the 24-hour period. In addition, one of the following two criteria must be met:

(ii) The solvent recovery system (i.e., capture and control system) must be dedicated to a single process line (e.g., one process line venting to a carbon adsorber system), or

(iii) If the solvent recovery system controls multiple process lines, then the source must be able to demonstrate that the overall control (i.e., the total recovered solvent VOM divided by the sum of liquid VOM input to all process lines venting to the control system) meets or exceeds the most stringent standard applicable for any process line venting to the control system.

(B) Specific requirements. The capture efficiency of a process line shall be measured using one of the four protocols given below. Any error margin associated with a test protocol may not be incorporated into the results of a capture efficiency test. If these techniques are not suitable for a particular process, then the source must present an alternative capture efficiency protocol and obtain approval for it by the Administrator as a SIP or FIP revisions.

(1) Gas/gas method using temporary total enclosure (TTE). The USEPA specifications to determine whether a temporary enclosure is considered a TTE are given in Procedure T of appendix B of this section. The capture efficiency equation to be used for this protocol is:

CE = Gw / (GW + Fw) Where: CE = capture efficiency, decimal fraction. Gw = mass of VOM captured and delivered to control device using a TTE. Fw = mass of fugitive VOM that escapes from a TTE. Procedure G.2 contained in appendix B of this section is used to obtain Gw. Procedure F.1 in appendix B of this section is used to obtain Fw.

(2) Liquid/gas method using TTE. The USEPA specifications to determine whether a temporary enclosure is considered a TTE are given in Procedure T of appendix B of this section. The capture efficiency equation to be used for this protocol is:

CE = (L − F) / L Where: CE = capture efficiency, decimal fraction. L = mass of liquid VOM input to process. Fw = mass of fugitive VOM that escapes from a TTE. Procedure L contained in appendix B of this section is used to obtain L. Procedure F.1 in appendix B of this section is used to obtain Fw.

(3) Gas/gas method using the building or room (building or room enclosure) in which the affected source is located as the enclosure and in which “F” and “G” are measured while operating only the affected facility. All fans and blowers in the building or room must be operated as they would under normal production. The capture efficiency equation to be used for this protocol is:

CE = G / (G + FB) Where: CE = capture efficiency, decimal fraction. G = mass of VOM captured and delivered to control device. FB = mass of fugitive VOM that escapes from building enclosure. Procedure G.2 contained in appendix B of this section is used to obtain G. Procedure F.2 in appendix B of this section is used to obtain FB.

(4) Liquid/gas method using the building or room (building or room enclosure) in which the affected source is located as the enclosure and in which “F” and “L” are measured while operating only the affected facility. All fans and blowers in the building or room must be operated as they would under normal production. The capture efficiency equation to be used for this protocol is:

CE = (L − FB) / L Where: CE = capture efficiency, decimal fraction. L = mass of liquid VOM input to process. FB = mass of fugitive VOM that escapes from building enclosure. Procedure L contained in appendix B of this section is used to obtain L. Procedure F.2 in appendix B of this section is used to obtain FB.

(C) Recordkeeping and reporting. (1) All affected facilities must maintain a copy of the capture efficiency protocol submitted to USEPA on file. All results of the appropriate test methods and capture efficiency protocols must be reported to USEPA within sixty (60) days of the test date. A copy of the results must be kept on file with the source for a period of three (3) years.

(2) If any changes are made to capture or control equipment, then the source is required to notify USEPA of these changes and a new test may be required by USEPA.

(3) The source must notify the Administrator 30 days prior to performing any capture efficiency or control test. At that time, the source must notify the Administrator which capture efficiency protocol and control device test methods will be used.

(4) Sources utilizing a PTE must demonstrate that this enclosure meets the requirement given in Procedure T (in appendix B of this section) for a PTE during any testing of their control device.

(5) Sources utilizing a TTE must demonstrate that their TTE meets the requirements given in Procedure T (in appendix B of this section) for a TTE during testing of their control device. The source must also provide documentation that the quality assurance criteria for a TTE have been achieved.

(iv) Control device efficiency testing and monitoring. (A) The control device efficiency shall be determined by simultaneously measuring the inlet and outlet gas phase VOM concentrations and gas volumetric flow rates in accordance with the gas phase test methods specified in paragraph (a)(4)(vi) of this section.

(B) Any owner or operator that uses an afterburner or carbon adsorber to comply with any paragraph of § 52.741 shall use USEPA approved continuous monitoring equipment which is installed, calibrated, maintained, and operated according to vendor specifications at all times the afterburner or carbon adsorber is in use. The continuous monitoring equipment must monitor the following parameters:

(1) Combustion chamber temperature of each afterburner.

(2) Temperature rise across each catalytic afterburner bed or VOM concentration of exhaust.

(3) The VOM concentration of each carbon adsorption bed exhaust.

(v) Overall efficiency. (A) The overall efficiency of the emission control system shall be determined as the product of the capture system efficiency and the control device efficiency or by the liquid/liquid test protocol as specified in 40 Cspan 60.433 (and revised by paragraph (a)(4)(iii)(A)(2) of this section for each solvent recovery system. In those cases in which the overall efficiency is being determined for an entire line, the capture efficiency used to calculate the product of the capture and control efficiency is the total capture efficiency over the entire line.

(B) For coating lines which are both chosen by the owner or operator to comply with paragraphs (e)(2)(ii), (e)(2)(iii), (e)(2)(iv), (e)(2)(v), or (e)(2)(vi) of this section by the alternative in paragraph (e)(2)(i)(B) of this section and meet the criteria allowing them to comply with paragraph (e)(2) of this section instead of paragraph (e)(1) of this section, the overall efficiency of the capture system and control device, as determined by the test methods and procedures specified in paragraphs (a)(4) (iii), (iv) and (v)(A) of this section, shall be no less than the equivalent overall efficiency which shall be calculated by the following equation:

E = ([VOMa − VOM1]/VOMa) × 100 Where: E = Equivalent overall efficiency of the capture system and control device as a percentage, VOMa = Actual VOM content of a coating, or the daily-weighted average VOM content of two or more coatings (if more than one coating is used), as applied to the subject coating line as determined by the applicable test methods and procedures specified in paragraph (a)(4)(i) of this section in units of kg VOM/l (lb VOM/gal) of coating solids as applied, VOM1 = The VOM emission limit specified in paragraph (e)(2) (i) or (ii) of this section in units of kg VOM/l (lb VOM/gal) of coating solids as applied.

(vi) Volatile organic material gas phase source test methods. The methods in 40 Cspan part 60, appendix A, delineated below shall be used to determine control device efficiencies.

(A) 40 Cspan part 60, appendix A, Method 18, 25 or 25A, as appropriate to the conditions at the site, shall be used to determine VOM concentration. Method selection shall be based on consideration of the diversity of organic species present and their total concentration and on consideration of the potential presence of interfering gases. Except as indicated in paragraphs (a)(4)(vi)(A)(1) and (2) of this section, the test shall consist of three separate runs, each lasting a minimum of 60 min, unless the Administrator determines that process variables dictate shorter sampling times.

(1) When the method is to be used to determine the efficiency of a carbon adsoption system with a common exhaust stack for all the individual adsorber vessels, the test shall consist of three separate runs, each coinciding with one or more complete sequences through the adsorption cycles of all the individual adsorber vessels.

(2) When the method is to be used to determine the efficiency of a carbon adsorption system with individual exhaust stacks for each adsorber vessel, each adsorber vessel shall be tested individually. The test for each adsorber vessel shall consist of three separate runs. Each run shall coincide with one or more complete adsorption cycles.

(B) 40 Cspan part 60, appendix A, Method 1 or 1A shall be used for sample and velocity traverses.

(C) 40 Cspan part 60, appendix A, Method 2, 2A, 2C or 2D shall be used for velocity and volumetric flow rates.

(D) 40 Cspan part 60, appendix A, Method 3 shall be used for gas analysis.

(E) 40 Cspan part 60, appendix A, Method 4 shall be used for stack gas moisture.

(F) 40 Cspan part 60, appendix A, Methods 2, 2A, 2C, 2D, 3 and 4 shall be performed, as applicable, at least twice during each test run.

(G) Use of an adaptation to any of the test methods specified in paragraphs (a)(4)(vi) (A), (B), (C), (D), (E), and (F) of this section may be approved by the Administrator on a case-by-case basis. An owner or operator must submit sufficient documentation for the Administrator to find that the test methods specified in paragraphs (a)(4)(vi) (A), (B), (C), (D), (E), and (F) of this section will yield inaccurate results and that the proposed adaptation is appropriate.

(vii) Leak detection methods for volatile organic material. Owners or operators required by the various subparts of this regulation to carry out a leak detection monitoring program shall comply with the following requirements:

(A) Leak detection monitoring. (1) Monitoring shall comply with 40 Cspan part 60, appendix A. Method 21.

(2) The detection instrument shall meet the performance criteria of Method 21.

(3) The instrument shall be calibrated before use on each day of its use by the methods specified in Method 21.

(4) Calibration gases shall be:

(i) Zero air (less than 10 ppm of hydrocarbon in air); and

(ii) A mixture of methane or n-hexane and air at a concentration of approximately, but no less than, 10,000 ppm methane or n-hexane.

(5) The instrument probe shall be traversed around all potential leak interfaces as close to the interface as possible as described in Method 21.

(B) When equipment is tested for compliance with no detectable emissions as required, the test shall comply with the following requirements:

(1) The requirements of paragraphs (a)(4) (vii)(A)(1) through (vii)(A)(5) of this section shall apply.

(2) The background level shall be determined as set forth in Method 21.

(C) Leak detection tests shall be performed consistent with:

(1) “APTI Course SI 417 controlling Volatile Organic Compound Emissions from Leaking Process Equipment” EPA-450/2-82-015 (which is available for purchase from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(2) “Portable Instrument User's Manual for Monitoring VOC Sources” EPA-340/1-86-015 (which is available for purchase from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(3) “Protocols for Generating Unit-Specific Emission Estimates for Equipment Leaks of VOC and VHAP” EPA-450/3-88-010 (which is available for purchase from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(4) “Petroleum Refinery Enforcement Manual” EPA-340/1-80-008 (which is available for purchase from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(viii) Bulk gasoline delivery system test protocol. (A) The method for determining the emissions of gasoline from a vapor recovery system are delineated in 40 Cspan part 60, subpart XX, § 60.503.

(B) Other tests shall be performed consistent with:

(1) “Inspection Manual for Control of Volatile Organic Emissions from Gasoline Marketing Operations: Appendix D” EPA-340/1-80-012 (which is available for purchase from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(2) “Control of Hydrocarbons from Tank Truck Gasoline Loading Terminals: Appendix A” EPA-450/2-77-026 (which is available for purchase from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161)

(5) Compliance dates. Compliance with the requirements of all rules is required by July 1, 1991, unless otherwise indicated by compliance dates contained in specific rules. This paragraph shall not operate to provide additional time for compliance under section 113(d) of the Act, 42 U.S.C. 7413(d), for sources subject to compliance upon promulgation.

(6) Afterburners. The operation of any natural gas fired afterburner and capture system used to comply with § 52.741 is not required during the period of November 1 of any year to April 1 of the following year provided that the operation of such devices is not required for purposes of occupational safety or health, or for the control of toxic substances, odor nuisances, or other regulated pollutants.

(7) Exemptions, variances, and alternative means of control or compliance determinations. Notwithstanding the provisions of any other paragraphs of this section, any exemptions, variances or alternatives to the control requirements, emission limitations, or test methods in the Illinois SIP or FIP can only be allowed if approved by the Administrator as a SIP or FIP revision.

(8) Vapor pressure of volatile organic liquids. (i) If the VOL consists of only a single compound, the vapor pressure shall be determined by ASTM Method D2879-86 (incorporated by reference as specified in 40 Cspan 52.742) or the vapor pressure may be obtained from a published source such as: Boublik, T., V. Fried and E. Hala, “The Vapor Pressure of Pure Substances,” Elsevier Scientific Publishing Co., New York (1973); Perry's Chemical Engineer's Handbook, McGraw-Hill Book Company (1984); CRC Handbook of Chemistry and Physics, Chemical Rubber Publishing Company (1986-87); and Lange's Handbook of Chemistry, John A. Dean, editor, McGraw-Hill Book Company (1985).

(ii) If the VOL is a mixture, the vapor pressure shall be determined by ASTM Method D2879-86 (incorporated by reference as specified in 40 Cspan 52.742) or by the following equation:

Where: Pvol = Total vapor pressure of the mixture, n = Number of components in the mixture, i = Subscript denoting an individual component, Pi = Vapor pressure of a component determined in accordance with paragraph (a) of this section Xi = Mole fraction of the component in the total mixture.

(9) Vapor pressure of organic material or solvent. (i) If the organic material or solvent consists of only a single compound, the vapor pressure shall be determined by ASTM Method D2879-86 (incorporated by reference as specified in 40 Cspan 52.742) or the vapor pressure may be obtained from a published source such as: Boublik, T., V. Fried and E. Hala, “The Vapor Pressure of Pure Substances,” Elsevier Scientific Publishing Co., New York (1973); Perry's Chemical Engineer's Handbook, McGraw-Hill Book Company (1984); CRC Handbook of Chemistry and Physics, Chemical Rubber Publishing Company (1986-87); and Lange's Handbook of Chemistry, John A. Dean, editor, McGraw-Hill Book Company (1985).

(ii) If the organic material or solvent is in a mixture made up of both organic material compounds and compounds which are not organic material, the vapor pressure shall be determined by the following equation:

Where: Pom = Total vapor pressure of the portion of the mixture which is composed of organic material, n = Number of organic material components in the mixture, i = Subscript denoting an individual component, Pi = Vapor pressure of an organic material component determined in accordance with paragraph (a) of this section, Xi = Mole fraction of the organic material component of the total mixture.

(iii) If the organic material or solvent is in a mixture made up of only organic material compounds, the vapor pressure shall be determined by ASTM Method D2879-86 (incorporated by reference as specified in 40 Cspan 52.742) or by the above equation.

(10) Vapor pressure of volatile organic material. (i) If the VOM consists of only a single compound, the vapor pressure shall be determined by ASTM Method D2879-86 (incorporated by reference as specified in 40 Cspan 52.742) or the vapor pressure may be obtained from a published source such as: Boublik, T., V. Fried and E. Hala, “The Vapor Pressure of Pure Substances,” Elsevier Scientific Publishing Co., New York (1973); Perry's Chemical Engineer's Handbook, McGraw-Hill Book Company (1984); CRC Handbook of Chemistry and Physics, Chemical Rubber Publishing Company (1986-87); and Lange's Handbook of Chemistry, John A. Dean, editor, McGraw-Hill Book Company (1985).

(ii) If the VOM is in a mixture made up of both VOM compounds and compounds which are not VOM, the vapor pressure shall be determined by the following equation:

Where: Pvom = Total vapor pressure of the portion of the mixture which is composed of VOM, n = Number of VOM components in the mixture, i = Subscript denoting an individual component, Pi = Vapor pressure of a VOM component determined in accordance with paragraph (a) of this section, Xi = Mole fraction of the VOM component of the total mixture.

(iii) If the VOM is in a mixture made up of only VOM compounds, the vapor pressure shall be determined by ASTM Method D2879-86 (incorporated by reference as specified in 40 Cspan 52.742) or by the above equation.

(b)-(c) [Reserved]

(d) Solvent cleaning—(1) Solvent cleaning in general. The requirements of subpart E (sections 215.182-215.184) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) shall apply to all cold cleaning, open top vapor degreasing, and conveyorized degreasing operations.

Note:

For Federal purposes, paragraph (d)(1) supersedes subpart E (section 215.181) of 35 Ill. Adm. Code 215.)

(2) Compliance schedule. Every owner or operator of an emission source which was previously exempt from the requirements of subpart E (sections 215.182-215.184) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) because it satisfied the criteria in either (d)(a)(i) or (d)(2)(ii) of this section, shall comply with the requirements of subpart E (sections 215.182-215.184) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) on and after July 1, 1991. A source which did not satisfy the criteria in either (d)(a)(i) or (d)(2)(ii) of this section, shall comply with the requirements of subpart E (sections 215.182-215.184) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) upon promulgation.

(i) If emissions of VOM exceed neither 6.8 kg (15 lbs) in any one day, nor 1.4 kg (3 lbs) in any one hour, or

(ii) If the source is used exclusively for chemical or physical analysis or for determination of product quality and commercial acceptance, provided that the operation of the source is not an integral part of the production process, the emissions of VOM from the source do not exceed 363 kg (800 lbs) in any calendar month, and the exemption had been approved in writing by the Illinois Environmental Protection Agency.

(3) Test methods. The following test methods shall be used to demonstrate compliance with subpart E (sections 215.182-215.184) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742):

(i) Vapor pressures shall be determined by using the procedure specified in paragraph (a)(9) of this section.

(ii) Exhaust ventilation rates shall be determined by using the procedures specified in paragraph (a)(4)(vi)(C) of this section.

(iii) The performance of control devices shall be determined by using the procedures specified in paragraph (a)(4)(vi) of this section.

(e) Coating operations—(1) Emission limitations for manufacturing plants. (i) Except as provided in paragraph (e)(3) of this section, no owner or operator of a coating line shall apply at any time any coating in which the VOM content exceeds the following emission limitations for the specified coating. The following emission limitations are expressed in units of VOM per volume of coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied at each coating applicator, except where noted. Compounds which are specifically exempted from the definition of VOM should be treated as water for the purpose of calculating the “less water” part of the coating composition. Compliance with this paragraph must be demonstrated through the applicable coating analysis test methods and procedures specified in paragraph (a)(4)(i) of this section and the recordkeeping and reporting requirements specified in paragraph (e)(6)(ii) of this section. As an alternative to compliance with this paragraph, the owner or operator of a coating line may meet the requirements of paragraph (e)(1)(ii) or paragraph (e)(2) of this section. The equation presented in paragraph (e)(1)(iii) of this section shall be used to calculate emission limitations for determining compliance by add-on controls, credits for transfer efficiency, emissions trades and cross-line averaging.

kg/l lb/gal (A) Automobile or Light-Duty Truck Coating (1) Prime coat0.14(1.2) (2) Prime surfacer coat0.34(2.8) Note: The prime surfacer coat limitation is based upon a transfer efficiency of 30 percent. Transfer efficiency credits can only be allowed if approved by the Administrator as a SIP or FIP revision. (3) Topcoat1.81(15.1) Note: The topcoat limitation is in units of kg (lbs) of VOM per l (gal) of coating solids deposited. Compliance with the limitation shall be based on the daily-weighted average VOM content from the entire topcoat operation (all topcoat spray booths, flash-off areas and bake ovens). Compliance shall be demonstrated in accordance with the topcoat protocol for automobiles and light-duty trucks referenced in paragraph (a)(4)(ii) of this section. Paragraph (e)(1)(ii) of this section does not apply to the topcoat limitation.) At least 180 days prior to the initial compliance date, the owner or operator of a coating line subject to the topcoat limitation shall submit to the Administrator a detailed proposal specifying the method of demonstrating compliance with the protocol. The proposal shall include, at a minimum, a comprehensive plan (including a rationale) for determining the transfer efficiency at each booth through the use of in-plant, or pilot testing; the selection of coatings to be tested (for the purpose of determining transfer efficiency) including the rationale for coating groupings; and the method for determining the analytic VOM content of as applied coatings and the formulation solvent content of as applied coatings. Upon approval of the protocol by the Administrator, the source may proceed with the compliance demonstration. (4) Final repair coat0.58(4.8) (B) Can Coating (1) Sheet basecoat and overvarnish0.34(2.8) (2) Exterior basecoat and overvarnish0.34(2.8) (3) Interior body spray coat0.51(4.2) (4) Exterior end coat0.51(4.2) (5) Side seam spray coat0.66(5.5) (6) End sealing compound coat0.44(3.7) (C) Paper Coating0.35(2.9) Note: The paper coating limitation shall not apply to any owner or operator of any paper coating line on which printing is performed if the paper coating line complies with the emissions limitations in paragraph (h)(1) of this section: Printing and Publishing. (D) Coil Coating0.31(2.6) (E) Fabric Coating0.35(2.9) (F) Vinyl Coating0.45(3.8) (G) Metal Furniture Coating0.36(3.0) (H) Large Appliance Coating0.34(2.8) Note: The limitation shall not apply to the use of quick-drying lacquers for repair of scratches and nicks that occur during assembly, provided that the volume of coating does not exceed 0.95 l (1 quart) in any one rolling eight-hour period. (I) Magnet Wire Coating0.20(1.7) (J) Miscellaneous Metal Parts and Products Coating (1) Clear coating0.52(4.3) (2) Air-dried coating0.42(3.5) (3) Extreme performance coating0.42(3.5) (4) Steel pail and drum interior coating0.52(4.3) (5) All other coatings0.36(3.0)
kg/l lb/gal (K) Heavy Off-Highway Vehicle Products Coating (1) Extreme performance prime coat0.42(3.5) (2) Extreme performance top-coat (air dried)0.42(3.5) (3) Final repair coat (air dried)0.42(3.5) (4) All other coatings are subject to the emission limitations for miscellaneous metal parts and products coatings in paragraph (e)(1)(i)(J) of this section. (L) Wood Furniture Coating (1) Clear topcoat0.67(5.6) (2) Opaque stain0.56(4.7) (3) Pigmented coat0.60(5.0) (4) Repair coat0.67(5.6) (5) Sealer0.67(5.6) (6) Semi-transparent stain0.79(6.6) (7) Wash coat0.73(6.1) Note: An owner or operator of a wood furniture coating operation subject to this paragraph shall apply all coatings, with the exception of no more than 37.8 l (10 gal) of coating per day used for touch-up and repair operations, using one or more of the following application systems: airless spray application system, air-assisted airless spray application system, electrostatic spray application system, electrostatic bell or disc spray application system, heated airless spray application system, roller coating, brush or wipe coating application system, or dip coating application system. (M) Existing Diesel-Electric Locomotive Coating Lines in Cook County (1) Extreme performance prime coat0.42(3.5) (2) Extreme performance top-coat (air dried)0.42(3.5) (3) Final repair coat (air dried)0.42(3.5) (4) High-temperature aluminum coating0.72(6.0) (5) All other coatings0.36(3.0)

(ii) Daily-weighted average limitations. No owner or operator of a coating line subject to the limitations of paragraph (e)(1)(i) of this section and complying by means of paragraph (e)(1)(ii) of this section shall operate the subject coating line unless the owner or operator has demonstrated compliance with paragraph (e)(1) (ii)(A), (ii)(B), (ii)(C), (ii)(D), (ii)(E) or (ii)(F) of this section (depending upon the source category) through the applicable coating analysis test methods and procedures specified in paragraph (a)(4)(i) of this section and the recordkeeping and reporting requirements specified in paragraph (e)(6)(iii) of this section.

(A) No owner or operator of a coating line subject to only one of the limitations from among paragraph (e)(1) (i)(A)(1), (i)(A)(2), (i)(A)(4), (i)(C), (i)(D), (i)(E), (i)(F), (i)(G), (i)(H), or (i)(I) of this section shall apply coating on any such coating line, during any day, whose daily-weighted average VOM content exceeds the emission limitation to which the coatings are subject.

(B) No owner or operator of a miscellaneous metal parts and products coating line subject to the limitations of paragraph (e)(1)(i)(J) of this section shall apply coatings to miscellaneous metal parts or products on the subject coating line unless the requirements in paragraph (e)(1)(ii)(B) (1) or (2) of this section are met.

(1) For each coating line which applies multiple coatings, all of which are subject to the same numerical emission limitation within paragraph (e)(1)(i)(J) of this section, during the same day (e.g., all coatings used on the line are subject to 0.42 kg/l [3.5 lbs/gal]), the daily-weighted average VOM content shall not exceed the coating VOM content limit corresponding to the category of coating used, or

(2) For each coating line which applies coatings from more than one of the four coating categories in paragraph (e)(1)(i)(J) of this section, during the same day, the owner or operator shall submit to and receive approval from the Administrator for a site-specific FIP revision. To receive approval, the requirements of USEPA's Emissions Trading Policy Statement (and related policy) must be satisfied.

(C) No owner or operator of a can coating facility subject to the limitations of paragraph (e)(1)(i)(B) of this section shall operate the subject coating facility using a coating with a VOM content in excess of the limitations specified in paragraph (e)(1)(i)(B) of this section unless all of the following requirements are met:

(1) An alternative daily emission limitation shall be determined according to paragraph (e)(1)(ii)(C)(2) of this section. Actual daily emissions shall never exceed the alternative daily emission limitation and shall be calculated by use of the following equation.

Where: Ed = Actual VOM emissions for the day in units of kg/day (lbs/day), i = Subscript denoting a specific coating applied, n = Total number of coatings applied in the can coating operation, Vi = Volume of each coating applied for the day in units of l/day (gal/day) of coating (minus water and any compounds which are specifically exempted from the definition of VOM), and Ci = The VOM content of each coating as applied in units of kg VOM/l (lbs VOM/gal) of coating (minus water and any compounds which are specifically exempted from the definition of VOM).

(2) The alternative daily emission limitation (Ad) shall be determined on a daily basis as follows:

Where: Ad = The VOM emissions allowed for the day in units of kg/day (lbs/day), i = Subscript denoting a specific coating applied, n = Total number of surface coatings applied in the can coating operation, Ci = The VOM content of each surface coating as applied in units of kg VOM/l (lbs VOM/gal) of coating (minus water and any compounds which are specifically exempted from the definition of VOM), Di = The density of VOM in each coating applied. For the purposes of calculating Ad, the density is 0.882 kg VOM/l VOM (7.36 lbs VOM/gal VOM), Vi = Volume of each surface coating applied for the day in units of l (gal) of coating (minus water and any compounds which are specifically exempted from the definition of VOM), Li = The VOM emission limitation for each surface coating applied as specified in paragraph (e)(1)(i)(B) of this section in units of kg VOM/l (lbs VOM/gal) of coating (minus water and any compounds which are specifically exempted from the definition of VOM).

(D) No owner or operator of a heavy off-highway vehicle products coating line subject to the limitations of paragraph (e)(1)(i)(K) of this section shall apply coatings to heavy off-highway vehicle products on the subject coating line unless the requirements of paragraph (e)(1)(ii)(D) (1) or (2) of this section are met.

(1) For each coating line which applies multiple coatings, all of which are subject to the same numerical emission limitation within paragraph (e)(1)(i)(K) of this section, during the same day (e.g., all coatings used on the line are subject to 0.42 kg/l [3.5 lbs/gal]), the daily-weighted average VOM content shall not exceed the coating VOM content limit corresponding to the category of coating used, or

(2) For each coating line which applies coatings subject to more than one numerical emission limitation in paragraph (e)(1)(i)(K) of this section, during the same day, the owner or operator shall submit to and receive approval from the Administrator for a site-specific FIP revision. To receive approval, the requirements of USEPA's Emissions Trading Policy Statement (and related policy) must be satisfied.

(E) No owner or operator of a wood furniture coating line subject to the limitations of paragraph (e)(1)(i)(L) of this section shall apply coatings to wood furniture on the subject coating line unless the requirements of paragraph (e)(1)(ii)(E) (1) or (2) of this section, in addition to the requirements specified in the note to paragraph (e)(1)(i)(L) of this section, are met.

(1) For each coating line which applies multiple coatings, all of which are subject to the same numerical emission limitation within paragraph (e)(1)(i)(L) of this section, during the same day (e.g., all coatings used on the line are subject to 0.67 kg/l [5.6 lbs/gal]), the daily-weighted average VOM content shall not exceed the coating VOM content limit corresponding to the category of coating used, or

(2) For each coating line which applies coatings subject to more than one numerical emission limitation in paragraph (e)(1)(i)(L) of this section, during the same day, the owner or operator shall submit to and receive approval from the Administrator for a site-specific FIP revision. To receive approval, the requirements of USEPA's Emissions Trading Policy Statement (and related policy) must be satisfied.

(F) No owner or operator of an existing diesel-electric locomotive coating line in Cook County, subject to the limitations of paragraph (e)(1)(i)(M) of this section shall apply coatings to diesel-electric locomotives on the subject coating line unless the requirements of paragraph (e)(1)(ii)(F) (1) or (2) of this section are met.

(1) For each coating line which applies multiple coatings, all of which are subject to the same numerical emission limitation within paragraph (e)(1)(i)(M) of this section, during the same day (e.g., all coatings used on the line are subject to 0.42 kg/l [3.5 lbs/gal]), the daily-weighted average VOM content shall not exceed the coating VOM content limit corresponding to the category of coating used, or

(2) For each coating line which applies coatings subject to more than one numerical emission limitation in paragraph (e)(1)(i)(M) of this section, during the same day, the owner or operator shall submit to and receive approval from the Administrator for a site-specific FIP revision. To receive approval, the requirements of USEPA's Emissions Trading Policy Statement (and related policy) must be satisfied.

(iii) Limitations in terms of kg (lbs) of VOM emissions per l (gal) of solids as applied at each coating applicator shall be determined by the following equation:

Where: S = The limitation on VOM emissions in terms of kg VOM/l (lbs VOM/gal) of solids, C = The limitation on VOM emissions in terms of kg/l (lbs/gal) of coating (minus water and any compounds which are specifically excluded from the definition of VOM) specified in paragraph (e)(1)(i) of this section, D = The density of VOM in the coating. For the purposes of calculating S, the density is 0.882 kg VOM/l VOM (7.36 lbs VOM/gal VOM).

(2) Alternative emission limitations. Any owner or operator of a coating line subject to paragraph (e)(1) of this section may comply with this paragraph, rather than with paragraph (e)(1) of this section, if a capture system and control device are operated at all times and the owner or operator demonstrates compliance with paragraphs (e)(2) (ii), (iii), (iv), (v), (vi) or (vii) of this section (depending upon the source category) through the applicable coating analysis and capture system and control device efficiency test methods and procedures specified in paragraph (a)(4) of this section and the recordkeeping and reporting requirements specified in paragraph (e)(6)(iv) of this section; and the control device is equipped with the applicable monitoring equipment specified in paragraph (a)(4)(iv) of this section and the monitoring equipment is installed, calibrated, operated and maintained according to vendor specifications at all times the control device is in use. The use of a capture system and control device, which does not demonstrate compliance with paragraph (e)(2) (ii), (iii), (iv), (v), (vi), or (vii), may only be used as an alternative to compliance with paragraph (e)(1) of this section if approved as a FIP revision.

(i) Alternative add-on control methodologies. (A) The coating line is equipped with a capture system and control device that provides 81 percent reduction in the overall emissions of VOM from the coating line and the control device has a 90 percent efficiency, or

(B) The system used to control VOM from the coating line is demonstrated to have an overall efficiency sufficient to limit VOM emissions to no more than what is allowed under paragraph (e)(1) of this section. Use of any control system other than an afterburner, carbon absorption, condensation, or absorption scrubber system can only be allowed if approved by the Administrator as a SIP or FIP revision. Transfer efficiency credits can only be allowed if approved by the Administrator as a SIP or FIP revision. Baseline transfer efficiencies and transfer efficiency test methods must be approved by the Administrator.

Such overall efficiency is to be determined as follows:

(1) Obtain the emission limitation from the appropriate paragraph in (e)(1) of this section,

(2) Calculate “S” according to the equation in paragraph (e)(1)(iii) of this section,

(3) Calculate the overall efficiency required according to paragraph (a)(4)(v) of this section. For the purposes of calculating this value, according to the equation in (a)(4)(v)(B) of this section VOM1 is equal to the value of “S” as determined above in (i)(B)(2).

(ii) No owner or operator of a coating line subject to only one of the emission limitations from among paragraph (e)(1)(i)(A)(1), (e)(1)(i)(A)(2), (e)(1)(i)(A)(4), (e)(1)(i)(C), (e)(1)(i)(D), (e)(1)(i)(E), (e)(1)(i)(F), (e)(1)(i)(G), (e)(1)(i)(H), or (e)(1)(i)(I) of this section and equipped with a capture system and control device shall operate the subject coating line unless the requirements in paragraph (e)(2)(i) (A) or (B) of this section are met. No owner or operator of a coating line subject to paragraph (e)(1)(i)(A)(3) of this section and equipped with a capture system and control device shall operate the coating line unless the owner or operator demonstrates compliance with the topcoat limitation in accordance with the topcoat protocol for automobile or light-duty trucks referenced in paragraph (a)(4)(ii) of this section.

(iii) No owner or operator of a miscellaneous metal parts and products coating line which applies one or more coatings during the same day, all of which are subject to the same numerical emission limitation within paragraph (e)(1)(i)(J) of this section (e.g., all coatings used on the line are subject to 0.42 kg/l [3.5 lbs/gal]), and which is equipped with a capture system and control device shall operate the subject coating line unless the requirements in paragraph (e)(2)(i) (A) or (B) of this section are met.

(iv) No owner or operator of a heavy off-highway vehicle products coating line which applies one or more coatings during the same day, all of which are subject to the same numerical emission limitation within paragraph (e)(1)(i)(K) of this section (e.g., all coatings used on the line are subject to 0.42 kg/l [3.5 lbs/gal]), and which is equipped with a capture system and control device shall operate the subject coating line unless the requirements in paragraph (e)(2)(i) (A) or (B) of this section are met.

(v) No owner or operator of an existing diesel-electric locomotive coating line in Cook County which applies one or more coatings during the same day, all of which are subject to the same numerical emission limitation within paragraph (e)(1)(i)(M) of this section (e.g., all coatings used on the line are subject to 0.42 kg/l [3.5 lbs/gals]), and which is equipped with a capture system and control device shall operate the subject coating line unless the requirements in paragraph (e)(2)(i) (A) or (B) of this section are met.

(vi) No owner or operator of a wood furniture coating line which applies one or more coatings during the same day, all of which are subject to the same numerical emission limitation within paragraph (e)(1)(i)(L) (e.g., all coatings used on the line are subject to 0.67 kg/l [5.6 lbs/gal]), and which is equipped with a capture system and control device shall operate the subject coating line unless the requirements in paragraph (e)(2)(i) (A) or (B) of this section are met. If compliance is achieved by meeting the requirements in paragraph (e)(2)(i)(B) of this section, then the provisions in the note to paragraph (e)(1)(i)(L) of this section must also be met.

(vii) No owner or operator of a can coating facility and equipped with a capture system and control device shall operate the subject coating facility unless the requirements in paragraph (e)(2)(vii) (A) or (B) of this section are met.

(A) An alternative daily emission limitation shall be determined according to paragraph (e)(1)(ii)(C)(2) of this section. Actual daily emissions shall never exceed the alternative daily emission limitation and shall be calculated by use of the following equation:

Where: Ed = Actual VOM emissions for the day in units of kg/day (lbs/day), i = Subscript denoting the specific coating applied, n = Total number of surface coatings as applied in the can coating operation, Vi = Volume of each coating as applied for the day in units of 1/day (gal/day) of coating (minus water and any compounds which are specifically exempted from the definition of VOM), Ci = The VOM content of each coating as applied in units of kg VOM/l (lbs VOM/gal) of coating (minus water and any compounds which are specifically exempted from the definition of VOM), and Fi = Fraction, by weight, of VOM emissions from the surface coating, reduced or prevented from being emitted to the ambient air. This is the overall efficiency of the capture system and control device.

(B) The coating line is equipped with a capture system and control device that provide 75 percent reduction in the overall emissions of VOM from the coating line and the control device has a 90 percent efficiency.

(3) Exemptions from emission limitations—(i) Exemptions for all source categories except wood furniture coating. The limitations of paragraph (e) of this section shall not apply to coating lines within a facility, that otherwise would be subject to the same subparagraph of paragraph (e)(1)(i) of this section (because they belong to the same source category, e.g. can coating), provided that combined actual emissions of VOM from all lines at the facility subject to that subparagraph never exceed 6.8 kg/day (15 lbs/day) before the application of capture systems and control devices. (For example, can coating lines within a plant would not be subject to the limitations of subparagraph (e)(1)(i)(B) of this section if the combined actual emissions of VOM from the can coating lines never exceed 6.8 kg/day (15 lbs/day) before the application of capture systems and control devices.) Volatile organic material emissions from heavy off-highway vehicle products coating lines must be combined with VOM emissions from miscellaneous metal parts and products coating lines to determine applicability. Any owner or operator of a coating facility shall comply with the applicable coating analysis test methods and procedures specified in paragraph (a)(4)(i) of this section and the recordkeeping and reporting requirements specified in paragraph (e)(6)(i) of this section if total VOM emissions from the subject coating lines are always less than or equal to 6.8 kg/day (15 lbs/day) before the application of capture systems and control devices and, therefore, are not subject to the limitations of paragraph (e)(1) of this section. Once a category of coating lines at a facility is subject to the limitations in paragraph (e)(1) of this section, the coating lines are always subject to the limitations in paragraph (e)(1) of this section.

(ii) Applicability for wood furniture coating. (A) The limitations of paragraph (e) of this section shall apply to a plant's wood furniture coating lines if the plant contains process emission sources, not regulated by paragraphs (d), (e) (excluding paragraph (e)(1)(i)(L)), (h) (excluding paragraph (h)(5)), (i), (j), or (q)(1), or subparts B, Q (excluding sections 215.432 and 215.436), R (excluding sections 215.447, 215.450, and 215.452), S, V, X, Y (sections 215.582-215.584), or Z of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), which as a group both:

(1) Have maximum theoretical emissions of 91 Mg (100 tons) or more per calendar year of VOM if no air pollution control equipment were used, and

(2) Are not limited to less than 91 Mg (100 tons) of VOM per calendar year if no air pollution control equipment were used, through production or capacity limitations contained in a federally enforceable construction permit or SIP or FIP version.

(B) If a plant ceases to fulfill the criteria of paragraph (e)(3)(ii)(A) of this section, the limitations of paragraph (e)(1)(i)(L) of this section shall continue to apply to any wood furniture coating line which was ever subject to the limitations of paragraph (e)(1)(i)(L) of this section.

(C) For the purposes of paragraph (e)(3)(ii) of this section, an emission source shall be considered regulated by a subpart (of the Illinois rules), section, or paragraph if it is subject to the limitations of that subpart (of the Illinois rules), section, or paragraph. An emission source is not considered regulated by a subpart (of the Illinois rules), section, or paragraph if its emissions are below the applicability cutoff level or if the source is covered by an exemption.

(D) Any owner or operator of a wood furniture coating line to which the limitations of paragraph (e) of this section are not applicable due to the criteria in paragraph (e)(3)(ii) of this section shall, upon request by the Administrator, submit records to the Administrator within 30 calendar days from the date of the request that document that the coating line is exempt from the limitations of paragraph (e) of this section.

(4) Exemption from general rule on use of organic material. No owner or operator of a coating line subject to the limitations of paragraph (e)(1) of this section is required to meet the limitations of subpart K (section 215.301 or 215.302) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), after the date by which the coating line is required to meet paragraph (e)(1) of this section.

(5) Compliance schedule. Except as specified in paragraph (e)(7) of this section, every owner or operator of a coating line (of a type included within paragraph (e)(1)(i) of this section) shall comply with the requirements of paragraph (e)(1),(e)(2) or (e)(3) of this section and paragraph (e)(6) of this section in accordance with the appropriate compliance schedule as specified in paragraph (e)(5)(i),(ii),(iii) or (iv) of this section.

(i) No owner or operator of a coating line which is exempt from the limitations of paragraph (e)(1) of this section because of the criteria in paragraph (e)(3)(i) of this section shall operate said coating line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraph (e)(6)(i) of this section. Wood furniture coating lines are not subject to paragraph (e)(6)(i) of this section.

(ii) No owner or operator of a coating line complying by means of paragraph (e)(1)(i) of this section shall operate said coating line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraphs (e)(1)(i) and (e)(6)(ii) of this section.

(iii) No owner or operator of a coating line complying by means of paragraph (e)(1)(ii) of this section shall operate said coating line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraphs (e)(1)(ii) and (e)(6)(iii) of this section.

(iv) No owner or operator of a coating line complying by means of paragraph (e)(2) of this section shall operate said coating line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraphs (e)(2) and (e)(6)(iv) of this section.

(6) Recordkeeping and reporting. The VOM content of each coating and the efficiency of each capture system and control device shall be determined by the applicable test methods and procedures specified in paragraph (a)(4) of this section to establish the records required under paragraph (e)(6) of this section.

(i) Any owner or operator of a coating line which is exempted from the limitations of paragraph (e)(1) of this section because of paragraph (e)(3)(i) of this section shall comply with the following:

(A) By July 1, 1991, the owner or operator of a facility referenced in paragraph (e)(6)(i) of this section shall certify to the Administrator that the facility is exempt under the provisions of paragraph (e)(3)(i) of this section. Such certification shall include:

(1) A declaration that the facility is exempt from the limitations of paragraph (e)(1) of this section because of paragraph (e)(3)(i) of this section; and

(2) Calculations which demonstrate that the combined VOM emissions from all coating lines at the facility never exceed 6.8 kg (15 lbs) per day before the application of capture systems and control devices. The following equation shall be used to calculate total VOM emissions:

Where: Te = Total VOM emissions from coating lines at a facility each day before the application of capture systems and control devices in units of kg/day (lbs/day), m = Number of coating lines at the facility, j = Subscript denoting an individual coating line, n = Number of different coatings as applied each day on each coating line at the facility, i = Subscript denoting an individual coating, Ai = Weight of VOM per volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line at the facility in units of kg VOM/l (lbs VOM/gal), and Bi = Volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line at the facility in units of l/day (gal/day). The instrument or method by which the owner or operator accurately measured or calculated the volume of each coating as applied on each coating line each day shall be described in the certification to the Administrator.

(B) On and after July 1, 1991, the owner or operator of a facility referenced in paragraph (e)(6)(i) of this section shall collect and record all of the following information each day for each coating line and maintain the information at the facility for a period of three years:

(1) The name and identification number of each coating as applied on each coating line.

(2) The weight of VOM per volume and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line.

(C) On and after July 1, 1991, the owner or operator of a facility exempted from the limitations of paragraph (e)(1) of this section because of paragraph (e)(3)(i) of this section shall notify the Administrator of any record showing that total VOM emissions from the coating facility exceed 6.8 kg (15 lbs) in any day before the application of capture systems and control devices shall be reported by sending a copy of such record to the Administrator within 30 days after the exceedance occurs.

(ii) Any owner or operator of a coating line subject to the limitations of paragraph (e)(1) of this section and complying by means of paragraph (e)(1)(i) of this section shall comply with the following:

(A) By July 1, 1991, or upon initial start-up of a new coating line, or upon changing the method of compliance from an existing subject coating line from paragraph (e)(1)(ii) or paragraph (e)(2) to paragraph (e)(1)(i) of this section; the owner or operator of a subject coating line shall certify to the Administrator that the coating line will be in compliance with paragraph (e)(1)(i) of this section on and after July 1, 1991, or on and after the initial start-up date. Such certification shall include:

(1) The name and identification number of each coating as applied on each coating line.

(2) The weight of VOM per volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line.

(3) For coating lines subject to paragraph (e)(1)(i)(A)(3) of this section, certification shall include:

(i) The name and identification number of each coating line which will comply by means of paragraph (e)(1)(i)(A)(3) of this section,

(ii) The name and identification number of each coating as applied on each coating line,

(iii) The weight of VOM per volume of each coating as applied on each coating line,

(iv) The instrument or method by which the owner or operator will accurately measure or calculate the volume of each coating as applied each day on each coating line,

(v) The method by which the owner or operator will create and maintain records each day as required in paragraph (e)(6)(ii)(B) of this section for coating lines subject to paragraph (e)(1)(i)(A)(3) of this section,

(vi) An example format in which the records required in paragraph (e)(6)(ii)(B) of this section for coating lines subject to paragraph (e)(1)(i)(A)(3) of this section.

(B) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a coating line subject to the limitations of paragraph (e)(1) of this section and complying by means of paragraph (e)(1)(i) of this section shall collect and record all of the following information each day for each coating line and maintain the information at the facility for a period of three years:

(1) The name and identification number of each coating as applied on each coating line.

(2) The weight of VOM per volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line.

(3) For coating lines subject to paragraph (e)(1)(i)(A)(3) of this section, the owner or operator shall maintain all records necessary to calculate the daily-weighted average VOM content from the coating line in accordance with the proposal submitted, and approved by the Administrator, pursuant to paragraph (e)(1)(A)(3) of this section.

(C) On and after July 1, 1991, the owner or operator of a subject coating line shall notify the Administrator in the following instances:

(1) Any record showing violation of paragraph (e)(1)(i) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation, except that any record showing a violation of paragraph (e)(1)(i)(A)(3) of this section shall be reported by sending a copy of such record to the Administrator within 15 days from the end of the month in which the violation occurred.

(2) At least 30 calendar days before changing the method of compliance with paragraph (e)(1) of this section from paragraph (e)(1)(i) to paragraph (e)(1)(ii) or paragraph (e)(2) of this section, the owner or operator shall comply with all requirements of paragraph (e)(6) (iii)(A) or (iv)(A) of this section, respectively. Upon changing the method of compliance with paragraph (e)(1) of this section from paragraph (e)(1)(i) to paragraph (e)(1)(ii) or paragraph (e)(2) of this section, the owner or operator shall comply with all requirements of paragraph (e)(6) (iii) or (iv) of this section, respectively.

(3) For coating lines subject to paragraph (e)(1)(i)(A)(3) of this section, the owner or operator shall notify the Administrator of any change to the topcoating operation at least 30 days before the change is effected. The Administrator shall determine whether or not recertification testing is required. If the Administrator determines that recertification testing is required, then the owner or operator shall submit a proposal to the Administrator to test within 30 days and retest within 30 days of the Administrator's approval of the proposal.

(iii) Any owner or operator of a coating line subject to the limitations of paragraph (e)(1) of this section and complying by means of paragraph (e)(1)(ii) of this section shall comply with the following:

(A) By July 1, 1991, or upon initial start-up of a new coating line, or upon changing the method of compliance for an existing subject coating line from paragraph (e)(1)(i) or paragraph (e)(2) to paragraph (e)(1)(ii) of this section; the owner or operator of the subject coating line shall certify to the Administrator that the coating line will be in compliance with paragraph (e)(1)(ii) of this section on and after July 1, 1991, or on and after the initial start-up date. Such certification shall include:

(1) The name and identification number of each coating line which will comply by means of paragraph (e)(1)(ii) of this section.

(2) The name and identification number of each coating as applied on each coating line.

(3) The weight of VOM per volume and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line.

(4) The instrument or method by which the owner or operator will accurately measure or calculate the volume of each coating as applied each day on each coating line.

(5) The method by which the owner or operator will create and maintain records each day as required in paragraph (e)(6)(iii)(B) of this section.

(6) An example of the format in which the records required in paragraph (e)(6)(iii)(B) of this section will be kept.

(B) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a coating line subject to the limitations of paragraph (e)(1) of this section and complying by means of paragraph (e)(1)(ii) of this section, shall collect and record all of the following information each day for each coating line and maintain the information at the facility for a period of three years:

(1) The name and identification number of each coating as applied on each coating line.

(2) The weight of VOM per volume and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line.

(3) The daily-weighted average VOM content of all coatings as applied on each coating line as defined in paragraph (a)(3) of this section.

(C) On and after July 1, 1991, the owner or operator of a subject coating line shall notify the Administrator in the following instances:

(1) Any record showing violation of paragraph (e)(1)(ii) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(2) At least 30 calendar days before changing the method of compliance with paragraph (e) from paragraph (e)(1)(ii) to paragraph (e)(1)(i) or paragraph (e)(2) of this section, the owner or operator shall comply with all requirements of paragraph (e)(6)(ii)(A) or (iv)(A), respectively. Upon changing the method of compliance with paragraph (e) from paragraph (e)(1)(ii) to paragraph (e)(1)(i) or paragraph (e)(2) of this section, the owner or operator shall comply with all requirements of paragraph (e)(6)(ii) or (iv), respectively.

(iv) Any operator or owner of a coating line subject to the limitations of paragraph (e)(2) of this section and complying by means of paragraph (e)(2)(ii), (iii), (iv), (v), (vi) or (vii) of this section shall comply with the following:

(A) By July 1, 1991, or upon initial start-up of a new coating line, or upon changing the method of compliance for an existing coating line from paragraph (e)(1) (i) or (ii) to paragraph (e)(2) of this section; the owner or operator of the subject coating line shall perform all tests and submit to the Administrator the results of all tests and calculations necessary to demonstrate that the subject coating line will be in compliance with paragraph (e)(2) of this section on and after July 1, 1991, or on and after the initial start-up date.

(B) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a coating line subject to the limitations of paragraph (e)(2) of this section and complying by means of paragraph (e)(2) (ii), (iii), (iv), (v), (vi) or (vii) of this section shall collect and record all of the following information each day for each coating line and maintain the information at the facility for a period of three years:

(1) The weight of VOM per volume of coating solids as applied each day on each coating line, if complying pursuant to paragraph (e)(2)(i)(B) of this section.

(2) Control device monitoring data.

(3) A log operating time for the capture system, control device, monitoring equipment and the associated coating line.

(4) A maintenance log for the capture system, control device and monitoring equipment detailing all routine and non-routine maintenance performed including dates and duration of any outages.

(C) On and after July 1, 1991, the owner or operator of a subject coating line shall notify the Administrator in the following instances:

(1) Any record showing violation of paragraph (e)(2) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(2) At least 30 calendar days before changing the method of compliance with paragraph (e) from paragraph (e)(2) to paragraph (e)(1)(i) or paragraph (e)(1)(ii) of this section, the owner or operator shall comply with all requirements of paragraph (e)(6)(ii)(A) or (iii)(A) of this section, respectively. Upon changing the method of compliance with paragraph (e) from paragraph (e)(2) to paragraph (e)(1)(i) or paragraph (e)(1)(ii) of this section, the owner or operator shall comply with all requirements of paragraph (e)(6)(ii) or (iii) of this section, respectively.

(7) Compliance schedule for diesel electric locomotive coatings. Notwithstanding any other provision of this subpart, the compliance date for the emission limitations and standards for “topcoat” and “final repair coat” operations only as applied to General Motors Corporation at their diesel electric locomotive coating lines in Cook County, Illinois, codified at 40 Cspan 52.741(e)(1)(i)(M) (2) and (3) is specified in this paragraph (e)(7). Compliance with the requirements of paragraph (e)(1), (e)(2) or (e)(3) of this section and paragraph (e)(6) of this section must be in accordance with the appropriate compliance schedule as specified in paragraph (e)(7)(i),(ii),(iii), or (iv) of this section.

(i) No owner or operator of a coating line which is exempt from the limitations of paragraph (e)(1) of this section because of the criteria in paragraph (e)(3)(i) of this section shall operate said coating line on or after March 25, 1995, unless the owner or operator has complied with, and continues to comply with, paragraph (e)(6)(i) of this section.

(ii) No owner or operator of a coating line complying by means of paragraph (e)(1)(i) of this section shall operate said coating line on or after March 25, 1995, unless the owner or operator has complied with, and continues to comply with, paragraph (e)(1)(i) and (e)(6)(ii) of this section.

(iii) No owner or operator of a coating line complying by means of paragraph (e)(1)(ii) of this section shall operate said coating line on or after March 25, 1995, unless the owner or operator has complied with, and continues to comply with, paragraphs (e)(1)(ii) and (e)(6)(iii) of this section.

(iv) No owner or operator of a coating line complying by means of paragraph (e)(2) of this section shall operate said coating line on or after March 25, 1995, unless the owner or operator has complied with, and continues to comply with, paragraphs (e)(2) and (e)(6)(iv) of this section.

(8) The control requirements in this paragraph apply to the wood coating line, which coats wooden globe stand components, at Replogle Globes, Inc. (Replogle) Broadview facility in Cook County, Illinois, instead of the control requirements in paragraphs (e)(1) and (e)(2) of this section. Compliance with this paragraph must be demonstrated through the applicable coating analysis test methods and procedures specified in paragraph (a)(4)(i) of this section.

(i) After October 6, 1991, no coatings shall at any time be applied which exceed the following emission limitations for the specified coating.

(A) 6.59 pounds (lbs) Volatile Organic Material (VOM) per gallon of stain (minus water and any compounds which are specifically exempted from the definition of VOM) as applied to coat wooden globe stand components. Such stain consists of #9250 Walnut NGR Stain (RGI # W06000100), #9974 Cherry NGR Stain (RGI # W06003500) and #9943 Ash NGR Stain (RGI # W06003600). The Administrator must be notified at least ten (10) days prior to the use of any replacement stains.

(B) 5.53 lbs VOM per gallon of Sanding Sealer (minus water and any compounds which are specifically exempted from the definition of VOM) as applied to coat wooden globe stand components. Such sealer consists of #15304 High Build Sanding Sealer (RGI # W06003700). The Administrator must be notified at least ten (10) days prior to the use of any replacement sanding sealer.

(C) 5.20 lbs VOM per gallon of lacquer (minus water and any compounds which are specifically exempted from the definition of VOM) as applied to coat wooden globe stand components. Such lacquer consists of #15352 High Build Lacquer (RGI # W06003300). The Administrator shall be notified at least ten (10) days prior to the use of any replacement lacquer.

(ii) After October 6, 1991, the volume of coatings used shall not exceed the following:

(A) 5,000 gallons per year total for all coatings specified in paragraph (e)(8)(i)(A) of this section. The yearly volume of coatings used are to be calculated as follows:

(1) Compute the volume of specified coating used each month by the 15th of the following month.

(2) By the 15th of each month, add the monthly coating use for the 12 previous months (to obtain the yearly volume of coatings used).

(B) 4,000 gallons per year total for all coatings specified in paragraph (e)(8)(i)(B) of this section. The yearly volume of the coatings used are to be calculated as specified in paragraphs (e)(8)(ii)(A)(1) and (e)(8)(ii)(A)(2) of this section.

(C) 5,000 gallons per year total for all coatings specified in paragraph (e)(8)(i)(C) of this section. The yearly volume of coatings used are to be calculated as specified in paragraphs (e)(8)(ii)(A)(1) and (e)(8)(ii)(A)(2) of this section.

(iii) Beginning on October 6, 1991, the owner and operator of the Replogle Globes, Inc. plant in Broadview, Illinois shall keep the following records for each month. All records shall be retained at Replogle Globes, Inc. for three (3) years and shall be made available to the Administrator on request.

(A) the name and identification number of each coating as applied on any wood coating line.

(B) The weight of VOM per volume (determined in accordance with the procedures in paragraph (a)(4)(i) of this section) and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each month on any wood coating line.

(9) [Reserved]

(10) Until December 31, 1996, the control and recordkeeping requirements in this paragraph apply to the three solvent-based polyester paper coating lines (Lines C, D and E) at Riverside Laboratories' Kane County, Illinois facility, instead of the control requirements in paragraphs (e)(1) and (e)(2) of this section and the recordkeeping requirements in paragraph (e)(6) of this section. Compliance with this paragraph must be demonstrated through the applicable coating analysis test methods and procedures specified in paragraph (a)(4)(i) of this section. The requirements in paragraphs (e)(1), (e)(2), and (e)(6) of this section shall apply to Riverside on and after December 31, 1996.

(i) After December 21, 1995, no coatings shall at any time be applied on Lines C, D or E which exceed 3.5 pounds (lbs.) volatile organic material (VOM) per gallon of coating (minus water and any compounds which are specifically exempted from the definition of VOM), except as provided in paragraph (e)(10)(ii) of this section.

(ii) After December 21, 1995, the following specifically identified coatings may exceed 3.5 lbs. VOM per gallon of coating (minus water and any compounds which are specifically exempted from the definition of VOM) only if they are applied on Line E and they do not exceed the limits indicated below (minus water and any compounds which are specifically exempted from the definition of VOM):

EXP-5027—4.34 lbs./gallon PD 75 CLR—4.19 lbs./gallon PD 75 BRN—4.18 lbs./gallon SQZ-54—3.88 lbs./gallon SPX-34GL—3.51 lbs./gallon

(iii) That portion of Riverside's polyester production which is manufactured with the use of any VOC, from Lines C, D, and E, may not exceed the following levels: 35 million square feet per year during and after 1992, 29 million square feet per year during and after 1994, and 25 million square feet during 1996. Compliance with this requirement shall be determined by adding the polyester production from any 12 consecutive months during and after the years indicated, through 1996. That is, the polyester production for any 12 consecutive months starting with January 1992 cannot exceed 35 million square feet; the polyester production from any 12 consecutive months starting with January 1994 cannot exceed 29 million square feet; and the polyester production for the twelve months from January through December 1996 cannot exceed 25 million square feet. Only those square feet of polyester whose production involves the use of VOC need to be restricted by the production levels in this paragraph (e)(10)(iii) of this section.

(iv) By December 21, 1995, Riverside shall certify to the Administrator that its polyester coating operations will be in compliance with paragraphs (e)(10)(i), (e)(10)(ii), and (e)(10)(iii) of this section. Such certification shall include the following:

(A) The name and identification number of each coating as applied on coating lines C, D and E.

(B) The weight of VOM per volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied on each coating line.

(v) The Administrator must be notified at least 10 days prior to the use of any polyester coating not previously identified pursuant to paragraph (e)(10)(iv) of this section. This notification must include the information specified in paragraphs (e)(10)(iv)(A) and (e)(10)(iv)(B) of this section.

(vi) On and after December 21, 1995, Riverside shall collect and record all of the following information each day for each coating and maintain the information at the facility for a period of 3 years:

(A) The name and identification number of each coating as applied.

(B) The weight of VOM per volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day.

(C) Any record showing a VOM content in excess of the emission limits in paragraph (e)(10)(i) or (e)(10)(ii) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following its collection.

(D) Any VOM besides acetone used in any coating must be identified.

(vii) Starting with the first full month after December 21, 1995, Riverside shall collect and record the figures on polyester production (in square feet), for each month and maintain the information at the facility for a period of at least 3 years.

(viii) Regardless of any other provision of paragraph (e)(10) of this section, after August 21, 1995 no coating which contains any VOM other than acetone shall at any time be applied on Line C, D, or E which exceeds 2.9 lbs. VOM per gallon of coating (minus water and any compounds which are specifically exempted from the definition of VOM).

(f)-(g) [Reserved]

(h) Printing and publishing—(1) Flexographic and rotogravure printing. (i) No owner or operator of a subject flexographic, packaging rotogravure or publication rotogravure printing line shall apply at any time any coating or ink unless the VOM content does not exceed the limitation specified in either paragraph (h)(1)(i)(A) or (B) of this section. Compliance with this paragraph must be demonstrated through the applicable coating or ink analysis test methods and procedures specified in paragraph (a)(4)(i) of this section and the recordkeeping and reporting requirements specified in paragraph (h)(4)(ii) of this section. As an alternative to compliance with paragraph (h)(1)(i) of this section, a subject printing line may meet the requirements of paragraph (h)(1)(ii) or (iii) of this section.

(A) Forty percent VOM by volume of the coating and ink (minus water and any compounds which are specifically exempted from the definition of VOM), or

(B) Twenty-five percent VOM by volume of the volatile content in the coating and ink.

(ii) No owner or operator of a subject flexographic, packaging rotogravure or publication rotogravure printing line shall apply coatings or inks on the subject printing line unless the weighted average, by volume, VOM content of all coatings and inks as applied each day on the subject printing line does not exceed the limitation specified in either paragraph (h)(1)(i)(A) (as determined by paragraph (h)(1)(ii)(A) or (h)(1)(i)(B) (as determined by paragraph (h)(1)(ii)(B) of this section. Compliance with this paragraph must be demonstrated through the applicable coating or ink analysis test methods and procedures specified in paragraph (a)(4)(i) of this section and the recordkeeping and reporting requirements specified in paragraph (h)(4)(iii) of this section.

(A) The following equation shall be used to determine if the weighted average VOM content of all coatings and inks as applied each day on the subject printing line exceeds the limitation specified in paragraph (h)(1)(i)(A) of this section.

Where: VOM(i)(A) = The weighted average VOM content in units of percent VOM by volume of all coatings and inks (minus water and any compounds which are specifically exempted from the definition of VOM) used each day, i = Subscript denoting a specific coating or ink as applied, n = The number of different coatings and/or inks as applied each day on a printing line, Ci = The VOM content in units of percent VOM by volume of each coating or ink as applied (minus water and any compounds which are specifically exempted from the definition of VOM), Li = The liquid volume of each coating or ink as applied in units of l (gal), Vsi = The volume fraction of solids in each coating or ink as applied, and VVOMi = The volume fraction of VOM in each coating or ink as applied.

(B) The following equation shall be used to determine if the weighted average VOM content of all coatings and inks as applied each day on the subject printing line exceeds the limitation specified in paragraph (h)(1)(i)(B) of this section.

Where: VOM(i)(B) = The weighted average VOM content in units of percent VOM by volume of the volatile content of all coatings and inks used each day, i = Subscript denoting a specific coating or ink as applied, n = The number of different coatings and/or inks as applied each day on each printing line, Ci = The VOM content in units of percent VOM by volume of the volatile matter in each coating or ink as applied, Li = The liquid volume of each coating or ink as applied in units of l (gal), and VVMi = The volume fraction of volatile matter in each coating or ink as applied.

(iii) No owner or operator of a subject flexographic, packaging rotogravure or publication rotogravure printing line equipped with a capture system and control device shall operate the subject printing line unless the owner or operator meets the requirements in paragraph (h)(1)(iii) (A), (B) or (C) and paragraphs (h)(1)(iii) (D), (E) and (F) of this section.

(A) A carbon adsorption system is used which reduces the captured VOM emissions by at least 90 percent by weight, or

(B) An incineration system is used which reduces the captured VOM emissions by at least 90 percent by weight, or

(C) An alternative VOM emission reduction system is demonstrated to have at least a 90 percent control device efficiency and the alternative emission reduction system is approved by the Administrator as a SIP or FIP revisions, and

(D) The printing line is equipped with a capture system and control device that provides an overall reduction in VOM emissions of at least:

(1) 75 percent where a publication rotogravure printing line is employed, or

(2) 65 percent where a packaging rotogravure printing line is employed, or

(3) 60 percent where a flexographic printing line is employed, and

(E) The control device is equipped with the applicable monitoring equipment specified in paragraph (a)(4)(iv)(B) of this section and the monitoring equipment is installed, calibrated, operated and maintained according to vendor specifications at all times the control device is in use, and

(F) The capture system and control device are operated at all times when the subject printing line is in operation. The owner or operator shall demonstrate compliance with this paragraph by using the applicable capture system and control device test methods and procedures specified in paragraphs (a)(4) (iii) through (vi) of this section and by complying with the recordkeeping and reporting requirements specified in paragraph (h)(4)(iv) of this section.

(2) Applicability. (i) The limitations of paragraph (h)(1) of this section apply to all flexographic and rotogravure printing lines at a subject facility. All facilities with flexographic and/or rotogravure printing lines are subject facilities unless:

(A) Total maximum theoretical emissions of VOM from all flexographic and rotogravure printing line(s) at the facility never exceed 90.7 Mg (100 tons) per calendar year before the application of capture systems and control devices, or

(B) A federally enforceable construction permit or SIP or FIP revision for all flexographic and rotogravure printing line(s) at a facility requires the owner or operator to limit production or capacity of these printing line(s) to reduce total VOM emissions from all flexographic and rotogravure printing line(s) to 90.7 Mg (100 tons) or less per calendar year before the application of capture systems and control devices.

(ii) Upon achieving compliance with paragraph (h) of this section, the emission source is not required to meet subpart K (sections 215.301 or 215.302) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742). Emission sources exempt from paragraph (h) of this section are subject to subpart K (sections 215.301 or 215.302). Rotogravure or flexographic equipment used for both roll printing and paper coating are subject to paragraph (h) of this section.

(iii) Once subject to the limitations of paragraph (h)(1) of this section, a flexographic or rotogravure printing line is always subject to the limitations of paragraph (h)(1) of this section.

(iv) Any owner or operator of any flexographic or rotogravure printing line that is exempt from the limitations of paragraph (h)(1) of this section because of the criteria in paragraph (h)(2) of this section is subject to the recordkeeping and reporting requirements specified in paragraph (h)(4)(i) of this section.

(3) Compliance schedule. Every owner or operator of a flexographic and/or rotogravure printing line shall comply with the applicable requirements of paragraph (h)(1) of this section and paragraph (h)(4) of this section in accordance with the applicable compliance schedule specified in paragraph (h)(3) (i), (ii), (iii) or (iv) of this section.

(i) No owner or operator of a flexographic or rotogravure printing line which is exempt from the limitations of paragraph (h)(1) of this section because the criteria in paragraph (h)(2) of this section shall operate said printing line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraph (h)(4)(i) of this section.

(ii) No owner or operator of a flexographic or rotogravure printing line complying by means of paragraph (h)(1)(i) of this section shall operate said printing line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraphs (h)(1)(i) and (h)(4)(ii) of this section.

(iii) No owner or operator of a flexographic or rotogravure printing line complying by means of paragraph (h)(1)(ii) of this section shall operate said printing line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraphs (h)(1)(ii) and (h)(4)(iii) of this section.

(iv) No owner or operator of a flexographic or rotogravure printing line complying by means of paragraph (h)(1)(iii) of this section shall operate said printing line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraphs (h)(1)(iii) and (h)(4)(iv) of this section.

(4) Recordkeeping and reporting. The VOM content of each coating and ink and the efficiency of each capture system and control device shall be determined by the applicable test methods and procedures specified in paragraph (a)(4) of this section to establish the records required under paragraph (h)(4) of this section.

(i) Any owner or operator of a printing line which is exempted from the limitations of paragraph (h)(1) of this section because of the criteria in paragraph (h)(2) of this section shall comply with the following:

(A) By July 1, 1991, the owner or operator of a facility to which paragraph (h)(4)(i) of this section is applicable shall certify to the Administrator that the facility is exempt under the provisions of paragraph (h)(2) of this section. Such certification shall include:

(1) A declaration that the facility is exempt from the limitations of the criteria in paragraph (h)(1) of this section because of paragraph (h)(2) of this section, and

(2) Calculations which demonstrate that total maximum theoretical emissions of VOM from all flexographic and rotogravure printing lines at the facility never exceed 90.7 Mg (100 tons) per calendar year before the application of capture systems and control devices. Total maximum theoretical emissions of VOM for a flexograhpic or rotogravure printing facility is the sum of maximum theoretical emissions of VOM from each flexographic and rotogravure printing line at the facility. The following equation shall be used to calculate total maximum theoretical emissions of VOM per calendar year before the application of capture systems and control devices for each flexographic and rotogravure printing line at the facility:

Ep = A × B Where: Ep = Total maximum theoretical emissions of VOM from one flexographic or rotogravure printing line in units of kg/year (lbs/year), A = Weight of VOM per volume of solids of the coating or ink with the highest VOM content as applied each year on the printing line in units of kg VOM/l (lbs VOM/gal) of coating or ink solids, and B = Total volume of solids for all coatings and inks that can potentially be applied each year on the printing line in units of l/year (gal/year). The instrument and/or method by which the owner or operator accurately measured or calculated the volume of each coating and ink as applied and the amount that can potentially be applied each year on the printing line shall be described in the certification to the Administrator.

(B) On and after July 1, 1991, the owner or operator of a facility referenced in paragraph (h)(4)(i) of this section shall collect and record all of the following information each year for each printing line and maintain the information at the facility for a period of three years:

(1) The name and identification number of each coating and ink as applied on each printing line.

(2) The VOM content and the volume of each coating and ink as applied each year on each printing line.

(C) On and after July 1, 1991, the owner or operator of a facility exempted from the limitations of paragraph (h)(1) of this section because of the criteria in paragraph (h)(2) of this section shall notify the Administrator of any record showing that total maximum theoretical emissions of VOM from all printing lines exceed 90.7 Mg (100 tons) in any calendar year before the application of capture systems and control devices, shall be reported by sending a copy of such record to the Administrator within 30 days after the exceedance occurs.

(ii) Any owner or operator of a printing line subject to the limitations of paragraph (h)(1) of this section and complying by means of paragraph (h)(1)(i) of this section shall comply with the following:

(A) By July 1, 1991, or upon initial start-up of a new printing line, or upon changing the method of compliance from an existing subject printing line from paragraph (h)(1) (ii) or (iii) of this section to paragraph (h)(1)(i) of this section, the owner or operator of a subject printing line shall certify to the Administrator that the printing line will be in compliance with paragraph (h)(1)(i) of this section on and after July 1, 1991, or on and after the initial start-up date. Such certification shall include:

(1) The name and identification number of each coating and ink as applied on each printing line.

(2) The VOM content of each coating and ink as applied each day on each printing line.

(B) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a printing line subject to the limitations of paragraph (h)(1) of this section and complying by means of paragraph (h)(1)(i) of this section shall collect and record all of the following information each day for each coating line and maintain the information at the facility for a period of three years:

(1) The name and identification number of each coating and ink as applied on each printing line.

(2) The VOM content of each coating and ink as applied each day on each printing line.

(C) On and after July 1, 1991, the owner or operator of a subject printing line shall notify the Administrator in the following instances:

(1) Any record showing violation of paragraph (h)(1)(i) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(2) At least 30 calendar days before changing the method of compliance with paragraph (h)(1) of this section from paragraph (h)(1)(i) of this section to paragraph (h)(1) (ii) or (iii) of this section, the owner or operator shall comply with all requirements of paragraph (h)(4) (iii)(A) or (iv)(A) of this section respectively. Upon changing the method of compliance with paragraph (h)(1) from paragraph (h)(1)(i) to paragraph (h)(1) (ii) or (iii) of this section, the owner or operator shall comply with all requirements of paragraph (h)(4) (iii) or (iv) of this section, respectively.

(iii) Any owner or operator of a printing line subject to the limitations of paragraph (h)(1) of this section and complying by means of paragraph (h)(1)(ii) of this section shall comply with the following:

(A) By July 1, 1991, or upon initial start-up of a new printing line, or upon changing the method of compliance for an existing subject printing line from paragraph (h)(1) (i) or (iii) of this section to paragraph (h)(1)(ii) of this section, the owner or operator of the subject printing line shall certify to the Administrator that the printing line will be in compliance with paragraph (h)(1)(ii) of this section on and after July 1, 1991, or on and after the initial start-up date. Such certification shall include:

(1) The name and identification number of each printing line which will comply by means of paragraph (h)(1)(ii) of this section.

(2) The name and identification number of each coating and ink available for use on each printing line.

(3) The VOM content of each coating and ink as applied each day on each printing line.

(4) The instrument or method by which the owner or operator will accurately measure or calculate the volume of each coating and ink as applied each day on each printing line.

(5) The method by which the owner or operator will create and maintain records each day as required in paragraph (h)(4)(iii)(B) of this section.

(6) An example of the format in which the records required in paragraph (h)(4)(iii)(B) of this section will be kept.

(B) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a printing line subject to the limitations of paragraph (h)(1) of this section and complying by means of paragraph (h)(1)(ii) of this section shall collecting line and maintain the information at the facility for a period of three years:

(1) The name and identification number of each coating and ink as applied on each printing line.

(2) The VOM content and the volume of each coating and ink as applied each day on each printing line.

(3) The daily-weighted average VOM content of all coatings and inks as applied on each printing line.

(C) On and after July 1, 1991, the owner or operator of a subject printing line shall notify the Administrator in the following instances:

(1) Any record showing violation of paragraph (h)(1)(ii) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(2) At least 30 calendar days before changing the method of compliance with paragraph (h)(1) of this section from paragraph (h)(1)(ii) to paragraph (h)(1)(i) or (iii) of this section, the owner or operator shall comply with all requirements of paragraph (h)(4)(ii)(A) or (iv)(A), respectively. Upon changing the method of compliance with paragraph (h)(1) from paragraph (h)(1)(ii) to paragraph (h)(1)(i) or (iii), the owner or operator shall comply with all requirements of paragraph (h)(4)(ii) or (iv) of this section, respectively.

(iv) Any owner or operator of a printing line subject to the limitations of paragraph (h)(1) of this section and complying by means of paragraph (h)(1)(iii) of this section shall comply with the following:

(A) By July 1, 1991, or upon initial start-up of a new printing line, or upon changing the method of compliance for an existing printing line from paragraph (h)(1)(i) or (ii) of this section to paragraph (h)(1)(iii) of this section, the owner or operator of the subject printing line shall perform all tests and submit to the Administrator the results of all tests and calculations necessary to demonstrate that the subject printing line will be in compliance with paragraph (h)(1)(iii) of this section on and after July 1, 1991, or on and after the initial start-up date.

(B) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a printing line subject to the limitations of paragraph (h)(1) of this section and complying by means of paragraph (h)(1)(iii) of this section shall collect and record all of the following information each day for each printing line and maintain the information at the facility for a period of three years:

(1) Control device monitoring data.

(2) A log of operating time for the capture system, control device, monitoring equipment and the associated printing line.

(3) A maintenance log for the capture system, control device and monitoring equipment detailing all routine and non-routine maintenance performed including dates and duration of any outages.

(C) On and after July 1, 1991, the owner or operator of a subject printing line shall notify the Administration in the following instances:

(1) Any record showing violation of paragraph (h)(1)(iii) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(2) At least 30 calendar days before changing the method of compliance with paragraph (h)(1) from paragraph (h)(1)(iii) to paragraph (h)(1) (i) or (ii), the owner or operator shall comply with all requirements of paragraph (h)(4) (ii)(A) or (iii)(A) of this section, respectively. Upon changing the method of compliance with paragraph (h)(1) from paragraph (h)(1)(iii) to paragraph (h)(1) (i) or (ii) of this section, the owner or operator shall comply with all requirements of paragraph (h)(4) (ii) or (iii) of this section, respectively.

(5) Heatset-web-offset lithographic printing—(i) Applicability. (A) The limitations of paragraph (h)(5)(ii) of this section apply to all heatset-web-offset lithographic printing lines at a subject facility. All facilities with heatset-web-offset lithographic printing lines are subject facilities unless:

(1) Total maximum theoretical emissions of VOM from all heatset-web-offset lithographic printing lines at the facility never exceed 90.7 Mg (100 tons) per calendar year in the absence of air pollution control equipment, or

(2) A federally enforceable construction permit or SIP or FIP revision for all heatset-web-offset lithographic printing line(s) at a facility requires the owner or operator to limit production or capacity of these printing line(s) to reduce total VOM emissions from all heatset-web-offset lithographic printing line(s) to 90.7 Mg (100 tons) per calendar year or less in the absence of air pollution control equipment, and

(B) Any owner or operator of any heatset-web-offset lithographic printing line that is exempt from the limitations in paragraph (h)(5)(ii) of this section because of the criteria in paragraph (h)(5)(i)(A) of this section shall be subject to the recordkeeping and reporting requirements in paragraph (h)(5)(iii)(A) of this section.

(ii) Specific provisions. No owner or operator of a subject heatset-web-offset printing line may cause or allow the operation of the subject heatset-web-offset printing line unless the owner or operator meets the requirements in paragraph (h)(5)(ii) (A) or (B) of this section and the requirements in paragraphs (h)(5)(ii) (C) and (D) of this section.

(A) An afterburner system is installed and operated that reduces 90 percent of the VOM emissions from the dryer exhaust, or

(B) The fountain solution contains no more than 8 percent, by weight, of VOM and a condensation recovery system is installed and operated that removes at least 75 percent of the non-isopropyl alcohol organic materials from the dryer exhaust, and

(C) The control device is equipped with the applicable monitoring equipment specified in paragraph (a)(4)(iv)(B) of this section and the monitoring equipment is installed, calibrated, operated and maintained according to vendor specifications at all times the control device is in use, and

(D) The control device is operated at all times when the subject printing line is in operation. The owner or operator shall demonstrate compliance with paragraph (h)(5) of this section by using the applicable test methods and procedures specified in paragraphs (a)(4) (i), (iv), and (vi) of this section and by complying with the recordkeeping and reporting requirements specified in paragraph (h)(5)(iii) of this section.

(iii) Recordkeeping and reporting. The VOM content of each fountain solution and ink and the efficiency of each control device shall be determined by the applicable test methods and procedures specified in paragraph (a)(4) of this section to establish the records required under paragraph (h)(5)(iii) of this section.

(A) Any owner or operator of a printing line which is exempted from the limitations of paragraph (h)(5)(ii) of this section because of the criteria in paragraph (h)(5)(i) of this section shall comply with the following:

(1) By July 1, 1991, the owner or operator of a facility to which paragraph (h)(5)(iii)(A) of this section is applicable shall certify to the Administrator that the facility is exempt under the provisions of paragraph (h)(5)(i) of this section. Such certification shall include:

(i) A declaration that the facility is exempt from the limitations of paragraph (h)(5)(ii) of this section because of the criteria in paragraph (h)(5)(i) of this section, and

(ii) Calculations which demonstrate that total maximum theoretical emissions of VOM from all heatset-web-offset lithographic printing lines at the facility never exceed 90.7 Mg (100 tons) per calendar year before the application of air pollution control equipment. Total maximum theoretical emissions of VOM for a heatset-web-offset lithographic printing facility is the sum of maximum theoretical emissions of VOM from each heatset-web-offset lithographic printing line at the facility. The following equation shall be used to calculate total maximum theoretical emissions of VOM per calendar year in the absence of air pollution control equipment for each heatset-web-offset lithographic printing line at the facility.

Where: Ep = Total maximum theoretical emissions of VOM from one heatset-web-offset printing line in units of kg/year (lbs/year), A = Weight of VOM per volume of solids of ink with the highest VOM content as applied each year on the printing line in units of kg VOM/l (lbs VOM/gal) of solids, and B = Total volume of solids for all inks that can potentially be applied each year on the printing line in units of l/year (gal/year). The instrument or method by which the owner or operator accurately measured or calculated the volume of each ink as applied and the amount that can potentially be applied each year on the printing line shall be described in the certification to the Administrator. C = The weight percent VOM of the fountain solution with the highest VOM content. D = The total volume of fountain solution that can potentially be used each year on the printing line in units of l/year (gal/year). The instrument and/or method by which the owner or operator accurately measured or calculated the volume of each fountain solution used and the amount that can potentially be used each year on the printing line shall be described in the certification to the Administrator.

(2) On and after July 1, 1991, the owner or operator of a facility to which paragraph (h)(5)(iii)(A) of this section is applicable shall collect and record all of the following information each year for each printing line and maintain the information at the facility for a period of three years:

(i) The name and identification of each fountain solution and ink as applied on each printing line.

(ii) The VOM content and the volume of each fountain solution and ink as applied each year on each printing line.

(3) On and after July 1, 1991, the owner or operator of a facility exempted from the limitations of paragraph (h)(5)(ii) of this section because of the criteria in paragraph (h)(5)(i) of this section shall notify the Administrator of any record showing that total maximum theoretical emissions of VOM from all printing lines exceed 90.7 Mg (100 tons) in any calendar year in the absence of air pollution control equipment shall be reported by sending a copy of such record to the Administrator within 30 days after the exceedance occurs.

(B) Any owner or operator of a printing line subject to the limitations of paragraph (h)(5)(ii) of this section and complying by means of paragraph (h)(5)(ii)(A) of this section shall comply with the following:

(1) By July 1, 1991, or upon initial start-up of a new printing line, or upon changing the method of compliance for an existing printing line from paragraph (h)(5) (ii)(B) to (ii)(A) of this section, the owner or operator of the subject printing line shall perform all tests and submit to the Administrator the results of all tests and calculations necessary to demonstrate that the subject printing line will be in compliance with paragraph (h)(5)(ii)(A) of this section on and after July 1, 1991, or on and after the initial start-up date.

(2) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a printing line subject to the limitations of paragraph (h)(5)(ii) of this section and complying by means of paragraph (h)(5)(ii)(A) of this section shall collect and record the following information each day for each printing line and maintain the information at the facility for a period of three years:

(i) Control device monitoring data.

(ii) A log of operating time for the control device, monitoring equipment and the associated printing line.

(iii) A maintenance log for the control device and monitoring equipment detailing all routine and nonroutine maintenance performed including dates and duration of any outages.

(3) On and after July 1, 1991, the owner or operator of a subject printing line shall notify the Administrator in the following instances:

(i) Any record showing violation of paragraph (h)(5)(ii)(A) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(ii) At least 30 calendar days before changing the method of compliance with paragraph (h)(5)(ii) of this section from paragraph (h)(5) (ii)(A) to (ii)(B), the owner or operator shall comply with all requirements of paragraph (h)(5)(iii)(C)(1) of this section. Upon changing the method of compliance with paragraph (h)(5)(ii) from paragraph (h)(5) (ii)(A) to (ii)(B) of this section the owner or operator shall comply with all requirements of paragraph (h)(5)(iii)(C) of this section.

(C) Any owner or operator of a printing line subject to the limitations of paragraph (h)(5)(ii) of this section and complying by means of paragraph (h)(5)(ii)(B) of this section shall comply with the following:

(1) By July 1, 1991, or upon initial start-up of a new printing line, or upon changing the method of compliance for an existing printing line from paragraph (h)(5) (ii)(A) to (ii)(B) of this section, the owner or operator of the subject printing line shall perform all tests and submit to the Administrator the results of all tests and calculations necessary to demonstrate that the subject printing line will be in compliance with paragraph (h)(5)(ii)(B) of this section on and after July 1, 1991, or on and after the initial start-up date.

(2) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a printing line subject to the limitations of paragraph (h)(5)(ii) of this section and complying by means of paragraph (h)(5)(ii)(B) of this section shall collect and record the following information each day for each printing line and maintain the information at the facility for a period of three years:

(i) The VOM content of the fountain solution used each day on each printing line.

(ii) A log of operating time for the control device and the associated printing line.

(iii) A maintenance log for the control device detailing all routine and non-routine maintenance performed including dates and duration of any outages.

(3) On and after July 1, 1991, the owner or operator of a subject printing line shall notify the Administrator in the following instances:

(i) Any record showing violation of paragraph (h)(5)(ii)(B) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(ii) At least 30 calendar days before changing the method of compliance with paragraph (h)(5)(ii) of this section from paragraph (h)(5)(ii)(B) to (h)(5)(ii)(A) of this section, the owner or operator shall comply with all requirements of paragraph (h)(5)(iii)(B)(1) of this section. Upon changing the method of compliance with paragraph (h)(5)(ii) of this section from paragraph (h)(5)(ii)(B) to (h)(5)(ii)(A) of this section, the owner or operator shall comply with all requirements of paragraph (h)(5)(iii)(B) of this section.

(iv) Compliance schedule. Every owner or operator of a heatset-web-offset lithographic printing line shall comply with the applicable requirements of paragraphs (h)(5) (ii) and (iii) of this section in accordance with the applicable compliance schedule specified in paragraph (h)(5)(iv) (A), (B) or (C) of this section.

(A) No owner or operator of a heatset-web-offset lithographic printing line which is exempt from the limitations of paragraph (h)(5)(ii) of this section because of the criteria in paragraph (h)(5)(i) of this section shall operate said printing line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraphs (h)(5)(iii)(A) and (h)(5)(ii)(A) of this section.

(B) No owner or operator of a heatset-web-offset lithographic printing line complying by means of paragraph (h)(5)(ii)(A) of this section shall operate said printing line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraphs (h)(5)(iii)(B) and (h)(5)(ii)(B) of this section.

(C) No owner or operator of a heatset-web-offset lithographic printing line complying by means of paragraph (h)(5)(ii)(B) of this section shall operate said printing line on or after July 1, 1991, unless the owner or operator has complied with, and continues to comply with, paragraph (h)(5)(iii)(C) of this section.

(6) The control and recordkeeping and reporting requirements, as well as the test methods in this paragraph, apply to the rotogravure and flexographic presses at General Packaging Products, Inc.'s (GPP) plant in Chicago, Illinois, instead of the requirements in 40 Cspan 52.741(h)(1) through 40 Cspan 52.741(h)(5).

(i) After July 1, 1992, no inks or other volatile organic material (VOM) containing materials shall at any time be applied or used which have a higher percent VOM by weight than the following:

(A) 8 percent VOM by weight for waterbased inks as applied on GPP's presses.

(B) 82 percent VOM by weight for solvent based inks as applied on GPP's presses.

(C) 100 percent VOM by weight for all other VOM containing materials (besides inks) as used on GPP's presses.

(ii) After July 1, 1992, the weight of ink and other VOM containing materials used shall not exceed the following:

(A) 200,000 pounds per year total for all waterbased inks, as applied (including dilution material). The yearly weight of waterbased inks used is to be calculated according to the procedure in paragraph (h)(6)(iii) of this section.

(B) 100,008 pounds per year total for all solvent based inks, as applied (including dilution material). The yearly weight of solvent based inks used is to be calculated according to the procedure in paragraph (h)(6)(iii) of this section.

(C) 100,000 pounds per year total (based upon the formulation of the material as it is used on the presses) for all other VOM containing materials (besides inks). The yearly weight of other VOM containing materials is to be calculated according to the procedure in paragraph (h)(6)(iii) of this section.

(iii) The yearly weight of ink/material used is to be calculated as follows:

(A) Compute the weight of ink/material used each month by the 15th of the following month.

(B) By the 15th of each month, add the monthly ink/material usage for the 12 previous months (to obtain the yearly weight of ink/material used).

(iv) Beginning on July 1, 1992, the owner and operator of GPP's plant in Chicago, Illinois, shall keep the following records for each month. All records shall be retained at GPP for 3 years and shall be made available to the Administrator on request:

(A) The name and identification number of each waterbased ink, each solvent based ink, and each other VOM containing material as applied or used on any press.

(B) The pounds of waterbased ink as applied on all presses for each month and the percent VOM by weight for each waterbased ink as applied on any press for each month.

(C) The pounds of solvent based ink as applied on all presses for each month and the percent VOM by weight for each solvent based ink as applied on any press for each month.

(D) The pounds of other (non-ink) VOM containing material used on all presses for each month and the percent VOM by weight for each (non-ink) VOM containing material as used on any press for each month.

(v) Any record showing a violation of paragraph (h)(6)(i) or (h)(6)(ii) of this section shall be reported by sending a copy of such record to the Administrator within 30 days of the violation.

(vi) To determine compliance with paragraphs (h)(6)(i) and (h)(6)(ii) of this section and to establish the records required under paragraph (h)(6)(iv) of this section the percent VOM by weight of each ink and other VOM containing material shall be determined by the applicable test methods and procedures specified in paragraph (a)(4) of this section.

(i) Leaks from synthetic organic chemical and polymer manufacturing equipment—(1) Inspection program for leaks. The owner or operator of a synthetic organic chemical or polymer manufacturing plant subject to paragraph (i) and subpart Q (sections 215.430, 215.431, 215.433, 215.434, 215.435, and 215.437) of Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) shall, for the purposes of detecting leaks, conduct a component inspection program using the test methods specified in Method 21, 40 Cspan part 60, appendix A, consistent with the following provisions:

(i) Test annually those components operated near extreme temperature or pressure such that they would be unsafe to routinely monitor and those components which would require the elevation of monitoring personnel higher than two meters above permanent worker access structures or surfaces.

(ii) Test quarterly all other pressure relief valves in gas service, pumps in light liquid service, valves in light liquid service and in gas service, and compressors.

(iii) If less than or equal to 2 percent of the valves in light liquid service and in gas service tested pursuant to paragraph (i)(1)(ii) of this section are found not to leak for five consecutive quarters, no leak tests shall be required for three consecutive quarters. Thereafter, leak tests shall resume for the next quarter. If that test shows less than or equal to 2 percent of the valves in light liquid service and in gas service are leaking, then no tests are required for the next three quarters. If more than 2 percent are leaking, then tests are required for the next five quarters.

(iv) Observe visually all pump seals weekly.

(v) Test immediately any pump seal from which liquids are observed dripping.

(vi) Test any relief valve within 24 hours after it has vented to the atmosphere.

(vii) Routine instrument monitoring of valves which are not externally regulated, flanges, and equipment in heavy liquid service, is not required. However, any valve which is not externally regulated, flange or piece of equipment in heavy liquid service that is found to be leaking on the basis of sight, smell or sound shall be repaired as soon as practicable but no later than 30 days after the leak is found.

(viii) Test immediately after repair any component that was found leaking.

(ix) Within one hour of its detection, a weatherproof, readily visible tag, in bright colors such as red or yellow, bearing an identification number and the date on which the leak was detected must be affixed on the leaking component and remain in place until the leaking component is repaired.

(x) The following components are exempt from the monitoring requirements in paragraph (i)(1) of this section:

(A) Any component that is in vacuum service, and

(B) Any pressure relief valve that is connected to an operating flare header or vapor recovery device.

(2) Alternative program for leaks. The Administrator shall approve an alternative program of monitoring, recordkeeping, or reporting to that prescribed in paragraph (i) and subpart Q (sections 215.430, 215.431, 215.433, 215.434, 215.435, and 215.437) of Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), upon a demonstration by the owner or operator of such plant that the alternative program will provide plant personnel and USEPA personnel with an equivalent ability to identify and repair leaking components. Any alternative program can only be allowed if approved by the Administrator as a SIP or FIP revision.

(j) Petroleum refining and related industries: asphalt materials—(1) Monitoring program for leaks. (i) The owner or operator of a petroleum refinery subject to subpart R (section 215.445) of Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) shall, for the purpose of detecting leaks, conduct a component monitoring program consistent with the following provisions:

(A) Test once between March 1 and June 1 of each year, by methods referenced in paragraph (a)(4)(vii) of this section, all pump seals, pipeline valves in liquid service and process drains.

(B) Test once each quarter of each calendar year, by methods referenced in paragraph (a)(4)(vii) of this section, all pressure relief valves in gaseous service, pipeline valves in gaseous service and compressor seals.

(C) Inaccessible valves may be tested once each calendar year instead of once each quarter of each calendar year.

(D) Observe visually all pump seals weekly.

(E) Test immediately any pump seal from which liquids are observed dripping,

(F) Test any relief valve within 24 hours after it has vented to the atmosphere, and

(G) Test immediately after repair any component that was found leaking.

(ii) Storage tank valves and pressure relief devices connected to an operating flare header or vapor recovery device are exempt from the monitoring requirements in paragraph (j)(1)(i) of this section.

(iii) The Administrator may require more frequent monitoring than would otherwise be required by paragraph (j)(1)(i) of this section for components which are demonstrated to have a history of leaking.

(2) Alternative program for leaks. The Administrator may approve an alternative program of monitoring, recordkeeping or reporting to that prescribed in paragraph (j)(1) of this section and subpart R (sections 215.446, 215.448, and 215.449) of Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), upon a demonstration by the owner or operator of a petroleum refinery that the alternative program will provide refinery and USEPA personnel with an equivalent ability to identify and repair leaking components. Any alternative program can only be allowed if approved by the Administrator as a SIP or FIP revision.

(3) Compliance schedule for leaks. The owner or operator of a petroleum refinery shall adhere to the increments of progress contained in the following schedule:

(i) Submit to the Administrator a monitoring program consistent with subpart R (section 215.446) of Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) prior to September 1, 1990.

(ii) Submit to the Administrator the first monitoring report pursuant to subpart R (section 215.449) of Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) prior to October 1, 1990.

(k)-(l) [Reserved]

(m) Pharmaceutical manufacturing—(1) Applicability. (i) The rules of paragraph (m) of this section, except for paragraphs (m)(4) through (m)(6) of this section, apply to all emission sources of VOM, including but not limited to reactors, distillation units, dryers, storage tanks for VOL, equipment for the transfer of VOL, filters, crystallizers, washers, laboratory hoods, pharmaceutical coating operations, mixing operations and centrifuges used in manufacturing, including packaging, of pharmaceuticals, and emitting more than 6.8 kg/day (15 lbs/day) and more than 2,268 kg/year (2.5 tons/year) of VOM. If an emission source emits less than 2,268 kg/year (2.5 tons/year) of VOM, the requirements of this paragraph still apply to the emission source if VOM emissions from the emission source exceed 45.4 kg/day (100 lbs/day).

(ii) Notwithstanding paragraph (m)(1)(i) of this section, the air suspension coater/dryer, fluid bed dryers, tunnel dryers, and Accelacotas located in Libertyville Township, Lake County, Illinois shall be exempt from the rules of paragraph (m) of this section, except for paragraphs (m)(4) through (m)(6) of this section, if emissions of VOM not vented to air pollution control equipment do not exceed the following levels:

(A) For the air suspension coater/dryer: 2,268 kg/year (2.5 tons/year);

(B) For each fluid bed dryer: 4,535 kg/year (5.0 tons/year);

(C) For each tunnel dryer: 6,803 kg/year (7.5 tons/year); and

(D) For each Accelacota: 6,803 kg/year (7.5 tons/year).

(iii) Paragraphs (m)(4) through (m)(6) of this section apply to a plant having one or more emission sources that:

(A) Are used to manufacture pharmaceuticals, and

(B) Emit more than 6.8 kg/day (15 lbs/day) of VOM and more than 2,268 kg/year (2.5 tons/year) of VOM, or, if less than 2,268 kg/year (2.5 tons/year), these paragraphs still apply if emissions from one or more sources exceed 45.4 kg/day (100 lbs/day).

(iv) No owner or operator shall violate any condition in a permit when the condition results in exclusion of an emission source from paragraph (m) of this section.

(v) Any pharmaceutical manufacturing source that becomes subject to the provisions of paragraph (m) of this section at any time shall remain subject to the provisions of paragraph (m) of this section at all times.

(vi) Emissions subject to paragraph (m) of this section shall be controlled at all times consistent with the requirements set forth in paragraph (m) of this section.

(vii) Control devices required pursuant to paragraph (m) of this section shall be operated at all times when the source it is controlling is operated.

(viii) Determinations of daily and annual emissions for purposes of paragraph (m)(1) of this section shall be made using both data on the hourly emission rate (or the emissions per unit of throughput) and appropriate daily and annual data from records of emission source operation (or material throughput or material consumption data). In the absence of representative test data pursuant to paragraph (m)(8) of this section for the hourly emission rate (or the emissions per unit of throughput), such items shall be calculated using engineering calculations, including the methods described in appendix B of “Control of Volatile Organic Emissions from Manufacturing of Synthesized Pharmaceutical Products” (EPA-450/2-78-029). (This subparagraph shall not affect the Administrator's authority to require emission tests to be performed pursuant to paragraph (m)(8) of this section.)

(2) Control of reactors, distillation units, crystallizers, centrifuges and vacuum dryers. (i) The owner or operator shall equip all reactors, distillation units, crystallizers, centrifuges and vacuum dryers that are used to manufacture pharmaceuticals with surface condensers or other air pollution control equipment listed in paragraph (m)(2)(i)(B) of this section.

(A) If a surface condenser is used, it shall be operated such that the condenser outlet gas temperature does not exceed:

(1) 248.2 K (−13 °F) when condensing VOM of vapor pressure greater than 40.0kPa (5.8 psi) at 294.3K (70 °F), or

(2) 258.2 K (5 °F) when condensing VOM of vapor pressure greater than 20.0 kPa (2.9 psi) at 294.3 K (70 °F), or

(3) 273.2 K (32 °F) when condensing VOM of vapor pressure greater than 10.0 kPa (1.5 psi) at 294.3 K (70 °F), or

(4) 283.2 K (50 °F) when condensing VOM of vapor pressure greater than 7.0 kPa (1.0 psi) at 294.3 K (70 °F), or

(5) 298.2 K (77 °F) when condensing VOM of vapor pressure greater than 3.45 kPa (0.5 psi) at 294.3 K (70 °F).

(B) If a scrubber, carbon adsorption, thermal afterburner, catalytic afterburner, or other air pollution control equipment other than a surface condenser is used, such equipment shall provide a reduction in the emissions of VOM of 90 percent or more.

(ii) The owner or operator shall enclose all centrifuges used to manufacture pharmaceuticals and that have an exposed VOL surface, where the VOM in the VOL has a vapor pressure of 3.45 kPa (0.5 psi) or more at 294.3 K (70 °F), except as production, sampling, maintenance, or inspection procedures require operator access.

(3) Control of air dryers, production equipment exhaust systems and filters. (i) The owner or operator of an air dryer or production equipment exhaust system used to manufacture pharmaceuticals shall control the emissions of VOM from such emission sources by air pollution control equipment which reduces by 90 percent or more the VOM that would otherwise be emitted into the atmosphere.

(ii) The owner or operator shall enclose all rotary vacuum filters and other filters used to manufacture pharmaceuticals and that have an exposed VOL surface, where the VOM in the VOL has a vapor pressure of 3.45 kPa (0.5 psi) or more at 294 K (70 °F), except as production, sampling, maintenance, or inspection procedures require operator access.

(4) Material storage and transfer. The owner or operator of a pharmaceutical manufacturing plant shall:

(i) Provide a vapor balance system that is at least 90 percent effective in reducing VOM emissions from truck or railcar deliveries to storage tanks with capacities equal to or greater than 7.57 m 3 (2,000 gal) that store VOL with vapor pressures greater than 28.0 kPa (4.1 psi) at 294.3 K (70 °F), and

(ii) Install, operate, and maintain pressure/vacuum conservation vents set at 0.2 kPa (0.03 psi) or greater on all storage tanks that store VOL with vapor pressures greater than 10 kPa (1.5 psi) at 294.3 K (70 °F).

(5) In-process tanks. The owner or operator shall install covers on all in-process tanks used to manufacture pharmaceuticals and containing a VOL at any time. These covers must remain closed, except as production, sampling, maintenance or inspection procedures require operator access.

(6) Leaks. The owner or operator of a pharmaceutical manufacturing plant shall repair any component from which a leak of VOL can be observed. The repair shall be completed as soon as practicable but no later than 15 days after the leak is found. If the leaking component cannot be repaired until the process unit is shut down, the leaking component must then be repaired before the unit is restarted.

(7) Other emission sources. The owner or operator of a washer, laboratory hood, tablet coating operation, mixing operation or any other process emission source not subject to paragraphs (m)(2) through (m)(6) of this section, and used to manufacture pharmaceuticals shall control the emissions of VOM from such emission sources by:

(i) Air pollution control equipment which reduces by 81 percent or more the VOM that would otherwise be emitted to the atmosphere, or

(ii) A surface condenser which captures all the VOM which would otherwise be emitted to the atmosphere and which meets the requirements of paragraph (m)(2)(i) of this section.

(8) Testing. (i) Upon request by the Administrator, the owner or operator of any VOM emission source subject to paragraph (m) or exempt from paragraph (m) of this section by virtue of the provisions of paragraph (m)(1) of this section shall, at his own expense, demonstrate compliance to the Administrator by the methods or procedures listed in paragraph (a)(vi)(A) of this section.

(ii) A person planning to conduct a VOM emissions test to demonstrate compliance with paragraph (m) of this section shall notify the Administrator of that intent not less than 30 calendar days before the planned initiation of the test.

(9) Monitoring and recordkeeping for air pollution control equipment—(i) Monitoring. (A) At a minimum, continuous monitors for the following parameters shall be installed on air pollution control equipment used to control sources subject to paragraph (m) of this section:

(1) Destruction device combustion temperature.

(2) Temperature rise across a catalytic afterburner bed.

(3) VOM concentration on a carbon absorption unit to determine breakthrough.

(4) Outlet gas temperature of a refrigerated condenser.

(5) Temperature of a non-refrigerated condenser coolant supply system.

(B) Each monitor shall be equipped with a recording device.

(C) Each monitor shall be calibrated quarterly.

(D) Each monitor shall operate at all times while the associated control equipment is operating.

(ii) Recordkeeping. (A) The owner or operator of a pharmaceutical manufacturing facility shall maintain the following records:

(1) Parameters listed in paragraph (m)(9)(i)(A) of this section shall be recorded.

(2) For sources subject to paragraph (m)(2) of this section, the vapor pressure of VOM being controlled shall be recorded for every process.

(B) For any leak subject to paragraph (m)(6) of this section which cannot be readily repaired within one hour after detection, the following records shall be kept:

(1) The name of the leaking equipment,

(2) The date and time the leak is detected,

(3) The action taken to repair the leak, and

(4) The data and time the leak is repaired.

(C) The following records shall be kept for emission sources subject to paragraph (m)(5) of this section which contain VOL:

(1) For maintenance and inspection:

(i) The date and time each cover is opened,

(ii) The length of time the cover remains open, and

(iii) The reason why the cover is opened.

(2) For production and sampling, detailed written procedures or manufacturing directions specifying the circumstances under which covers may be opened and the procedures for opening covers.

(D) For each emission source used in the manufacture of pharmaceuticals for which the owner or operator of a pharmaceutical manufacturing plant claims emission standards are not applicable, because the emissions are below the applicability cutoffs in paragraph (m)(1)(i) of this section or paragraph (m)(1)(ii) of this section the owner or operator shall:

(1) Maintain a demonstration including detailed engineering calculations of the maximum daily and annual emissions for each such emission source showing that the emissions are below the applicability cutoffs in paragraph (m)(1)(i) or paragraph (m)(1)(ii) of this section, as appropriate, for the current and prior calendar years;

(2) Maintain appropriate operating records for each such emission source to identify whether the applicability cutoffs in paragraph (m)(1)(i) or paragraph (m)(1)(ii) of this section, as appropriate, are ever exceeded; and

(3) Provide written notification to the Administrator within 30 days of a determination that such an emission source has exceeded the applicability cutoffs in paragraph (m)(1)(i) or paragraph (m)(1)(ii) of this section, as appropriate.

(E) Records required under paragraph (m)(9)(ii)(A) of this section shall be maintained by the owner or operator for a minimum of two years after the date on which they are made.

(F) Copies of the records shall be made available to the Administrator upon verbal or written request.

(n)-(p) [Reserved]

(q) Gasoline distribution—(1) Bulk gasoline plants. (i) Subject to paragraph (q)(1)(v) of this section, no person may cause or allow the transfer of gasoline from a delivery vessel into a stationary storage tank located at a bulk gasoline unless:

(A) The delivery vessel and the stationary storage tank are each equipped with a vapor collection system that meets the requirements of paragraph (q)(1)(iv)(D) of this section,

(B) Each vapor collection system is operating,

(C) The delivery vessel displays the appropriate sticker pursuant to the requirements of sections 215.584 (b) or (d) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742),

(D) The pressure relief valve(s) on the stationary storage tank and the delivery vessel are set to release at no less than 0.7 psi or the highest pressure allowed by state or local fire codes or the guidelines of the National Fire Prevention Association, and

(E) The stationary storage tank is equipped with a submerged loading pipe.

(ii) Subject to paragraph (q)(1)(vi) of this section, no person may cause or allow the transfer of gasoline from a stationary storage tank located at a bulk gasoline plant into a delivery vessel unless:

(A) The requirements set forth in paragraphs (q) (1)(i)(A) through (1)(i)(D) of this section are met, and

(B) Equipment is available at the bulk gasoline plant to provide for the submerged filling of the delivery vessel or the delivery vessel is equipped for bottom loading.

(iii) Subject to paragraph (q)(1)(v) of this section, each owner of a stationary storage tank located at a bulk gasoline plant shall:

(A) Equip each stationary storage tank with a vapor control system that meets the requirements of paragraph (q) (1)(i) or (1)(ii) of this section, whichever is applicable,

(B) Provide instructions to the operator of the bulk gasoline plant describing necessary maintenance operations and procedures for prompt notification of the owner in case of any malfunction of a vapor control system, or

(C) Repair, replace or modify any worn out or malfunctioning component or element of design.

(iv) Subject to paragraph (q)(1)(v) of this section, each operator of a bulk gasoline plant shall:

(A) Maintain and operate each vapor control system in accordance with the owner's instructions,

(B) Promptly notify the owner of any scheduled maintenance or malfunction requiring replacement or repair of a major component of a vapor control system,

(C) Maintain gauges, meters or other specified testing devices in proper working order, and

(D) Operate the bulk plant vapor collection system and gasoline loading equipment in a manner that prevents:

(1) Gauge pressure from exceeding 45.7 cm (18 in.) of water and vacuum from exceeding 15.2 cm (6 in.) of water, as measured as close as possible to the vapor hose connection,

(2) A reading equal to or greater than 100 percent of the lower explosive limit (LEL measured as propane) when tested in accordance with the procedure described in “Control of Volatile Organic Compound Leaks from Gasoline Tank Trucks and Vapor Collection Systems”, Appendix B, EPA 450/2-78-051 (which is available for purchase from the National Technical Information Services, 5285 Port Royal Road, Springfield, VA 22161), and

(3) Avoidable leaks of liquid during loading or unloading operations.

(E) Provide a pressure tap or equivalent on the bulk plant vapor collection system in order to allow the determination of compliance with paragraph (q)(1)(iv)(D)(1) of this section, and

(F) Within 15 business days after discovery of any leak by the owner, operator, or the Administrator, repair and retest a vapor collection system which exceeds the limits of paragraph (q)(1)(iv)(D) (1) or (2) of this section.

(v) The requirements of paragraphs (q) (1)(i), (1)(iii) and (1)(iv) of this section, shall not apply to:

(A) Any stationary storage tank with a capacity of less than 2,177 l (575 gal), or

(B) Any bulk gasoline plant whose daily gasoline throughtput is less than 15,140 l (4,000 gal/day) on a thirty-day rolling average.

(vi) The requirements of paragraph (q)(1)(ii) of this section shall only apply to bulk gasoline plants:

(A) Whose daily gasoline throughput is greater than or equal to 15,140 l (4,000 gal/day) on a thirty-day rolling average, and

(B) That either distribute gasoline to gasoline dispensing facilities subject to the requirements of section 215.583(a)(2) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742) or that are in Cook, DuPage, Kane, Lake, McHenry or Will County.

(vii) Any bulk gasoline plant which is ever subject to paragraph (q)(1) (i), (ii), (iii) or (iv) of this section shall always be subject to these paragraphs.

(2) [Reserved]

(r) [Reserved]

(s) Paint and ink manufacturing—(1) Applicability. (i) Paragraph (s) shall apply to all paint and ink manufacturing plants which:

(A) Include process emission sources not subject to subparts (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or to paragraphs (d), (e) (excluding paragraph (e)(1)(i)(L)), (h) (excluding paragraph (h)(5)), (i), (j), or (q)(1) of this section; and which as a group both:

(1) Have maximum theoretical emissions of 91 Mg (100 tons) or more per calendar year of VOM if no air pollution control equipment were used, and

(2) Are not limited to less than 91 Mg (100 tons) of VOM emissions per calendar year in the absence of air pollution control equipment, through production or capacity limitations contained in a federally enforceable construction permit or a SIP or FIP revision, or

(B) Produce more than 7,570,820 l (2,000,000 gal) per calendar year of paint or ink formulations, which contain less than 10 percent (by weight) water, and ink formulations not containing as the primary solvents water, Magie oil or glycol.

(ii) For the purposes of paragraph (s) of this section, uncontrolled VOM emissions are the emissions of VOM which would result if no air pollution control equipment were used.

(2) Exemption for waterbase material and heatset-offset ink. The requirements of paragraphs (s)(4) and (s)(5) of this section and paragraph (s)(7)(i) of this section shall not apply to equipment while it is being used to produce either:

(i) Paint or ink formulations which contain 10 percent or more (by weight) water, or

(ii) Inks containing Magie oil and glycol as the primary solvent.

(3) Permit conditions. No person shall violate any condition in a federally enforceable permit when the condition results in exclusion of the plant or an emission source from paragraph (s).

(4) Open-top mills, tanks, vats or vessels. No person shall operate an open-top mill, tank, vat or vessel with a volume of more than 45 l (12 gal) for the production of paint or ink unless:

(i) The mill, tank, vat or vessel is equipped with a cover which completely covers the mill, tank, vat or vessel opening except for an opening no larger than necessary to allow for safe clearance for a mixer shaft. Such cover shall extend at least 1.27 cm (0.5 in.) beyond the outer rim of the opening or be attached to the rim.

(ii) The cover remains closed except when production, sampling, maintenance or inspection procedures require access.

(iii) The cover is maintained in good condition such that, when in place, it maintains contact with the rim of the opening for at least 90 percent of the circumference of the rim.

(5) Grinding mills. (i) No person shall operate a grinding mill for the production of paint or ink which is not maintained in accordance with the manufacturer's specifications.

(ii) No person shall operate a grinding mill fabricated or modified after the effective date of paragraph (s) which is not equipped with fully enclosed screens.

(iii) The manufacturer's specifications shall be kept on file at the plant by the owner or operator of the grinding mill and be made available to any person upon verbal or written request during business hours.

(6) Storage tanks. (i) The owner or operator shall equip tanks storing VOL with a vapor pressure greater than 10 kPa (1.5 psi) at 20 °C (68 °F) with pressure/vacuum conservation vents set as a minimum at + /-0.2 kPa (0.029 psi). These controls shall be operated at all times. An alternative air pollution control system may be used if it results in a greater emission reduction than these controls. Any alternative control system can only be allowed if approved by the Administrator as a SIP or FIP revision.

(ii) Stationary VOL storage containers with a capacity greater than 946 l (250 gal) shall be equipped with a submerged-fill pipe or bottom fill. These controls shall be operated at all times. An alternative control system can only be allowed if approved by the Administrator as a SIP or FIP revision.

(7) Leaks. The owner or operator of a paint or ink manufacturing plant shall, for the purpose of detecting leaks, conduct an equipment monitoring program as set forth below:

(i) Each pump shall be checked by visual inspection each calendar week for indications of leaks, that is, liquids dripping from the pump seal. If there are indications of liquids dripping from the pump seal, the pump shall be repaired as soon as practicable, but no later than 15 calendar days after the leak is detected.

(ii) Any pump, valve, pressure relief valve, sampling connection, open-ended valve and flange or connector containing a fluid which is at least 10 percent VOM by weight which appears to be leaking on the basis of sight, smell or sound shall be repaired as soon as practicable, but no later than 15 calendar days after the leak is detected.

(iii) A weather proof, readily visible tag, in bright colors such as red or yellow, bearing an identification number and the date on which the leak was detected shall be attached to leaking equipment. The tag may be removed upon repair, that is, when the equipment is adjusted or otherwise altered to allow operation without leaking.

(iv) When a leak is detected, the owner or operator shall record the date of detection and repair and the record shall be retained at the plant for at least two years from the date of each detection or each repair attempt. The record shall be made available to any person upon verbal or written request during business hours.

(8) Clean up. (i) No person shall clean paint or ink manufacturing equipment with organic solvent unless the equipment being cleaned is completely covered or enclosed except for an opening no larger than necessary to allow safe clearance for proper operation of the cleaning equipment, considering the method and materials being used.

(ii) No person shall store organic wash solvent in other than closed containers, unless closed containers are demonstrated to be a safety hazard, or dispose of organic wash solvent in a manner such that more than 20 percent by weight is allowed to evaporate into the atmosphere.

(9) Compliance schedule. Every owner or operator of an emission source subject to the control requirements of paragraph (s) of this section shall comply with the requirements of paragraph (s) of this section on and after July 1, 1991.

(10) Recordkeeping and reporting. (i) Upon request by the Administrator, the owner or operator of an emission source which claims to be exempt from the requirements of paragraph (s) of this section shall submit records to the Administrator within 30 calendar days from the date of the request which document that the emission source is in fact exempt from paragraph (s) of this section. These records shall include (but are not limited to) the percent water (by weight) in the paint or ink being produced and the quantity of Magie oil, glycol and other solvents in the ink being produced.

(ii) Every owner or operator of an emission source which is subject to the requirements of paragraph (s) of this section shall maintain all records necessary to demonstrate compliance with those requirements at the facility for three years.

(t) [Reserved]

(u) Miscellaneous fabricated product manufacturing processes—(1) Applicability. (i) The requirements of paragraph (u) of this section shall apply to a plant's miscellaneous fabricated product manufacturing process emission sources which are not included within any of the source categories specified in subparts (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or specified in paragraph (d), (e), (h), (i), (j), or (q)(1) of this section; if the plant is subject to paragraph (u) of this section. A plant is subject to paragraph (u) of this section if it contains process emission sources, not regulated by subparts (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or by paragraph (d), (e) (excluding paragraph (e)(1)(i)(L)), (h) (excluding paragraph (h)(5)), (i), (j), or (q)(1) of this section; which as a group both:

(A) Have maximum theoretical emissions of 91 Mg (100 tons) or more per calendar year of VOM if no air pollution control equipment were used, and

(B) Are not limited to less than 91 Mg (100 tons) of VOM emissions per calendar year in the absence of air pollution control equipment, through production or capacity limitations contained in a federally enforceable construction permit or a SIP or FIP revision.

(ii) If a plant ceases to fulfill the criteria of paragraph (u)(1)(i) of this section, the requirements of paragraph (u) of this section shall continue to apply to a miscellaneous fabricated products manufacturing process emission source which was ever subject to the control requirements of paragraph (u)(3) of this section.

(iii) No limits under paragraph (u) of this section shall apply to emission sources with emissions of VOM to the atmosphere less than or equal to 0.91 Mg (1.0 ton) per calendar year if the total emissions from such sources not complying with paragraph (u)(3) of this section does not exceed 4.5 Mg (5.0 tons) per calendar year.

(iv) For the purposes of paragraph (u) of this section, an emission source shall be considered regulated by a subpart (of the Illinois rules) or paragraph if it is subject to the limits of that subpart (of the Illinois rules) or paragraph. An emission source is not considered regulated by a subpart (of the Illinois rules) or paragraph if its emissions are below the applicability cutoff level or if the source is covered by an exemption.

(v) For the purposes of paragraph (u) of this section, uncontrolled VOM emissions are the emissions of VOM which would result if no air pollution control equipment were used.

(2) Permit conditions. No person shall violate any condition in a permit when the condition results in exclusion of the plant or an emission source from paragraph (u) of this section.

(3) Control requirements. Every owner or operator of an emission source subject to paragraph (u) of this section shall comply with the requirements of paragraph (u)(3) (i), (ii) or (iii) of this section:

(i) Emission capture and control techniques which achieve an overall reduction in uncontrolled VOM emissions of at least 81 percent, or

(ii) For coating lines, the daily-weighted average VOM content shall not exceed 0.42 kg VOM/l (3.5 lbs VOM/gal) of coating as applied (minus water and any compounds which are specifically exempted from the definition of VOM) during any day. Owners and Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or

(iii) An alternative control plan which has been approved by the Administrator as a SIP or FIP revision.

(4) Compliance schedule. Every owner or operator of an emission source subject to the control requirements of paragraph (u) of this section shall comply with the requirements of paragraph (u) of this section on and after July 1, 1991.

(5) Testing. Any owner or operator of a VOM emission source which is subject to paragraph (u) of this section shall demonstrate compliance with paragraph (u)(3) of this section by using the applicable test methods and procedures specified in paragraph (a)(4) of this section.

(6) The control requirements in this paragraph apply to the adhesive globe coating operations at Replogle's Broadview facility in Cook County, Illinois, instead of the control requirements in paragraph (u)(3) of this section.

(i) After October 6, 1991, no coatings shall at any time be applied which exceed the following emission limitations for the specified coating.

(A) 7.0 lbs VOM per gallon of adhesive coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied to coat globes. Such coating consists of #7879446 Methylene Chloride (RGI #01004100). The Administrator shall be notified at least ten (10) days prior to the use of any replacement adhesive for coating globes.

(B) [Reserved]

(ii) After October 6, 1991, the volume of coatings used shall not exceed the following:

(A) 572 gallons per year total for all coatings specified in paragraph (u)(6)(i)(A) of this section. The yearly volume of coatings used are to be calculated as follows:

(1) Compute the volume of specified coating used each month by the 15th of the following month.

(2) By the 15th of each month, add the monthly coating use for the 12 previous months (to obtain the yearly volume of coatings used).

(B) [Reserved]

(iii) Beginning on October 6, 1991, the owner and operator of the Replogle Globes, Inc. plant in Broadview, Illinois shall keep the following records for each month. All records shall be retained at Replogle Globes, Inc. for three (3) years and shall be made available to the Administrator on request:

(A) The name and identification number of each coating as applied on any adhesive globe coating line.

(B) The weight of VOM per volume and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each month on any adhesive globe coating line.

(7) The control requirements in this paragraph apply to the glass candle container coating line(s) and silk screening machines at the Candle Corporation of America (CCA), Chicago, Illinois facility, instead of the control requirements in paragraph (u)(3) of this section.

(i) After June 1, 1992, no coatings or inks shall at any time be applied, at any coating or ink applicator, which exceed the following emission limitations for the specified coating or ink.

(A) 6.04 pounds (lbs) volatile organic material (VOM) per gallon of clear lacquer/varnish (minus water and any compounds which are specifically exempted from the definition of VOM) as applied to coat glass candle containers. Such clear lacquer/varnish (multi-color) is identified as LP3500. The Administrator must be notified at least 10 days prior to the use of any replacement clear lacquers/varnishes.

(B) 5.23 lbs VOM per gallon of translucent coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied to coat glass candle containers. Such translucent coating (multi-color) is identified as LP3603. The Administrator must be notified at least 10 days prior to the use of any replacement translucent coatings.

(C) 5.84 lbs VOM per gallon of white lacquer (minus water and any compounds which are specifically exempted from the definition of VOM) as applied to coat glass candle containers. Such white lacquer is identified as LP3507. The Administrator must be notified at least 10 days prior to the use of any replacement white lacquers.

(D) 3.40 lbs VOM per gallon of fast dry enamel silk screen printing ink (minus water and any compounds which are specifically exempted from the definition of VOM) as applied to print onto glass candle containers.

(ii) After June 1, 1992, the volume of coating and ink used shall not exceed the following:

(A) 2,164 gallons per month total for all coatings specified in paragraph (u)(7)(i)(A) of this section.

(B) 369 gallons per month total for all coatings specified in paragraph (u)(7)(i)(B) of this section.

(C) 49 gallons per month total for all coatings specified in paragraph (u)(7)(i)(C) of this section.

(D) 50 gallons per month total for all inks specified in paragraph (u)(7)(i)(D) of this Section.

(iii) Beginning on June 1, 1992, the owner and operator of CCA's plant in Chicago, Illinois, shall keep the following records for each month. All records shall be retained at CCA for 3 years and shall be made available to the Administrator on request.

(A) The name and identification number of each coating and ink as applied on any glass candle container coating line or silk screening machine.

(B) The weight of VOM per volume and the volume of each coating and ink (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each month on any glass candle container coating line or silk screening machine.

(iv) After June 1, 1992, no more than 100 gallons per month of cleaning solvent is allowed to be used on the glass candle container coating line(s) at CCA. The only cleaning solvents allowed for use are acetone (identified as LP3525) and methyl ethyl ketone (identified as LP3520). Beginning on June 1, 1992, CCA shall keep monthly records of the type and volume of all cleaning solvents used. All such records shall be retained at CCA for 3 years and shall be made available to the Administrator on request.

(v) After June 1, 1992, no more than 50 gallons per month of cleaning solvent is allowed to be used on the glass candle container silk screening machines at CCA. The only cleaning solvent allowed for use is petroleum naphtha (identified as light aromatic naphtha with 7.28 lbs VOM per gallon, minus water and any compounds which are specifically exempted from the definition of VOM). Beginning on June 1, 1992, CCA shall keep monthly records of the type and volume and the weight of VOM per volume (minus water and any compounds which are specifically exempted from the definition of VOM) of all cleaning solvents used on the glass candle container silk screening machines. All such records shall be retained at CCA for 3 years and shall be made available to the Administrator on request.

(8) The control, recordkeeping and reporting requirements in this paragraph apply to the cellulose food casing manufacturing operations at the Viskase Corporation plant in Bedford Park, Illinois (Cook County) instead of the requirements in paragraph (v) of this section, the other parts of paragraph (u) of this section, and the recordkeeping requirements in paragraph (y) of this section. Unless otherwise stated, the following requirements must be met by Viskase on and after November 21, 1995.

(i) VOM emissions shall never exceed 3.30 tons per day.

(ii) VOM emissions shall not exceed 2.22 tons per day, on a monthly average, during June, July, and August.

(iii) VOM emissions shall not exceed 2.44 tons per day during June, July, and August.

(iv) Compliance with the emission limits in paragraphs (u)(8) (i) through (iii) of this section, and the records in paragraph (u)(8)(v) of this section, shall be determined using an emission factor of “0.72 pounds of VOM emissions per pound of carbon disulfide consumed.”

(v) Viskase must keep the following daily records:

(A) The pounds of carbon disulfide per charge for its Fibrous process. If charges with different levels of carbon disulfide per charge are used the same day, a separate record must be kept for each level of carbon disulfide per charge.

(B) The pounds of carbon disulfide per charge for its NOJAX process. If charges with different levels of carbon disulfide per charge are used the same day, a separate record must be kept for each level of carbon disulfide per charge.

(C) The number of charges per day, for each level of carbon disulfide per charge, used in Viskase's Fibrous process.

(D) The number of charges per day, for each level of carbon disulfide per charge, used in Viskase's NOJAX process.

(E) The total quantity of carbon disulfide used per day in Viskase's Fibrous process, the total quantity of carbon disulfide used per day in Viskase's NOJAX process, and the daily VOM emissions resulting from use of the carbon disulfide.

(F) The monthly use of carbon disulfide, and the monthly VOM emissions resulting from use of the carbon disulfide, during June, July, and August.

(vi) Any violation of the emission limits in paragraphs (u)(8) (i) through (iii) of this section must be reported to USEPA within 30 days of its occurrence.

(vii) In order to determine daily and monthly VOM emissions, the test methods in paragraph (a)(4) of this section may be used in addition to, and take precedence over, the emission factor cited in paragraph (u)(8)(iv) of this section. Method 15 is to be used instead of Methods 18, 25, and 25A when the test methods in paragraph (a)(4) of this section are used to determine VOM emissions from Viskase's cellulose food casing facility.

(v) Miscellaneous formulation manufacturing processes—(1) Applicability. (i) The requirements of paragraph (v) of this section shall apply to a plant's miscellaneous formulation manufacturing process emission sources, which are not included within any of the source categories specified in subpart (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452),(S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or specified in paragraph (d), (e), (h), (i), (j), or (q)(1) of this section; if the plant is subject to paragraph (v) of this section. A plant is subject to paragraph (v) of this section if it contains process emission sources, not regulated by subpart (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or by paragraph (d), (e) (excluding paragraph (e)(1)(i)(L)), (h) (excluding paragraph (h)(5)), (i), (j), or (q)(1) of this section; which as a group both:

(A) Have maximum theoretical emissions of 91 Mg (100 tons) or more per calendar year of VOM if no air pollution control equipment were used, and

(B) Are not limited to less than 91 Mg (100 tons) of VOM emissions per calendar year in the absence of air pollution control equipment, through production or capacity limitations contained in a federally enforceable construction permit or a SIP or FIP revision.

(ii) If a plant ceases to fulfill the criteria of paragraph (v)(1)(i) of this section, the requirements of paragraph (v) of this section shall continue to apply to a miscellaneous formulation manufacturing process emission source which was ever subject to the control requirements of paragraph (v)(3) of this section.

(iii) No limits under paragraph (v) of this section shall apply to emission sources with emissions of VOM to the atmosphere less than or equal to 2.3 Mg (2.5 tons) per calendar year if the total emissions from such sources not complying with paragraph (v)(3) of this section does not exceed 4.5 Mg (5.0 tons) per calendar year.

(iv) For the purposes of paragraph (v) of this section, an emission source shall be considered regulated by a subpart (of the Illinois rules) or paragraph if it is subject to the limits of that subpart (of the Illinois rules) or paragraph. An emission source is not considered regulated by a subpart (of the Illinois rules) or paragraph if its emissions are below the applicability cutoff level or if the source is covered by an exemption.

(v) For the purposes of paragraph (v) of this section uncontrolled VOM emissions are the emissions of VOM which would result if no air pollution control equipment were used.

(2) Permit conditions. No person shall violate any condition in a permit when the condition results in exclusion of the plant or an emission source from paragraph (v) of this section.

(3) Control requirements. Every owner or operator of an emission source subject to paragraph (v) of this section shall comply with the requirements of paragraph (v)(3) (i) or (ii) of this section.

(i) Emission capture and control techniques which achieve an overall reduction in uncontrolled VOM emissions of at least 81 percent, or

(ii) An alternative control plan which has been approved by the Administrator as a SIP or FIP revision.

(4) Compliance schedule. Every owner or operator of an emission source subject to the control requirements of paragraph (v) of this section shall comply with the requirements of paragraph (v) of this section on and after July 1, 1991.

(5) Testing. Any owner or operator of a VOM emission source which is subject to paragraph (v) of this section shall demonstrate compliance with paragraph (v)(3) of this section by using the applicable test methods and procedures specified in paragraph (a)(4) of this section.

(6) The control requirements in this paragraph apply to the 7 blenders and 3 moguls of the adhesive coating solution formulation (compounding) operations at the Minnesota Mining and Manufacturing Corporation's (3M) Bedford Park facility in Cook County, Illinois, instead of the control requirements in paragraph (v)(3) of this section.

(i) After September 1, 1991, the following operating restrictions shall apply to 3M's Bedford Park, Illinois, compounding operations.

(A) The combined operating hours for all blenders shall not exceed 8,400 hours per quarter (rolled on a monthly basis). The combined quarterly operating hours of all blenders are to be calculated as follows:

(1) By the 15th of each month, compute the combined monthly operating hours of all blenders during the previous month.

(2) By the 15th of each month, add the monthly operating hours of all blenders for the 3 previous months (to obtain the combined quarterly operating hours of all blenders).

(B) The combined operating hours for all moguls shall not exceed 4,200 hours per quarter (rolled on a monthly basis). The quarterly operating hours of all moguls are to be calculated as follows:

(1) By the 15th of each month, compute the combined monthly operating hours of all moguls during the previous month.

(2) By the 15th of each month, add the monthly operating hours of all moguls for the 3 previous months (to obtain the combined quarterly operating hours of all moguls).

(ii) Beginning on September 1, 1991, the owner and operator of the 3M Bedford Park Plant in Bedford Park, Illinois, shall keep the following records. These records shall be compiled on a monthly basis, be retained at the 3M facility for a period of 3 years, and be made available to the Administrator upon request.

(A) Separate monthly records for each of the 7 blenders identifying each batch and the length of each batch as well as the total monthly hours of operation for all blenders.

(B) Separate monthly records for each of the 3 moguls identifying each batch and the length of each batch as well as the total monthly hours of operation for all moguls.

(w) Miscellaneous organic chemical manufacturing processes—(1) Applicability. (i) The requirements of paragraph (w) of this section shall apply to a plant's miscellaneous organic chemical manufacturing process emission sources which are not included within any of the source categories specified in subparts (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or specified in paragraph (d), (e), (h), (i), (j), or (q)(1) of this section; if the plant is subject to paragraph (w) of this section. A plant is subject to paragraph (w) of this section if it contains process emission sources, not regulated by subparts (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or by paragraph (d), (e) (excluding paragraph (e)(1)(i)(L)), (h) (excluding paragraph (h)(5)), (i), (j), or (q)(1) of this section; which as a group both:

(A) Have maximum theoretical emissions of 91 Mg (100 tons) or more per calendar year of VOM if no air pollution control equipment were used, and

(B) Are not limited to less than 91 Mg (100 tons) of VOM emissions per calendar year in the absence of air pollution control equipment, through production or capacity limitations contained in a federally enforceable construction permit or a SIP or FIP revision.

(ii) If a plant ceases to fulfill the criteria of paragraph (w)(1)(i) of this section, the requirements of paragraph (w) of this section shall continue to apply to a miscellaneous organic chemical manufacturing process emission source which was ever subject to the control requirements of paragraph (w)(3) of this section.

(iii) No limits under paragraph (w) of this section shall apply to emission sources with emissions of VOM to the atmosphere less than or equal to 0.91 Mg (1.0 ton) per calendar year if the total emissions from such sources not complying with paragraph (w)(3) of this section does not exceed 4.5 Mg (5.0 tons) per calendar year.

(iv) For the purposes of paragraph (w) of this section, an emission source shall be considered regulated by a subpart (of the Illinois rules) or paragraph if it is subject to the limits of that subpart (of the Illinois rules) or paragraph. An emission source is not considered regulated by a subpart (of the Illinois rules) or paragraph if its emissions are below the applicability cutoff level or if the source is covered by an exemption.

(v) For the purposes of paragraph (w) of this section, uncontrolled VOM emissions are the emissions of VOM which would result if no air pollution control equipment were used.

(2) Permit conditions. No person shall violate any condition in a permit when the condition results in exclusions of the plant or an emission source from paragraph (w) of this section.

(3) Control requirements. Every owner or operator of an emission source subject to paragraph (w) of this section shall comply with the requirements of paragraph (w)(3)(i) or (ii) of this section.

(i) Emission capture and control techniques which achieve an overall reduction in uncontrolled VOM emissions of at least 81 percent, or

(ii) An alternative control plan which has been approved by the Administrator as a SIP or FIP revision.

(4) Compliance schedule. Every owner or operator of an emission source subject to the control requirements of paragraph (w) of this section shall comply with the requirements of paragraph (w) of this section on and after July 1, 1991.

(5) Testing. Any owner or operator of a VOM emission source which is subject to paragraph (w) shall demonstrate compliance with paragraph (w)(3) of this section by using the applicable test methods and procedures specified in paragraph (a)(4) of this section.

(x) Other emission sources—(1) Applicability. (i) The requirements of paragraph (x) of this section shall apply to a plant's VOM emission sources, which are not included within any of the source categories specified in subpart (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or specified in paragraph (d), (e), (h), (i), (j), (q)(1), (s), (u), (v) or (w) of this section; if the plant is subject to paragraph (x) of this section. A plant is subject to paragraph (x) of this section if it contains process emission sources, not regulated by subpart (B), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), or (Z) of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or by paragraph (d), (e) of this section (excluding paragraph (e)(1)(i)(L)), (h) (excluding paragraph (h)(5)), (i), (j), or (q)(1) of this section; which as a group both:

(A) Have maximum theoretical emissions of 91 Mg (100 tons) or more per calendar year of VOM if no air pollution control equipment were used, and

(B) Are not limited to less than 91 Mg (100 tons) of VOM emissions per calendar year in the absence of air pollution control equipment, through production or capacity limitations contained in a federally enforceable construction permit or a SIP of FIP revision.

(ii) If a plant ceases to fulfill the criteria of paragraph (x)(1)(i) of this section, the requirements of paragraph (x) of this section shall continue to apply to an emission source which was ever subject to the control requirements of paragraph (x)(3) of this section.

(iii) No limits under paragraph (x) of this section shall apply to emission sources with emissions of VOM to the atmosphere less than or equal to 2.3 Mg (2.5 tons) per calendar year if the total emissions from such sources not complying with paragraph (x)(3) of this section does not exceed 4.5 Mg (5.0 tons) per calendar year.

(iv) For the purposes of paragraph (x) of this section, an emission source shall be considered regulated by a subpart (of the Illinois rules) or paragraph if it is subject to the limits of that subpart (of the Illinois rules) or paragraph. An emission source is not considered regulated by a subpart (of the Illinois rules) or paragraph of its emissions are below the applicability cutoff level or if the source is covered by an exemption.

(v) The control requirements in paragraphs (u), (v), (w), and (x) of this section shall not apply to sewage treatment plants, vegetable oil processing plants, coke ovens (including by-product recovery plants), fuel combustion sources, bakeries, barge loading facilities, jet engine test cells, pharmaceutical manufacturing, production of polystyrene foam insulation board (including storage and extrusion of scrap where blowing agent is added to the polystyrene resin at the plant), production of polystyrene foam packaging (not including storage and extrusion of scrap where blowing agent is added to the polystyrene resin at the plant), and iron and steel production.

(2) Permit conditions. No person shall violate any condition in a permit when the condition results in exclusion of the plant or an emission source from paragraph (x) of this section.

(3) Control requirements. Every owner or operator of an emission source subject to paragraph (x) of this section shall comply with the requirements of paragraph (x)(3) (i), (ii) or (iii) of this section.

(i) Emission capture and control equipment which achieve an overall reduction in uncontrolled VOM emissions of at least 81 percent, or

(ii) For coating lines, the daily-weighted average VOM content shall not exceed 0.42 kg VOM/l (3.5 lbs VOM/gal) of coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied during any day. Owners and operators complying with this paragraph are not required to comply with section 215.301 of 35 Ill. Adm. Code 215 (incorporated by reference as specified in 40 Cspan 52.742), or

(iii) An alternative control plan which has been approved by the Administrator as a SIP or FIP revision.

(4) Compliance schedule. Every owner or operator of an emissions source which is subject to paragraph (x) of this section shall comply with the requirements of paragraph (x) of this section on and after July 1, 1991.

(5) Testing. Any owner or operator of a VOM emission source which is subject to paragraph (x) of this section shall demonstrate compliance with paragraph (x)(3) of this section by using the applicable test methods and procedures specified in paragraph (a)(4) of this section.

(6) The control requirements in this paragraph apply to the varnish operations at the General Motors Corporation, Electro-Motive Division Plant (GMC Electro-Motive), LaGrange, Illinois, instead of the control requirements in paragraph (x)(3) of this section.

(i) After July 1, 1991, no coatings shall at any time be applied which exceed the following emission limitations for the specified coating.

(A) 8.0 lbs VOM per gallon of coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied at each coating applicator to coat Nomex rings. Such coating consists of Monsanto Skybond 705 Polyamide Resin (EMD P/N 9088817) and diluents. The Administrator must be notified at least 10 days prior to the use of any replacement coating(s) and/or diluents for coating Nomex rings.

(B) 6.8 lbs VOM per gallon of coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied at each coating applicator for any coatings not specified in paragraph (x)(6)(i)(A) of this section.

(ii) After July 1, 1991, the volume of coatings used shall not exceed the following:

(A) 600 gallons per year total for all coatings specified in paragraph (x)(6)(i)(A) of this section. The yearly volume of coatings used are to be calculated as follows:

(1) Compute the volume of specified coating used each month by the 15th of the following month.

(2) By the 15th of each month, add the monthly coating use for the 12 previous months (to obtain the yearly volume of coatings used).

(B) 28,500 gallons per year total for all coatings other than those specified in paragraph (x)(6)(i)(A) of this section. The yearly volume of coatings used are to be calculated as specified in paragraphs (x)(6)(ii)(A)(1) and (x)(6)(ii)(A)(2) of this section.

(iii) Beginning on July 1, 1991, the owner and operator of the General Motors Corporation Electro-Motive Division Plant in LaGrange, Illinois shall keep the following records for each month. All records shall be retained at General Motors for 3 years and shall be made available to the Administrator on request.

(A) The name and identification number of each coating as applied on any coating line within the varnish operation.

(B) The weight of VOM per volume and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each month on any coating line within the varnish operation.

(7) The control, recordkeeping, and monitoring requirements in this paragraph apply to the aluminum rolling mills at the Reynolds Metals Company's McCook Sheet & Plate Plant in McCook, Illinois (Cook County) instead of the control requirements and test methods in the other parts of paragraph (x), and the recordkeeping requirements in paragraph (y) of this section. All of the following requirements must be met by Reynolds on and after July 7, 1995.

(i) Only organic lubricants with initial and final boiling points between 460 degrees F and 635 degrees F, as determined by a distillation range test using ASTM method D86-90, are allowed to be used at Reynolds' aluminum sheet cold rolling mills numbers 1 and 7. All incoming shipments of organic lubricant for the number 1 and 7 mills must be sampled and each sample must undergo a distillation range test to determine the initial and final boiling points using ASTM method D86-90. A grab rolling lubricant sample shall be taken from each operating mill on a monthly basis and each sample must undergo a distillation range test, to determine the initial and final boiling points, using ASTM method D86-90.

(ii) An oil/water emulsion, with no more than 15 percent by weight of petroleum-based oil and additives, shall be the only lubricant used at Reynolds' aluminum sheet and plate hot rolling mills, 120 inch, 96 inch, 80 inch, and 145 inch mills. A grab rolling lubricant sample shall be taken from each operating mill on a monthly basis and each sample shall be tested for the percent by weight of petroleum-based oil and additives by ASTM Method D95-83.

(iii) The temperature of the inlet supply of rolling lubricant for aluminum sheet cold rolling mills numbers 1 and 7 shall not exceed 150 °F, as measured at or after (but prior to the lubricant nozzles) the inlet sump. The temperature of the inlet supply of rolling lubricant for the aluminum sheet and plate hot rolling mills, 120 inch, 96 inch, 80 inch, and 145 inch mills shall not exceed 200 °F, as measured at or after (but prior to the lubricant nozzles) the inlet sump. Coolant temperatures shall be monitored at all the rolling mills by use of thermocouple probes and chart recorders or electronic data recorders.

(iv) All distillation test results for cold mill lubricants, all percent oil test results for hot mill lubricants, all coolant temperature recording charts and/or temperature data obtained from electronic data recorders, and all oil/water emulsion formulation records, shall be kept on file, and be available for inspection by USEPA, for three years.

(8) The control and recordkeeping requirements in this paragraph apply to the silk screen presses and associated ovens, cleaning operations and laminators at Parisian's Novelty Company (Parisian), Chicago, Illinois, facility, instead of the control requirements in paragraphs (x)(8) (u)(3) and (x)(3) of this section and the recordkeeping requirements in paragraph (x)(8)(y) of this section.

(i) After March 1, 1993, no coatings or inks shall at any time be applied, at any coating or ink applicator, which exceed the following emission limitations for the specified coating or ink.

(A) 6.65 pounds (lbs) volatile organic material (VOM) per gallon of ink (minus water and any compounds which are specifically exempted from the definition of VOM) as applied on Parisian's silk screen presses.

(B) 6.4 lbs VOM per gallon of adhesive coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied on Parisian's laminators. Such adhesive is identified as MIX #963.

(ii) After March 1, 1993, the volume of coating and ink used shall not exceed the following:

(A) 2,556 gallons per year total for all inks. The yearly volume of inks used is to be calculated as follows:

(1) Compute the volume of ink used each month by the 15th of the following month.

(2) By the 15th of each month, add the monthly ink usage for the 12 previous months (to obtain the yearly volume of ink used).

(B) 780 gallons per year total for all coatings specified in paragraph (x)(8)(i)(B) of this section. The yearly volume of coatings used are to be calculated as specified in paragraphs (x)(8)(ii)(A)(1) and (x)(8)(ii)(A)(2) of this section.

(iii) Beginning on March 1, 1993, the owner and operator of Parisian's plant in Chicago, Illinois, shall keep the following records for each month. All records shall be retained at Parisian for 3 years and shall be made available to the Administrator on request.

(A) The name and identification number of each coating as applied on any laminator.

(B) The weight of VOM per volume and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each month on any laminator.

(C) The weight of VOM per volume and the volume of each type of ink (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each month on any screen press.

(iv) After March 1, 1993, no more than 84 gallons per year of denatured alcohol may be used for cleaning labels at Parisian. The yearly volume of denatured alcohol used is to be calculated as specified in paragraphs (x)(8)(ii)(A)(1) and (x)(8)(ii)(A)(2) of this section. Beginning on March 1, 1993, Parisian shall keep monthly records of the type, volume, and VOM content of all solvents used for label cleaning. These records shall be retained at Parisian for 3 years and shall be made available to the Administrator on request.

(v) After March 1, 1993, no more than 7,932 gallons per year of screen wash #956 may be used on Parisian's screen cleaner. The yearly volume of screen wash #956 used is to be calculated as specified in paragraphs (x)(8)(ii)(A)(1) and (x)(8)(ii)(A)(2) of this section. Beginning on March 1, 1993, Parisian shall keep monthly records of the type, volume, and VOM content of all cleaning compounds used on Parisian's screen cleaner. These records shall be retained at Parisian for 3 years and shall be made available to the Administrator on request.

(vi) After March 1, 1993, only those cleaners specifically identified in paragraphs (x)(8)(iv) and (x)(8)(v) of this section may be used at Parisian.

(9) The control requirements in this paragraph apply to the process sources listed in paragraph (x)(9)(i)(A) of this section at the Nalco Chemical Company facility in Bedford Park, Illinois, instead of the control requirements in paragraph (x)(3) of this section.

(i) Production and Operation Restrictions.

(A) On and after October 1, 1992, the maximum volatile organic compound (VOC) emissions per batch, the 12-month rolling average number of batches per year, and the peak limit of batches per month shall not exceed the following limits:

Source Maximum VOC emissions, lb/batch 12-mo. rolling average limit batch/yr Peak batch limit, batch/month (1) System 1 charge0.1628033 System 1 purge1.35 (2) 24-T-156, 1572.6030033 (3) 28-T-217, 2340.2340245 (4) 28-T-214-2165.7060365 (5) 20-R-182, 1850.02728 (6) 20-R-1300.0734038 (7) 20-R-1550.2125429 (8) 20-WT-1740.2125429 (9) 12-T-97-994.6E-4 lb/hr8,760 hr/yr744 hr/mo (10) 12-T-954.0E-6 lb/hr8,760 hr/yr744 hr/mo (11) 12-T-967.7E-5 lb/hr8,760 hr/yr744 hr/mo (12) 12-T-67, 730.003 lb/hr8,760 hr/yr744 hr/mo (13) 20-T-121-1220.8531234 (14) 20-T-123-1255.461668 (15) 20-T-140, 1428.060065 (16) 20-T-1590.3141646 (17) 20-R-193, 2009.854059 (18) 32-R-3000.1836541 (19) 32-T-3020.2136541 (20) 32-T-3040.2173081 (21) 32-T-3140.2336541 (22) 32-T-3220.2136541 (23) 32-T-3280.2336541 (24) 10-T-610.001365—containing organic31—containing organic (25) 24-T-441, 1660.1273081 (26) 25-T-284, 440, 443-4440.2873081 (27) 25-T-1704E-610412 (28) Tank truck loading0.12 lb/truck1,600 trucks/yr134 trucks/mo (29) System 20.3628033 (30) System 42.8828033 (31) 25-R-1640.1036541 (32) 25-R-2050.1436541 (33) Drum station3.511,005110 (34) V-4SAC1.5625429 (35) 20-CT-15513.9025429 (36) 12-SE-1001.10 lb/hr8,760 hr/yr744 hr/mo (37) Drum exhaust hood A1.00365—involving use of organic material31—involving use of organic material (38) 24-T-2300.9873081 (39) 8-CT-10.002 lb/hr8,760 hr/yr744 hr/mo (40) 9-CT-10.002 lb/hr8,760 hr/yr744 hr/mo (41) 10-CT-10.005 lb/hr8,760 hr/yr744 hr/mo (42) 22-CT-10.003 lb/hr8,760 hr/yr744 hr/mo (43) 25-CT-10.005 lb/hr8,760 hr/yr744 hr/mo (44) 25-CT-20.002 lb/hr8,760 hr/yr744 hr/mo (45) 29-CT-10.002 lb/hr8,760 hr/yr744 hr/mo (46) 32-CT-10.005 lb/hr8,760 hr/yr744 hr/mo (47) 36-CT-10.002 lb/hr8,760 hr/yr744 hr/mo (48) 32-T-3250 a36541 (49) 26-R-1950.1 a36541 (50) Continuous polymer-blending0.1 lb/hr a2,000 hr/yr (51) Portafeed washer booth 10.84 lb/hr b4,160 hr/yr744 hr/mo (52) Portafeed washer booth 20.84 lb/hr b8,736 hr/yr744 hr/mo (53) 32-T-3924.4E-710412

a Assumed value.

b Based on monitoring data.

(B) The following equation shall be used to calculate maximum VOC emissions per batch for the process sources listed in paragraphs (x)(9)(i)(A)(1) (charge only and (2) through (28) and (53) of this section:

Where: ER = VOC emission rate; Qo = Quantity of organic per batch or charge rate; Mv = Molecular weight of the volatile component; P = Partial pressure of the volatile component for mixtures of liquid made up with more than one chemical; or vapor pressure for pure liquids made up of only one organic chemical; and Constant 1 = (7.45 gal/ft 3) × (385 ft 3/mole)x(760 mmHg).

(C) The following equation shall be used to calculate the VOC emissions per batch from the process sources listed in paragraph (x)(9)(i)(A)(1) of this section (purge only) and (29) through (32) of this section:

Where: PR = Nitrogen purge rate; and Constant 2 = (385 ft 3/mole) × (760 mmHg).

(D) The following equation shall be used to calculate the VOC emissions per batch from the drum station listed at paragraph (x)(9)(i)(A)(33) of this section:

ER(1b/batch) = (0.40 × [ER28-T-217-218]) + (0.60 × [ER28-T-214-216])

(E) The following equation shall be used to calculate the VOC emissions per batch from the V-4SAC listed at paragraph (x)(9)(i)(A)(34) of this section:

Where: span1mmHg = Maximum air flow rate to maintain 1 mmHg; Ma = Molecular weight of air; and Pv2 = Vapor pressure of organic at 65 °F and 760 mmHg.

(F) The following equation shall be used to calculate the VOC emissions per batch from 20-CT-155 listed at paragraph (x)(9)(i)(A)(35) of this section:

Where: ERtot = Total system emission rate calculated using the following equation: Where: Pv1 = Vapor pressure of organic at 200 °F and 350 mmHg.

(G) The following equation shall be used to calculate the VOC emissions per hour from 12-SE-100 listed at paragraph (x)(9)(i)(A)(36) of this section:

ER(lb/hr) = Evap (gm/cm 2 sec) × area (cm 2) × 3600 sec/hr Where: Evap = Evaporation rate from a surface 8.93 cm × 8.9 cm (lb/[cm 2] [sec]) calculated using the following equation: Evap = 10−7 Mv0.71 × [0.034 (Pe − Pd) 1.25 + 156 (Pe − Pd)] Where: Pe = Partial pressure of the component from the spilled liquid; Pd = Partial pressure of the component in the incident air stream, assumed to be 0 mmhg; and Area = Surface area of the liquid.

(H) The following equation shall be used to calculate the VOC emissions per batch from the drum exhaust hood A listed at paragraph (x)(9)(i)(A)(37) of this section:

Where: span = Air flow rate. (I) The following equation shall be used to calculate the VOC emissions per batch from 24-T-230 listed at paragraph (x)(9)(i)(A)(38) of this section: Where: VH = Head space volume at heated temperature 135 °F; VA = Head space volume at ambient temperature 68 °F; PP135 °F = Partial pressure of volatile component at 135 °F. Constant 3 = (434 ft 3/mole)(7.45 gal/ft 3) × (760 mmHg)

(J) The following equations shall be used to calculate the VOC emissions per batch from the process sources listed in paragraph (x)(9)(i) (39) through (47) of this section:

Where: VR = Refill volume; t = Time between refills; org = Fraction of organic component in product; CB = Concentration of chemical B fed 3 times/week; VT = Tower volume; dB = Density of chemical B; CC = Concentration of chemical C fed continuously; Evap = Evaporation rate; and dc = Density of chemical C.

(K) The number of batches for each process source shall be calculated as follows:

(1) Compute the monthly number of batches for each process source by the 15th day of the following month.

(2) By the 15th day of each month, add the monthly number of batches for each process source for the 12 previous months to obtain the total number of batches per year.

(ii) Recordingkeeping. (A) On and after October 1, 1992, the owner and operator of the Nalco Chemical Company facility in Bedford Park, Illinois, shall keep the following records for all process sources listed in paragraphs (x)(9)(i)(A) (1) through (53) of this section. These records shall be maintained for the units specified in paragraphs (x)(9)(i) (A) through (K) of this section, be compiled on a monthly basis, be retained at the facility for a period of 3 years, and be made available to the Administrator upon request.

(B) [Reserved]

(1) Calculations of the pounds per batch or pounds per hour (as appropriate) for each batch for each process source. This includes the information necessary for each calculation.

(2) The monthly number of batches for each process source.

(3) The total number of batches per year for the 12 previous months for each process source.

(10) The control requirements in this paragraph apply to the storage tanks listed in paragraph (x)(10)(i)(A) of this section at the Nalco Chemical Company facility in Bedford Park, Illinois, instead of the control requirements in paragraph (x)(3) of this section.

(i) Production and Operation Restrictions. (A) On and after October 1, 1992, the product of the molecular weight of vapor in each storage tank (Mv), the true vapor pressure at bulk liquid conditions for each tank (P), and the paint factor (Fp); the storage tank maximum yearly throughput for each tank; and the maximum monthly throughput for each tank shall not exceed the following limits:

Tank No. MV × P × Fp, (lb) (mmhg)/lb-mole Yearly throughput, gal/yr Monthly throughput, gal/month (1) 24-T-14745.456,2504,688 (2) 24-T-150227266,45022,204 (3) 24-T-151227266,45022,204 (4) 24-T-158N18.9173,83014,486 (5) 24-T-158C18.0110,1909,183 (6) 24-T-158S1.1752,0104,334 (7) 24-T-160226.8266,45022,204 (8) 24-T-161227182,45015,204 (9) 24-T-16247393,9007,825 (10) 20-T-1013.7290,2907,525 (11) 20-T-1021.80122,90010,242 (12) 20-T-10342023,9601,997 (13) 20-T-104180475,90039,659 (14) 20-T-10537052,3604,363 (15) 20-T-1061,210623,10051,926 (16) 20-T-10729490,0407,503 (17) 20-T-1081,36081,4706,789 (18) 20-T-1091,390167,06013,922 (19) 20-T-15318035,0002,917 (20) 20-T-131 a(21) 20-T-132 a(22) 20-T-133 a(23) 20-T-134 a(24) 20-T-135 a(25) 20-T-13629.5307,71026,580 (26) 20-T-137 a(27) 20-T-13829.5307,71026,580 (28) 32-T-305288785,55065,462 (29) 32-T-30666.5165,35013,779 (30) 32-T-30766.5294,75024,563 (31) 32-T-30866.5128,47010,706 (32) 32-T-31066.577,2906,441 (33) 32-T-31166.5182,13015,177 (34) 32-T-31950.0688,95057,413 (35) 32-T-32050.0688,95057,413 (36) 32-T-32670.0248,44020,703 (37) 32-T-33170.0489,54040,795 (38) 32-T-33270.070,3805,865 (39) 32-T-33370.0270,85022,571 (40) 32-T-33470.0210,61018,267 (41) 32-T-33570.0418,20034,850 (42) 32-T-33670.0632,46052,706 (43) 32-T-33779853,8504,488 (44) 17-T-20627,000300,76025,063 (45) 17-T-20827,000300,76025,063 (46) 17-T-2072.48180,18015,016 (47) 17-T-2092.48180,18015,016 (48) 24-T-515331216,86018,072 (49) 25-T-2821.421,920,410160,034 (50) 25-T-2831.421,920,410160,034 (51) 24-T-44218.090,9907,583 (52) 17-T-21047.9582,99048,583 (53) 17-T-21147.9582,99048,583 (54) 17-T-212508728,42060,702 (55) 17-T-213508728,42060,702 (56) 17-T-40150.0131,97010,998 (57) 17-T-40215.0120,16010,014 (58) 17-T-4036.20127,77010,648 (59) 17-T-40426.51,601,510133,460 (60) 17-T-40550.0113,8309,486 (61) 17-T-40640.0231,03019,253 (62) 17-T-407206135,18011,265 (63) 17-T-409395327,41027,285 (64) 17-T-410395129,29010,774 (65) 17-T-41150.0213,87017,843 (66) 17-T-41250.0277,84023,153 (67) 17-T-41450.072,9206,077 (68) 17-T-41550.056,1404,678 (69) 17-T-416395393,55032,796 (70) 17-T-41723.4233,78019,482 (71) 17-T-418115873,27072,773 (72) 17-T-419119278,46023,205 (73) 17-T-420112730,78060,898 (74) 17-T-42125.2300,01025,001 (75) 17-T-422115873,27072,773 (76) 17-T-42323.4215,06017,922 (77) 17-T-42423.4209,61017,468 (78) 26-T-21850.064,8905,408 (79) 26-T-2191.50197,90016,492 (80) 26-T-2202,460160,02013,336 (81) 26-T-22150.074,8206,235 (82) 26-T-22280.066,5905,550 (83) 26-T-2244.80225,29018,774 (84) 26-T-22550.036,6103,051 (85) 26-T-22629447,3903,949 (86) 26-T-22750.063,0405,253 (87) 26-T-228500136,15011,346 (88) 26-T-22950.0112,9709,414 (89) 26-T-23123.4319,61026,634 (90) 26-T-232117564,28047,024 (91) 26-T-23323.4539,70044,975 (92) 27-T-24521.6361,97030,165 (93) 27-T-246348141,82011,818 (94) 27-T-24723.471,6705,972 (95) 27-T-24819896,0108,001 (96) 27-T-24992751,2404,270 (97) 27-T-250110433,03036,086 (98) 27-T-25139645,4403,787 (99) 27-T-25221.6171,37014,281 (100) 27-T-253348237,90019,825 (101) 26-T-19210.0117,9509,829 (102) 27-T-2780.6274,9106,243 (103) 27-T-2790.18583,76048,647 (104) 27-T-28521.6459,53038,294 (105) 27-T-28621.6459,53038,294 (106) 25-T-20119.8143,55011,963 (107) 32-T-3880.07499,34041,612 (108) 32-T-3890.07499,34041,612 (109) 32-T-390288808,310583,340 (110) 32-T-3911.42800,00583,340

a Tank not in use.

(B) The throughput shall be calculated as follows:

(1) Compute the monthly throughput for each tank by the 15th day of the following month.

(2) By the 15th day of each month, add the monthly throughputs for the 12 previous months to obtain the yearly throughput.

(ii) Recordkeeping. (A) On and after October 1, 1992, the owner and operator of the Nalco Chemical Company facility in Bedford Park, Illinois, shall keep the following records for all storage tanks. These records shall be compiled on a monthly basis, be retained at the facility for a period of 3 years, and be made available to the Administrator upon request.

(1) The molecular weight of vapor in each storage tank (Mv), the true vapor pressure at bulk liquid conditions for each tank (P), the paint factor (Fp), and their product. Fp shall be determined from Table 4.3-1 of “Compilation of Air Pollutant Emission Factors, Volume I: Stationary Point and Area Sources,” AP-42, September 1985.

(2) The monthly throughput.

(3) The total throughput per year for the 12 previous months.

(B) [Reserved]

(iii) Test Methods. (A) The true vapor pressure at bulk liquid temperature shall be determined by using the procedures specified in paragraph (a)(8) of this section.

(B) The molecular weight of vapor in the storage tank shall be determined by using Table 4.3-2 “Compilation of Air Pollutant Emission Factors, Volume I: Stationary Point and Area Sources,” AP-42, September 1985, or by analysis of vapor samples. Where mixtures of organic liquids are stored in a tank, Mv shall be estimated from the liquid composition using the following equation:

Where: Ma = Molecular weight of pure component a; Pa = Vapor pressure of pure component a; Xa = Mole fraction of pure component a in the liquid; Mb = Molecular weight of pure component b; Pb = Vapor pressure of pure component b; Xb = Mole fraction of pure component b in the liquid; and Pt = Pa X2= Pb Xb.

(11) The control requirements in this paragraph apply to the fugitive emission sources listed in paragraph (x)(11)(i)(A) of this section at the Nalco Chemical Company facility in Bedfore Park, Illinois, instead of the control requirements in paragraph (x)(3) of this section.

(i) Production and Operation Restrictions.

(A) On and after October 1, 1992, all components (e.g., pumps, valves, flanges, pressure relief valves (PRV's), and open end lines) at the specified locations (e.g., Building 32—Tube Reactor System, etc.), and in the specified type of service (e.g., heavy liquid stratified, light liquid stratified, etc.) shall be limited by the maximum monthly hours in the following table:

(ii) Recordkeeping.

(A) On and after October 1, 1992, the owner and operator of the Nalco Chemical Company facility in Bedford Park, Illinois, shall keep the following records for all fugitive emission sources. These records shall be compiled on a monthly basis, be retained at the facility for a period of 3 years, and be made available to the Administrator upon request.

(1) The total number of hours of organic service for each component at each location specified in paragraphs (x)(11)(i)(A) (1) through (10) of this section.

(2) The vapor pressure of each organic compound in each component at each location specified in paragraphs (x)(11)(i)(A) (1) through (10) of this section.

(B) [Reserved]

(12) The control and recordkeeping and reporting requirements, as well as the test methods in this paragraph, apply to the gravure and screen press operations at the Meyercord Corporation (Meyercord) in Carol Stream, Illinois, instead of the requirements in paragraphs (x)(1) through (x)(5) of this section.

(i) After July 1, 1991, no materials which contain volatile organic material (VOM), including coatings, inks, and cleaning material, may be used at any gravure or screen press unless the total VOM emissions remain below 100 tons of VOM for every consecutive 365-day period, or fraction thereof, starting on July 1, 1991. A new 365-day period starts on each day. The VOM emissions, which are to be calculated on a daily basis, are to be added to the VOM emissions for the prior 364 days (but not including any day prior to July 1, 1991). VOM emissions are based upon the VOM content of the material and the volume of material used. The effect of add-on control equipment is not considered in calculating VOM emissions; that is, the VOM emissions are to be determined as if the press(es) do(es) not have add-on control equipment. The applicable test methods and procedures specified in paragraph (a)(4) of this section are to be used in determining daily VOM emissions.

(ii) The VOM content of each coating, ink, and cleaning solution shall be determined by the applicable test methods and procedures specified in paragraph (a)(4) of this section to establish the records required under paragraph (x)(12)(ii) of this section. Beginning on July 1, 1991, the owner or operator of the subject presses shall collect and record all of the following information each day and maintain the information at the facility for 3 years:

(A) The name and identification number of each coating, ink, and cleaning solution as applied on any press.

(B) The pounds (lbs) of VOM per gallon of each coating, ink, and cleaning solution (minus water and any compounds which are specifically exempted from the definition of VOM) as applied on any press.

(C) The total gallons of each coating, ink, and cleaning solution (minus water and any compounds which are specifically exempted from the definition of VOM) used per day.

(D) The total lbs of VOM contained in the volume of each coating, ink, and cleaning solution used per day on any press. The lbs of VOM per day is to be calculated by multiplying the lbs of VOM per gallon (minus water and any compounds which are specifically exempted from the definition of VOM) times the gallons (minus water and any compounds which are specifically exempted from the definition of VOM) used per day.

(E) The total lbs of VOM per day from all coatings, inks, and cleaning solutions used on all presses. The total lbs of VOM per day is to be obtained by adding the lbs of VOM per day contained in all coatings, inks, and cleaning solutions.

(F) Within 7 days after each 365-day period, the VOM emissions (as calculated in paragraph (x)(12)(ii)(E)) of this section before add-on control, from the 365-day period, are to be determined.

Starting on July 7, 1992, VOM emissions are to be determined for the 365 days ending 7 days earlier. Each day concludes a new 365-day period. However, no VOM emissions are to be included for any days prior to July 1, 1991. For example, on July 17, 1991, the emissions from July 1, through July 10, 1991, are to be included, whereas on January 7, 1994, the emissions from January 1, 1993, through December 31, 1993, are to be included.

(13) The control and recordkeeping and reporting requirements, as well as the test methods in this paragraph, apply to the sheet fed cold set presses and web heatset presses at the Wallace Computer Services, Inc. (Wallace) printing and binding plant in Hillside, Illinois, instead of the requirements in 40 Cspan 52.741(h) and 40 Cspan 52.741(x)(1) through 40 Cspan 52.741(x)(5).

(i) After July 1, 1991, no inks shall at any time be applied, at the presses indicated below, which exceed the pounds (lbs) volatile organic material (VOM) per gallon of ink (minus water and any compounds which are specifically exempted from the definition of VOM) limit established for each press. After July 1, 1991, the yearly volume of ink used at each press, in gallons of ink (minus water and any compounds which are specifically exempted from the definition of VOM) per year, shall not exceed the gallons per year limit established below for each press. The yearly volume of ink used per press is to be calculated according to the procedure in paragraph (x)(13)(iii) of this section.

Press Lbs VOM/gallon ink Gallons/year ink 141.68276 161.681896 223.012712 233.0113140 253.0112720 263.014764

(ii) After July 1, 1991, no materials (other than those inks subject to the limits in paragraph (x)(13)(i)) of this section, shall at any time be applied or used, at the presses indicated below, which exceed the lbs VOM per gallon of material (minus water and any compounds which are specifically exempted from the definition of VOM) limit established for each press. After July 1, 1991, the yearly volume of material (excluding ink and water) used at each press, in gallons of material (minus water and any compounds which are specifically exempted from the definition of VOM) per year, shall not exceed the gallons per year limit established for each press. The yearly volume of material (excluding ink and water) used per press is to be calculated according to the procedure in paragraph (x)(13)(iii) of this section.

Press Lbs VOM/gallon material Gallons/year material 146.9612 166.98,340 227.1360 237.1480 257.1516 267.11,848

(iii) The yearly volume of ink/material used is to be calculated as follows:

(A) Compute the volume of ink/material used each month per press by the 15th of the following month.

(B) By the 15th of each month, add the monthly ink/material usage per press for the 12 previous months (to obtain the yearly volume of ink used).

(iv) Beginning on July 1, 1991, the owner and operator of Wallace's plant in Hillside, Illinois, shall keep the following records for each press for each month. All records shall be retained by Wallace for 3 years and shall be made available to the Administrator on request:

(A) The name and identification number of each ink, fountain solution, fountain solution additive, cleaning solvent, and other VOM containing material as applied or used.

(B) The weight of VOM per volume of each ink, fountain solution, fountain solution additive, cleaning solvent, and each other VOM containing material (minus water and any compounds which are specifically exempted from the definition of VOM) as applied or used each month.

(C) The volume of ink (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each month.

(D) The total volume of miscellaneous VOM containing materials (minus water and any compounds which are specifically exempted from the definition of VOM), other than inks, that are used each month.

(v) Any record showing a violation of paragraph (x)(13)(i) or (x)(13)(ii) of this section shall be reported by sending a copy of such record to the Administrator within 30 days of the violation.

(vi) To determine compliance with paragraphs (x)(13)(i) and (x)(13)(ii) of this section and to establish the records required under paragraph (x)(13)(iv) of this section the VOM content of each ink and miscellaneous VOM containing material shall be determined by the applicable test methods and procedures specified in paragraph (a)(4) of this section.

(14) The control and recordkeeping and reporting requirements, as well as the test methods in this paragraph, apply to the power-operated silk screen presses, the hand screen presses, the screen adhesive printing lines, the Andreotti rotogravure press, the Halley Rotogravure press, and the Viking press at the American Decal and Manufacturing Company's plant in Chicago, Illinois, instead of the requirements in paragraphs (h) and (x)(1) through (x)(5) of this section. The emissions from the sources listed above (in paragraph (x)(14) of this section) are to be included in the calculation of “maximum theoretical emissions” for determining applicability for any other sources (for which applicability is based on the quantity of maximum theoretical emissions) at American Decal and Manufacturing Company's Chicago plant not included in paragraph (x)(14) of this section.

(i) After July 24, 1992, no inks, coatings, thinner, clean-up material or other VOC-containing material shall at any time be applied, at the presses/printing lines listed above (in paragraph (x)(14) of this section), which exceed the VOC content (in percent by weight VOC) limit established below. After July 24, 1992, the yearly usage (in weight of material applied) of ink, coating, thinner, clean-up material, and other VOC-containing material, shall not exceed the applicable pounds per year limit established below. The yearly weight of ink, coating, thinner, clean-up material, and other VOC-containing material is to be calculated according to the procedure in paragraph (x)(14)(ii) of this section.

Material Usage
(lbs/yr)
Weight Percent VOC #6 ink9,07656.8 #7 ink1,27854.2 #2 ink2,91172.7 Blue N.C. lacq.39464.3 Black M lacq.75361.6 4B9L Clear2,45177.1 4B9L H Clear3,36075.0 Flow-Out Agent1,79597.1 D.S. Stamp lacq.1,04762.0 Dull write-on8671.6 AH-1662184.5 Thinner (#7,6)2,350100.0 Exon 4701,66865.4 9L Clear2,45177.1 White M lacq3,46747.0 Tedlar Gr. Vehicle1,05066.7 TH-9822,04773.2 TH-575969.5 TH-14M16,5200.7 PS 16010,6443.0 #1 tint4,87269.3 #2 tint4,25683.7 Roto Color13,88462.0 1st SS White25,74051.5 2nd SS White25,74051.5 Clean Up108,742100.0 Other Materials400100.0

(ii) The yearly weight of material used is to be calculated as follows:

(A) Compute the weight of each ink, coating, thinner, clean-up material, and other VOC-containing material used each month by the 15th of the following month.

(B) By the 15th of each month, add the monthly usage (in pounds) for each ink, coating, thinner, clean-up material, and other VOC-containing material for the twelve previous months (to obtain the yearly weight of each ink, coating, thinner, clean-up material used). A comparison of these yearly usage levels (in pounds) with purchase records must be made to ensure the accuracy of the monthly usage levels (in pounds) obtained to satisfy paragraph (x)(14)(ii)(A) of this section.

(iii) Beginning on August 1, 1992, the owner and operator of the American Decal and Manufacturing Company plant in Chicago, Illinois, shall keep the following records for each ink, coating, thinner, clean-up material, and other VOC-containing material for each month. All records shall be kept by the American Decal and Manufacturing Company for 3 years and shall be made available to the Administrator on request:

(A) The name and identification number of each ink, coating, thinner, clean-up material, and other VOC-containing material as applied or used.

(B) The weight percent VOC of each ink, coating, thinner, clean-up material, and each other VOC-containing material as applied or used each month.

(C) The as applied weight of each ink, coating, thinner, clean-up material, and other VOC-containing material used each month.

(iv) Any record showing a violation of paragraph (x)(14)(i) of this section after October 20, 1995 shall be reported by sending a copy of such record to the Administrator within 30 days of the violation.

(v) To determine compliance with paragraph (x)(14)(i) of this section and to establish the records required under paragraph (x)(14)(iii) of this section, the weight percent VOC of each ink, coating, thinner, clean-up material, and other VOC-containing material shall be determined by the applicable test methods and procedures specified in paragraph (a)(4) of this section. Any material reported to be 100 percent VOC does not have to be tested for weight percent VOC.

(y) Recordkeeping and reporting for non-CTG sources—(1) Exempt emission sources. Upon request by the Administrator, the owner or operator of an emission source which is exempt from the requirements of paragraphs (u), (v), (w), (x), or (e)(3)(ii) of this section shall submit records to the Administrator within 30 calendar days from the date of the request that document that the emission source is exempt from those requirements.

(2) Subject emission sources. (i) Any owner or operator of a VOM emission source which is subject to the requirements of paragraph (u), (v), (w) or (x) of this section and complying by the use of emission capture and control equipment shall comply with the following:

(A) By July 1, 1991, or upon initial start-up of a new emission source, the owner or operator of the subject VOM emission source shall perform all tests and submit to the Administrator the results of all tests and calculations necessary to demonstrate that the subject emission source will be in compliance on and after July 1, 1991, or on and after the initial start-up date.

(B) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a subject VOM emission source shall collect and record all of the following information each day and maintain the information at the facility for a period of three years:

(1) Control device monitoring data.

(2) A log of operating time for the capture system, control device, monitoring equipment and the associated emission source.

(3) A maintenance log for the capture system, control device and monitoring equipment detailing all routine and non-routine maintenance performed including dates and duration of any outages.

(C) On and after July 1, 1991, the owner or operator of a subject VOM emission source shall notify the Administrator in the following instances:

(1) Any record showing a violation of the requirements of paragraphs (u), (v), (w), or (x) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(2) At least 30 calendar days before changing the method of compliance with paragraphs (u) or (x) of this section from the use of capture systems and control devices to the use of complying coatings, the owner or operator shall comply with all requirements of paragraph (y)(2)(ii)(A) of this section. Upon changing the method of compliance with paragraphs (u) or (x) of this section from the use of capture systems and control devices to the use of complying coatings, the owner or operator shall comply with all requirements of paragraph (y)(2)(ii) of this section.

(ii) Any owner or operator of a coating line which is subject to the requirements of paragraphs (u) or (x) of this section and complying by means of the daily-weighted average VOM content limitation shall comply with the following:

(A) By July 1, 1991, or upon initial start-up of a coating line subject to paragraph (u) or (x) of this section; the owner or operator of the subject coating line shall certify to the Administrator that the coating line will be in compliance on and after July 1, 1991, or on and after the initial start-up date. Such certification shall include:

(1) The name and identification number of each coating line which will comply by means of the daily-weighted average VOM content limitation.

(2) The name and identification number of each coating as applied on each coating line.

(3) The weight of VOM per volume and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line.

(4) The instrument or method by which the owner or operator will accurately measure or calculate the volume of each coating as applied each day on each coating line.

(5) The method by which the owner or operator will create and maintain records each day as required in paragraph (y)(2)(ii)(B) of this section.

(6) An example of the format in which the records required in paragraph (y)(2)(ii)(B) of this section will be kept.

(B) On and after July 1, 1991, or on and after the initial start-up date, the owner or operator of a subject coating line shall collect and record all of the following information each day for each coating line and maintain the information at the facility for a period of three years:

(1) The name and identification number of each coating as applied on each coating line.

(2) The weight of VOM per volume and the volume of each coating (minus water and any compounds which are specifically exempted from the definition of VOM) as applied each day on each coating line.

(3) The daily-weighted average VOM content of all coatings as applied on each coating line as defined in paragraph (a)(3) of this section.

(C) On and after July 1, 1991, the owner or operator of a subject coating line shall notify the Administrator in the following instances:

(1) Any record showing violation of the requirements of paragraph (u) or (x) of this section shall be reported by sending a copy of such record to the Administrator within 30 days following the occurrence of the violation.

(2) At least 30 calendar days before changing the method of compliance with paragraph (u) or (x) of this section from the use of complying coatings to the use capture systems and control devices, the owner or operator shall comply with all requirements of paragraph (y)(2)(i)(A) of this section. Upon changing the method of compliance with paragraphs (u) or (x) of this section from the use of complying coatings to the use capture systems and control devices, the owner or operator shall comply with all requirements of paragraph (y)(2)(i) of this section.

(iii) Any owner or operator of a VOM emission source which is subject to the requirements of paragraphs (u), (v), (w) or (x) of this section and complying by means of an alternative control plan which has been approved by the Administrator as a SIP or FIP revision shall comply with the recordkeeping and reporting requirements specified in the alternative control plan.

(z) Rules stayed. Not withstanding any other provision of this subpart, the effectiveness of the following rules is stayed as indicated below.

(1) [Reserved]

(2) Compliance with all of 40 Cspan 52.741 is stayed for 60 days (July 1, 1991, until August 30, 1991) as it pertains to the following parties: The Illinois Environmental Regulatory Group including its approximately 40 member firms; Allsteel, Incorporated; Riverside Laboratories, Incorporated; the Printing Industry of Illinois/Indiana Association including its member firms, and R.R. Donnelley & Sons Company; the rules applicable to General Motors Corporation; Reynolds Metals Company; Stepan Company; and Duo-Fast Corporation. Final compliance for these parties is extended 60 days from July 1, 1991 until August 30, 1991.

(3) The following rules are stayed from July 23, 1991, until USEPA completes its reconsideration as indicated:

(i) 40 Cspan 52.741(e) only as it applies to Duo-Fast Corporation's Franklin Park, Illinois “power-driven metal fastener” manufacturing facility, and

(ii) 40 Cspan 52.741 (w) and (y) only as it applies to Stepan Company's miscellaneous organic chemical manufacturing processes at its manufacturing facility located near Millsdale, Illinois.

When USEPA concludes its reconsideration, it will publish its decision and any actions required to effectuate that decision in the Federal Register.

(4)-(5) [Reserved]

Appendix A to § 52.741—List of Chemicals Defining Synthetic Organic Chemical and Polymer Manufacturing
OCPDB No. 1Chemical 20Acetal. 30Acetaldehyde. 40Acetaldol. 50Acetamide. 65Acetanilide. 70Acetic acid. 80Acetic anhydride. 90Acetone. 100Acetone cyanohydrin. 110Acetonitrile. 120Acetophenone. 125Acetyl chloride. 130Acetylene. 140Acrolein. 150Acrylamide. 160Acrylic acid & esters. 170Acrylonitrile. 180Adipic acid. 185Adiponitrile. 190Alkyl naphthalenes. 200Allyl alcohol. 210Allyl chloride. 220Aminobenzoic acid. 230Aminoethylethanolamine. 235p-aminophenol. 240Amyl acetates. 250Amyl alcohols. 260Amyl amine. 270Amyl chloride. 280Amyl mercaptans. 290Amyl phenol. 300Aniline. 310Aniline hydrochloride. 320Anisidine. 330Anisole. 340Anthranilic acid. 350Anthraquinone. 360Benzaldehyde. 370Benzamide. 380Benzene. 390Benzenedisulfonic acid. 400Benzene-sulfonic acid. 410Benzil. 420Benzilic acid. 430Benzoic acid. 440Benzoin. 450Bennzonitrile. 460Benzophenone. 480Benzotrichloride. 490Benzoyl chloride. 500Benzyl chalcohol. 510Benzyl amine. 520Benzyl benzoate. 530Benzyl chloride. 540Benzyl dichloride. 550Biphenyl. 560Bisphenol A. 570Bromobenzene. 580Bromonaphthalene. 590Butadiene. 5921-butene. 600n-butyl acetate. 630n-butyl acrylate. 640n-butyl alcohol. 650s-butyl alcohol. 660t-butyl alcohol. 670n-butylamine. 680s-butylamine. 690t-butylamine. 700p-pert-butyl benzoic acid. 750n-butyraldehyde. 760Butyric acid. 770Butyric anhydride. 780Butyronitrile. 785Caprolactam. 790Carbon disulfide. 800Carbon tetrabromide. 810Carbon tetrachloride. 820Cellulose acetate. 840Chloroacetic acid. 850m-chloroaniline. 860o-chloroaniline. 870p-chloroaniline. 880Chlorobenzaldehyde. 890Chlorobenzene. 900Chlorobenzoic acid. 905Chlorobenzotrichloride. 910Chlorobenzoyl chloride. 920Chlorodifluoroethane. 921Chlorodifluoromethane. 930Chloroform 940Chloronaphthalene. 950o-chloronitrobenzene. 951p-chloronitrobenzene. 960Chlorophenols. 964Chloroprene. 965Chlorosulfonic acid. 970m-chlorotoluene. 980o-chlorotoluene. 990p-chlorotoluene. 992Chlorotrifluoromethane. 1000m-cresol. 1010o-cresol. 1020p-cresol. 1021Mixed cresols. 1030Cresylic acid. 1040Crontonaldehyde. 1050Crontonic acid. 1060Cumene. 1070Cumene hydroperoxide. 1080Cyanoacetic acid. 1090Cyanogen chloride. 1100Cyanuric acid. 1110Cyanuric chloride. 1120Cychohexane. 1130Cyclohexanol. 1140Cyclohexanone. 1150Cyclohexene. 1160Cyclohexylamine. 1170Cyclooctadiene. 1180Decanol. 1190Diacetone alcohol. 1200Diaminobenzoic acid. 1210Dichloroaniline. 1215m-dichlorobenzene. 1216o-dichlorobenzene. 1220p-dichlorobenzene. 1221Dichlorodifluoromethane. 1240Dichloroethyl ether 1,2-dichloroethane. 1250Dichlorohydrin 1270Dichloropropene. 1280Dicyclohexylamine. 1290Diethylamine. 1300Diethylene glycol. 1304Diethylene glycol diethyl ether. 1305Diethylene glycol dimethyl ether. 1310Diethylene glycolmonobutyl ether. 1320Diethylene glycolmonobutyl ether acetate. 1330Diethylene glycolmonoethyl ether. 1340Diethylene glycolmonoethyl ether acetate. 1360Diethylene glycolmonomethyl ether. 1420Diethyl sulfate. 1430Difluoroethane. 1440Diisobutylene. 1442Diisodecyl phthalate. 1444Diisooctyl phthalate. 1450Diketene. 1460Dimethylamine. 1470N,N-dimethylaniline. 1480N,N-dimethylether. 1490N,N-dimethylformamide. 1495Dimethylhydrazine. 1500Dimethyl sulfate. 1510Dimethyl sulfide. 1520Dimethylsulfoxide. 1530Dimethylterephthalate. 15403,5-dinitrobenzoic acid. 1545Dinitrophenol. 1560Dioxane. 1570Dioxolane. 1580Diphenylamine. 1590Diphenyl oxide. 1600Diphenyl thiourea. 1610Dipropylene glycol. 1620Dodecene. 1630Dodecylaniline. 1640Dodecylphenol. 1650Epichlorohydrin. 1660Ethanol. 1661Ethanolamines. 1670Ethyl acetate. 1680Ethyl acetoacetate. 1690Ethyl acrylate. 1700Ethylamine. 1710Ethylbenzene. 1720Ethyl bromide. 1730Ethylcellulose. 1740Ethyl chloride. 1750Ethyl chloroacetate. 1760Ethylcyanoacetate. 1770Ethylene. 1780Ethylene carbonate. 1790Ethylene chlorodhydrin. 1800Ethylenediamine. 1810Ethylene dibromide. 1830Ethylene glycol. 1840Ethylene glycol diacetate. 1870Ethylene glycol dimethyl ether. 1890Ethylene glycol monobutyl ether. 1900Ethylene glycol monobutyl ether acetate. 1910Ethylene glycol monoethyl ether. 1920Ethylene glycol monoethyl ether acetate. 1930Ethylene glycol monoethyl ether. 1940Ethylene glycol monomethyl ether acetate. 1960Ethylene glycol monophenyl ether. 1970Ethylene glycol monopropyl ether. 1980Ethylene oxide. 1990Ethyl ether. 20002-ethylhexanol. 2010Ethyl orthoformate. 2020Ethyl oxalate. 2030Ethyl sodium oxalacetate. 2040Formaldehyde. 2050Formamide. 2060Formic acid. 2070Fumaric acid. 2073Furfural. 2090Glycerol (Synthetic). 2091Glycerol dichlorohydrin. 2100Glycerol triether. 2110Glycine. 2120Glyoxal. 2145Hexachlorobenzene. 2150Hexachloroethane. 2160Hexadecyl alcohol. 2165Hexamethylenediamine. 2170Hexamethylene glycol. 2180Hexamethylentetramine. 2190Hydrogen cyanide. 2200Hydroquinone. 2210p-hydroxy-benzoic acid. 2240Isoamylene. 2250Isobutanol. 2260Isobutyl acetate. 2261Isobutylene. 2270Isobutyraldehyde. 2280Isobutyric acid. 2300Isodecanol. 2320Isooctyl alcohol. 2321Isopentane. 2330Isophorone. 2340Isophthalic acid. 2350Isoprene. 2360Isopropanol. 2370Isopropyl acetate. 2380Isopropylamine. 2390Isopropyl chloride. 2400Isopropylphenol. 2410Ketene. 2414Linear alkylsulfonate. 2417Linear alkylbenzene. 2420Maleic acid. 2430Maleic anhydride. 2440Malic acid. 2450Mesityl oxide. 2455Metanilic acid. 2460Methacrylic acid. 2490Methallyl chloride. 2500Methanol. 2510Methyl acetate. 2520Methyl acetoacetate. 2530Methylamine. 2540n-methylaniline. 2545Methyl bromide. 2550Methyl butynol. 2560Methyl chloride. 2570Methyl cyclohexane. 2590Methyl cyclohexanone. 2620Methylene chloride. 2630Methylene dianiline. 2635Methylene diphenyl diisocyanate. 2640Methyl ethyl ketone. 2644Methyl formate. 2650Methyl isobutyl carbinol. 2660Methyl isobutyl ketone. 2665Methyl methacrylate. 2670Methyl pentynol. 2690a-methyl styrene. 2700Morpholine. 2710a-napthalene sulfonic acid. 2720B-napthalene sulfonic acid. 2730a-naphthol. 2740B-naphthol. 2750Neopentanoic acid. 2756o-nitroaniline. 2757p-nitroaniline. 2760o-nitroanisole. 2762p-nitroanisole. 2770Nitrobenzene. 2780Nitrobenzoic acid (o, m & p). 2790Nitroethane. 2791Nitromethane. 2792Nitrophenol. 2795Nitropropane. 2800Nitrotoluene. 2810Nonene. 2820Nonyl phenol. 2830Octyl phenol. 2840Paraldehyde. 2850Pentaerythritol. 2851n-pentane. 2855l-pentene. 2860Perchloroethylene. 2882Perchloromethylmercaptan. 2890o-phenetidine. 2900p-phenetidine. 2910Phenol. 2920Phenolsulfonic acids. 2930Phenyl anthranilic acid. 2940Phenylenediamine. 2960Phthalic anhydride. 2970Phthalimide. 2973b-picoline. 2976Piperazine. 3000Polybutenes. 3010Polyethylene glycol. 3025Polypropylene glycol. 3063Propionaldehyde. 3066Propionic acid. 3070n-propyl alcohol. 3075Propylamine. 3080Propyl chloride. 3090Propylene. 3100Propylene chlorohydrin. 3110Propylene dichloride. 3111Propylene glycol. 3120Propylene oxide. 3130Pyridine. 3140Quinone. 3150Resorcinol. 3160Resorcylic acid. 3170Salicylic acid. 3180Sodium acetate. 3181Sodium benzoate. 3190Sodium carboxymethylcellulose. 3191Sodium chloroacetate. 3200Sodium formate. 3210Sodium phenate. 3220Sorbic acid. 3230Styrene. 3240Succinic acid. 3250Succinitrile. 3251Sulfanilic acid. 3260Sulfolane. 3270Tannic acid. 3280Terephthalic acid. 3290 & 3291Tetrachloroethanes. 3300Tetrachlorophthalic anhydride. 3310Tetraethyllead. 3320Tetrahydronaphthalene. 3330Tetrahydrophthalic anhydride. 3335Tetramethyllead. 3340Tetramethylenediamine. 3341Tetramethylethylenediamine. 3349Toluene. 3350Toluene-2,4-diamine. 3354Toluene-2,4-diisocyanate. 3355Toluene diisocyanates (mixture). 3360Toluene sulfonamide. 3370Toluene sulfonic acids. 3380Toluene sulfonylchloride. 3381Toluidines. 3393Trichlorobenzenes. 33951,1,1-trichloroethane. 34001,1,2-trichloroethane. 3410Trichloroethylene. 3411Trichlorofluoromethane. 34201,2,3-trichloropropane. 34301,1,2-trichloro-1,2,2-trifluoroethane. 3450Triethylamine. 3460Triethylene glycol. 3470Triethylene glycoldimethyl ether. 3480Triisobutylene. 3490Trimethylamine. 3510Vinyl acetate. 3520Vinyl chloride. 3530Vinylidene chloride. 3540Vinyl toluene. 3541Xylene (mixed). 3560o-xylene. 3570p-xylene. 3580Xylenol. 3590Xylidine, 1,3-butylene glycol, Dinitrotoluene, Methyltertbutyl ether, Phosgene, Polyethylene, Polypropylene, Polystyrene, Urea.

1 The OCPDB Numbers are reference indices assigned to the various chemicals in the Organic Chemical Producers Data Base developed by the USEPA.

Appendix B to § 52.741—VOM Measurement Techniques for Capture Efficiency Procedure G.1—Captured VOC Emissions 1. Introduction

1.1 Applicability. This procedure is applicable for determining the volatile organic compounds (VOC) content of captured gas streams. It is intended to be used as a segment in the development of liquid/gas or gas/gas protocols for determining VOC capture efficiency (CE) for surface coating and printing operations. The procedure may not be acceptable in certain site-specific situations, e.g., when: (1) Direct fired heaters or other circumstances affect the quantity of VOC at the control device inlet; and (2) particulate organic aerosols are formed in the process and are present in the captured emissions.

1.2 Principle. The amount of VOC captured (G) is calculated as the sum of the products of the VOC content (CGj), the flow rate (QGj), and the sample time (TC) from each captured emissions point.

1.3 Estimated measurement uncertainty. The measurement uncertainties are estimated for each captured or fugitive emissions point as follows: QGj=±5.5 percent and CGj=±5.0 percent. Based on these numbers, the probable uncertainty for G is estimated at about ±7.4 percent.

1.4 Sampling requirements. A capture efficiency test shall consist of at least three sampling runs. The sampling time for each run should be at least 8 hours, unless otherwise approved.

1.5 Notes. Because this procedure is often applied in highly explosive areas, caution and care should be exercised in choosing appropriate equipment and installing and using the equipment. Mention of trade names or company products does not constitute endorsement. All gas concentrations (percent, ppm) are by volume, unless otherwise noted.

2. Apparatus and Reagents

2.1 Gas VOC concentration. A schematic of the measurement system is shown in Figure 1. The main components are described below:

2.1.1 Sample probe. Stainless steel, or equivalent. The probe shall be heated to prevent VOC condensation.

2.1.2 Calibration valve assembly. Three-way valve assembly at the outlet of sample probe to direct the zero and calibration gases to the analyzer. Other methods, such as quick-connect lines, to route calibration gases to the outlet of the sample probe are acceptable.

2.1.3 Sample line. Stainless steel or Teflon tubing to transport the sample gas to the analyzer. The sample line must be heated to prevent condensation.

2.1.4 Sample pump. A lead-free pump, to pull the sample gas through the system at a flow rate sufficient to minimize the response time of the measurement system. The components of the pump that contact the gas stream shall be constructed of stainless steel or Teflon. The sample pump must be heated to prevent condensation.

2.1.5 Sample flow rate control. A sample flow rate control valve and rotameter, or equivalent, to maintain a constant sampling rate within 10 percent. The flow rate control valve and rotameter must be heated to prevent condensation. A control valve may also be located on the sample pump bypass loop to assist in controlling the sample pressure and flow rate.

2.1.6 Sample gas manifold. Capable of diverting a portion of the sample gas stream to the flame ionization analyzer (FIA), and the remainder to the bypass discharge vent. The manifold components shall be constructed of stainless steel or Teflon. If captured or fugitive emissions are to be measured at multiple locations, the measurement system shall be designed to use separate sampling probes, lines, and pumps for each measurement location and a common sample gas manifold and FIA. The sample gas manifold and connecting lines to the FIA must be heated to prevent condensation.

2.1.7 Organic concentration analyzer. An FIA with a span value of 1.5 times the expected concentration as propane; however, other span values may be used if it can be demonstrated that they would provide more accurate measurements.

The system shall be capable of meeting or exceeding the following specifications:

2.1.7.1 Zero drift. Less than ±3.0 percent of the span value.

2.1.7.2 Calibration drift. Less than ±3.0 percent of the span value.

2.1.7.3 Calibration error. Less than ±5.0 percent of the calibration gas value.

2.1.7.4 Response time. Less than 30 seconds.

2.1.8 Integrator/data acquisition system. An analog or digital device or computerized data acquisition system used to integrate the FIA response or compute the average response and record measurement data. The minimum data sampling frequency for computing average or integrated values is one measurement value every 5 seconds. The device shall be capable of recording average values at least once per minute.

2.1.9 Calibration and other gases. Gases used for calibration, fuel, and combustion air (if required) are contained in compressed gas cylinders. All calibration gases shall be traceable to NIST standards and shall be certified by the manufacturer to ±1 percent of the tag value. Additionally, the manufacturer of the cylinder should provide a recommended shelf life for each calibration gas cylinder over which the concentration does not change more than ±2 percent from the certified value. For calibration gas values not generally available, alternative methods for preparing calibration gas mixtures, such as dilution systems, may be used with prior approval.

2.1.9.1 Fuel. A 40 percent H2/60 percent He or 40 percent H2/60 percent N2 gas mixture is recommended to avoid an oxygen synergism effect that reportedly occurs when oxygen concentration varies significantly from a mean value.

2.1.9.2 Carrier gas. High purity air with less than 1 ppm of organic material (as propane or carbon equivalent) or less than 0.1 percent of the span value, whichever is greater.

2.1.9.3 FIA Linearity calibration gases. Low-, mid-, and high-range gas mixture standards with nominal propane concentrations of 20-30, 45-55, and 70-80 percent of the span value in air, respectively. Other calibration values and other span values may be used if it can be shown that more accurate measurements would be achieved.

2.1.10 Particulate filter. An in-stack or an out-of-stack glass fiber filter is recommended if exhaust gas particulate loading is significant. An out-of-stack filter must be heated to prevent any condensation unless it can be demonstrated that no condensation occurs.

2.2 Captured emissions volumetric flow rate.

2.2.1 Method 2 or 2A apparatus. For determining volumetric flow rate.

2.2.2 Method 3 apparatus and reagents. For determining molecular weight of the gas stream. An estimate of the molecular weight of the gas stream may be used if it can be justified.

2.2.3 Method 4 apparatus and reagents. For determining moisture content, if necessary.

3. Determinations of Volumetric Flow Rate of Captured Emissions

3.1 Locate all points where emissions are captured from the affected facility. Using Method 1, determine the sampling points. Be sure to check each site for cyclonic or swirling flow.

3.2 Measure the velocity at each sampling site at least once every hour during each sampling run using Method 2 or 2A.

4. Determinations of VOC Content of Captured Emissions

4.1 Analysis duration. Measure the VOC responses at each captured emissions point during the entire test run or, if applicable, while the process is operating. If there are multiple captured emission locations, design a sampling system to allow a single FIA to be used to determine the VOC responses at all sampling locations.

4.2 Gas VOC concentration.

4.2.1 Assemble the sample train as shown in Figure 1. Calibrate the FIA according to the procedure in section 5.1.

4.2.2 Conduct a system check according to the procedure in section 5.3.

4.2.3 Install the sample probe so that the probe is centrally located in the stack, pipe, or duct, and is sealed tightly at the stack port connection.

4.2.4 Inject zero gas at the calibration valve assembly. Allow the measurement system response to reach zero. Measure the system response time as the time required for the system to reach the effluent concentration after the calibration valve has been returned to the effluent sampling position.

4.2.5 Conduct a system check before and a system check after each sampling run according to the procedures in sections 5.2 and 5.3. If the drift check following a run indicates unacceptable performance, the run is not valid. The tester may elect to perform system drift checks during the run not to exceed one drift check per hour.

4.2.6 Verify that the sample lines, filter, and pump temperatures are 120 ±5 °C.

4.2.7 Begin sampling at the start of the test period and continue to sample during the entire run. Record the starting and ending times and any required process information as appropriate. If multiple captured emission locations are sampled using a single FIA, sample at each location for the same amount of time (e.g., 2 minutes) and continue to switch from one location to another for the entire test run. Be sure that total sampling time at each location is the same at the end of the test run. Collect at least 4 separate measurements from each sample point during each hour of testing. Disregard the measurements at each sampling location until two times the response time of the measurement system has elapsed. Continue sampling for at least 1 minute and record the concentration measurements.

4.3 Background concentration.

4.3.1 Locate all NDO's of the TTE. A sampling point shall be centrally located outside of the TTE at 4 equivalent diameters from each NDO, if possible. If there are more than 6 NDO's, choose 6 sampling points evenly spaced among the NDO's.

4.3.2 Assemble the sample train as shown in Figure 2. Calibrate the FIA and conduct a system check according to the procedures in sections 5.1 and 5.3.

Note:

This sample train shall be a separate sampling train from the one to measure the captured emissions.

4.3.3 Position the probe at the sampling location.

4.3.4 Determine the response time, conduct the system check and sample according to the procedures described in sections 4.2.4 to 4.2.7.

4.4 Alternative procedure. The direct interface sampling and analysis procedure described in section 7.2 of Method 18 may be used to determine the gas VOC concentration. The system must be designed to collect and analyze at least one sample every 10 minutes.

5. Calibration and Quality Assurance

5.1 FIA calibration and linearity check. Make necessary adjustments to the air and fuel supplies for the FIA and ignite the burner. Allow the FIA to warm up for the period recommended by the manufacturer. Inject a calibration gas into the measurement system and adjust the back-pressure regulator to the value required to achieve the flow rates specified by the manufacturer. Inject the zero- and the high-range calibration gases and adjust the analyzer calibration to provide the proper responses. Inject the low- and mid-range gases and record the responses of the measurement system. The calibration and linearity of the system are acceptable if the responses for all four gases are within 5 percent of the respective gas values. If the performance of the system is not acceptable, repair or adjust the system and repeat the linearity check. Conduct a calibration and linearity check after assembling the analysis system and after a major change is made to the system.

5.2 Systems drift checks. Select the calibration gas that most closely approximates the concentration of the captured emissions for conducting the drift checks. Introduce the zero and calibration gas at the calibration valve assembly and verify that the appropriate gas flow rate and pressure are present at the FIA. Record the measurement system responses to the zero and calibration gases. The performance of the system is acceptable if the difference between the drift check measurement and the value obtained in section 5.1 is less than 3 percent of the span value. Conduct the system drift checks at the end of each run.

5.3 System check. Inject the high range calibration gas at the inlet to the sampling probe while the dilution air is turned off. Record the response. The performance of the system is acceptable if the measurement system response is within 5 percent of the value obtained in section 5.1 for the high range calibration gas. Conduct a system check before and after each test run.

5.4 Analysis audit. Immediately before each test analyze an audit cylinder as described in section 5.2. The analysis audit must agree with the audit cylinder concentration within 10 percent.

6. Nomenclature Ai = area of NDO i, ft 2. AN = total area of all NDO's in the enclosure, ft 2. CBi = corrected average VOC concentration of background emissions at point i, ppm propane. CB = average background concentration, ppm propane. CGj = corrected average VOC concentration of captured emissions at point j, ppm propane. CDH = average measured concentration for the drift check calibration gas, ppm propane. CDO = average system drift check concentration for zero concentration gas, ppm propane. CH = actual concentration of the drift check calibration gas, ppm propane. Ci = uncorrected average background VOC concentration measured at point i, ppm propane. Cj = uncorrected average VOC concentration measured at point j, ppm propane. G = total VOC content of captured emissions, kg. K1 = 1.830 × 10−6 kg/ (m 3-ppm). n = number of measurement points. QGj = average effluent volumetric flow rate corrected to standard conditions at captured emissions point j, m 3/min. TC = total duration of captured emissions sampling run, min. 7. Calculations

7.1 Total VOC captured emissions.

7.2 VOC concentration of the captured emissions at point j.

7.3. Background VOC concentration at point i.

7.4 Average background concentration.

Note:

If the concentration at each point is with in 20 percent of the average concentration of all points, the terms “Ai” and “AN” may be deleted from Equation 4.

Procedure G.2—Captured VOC Emissions (Dilution Technique) 1. Introduction

1.1 Applicability. This procedure is applicable for determining the volatile organic compounds (VOC) content of captured gas streams. It is intended to be used as a segment in the development of a gas/gas protocol in which fugitive emissions are measured for determining VOC capture efficiency (CE) for surface coating and printing operations. A dilution system is used to reduce the VOC concentration of the captured emission to about the same concentration as the fugitive emission. The procedure may not be acceptable in certain site-specific situations, e.g., when: (1) Direct fired heaters or other circumstances affect the quantity of VOC at the control device inlet; and (2) particulate organic aerosols are formed in the process and are present in the captured emissions.

1.2 Principle. The amount of VOC captured (G) is calculated as the sum of the products of the VOC content (CGj), the flow rate (QGj), and the sampling time (TC) from each captured emissions point.

1.3 Estimated measurement uncertainty. The measurement uncertainties are estimated for each captured or fugitive emissions point as follows: OGj=±5.5 percent and CGj=±5 percent. Based on these numbers, the probable uncertainty for G is estimated at about ±7.4 percent.

1.4 Sampling requirements. A capture efficiency test shall consist of at least three sampling runs. The sampling time for each run should be at least 8 hours, unless otherwise approved.

1.5 Notes. Because this procedure is often applied in highly explosive areas, caution and care should be exercised in choosing appropriate equipment and installing and using the equipment. Mention of trade names or company products does not constitute endorsement. All gas concentrations (percent, ppm) are by volume, unless otherwise noted.

2. Apparatus and Reagents

2.1 Gas VOC concentration. A schematic of the measurement system is shown in Figure 1. The main components are described below:

2.1.1 Dilution system. A Kipp in-stack dilution probe and controller or similar device may be used. The dilution rate may be changed by substituting different critical orifices or adjustments of the aspirator supply pressure. The dilution system shall be heated to prevent VOC condensation.

Note:

An out-of-stack dilution device may be used.

2.1.2 Calibration valve assembly. Three-way valve assembly at the outlet of sample probe to direct the zero and calibration gases to the analyzer. Other methods, such as quick-connect lines, to route calibration gases to the outlet of the sample probe are acceptable.

2.1.3 Sample line. Stainless steel or Teflon tubing to transport the sample gas to the analyzer. The sample line must be heated to prevent condensation.

2.1.4 Sample pump. A leak-free pump, to pull the sample gas through the system at a flow rate sufficient to minimize the response time of the measurement system. The components of the pump that contract the gas stream shall be constructed of stainless steel or Teflon. The sample pump must be heated to prevent condensation.

2.1.5 Sample flow rate control. A sample flow rate control valve and rotameter, or equivalent, to maintain a constant sampling rate within 10 percent. The flow control valve and rotameter must be heated to prevent condensation. A control valve may also be located on the sample pump bypass loop to assist in controlling the sample pressure and flow rate.

2.1.6 Sample gas manifold. Capable of diverting a portion of the sample gas stream to the flame ionization analyzer (FIA), and the remainder to the bypass discharge vent. The manifold components shall be constructed of stainless steel or Teflon. If captured or fugitive emissions are to be measured at multiple locations, the measurement system shall be designed to use separate sampling probes, lines, and pumps for each measurement location and a common sample gas manifold and FIA. The sample gas manifold and connecting lines to the FIA must be heated to prevent condensation.

2.1.7 Organic concentration analyzer. An FIA with a span value of 1.5 times the expected concentration as propane; however, other span values may be used if it can be demonstrated that they would provide more accurate measurements.

The system shall be capable of meeting or exceeding the following specifications:

2.1.7.1 Zero drift. Less than ±3.0 percent of the span value.

2.1.7.2 Calibration drift. Less than ±3.0 percent of the span value.

2.1.7.3 Calibration error. Less than ±5.0 percent of the calibration gas value.

2.1.7.4 Response time. Less than 30 seconds.

2.1.7.8 Integrator/data acquisition system. An analog or digital device or computerized data acquisition system used to integrate the FIA response or compute the average response and record measurement data. The minimum data sampling frequency for computing average or integrated values is one measurement value every 5 seconds. The device shall be capable of recording average values at least once per minute.

2.1.9 Calibration and other gases. Gases used for calibration, fuel, and combustion air (if required) are contained in compressed gas cylinders. All calibration gases shall be traceable to NIST standards and shall be certified by the manufacturer to ±1 percent of the tag value. Additionally, the manufacturer of the cylinder should provide a recommended shelf life for each calibration gas cylinder over which the concentration does not change more than ±2 percent from the certified value. For calibration gas values not generally available, alternative methods for preparing calibration gas mixtures, such as dilution system, may be used with prior approval.

2.1.9.1 Fuel. A 40 percent H2/60 percent He or 40 percent H2/60 percent N2 gas mixture is recommended to avoid an oxygen synergism effect that reportedly occurs when oxygen concentration varies significantly from a mean value.

2.1.9.2. Carrier gas and dilution air supply. High purity air with less than 1 ppm of organic material (as propane or carbon equivalent) or less than 0.1 percent of the span value, whichever is greater.

2.1.9.3 FIA linearity calibration gases. Low-, mid-, and high-range gas mixture standards with nominal propane concentrations of 20-30, 45-55, and 70-80 percent of the span value in air, respectively. Other calibration values and other span values may be used if it can be shown that more accurate measurements would be achieved.

2.1.9.4 Dilution check gas. Gas mixture standard containing propane in air, approximately half the span value after dilution.

2.1.10 Particulate filter. An in-stack or an out-of-stack glass fiber filter is recommended if exhaust gas particulate loading is significant. An out-of-stack filter must be heated to prevent any condensation unless it can be demonstrated that no condensation occurs.

2.2 Captured emissions volumetric flow rate.

2.2.1 Method 2 or 2A apparatus. For determining volumetric flow rate.

2.2.2 Method 3 apparatus and reagents. For determining molecular weight of the gas stream. An estimate of the molecular weight of the gas stream may be used if it can be justified.

2.2.3 Method 4 apparatus and reagents. For determining moisture content, if necessary.

3. Determination of Volumetric Flow Rate of Captured Emissions

3.1 Locate all points where emissions are captured from the affected facility. Using Method 1, determine the sampling points. Be sure to check each site for cyclonic or swirling flow.

3.2 Measure the velocity at each sampling site at least once every hour during each sampling run using Method 2 or 2A.

4. Determination of VOC Content of Captured Emissions

4.1 Analysis duration. Measure the VOC responses at each captured emissions point during the entire test run or, if applicable, while the process is operating. If there are multiple captured emissions locations, design a sampling system to allow a single FIA to be used to determine the VOC responses at all sampling locations.

4.2 Gas VOC concentration.

4.2.1 Assemble the sample train as shown in Figure 1. Calibrate the FIA according to the procedure in section 5.1.

4.2.2 Set the dilution ratio and determine the dilution factor according to the procedure in section 5.3.

4.2.3 Conduct a system check according to the procedure in section 5.4.

4.2.4 Install the sample probe so that the probe is centrally located in the stack, pipe, or duct, and is sealed tightly at the stack port connection.

4.2.5 Inject zero gas at the calibration valve assembly. Measure the system response time as the time required for the system to reach the effluent concentration after the calibration valve has been returned to the effluent sampling position.

4.2.6 Conduct a system check before and a system drift check after each sampling run according to the procedures in sections 5.2 and 5.4. If the drift check following a run indicates unacceptable performance, the run is not valid. The tester may elect to perform system drift checks during the run not to exceed one drift check per hour.

4.2.7 Verify that the sample lines, filter, and pump temperatures are 120 ±5 °C.

4.2.8 Begin sampling at the start of the test period and continue to sample during the entire run. Record the starting and ending times and any required process information as appropriate. If multiple captured emission locations are sampled using a single FIA, sample at each location for the same amount of time (e.g., 2 minutes) and continue to switch from one location to another for the entire test run. Be sure that total sampling time at each location is the same at the end of the test run. Collect at least 4 separate measurements from each sample point during each hour of testing. Disregard the measurements at each sampling location until two times the response time of the measurement system has elapsed. Continue sampling for at least 1 minute and record the concentration measurements.

4.3 Background concentration.

4.3.1 Locate all NDO's of the TTE. A sampling point shall be centrally located outside of the TTE at 4 equivalent diameters from each NDO, if possible. If there are more than 6 NDO's, choose 6 sampling points evenly spaced among the NDO's.

4.3.2 Assemble the sample train as shown in Figure 2. Calibrate the FIA and conduct a system check according to the procedures in sections 5.1 and 5.4.

4.3.3 Position the probe at the sampling location.

4.3.4 Determine the response time, conduct the system check and sample according to the procedures described in sections 4.2.4 to 4.2.8.

4.4 Alternative procedure. The direct interface sampling and analysis procedure described in section 7.2 of Method 18 may be used to determine the gas VOC concentration. The system must be designed to collect and analyze at least one sample every 10 minutes.

5. Calibration and Quality Assurance

5.1 FIA Calibration and linearity check. Make necessary adjustments to the air and fuel supplies for the FIA and ignite the burner. Allow the FIA to warm up for the period recommended by the manufacturer. Inject a calibration gas into the measurement system after the dilution system and adjust the back-pressure regulator to the value required to achieve the flow rates specified by the manufacturer. Inject the zero- and the high-range calibration gases and adjust the analyzer calibration to provide the proper responses. Inject the low- and mid-range gases and record the responses of the measurement system. The calibration and linearity of the system are acceptable if the responses for all four gases are within 5 percent of the respective gas values. If the performance of the system is not acceptable, repair or adjust the system and repeat the linearity check. Conduct a calibration and linearity check after assembling the analysis system and after a major change is made to the system.

5.2 Systems drift checks. Select the calibration gas that most closely approximates the concentration of the diluted captured emissions for conducting the drift checks. Introduce the zero and calibration gas at the calibration valve assembly and verify that the appropriate gas flow rate and pressure are present at the FIA. Record the measurement system responses to the zero and calibration gases. The performance of the system is acceptable if the difference between the drift check measurement and the value obtained in section 5.1 is less than 3 percent of the span value. Conduct the system drift check at the end of each run.

5.3 Determination of dilution factor. Inject the dilution check gas into the measurement system before the dilution system and record the response. Calculate the dilution factor using Equation 3.

5.4 System check. Inject the high range calibration gas at the inlet to the sampling probe while the dilution air is turned off. Record the response. The performance of the system is acceptable if the measurement system response is within 5 percent of the value obtained in section 5.1 for the high range calibration gas. Conduct a system check before and after each test run.

5.5 Analysis audit. Immediately before each test analyze an audit cylinder as described in section 5.2. The analysis audit must agree with the audit cylinder concentration within 10 percent.

6. Nomenclature Ai = area of NDO i, ft 2. AN = total area of all NDO's in the enclosure, ft 2. CA = actual concentration of the dilution check gas, ppm propane. CBi = corrected average VOC concentration of background emissions at point i, ppm propane. CB = average background concentration, ppm propane. CDH = average measured concentration for the drift check calibration gas, ppm propane. CDO = average system drift check concentration for zero concentration gas, ppm propane. CH = actual concentration of the drift check calibration, gas, ppm propane. Ci = uncorrected average background VOC concentration measured at point i, ppm propane. Cj = uncorrected average VOC concentration measured at point j, ppm propane. CM = measured concentration of the dilution check gas, ppm propane. DF = dilution factor. G = total VOC content of captured emissions, kg. K1 = 1.830 × 10−6 kg/(m 3-ppm). n = number of measurement points. QGj = average effluent volumetric flow rate corrected to standard conditions at captured emissions point j, m 3/min. TC = total duration of capture efficiency sampling run, min. 7. Calculations

7.1 Total VOC captured emissions.

7.2 VOC concentration of the captured emissions to point j.

7.3 Dilution factor.

7.4 Background VOC concentration at point i.

7.5 Average background concentration.

Note:

If the concentration at each point is within 20 percent of the average concentration of all points, the terms “Ai” and “AN” may be deleted from Equation 4.

Procedure F.2—Fugitive VOC Emissions from Building Enclosures 1. Introduction

1.1 Applicability. This procedure is applicable for determining the fugitive volatile organic compounds (VOC) emissions from a building enclosure (BE). It is intended to be used as a segment in the development of liquid/gas or gas/gas protocols for determining VOC capture efficiency (CE) for surface coating and printing operations.

1.2 Principle. The total amount of fugitive VOC emissions (FB) from the BE is calculated as the sum of the products of the VOC content (CFj) of each fugitive emissions point, its flow rate (QFj), and time (TF).

1.3 Measurement uncertainty. The measurement uncertainties are estimated for each fugitive emissions point as follows: QFj=±5.0 percent and CFj=±5.0 percent. Based on these numbers, the probable uncertainty for FB is estimated at about ±11.2 percent.

1.4 Sampling requirements. A capture efficiency test shall consist of at least three sampling runs. The sampling time for each run should be at least 8 hours, unless otherwise approved.

1.5 Notes. Because this procedure is often applied in highly explosive areas, caution and care should be exercised in choosing appropriate equipment and installing and using the equipment. Mention of trade names or company products does not constitute endorsement. All gas concentrations (percent, ppm) are by volume, unless otherwise noted.

2. Apparatus and Reagents

2.1 Gas VOC concentration. A schematic of the measurement system is shown in Figure 1. The main components are described below:

2.1.1 Sample probe. Stainless steel, or equivalent. The probe shall be heated to prevent VOC condensation.

2.1.2 Calibration valve assembly. Three-way valve assembly at the outlet of sample probe to direct the zero and calibration gases to the analyzer. Other methods, such as quick-connect lines, to route calibration gases to the outlet of the sample probe are acceptable.

2.1.3 Sample line. Stainless steel or Teflon tubing to transport the sample gas to the analyzer. The sample line must be heated to prevent condensation.

2.1.4 Sample pump. A leak-free pump, to pull the sample gas through the system at a flow rate sufficient to minimize the response time of the measurement system. The components of the pump that contact the gas stream shall be constructed of staimust be heated to prevent condensation.

2.1.5 Sample flow rate control. A sample flow rate control valve and rotameter, or equivalent, to maintain a constant sampling rate within 10 percent. The flow rate control valve and rotameter must be heated to prevent condensation. A control valve may also be located on the sample pump bypass loop to assist in controlling the sample pressure and flow rate.

2.1.6 Sample gas manifold. Capable of diverting a portion of the sample gas stream to the flame ionization analyzer (FIA), and the remainder to the bypass discharge vent. The manifold components shall be constructed of stainless steel or Teflon. If emissions are to be measured at multiple locations, the measurement system shall be designed to use separate sampling probes, lines, and pumps for each measurement location and a common sample gas manifold and FIA. The sample gas manifold must be heated to prevent condensation.

2.1.7 Organic Concentration Analyzer. An FIA with a span value of 1.5 times the expected concentration as propane; however, other span values may be used if it can be demonstrated that they would provide more accurate measurements. The system shall be capable or exceeding the following specifications:

2.1.7.1 Zero drift. Less than ±3.0 percent of the span value.

2.1.7.2 Calibration drift. Less than ±3.0 percent of the span value.

2.1.7.3 Calibration error. Less than ±5.0 percent of the calibration gas value.

2.1.7.4 Response time. Less than 30 seconds.

2.1.8 Integrator/data acquisition system. An analog or digital device or computerized data acquisition system used to integrate the FIA response or compute the average response and record measurement data. The minimum data sampling frequency for computing average or integrated values is one measurement value every 5 seconds. The device shall be capable of recording average values at least once per minute.

2.1.9 Calibration and other gases. Gases used for calibration, fuel, and combustion air (if required) are contained in compressed gas cylinders. All calibration gases shall be traceable to NIST standards and shall be certified by the manufacturer to ±1 percent of the tag value. Additionally, the manufacturer of the cylinder should provide a recommended shelf life for each calibration gas cylinder over which the concentration does not change more than ±2 percent from the certified value. For calibration gas values not generally available, alternative methods for preparing calibration gas mixtures, such as dilution systems, may be used with prior approval.

2.1.9.1 Fuel. A 40 percent H2/60 percent He or 40 percent H2/60 percent N2 gas mixture is recommended to avoid an oxygen synergism effect that reportedly occurs when oxygen concentration varies significantly from a mean value.

2.1.9.2 Carrier gas. High purity air with less than 1 ppm of organic material (propane or carbon equivalent) or less than 0.1 percent of the span value, whichever is greater.

2.1.9.3 FIA linearity calibration gases. Low-, mid-, and high-range gas mixture standards with nominal propane concentrations of 20-30, 45-55, and 70-80 percent of the span value in air, respectively. Other calibration values and other span values may be used if it can be shown that more accurate measurements would be achieved.

2.1.10 Particulate filter. An in-stack or an out-of-stack glass fiber filter is recommended if exhaust gas particulate loading is significant. An out-of-stack filter must be heated to prevent any condensation unless it can be demonstrated that no condensation occurs.

2.2 Fugitive emissions volumetric flow rate.

2.2.1 Flow direction indicators. Any means of indicating inward or outward flow, such as light plastic film or paper streamers, smoke tubes, filaments, and sensory perception.

2.2.2 Method 2 or 2A apparatus. For determining volumetric flow rate. Anemometers or similar devices calibrated according to the manufacturer's instructions may be used when low velocities are present. Vane anemometers (Young-maximum response propeller), specialized pitots with electronic manometers (e.g., Shortridge Instruments Inc., Airdata Multimeter 860) are commercially available with measurement thresholds of 15 and 8 mpm (50 and 25 fpm), respectively.

2.2.3 Method 3 apparatus and reagents. For determining molecular weight of the gas stream. An estimate of the molecular weight of the gas stream may be used if it can be justified.

2.2.4 Method 4 apparatus and reagents. For determining moisture content, if necessary.

3. Determination of Volumetric Flow Rate of Fugitive Emissions

3.1 Preliminary determinations. The purpose of this exercise is to determine which exhaust points should be measured for volumetric flow rates and VOC concentrations.

3.1.1 Forced draft openings. Identify all forced draft openings. Determine the volumetric flow rate according to Method 2.

3.1.2 NDO's exhaust points. The NDO's in the roof of a facility are considered to be exhaust points. Determine volumetric flow rate from these NDO's. Divide the cross-sectional area according to Method 1 using 12 equal areas. Use the appropriate velocity measurement devices, e.g., propeller anemometers.

3.1.3 Other NDO's.

3.1.3.1 This step is optional. Determine the exhaust flow rate, including that of the control device, from the enclosure and the intake air flow rate. If the exhaust flow rate divided by the intake air flow rate is greater than 1.1, then all other NDO's are not considered to be significant exhaust points.

3.1.3.2 If the option above is not taken, identify all other NDO's and other potential points through which fugitive emissions may escape the enclosure. Then use the following criteria to determine whether flow rates and VOC concentrations need to be measured:

3.1.3.2.1 Using the appropriate flow direction indicator, determine the flow direction. An NDO with zero or inward flow is not an exhaust point.

3.1.3.2.2 Measure the outward volumetric flow rate from the remainder of the NDO's. If the collective flow rate is 2 percent, or less, of the flow rate from sections 3.1.1 and 3.1.2, then these NDO's, except those within two equivalent diameters (based on NDO opening) from VOC sources, may be considered to be non-exhaust points.

3.1.3.2.3 If the percentage calculated in section 3.1.3.2.2 is greater than 2 percent, those NDO's (except those within two equivalent diameters from VOC sources) whose volumetric flow rate totals 2 percent of the flow rate from sections 3.1.1 and 3.1.2 may be considered as non-exhaust points. All remaining NDO's shall be measured for volumetric flow rate and VOC concentrations during the CE test.

3.1.3.2.4 The tester may choose to measure VOC concentrations at the forced exhaust points and the NDO's. If the total VOC emissions from the NDO's are less than 2 percent of the emissions from the forced draft and roof NDO's, then these NDO's may be eliminated from further consideration.

3.2 Determination of flow rates.

3.2.1 Measure the volumetric flow rate at all locations identified as exhaust points in section 3.1. Divide each exhaust opening into 9 equal areas for rectangular openings and 8 for circular openings.

3.2.2 Measure the velocity at each site at least once every hour during each sampling run using Method 2 or 2A, if applicable, or using the low velocity instruments in section 2.2.2.

4. Determination of VOC Content of Fugitive Emissions

4.1 Analysis duration. Measure the VOC responses at each fugitive emission point during the entire test run or, if applicable, while the process is operating. If there are multiple emissions locations, design a sampling system to allow a single FIA to be used to determine the VOC responses at all sampling locations.

4.2 Gas VOC concentration.

4.2.1 Assemble the sample train as shown in Figure 1. Calibrate the FIA and conduct a system check according to the procedures in sections 5.1 and 5.3, respectively.

4.2.2 Install the sample probe so that the probe is centrally located in the stack, pipe, or duct, and is sealed tightly at the stack port connection.

4.2.3 Inject zero gas at the calibration valve assembly. Allow the measurement system response to reach zero. Measure the system response time as the time required for the system to reach the effluent concentration after the calibration valve has been returned to the effluent sampling position.

4.2.4 Conduct a system check before and a system drift check after each sampling run according to the procedures in sections 5.2 and 5.3. If the drift check following a run indicates unacceptable performance, the run is not valid. The tester may elect to perform drift checks during the run not to exceed one drift check per hour.

4.2.5 Verify that the sample lines, filter, and pump temperatures are 120 ±5 °C.

4.2.6 Begin sampling at the start of the test period and continue to sample during the entire run. Record the starting and ending times and any required process information as appropriate. If multiple emission locations are sampled using a single FIA, sample at each location for the same amount of time (e.g., 2 minutes) and continue to switch from one location to another for the entire test run. Be sure that total sampling time at each location is the same at the end of the test run. Collect at least 4 separate measurements from each sample point during each hour of testing. Disregard the response measurements at each sampling location until two times the response time of the measurement system has elapsed. Continue sampling for at least 1 minute and record the concentration measurements.

4.3 Alternative procedure. The direct interface sampling and analysis procedure described in section 7.2 of Method 18 may be used to determine the gas VOC concentration. The system must be designed to collect and analyze at least one sample every 10 minutes.

5. Calibration and Quality Assurance

5.1 FIA calibration and linearity check. Make necessary adjustments to the air and fuel supplies for the FIA and ignite the burner. Allow the FIA to warm up for the period recommended by the manufacturer. Inject a calibration gas into the measurement system and adjust the back-pressure regulator to the value required to achieve the flow rates specified by the manufacturer. Inject the zero- and the high-range calibration gases and adjust the analyzer calibration to provide the proper responses. Inject the low- and mid-range gases and record the responses of the measurement system. The calibration and linearity of the system are acceptable if the responses for all four gases are within 5 percent of the respective gas values. If the performance of the system is not acceptable, repair or adjust the system and repeat the linearity check. Conduct a calibration and linearity check after assembling the analysis system and after a major change is made to the system.

5.2 Systems drift checks. Select the calibration gas that most closely approximates the concentration of the captured emissions for conducting the drift checks. Introduce the zero and calibration gas at the calibration valve assembly and verify that the appropriate gas flow rate and pressure are present at the FIA. Record the measurement system responses to the zero and calibration gases. The performance of the system is acceptable if the difference between the drift check measurement and the value obtained in section 5.1 is less than 3 percent of the span value. Conduct a system drift check at the end of each run.

5.3 System check. Inject the high range calibration gas at the inlet of the sampling probe and record the response. The performance of the system is acceptable if the measurement system response is within 5 percent of the value obtained in section 5.1 for the high range calibration gas. Conduct a system check before each test run.

5.4 Analysis audit. Immediately before each test analyze an audit cylinder as described in section 5.2. The analysis audit must agree with the audit cylinder concentration within 10 percent.

6. Nomenclature CDH = average measured concentration for the drift check calibration gas, ppm propane. CDO = average system drift check concentration for zero concentration gas, ppm propane. CFj = corrected average VOC concentration of fugitive emissions at point j, ppm propane. CH = actual concentration of the drift check calibration gas, ppm propane. Cj = uncorrected average VOC concentration measured at point j, ppm propane. FB = total VOC content of fugitive emissions from the building, kg. K1 = 1.830 × 10−6 kg/(m 3-ppm). n = number of measurement points. QFj = average effluent volumetric flow rate corrected to standard conditions at fugitive emissions point j, m 3/min. TF = total duration of capture efficiency sampling run, min. 7. Calculations

7.1 Total VOC fugitive emissions from the building.

7.2 VOC concentration of the fugitive emissions at point j.

Procedure F.1—Fugitive VOC Emissions From Temporary Enclosures 1. Introduction

1.1 Applicability. This procedure is applicable for determining the fugitive volatile organic compounds (VOC) emissions from a temporary total enclosure (TTE). It is intended to be used as a segment in the development of liquid/gas or gas/gas protocols for determining VOC capture efficiency (CE) for surface coating and printing operations.

1.2 Principle. The amount of fugitive VOC emissions (F) from the TTE is calculated as the sum of the products of the VOC content (CFj), the flow rate (QFj), and the sampling time (TF) from each fugitive emissions point.

1.3 Estimated measurement uncertainty. The measurement uncertainties are estimated for each fugitive emission point as follows: Q=±5.5 percent and CFj=±5.0 percent. Based on these numbers, the probable uncertainty for F is estimated at about ±7.4 percent.

1.4 Sampling requirements. A capture efficiency test shall consist of at least three sampling runs. The sampling time for each run should be at least 8 hours, unless otherwise approved.

1.5 Notes. Because this procedure is often applied in highly explosive areas, caution and care should be exercised in choosing appropriate equipment and installing and using the equipment. Mention of trade names or company products does not constitute endorsement. All gas concentrations (percent, ppm) are by volume, unless otherwise noted.

2. Apparatus and Reagents

2.1 Gas VOC concentration. A schematic of the measurement system is shown in Figure 1. The main components are described below:

2.1.1 Sample probe. Stainless steel, or equivalent. The probe shall be heated to prevent VOC condensation.

2.1.2 Calibration valve assembly. Three-way valve assembly at the outlet of sample probe to direct the zero and calibration gases to the analyzer. Other methods, such as quick-connect lines, to route calibration gases to the outlet of the sample probe are acceptable.

2.1.3 Sample line. Stainless steel or Teflon tubing to transport the sample gas to the analyzer. The sample line must be heated to prevent condensation.

2.1.4 Sample pump. A leak-free pump, to pull the sample gas through the system at a flow rate sufficient to minimize the response time of the measurement system. The components of the pump that contact the gas stream shall be constructed of stainless steel or Teflon. The sample pump must be heated to prevent condensation.

2.1.5 Sample flow rate control. A sample flow rate control valve and rotameter, or equivalent, to maintain a constant sampling rate within 10 percent. The flow control valve and rotameter must be heated to prevent condensation. A control valve may also be located on the sample pump bypass loop to assist in controlling the sample pressure and flow rate.

2.1.6 Sample gas manifold. Capable of diverting a portion of the sample gas stream to the flame ionization analyzer (FIA), and the remainder to the bypass discharge vent. The manifold components shall be constructed of stainless steel or Teflon. If emissions are to be measured at multiple locations, the measurement system shall be designed to use separate sampling probes, lines, and pumps for each measurement location and a common sample gas manifold and FIA. The sample gas manifold and connecting lines to the FIA must be heated to prevent condensation.

2.1.7 Organic concentration analyzer. An FIA with a span value of 1.5 times the expected concentration as propane; however, other span values may be used if it can be demonstrated that they would provide more accurate measurements. The system shall be capable of meeting or exceeding the following specifications:

2.1.7.1 Zero drift. Less than ±3.0 percent of the span value.

2.1.7.2 Calibration drift. Less than ±3.0 percent of the span value.

2.1.7.3 Calibration error. Less than ±5.0 percent of the calibration gas value.

2.1.7.4 Response time. Less than 30 seconds.

2.1.8 Integrator/data acquisition system. An analog or digital device or computerized data acquisition system used to integrate the FIA response or compute the average response and record measurement data. The minimum data sampling frequency for computing average or integrated values is one measurement value every 5 seconds. The device shall be capable of recording average values at least once per minute.

2.1.9 Calibration and other gases. Gases used for calibration, fuel, and combustion air (if required) are contained in compressed gas cylinders. All calibration gases shall be traceable to NIST standards and shall be certified by the manufacturer to ±1 percent of the tag value. Additionally, the manufacturer of the cylinder should provide a recommended shelf life for each calibration gas cylinder over which the concentration does not change more than ±2 percent from the certified value. For calibration gas values not generally available, alternative methods for preparing calibration gas mixtures, such as dilution systems, may be used with prior approval.

2.1.9.1 Fuel. A 40 percent H2/60 percent He or 40 percent H2/60 percent N2 gas mixture is recommended to avoid an oxygen synergism effect that reportedly occurs when oxygen concentration varies significantly from a mean value.

2.1.9.2 Carrier gas. High purity air with less than 1 ppm of organic material (as propane or carbon equivalent) or less than 0.1 percent of the span value, whichever is greater.

2.1.9.3 FIA linearity calibration gases. Low-, mid-, and high-range gas mixture standards with nominal propane concentrations of 20-30, 45-55, and 70-80 percent of the span value in air, respectively. Other calibration values and other span values may be used if it can be shown that more accurate measurements would be achieved.

2.1.10 Particulate filter. An in-stack or an out-of-stack glass fiber filter is recommended if exhaust gas particulate loading is significant. An out-of-stack filter must be heated to prevent any condensation unless it can be demonstrated that no condensation occurs.

2.2 Fugitive emissions volumetric flow rate.

2.2.1 Method 2 or 2A apparatus. For determining volumetric flow rate.

2.2.2 Method 3 apparatus and reagents. For determining molecular weight of the gas stream. An estimate of the molecular weight of the gas stream may be used if it can be justified.

2.2.3 Method 4 apparatus and reagents. For determining moisture content, if necessary.

2.3 Temporary total enclosure. The criteria for designing a TTE are discussed in Procedure T.

3. Determination of Volumetric Flow Rate of Fugitive Emissions

3.1 Locate all points where emissions are exhausted from the TTE. Using Method 1, determine the sampling points. Be sure to check each site for cyclonic or swirling flow.

3.2 Measure the velocity at each sampling site at least once every hour during each sampling run using Method 2 or 2A.

4. Determination of VOC Content of Fugitive Emissions

4.1 Analysis duration. Measure the VOC responses at each fugitive emission point during the entire test run or, if applicable, while the process is operating. If there are multiple emission locations, design a sampling system to allow a single FIA to be used to determine the VOC responses at all sampling locations.

4.2 Gas VOC concentration.

4.2.1 Assemble the sample train as shown in Figure 1. Calibrate the FIA and conduct a system check according to the procedures in sections 5.1 and 5.3, respectively.

4.2.2 Install the sample probe so that the probe is centrally located in the stack, pipe, or duct, and is sealed tightly at the stack port connection.

4.2.3 Inject zero gas at the calibration valve assembly. Allow the measurement system response to reach zero. Measure the system response time as the time required for the system to reach the effluent concentration after the calibration valve has been returned to the effluent sampling position.

4.2.4 Conduct a system check before and a system drift check after each sampling run according to the procedures in sections 5.2 and 5.3. If the drift check following a run indicates unacceptable performance, the run is not valid. The tester may elect to perform system drift checks during the run not to exceed one drift check per hour.

4.2.5 Verify that the sample lines, filter, and pump temperatures are 120 ±5 °C.

4.2.6 Begin sampling at the start of the test period and continue to sample during the entire run. Record the starting and ending times and any required process information as appropriate. If multiple emission locations are sampled using a single FIA, sample at each location for the same amount of time (e.g., 2 minutes) and continue to switch from one location to another for the entire test run. Be sure that total sampling time at each location is the same at the end of the test run. Collect at least 4 separate measurements from each sample point during each hour of testing. Disregard the response measurements at each sampling location until two times the response time of the measurement system has elapsed. Continue sampling for at least 1 minute and record the concentration measurements.

4.3 Background concentration.

4.3.1 Determination of VOC background concentration.

4.3.1.1 Locate all NDO's of the TTE. A sampling point shall be centrally located outside of the TTE at 4 equivalent diameters from each NDO, if possible. If there are more than 6 NDO's, choose 6 sampling points evenly spaced among the NDO's.

4.3.1.2 Assemble the sample train as shown in Figure 2. Calibrate the FIA and conduct a system check according to the procedures in sections 5.1 and 5.3.

4.3.1.3 Position the probe at the sampling location.

4.3.1.4 Determine the response time, conduct the system check and sample according to the procedures described in sections 4.2.3 to 4.2.6.

4.4 Alternative procedure. The direct interface sampling and analysis procedure described in section 7.2 of Method 18 may be used to determine the gas VOC concentration. The system must be designed to collect and analyze at least one sample every 10 minutes.

5. Calibration and Quality Assurance

5.1 FIA calibration and linearity check. Make necessary adjustments to the air and fuel supplies for the FIA and ignite the burner. Allow the FIA to warm up for the period recommended by the manufacturer. Inject a calibration gas into the measurement system and adjust the back-pressure regulator to the value required to achieve the flow rates specified by the manufacturer. Inject the zero- and the high-range calibration gases and adjust the analyzer calibration to provide the proper responses. Inject the low- and mid-range gases and record the responses of the measurement system. The calibration and linearity of the system are acceptable if the responses for all four gases are within 5 percent of the respective gas values. If the performance of the system is not acceptable, repair or adjust the system and repeat the linearity check. Conduct a calibration and linearity check after assembling the analysis system and after a major change is made to the system.

5.2 Systems drift checks. Select the calibration gas concentration that most closely approximates that of the fugitive gas emissions to conduct the drift checks. Introduce the zero and calibration gas at the calibration valve assembly and verify that the appropriate gas flow rate and pressure are present at the FIA. Record the measurement system responses to the zero and calibration gases. The performance of the system is acceptable if the difference between the drift check measurement and the value obtained in section 5.1 is less than 3 percent of the span value. Conduct a system drift check at the end of each run.

5.3 System check. Inject the high range calibration gas at the inlet of the sampling probe and record the response. The performance of the system is acceptable if the measurement system response is within 5 percent of the value obtained in section 5.1 for the high range calibration gas. Conduct a system check before each test run.

5.4 Analysis audit. Immediately before each test analyze an audit cylinder as described in section 5.2. The analysis audit must agree with the audit cylinder concentration within 10 percent.

6. Nomenclature Ai = area of NDO i, ft 2. AN = total area of all NDO's in the enclosure, ft 2. CBi = corrected average VOC concentration of background emissions at point i, ppm propane. CB = average background concentration, ppm propane. CDH = average measured concentration for the drift check calibration gas, ppm propane. CDO = average system drift check concentration for zero concentration gas, ppm propane. CFj = corrected average VOC concentration of fugitive emissions at point j, ppm propane. CH = actual concentration of the drift check calibration gas, ppm propane. Ci = uncorrected average background VOC concentration at point i, ppm propane. Cj = uncorrected average VOC concentration measured at point j, ppm propane. F = total VOC content of fugitive emissions, kg. K1 = 1.830 × 10−6 kg/(m 3−ppm). n = number of measurement points. QFj = average effluent volumetric flow rate corrected to standard conditions at fugitive emissions point j, m 3/min. TF = total duration of fugitive emissions sampling run, min. 7. Calculations

7.1 Total VOC fugitive emissions.

7.2 VOC concentration of the fugitive emissions at point j.

7.3 Background VOC concentration at point i.

7.4 Average background concentration.

Note:

If the concentration at each point is within 20 percent of the average concentration of all points, the terms “Ai” and “AN” may be deleted from Equation 4.

Procedure L—VOC Input 1. Introduction

1.1 Applicability. This procedure is applicable for determining the input of volatile organic compounds (VOC). It is intended to be used as a segment in the development of liquid/gas protocols for determining VOC capture efficiency (CE) for surface coating and printing operations.

1.2 Principle. The amount of VOC introduced to the process (L) is the sum of the products of the weight (W) of each VOC containing liquid (ink, paint, solvent, etc.) used and its VOC content (V). A sample of each VOC containing liquid is analyzed with a flame ionization analyzer (FIA) to determine V.

1.3 Estimated measurement uncertainty. The measurement uncertainties are estimated for each VOC containing liquid as follows: W=±2.0 percent and V=±12.0 percent. Based on these numbers, the probable uncertainty for L is estimated at about ±12.2 percent for each VOC containing liquid.

1.4 Sampling requirements. A capture efficiency test shall consist of at least three sampling runs. The sampling time for each run should be at least 8 hours, unless otherwise approved.

1.5 Notes. Because this procedure is often applied in highly explosive areas, caution and care should be exercised in choosing appropriate equipment and installing and using the equipment. Mention of trade names or company products does not constitute endorsement. All gas concentrations (percent, ppm) are by volume, unless otherwise noted.

2. Apparatus and Reagents

2.1 Liquid weight.

2.1.1 Balances/digital scales. To weigh drums of VOC containing liquids to within 0.2 lb.

2.1.2 Volume measurement apparatus (alternative). Volume meters, flow meters, density measurement equipment, etc., as needed to achieve same accuracy as direct weight measurements.

2.2 VOC content (flame ionization analyzer technique). The liquid sample analysis system is shown in Figures 1 and 2. The following equipment is required:

2.2.1 Sample collection can. An appropriately sized metal can to be used to collect VOC containing materials. The can must be constructed in such a way that it can be grounded to the coating container.

2.2.2 Needle valves. To control gas flow.

2.2.3 Regulators. For carrier gas and calibration gas cylinders.

2.2.4 Tubing. Teflon or stainless steel tubing with diameters and lengths determined by connection requirements of equipment. The tubing between the sample oven outlet and the FIA shall be heated to maintain a temperature of 120 ±5 °C.

2.2.5 Atmospheric vent. A tee and 0- to 0.5-liter/min rotameter placed in the sampling line between the carrier gas cylinder and the VOC sample vessel to release the excess carrier gas. A toggle valve placed between the tee and the rotameter facilitates leak tests of the analysis system.

2.2.6 Thermometer. Capable of measuring the temperature of the hot water bath to within 1 °C.

2.2.7 Sample oven. Heated enclosure, containing calibration gas coil heaters, critical orifice, aspirator, and other liquid sample analysis components, capable of maintaining a temperature of 120 ±5 °C.

2.2.8 Gas coil heaters. Sufficient lengths of stainless steel or Teflon tubing to allow zero and calibration gases to be heated to the sample oven temperature before entering the critical orifice or aspirator.

2.2.9 Water bath. Capable of heating and maintaining a sample vessel temperature of 100 ±5 °C.

2.2.10 Analytical balance. To measure ±0.001 g.

2.2.11 Disposable syringes. 2-cc or 5-cc.

2.2.12 Sample vessel. Glass, 40-ml septum vial. A separate vessel is needed for each sample.

2.2.13 Rubber stopper. Two-hole stopper to accommodate 3.2-mm ( 1/8-in.) Teflon tubing, appropriately sized to fit the opening of the sample vessel. The rubber stopper should be wrapped in Teflon tape to provide a tighter seal and to prevent any reaction of the sample with the rubber stopper. Alternatively, any leak-free closure fabricated of non-reactive materials and accommodating the necessary tubing fittings may be used.

2.2.14 Critical orifices. Calibrated critical orifices capable of providing constant flow rates from 50 to 250 ml/min at known pressure drops. Sapphire orifice assemblies (available from O'Keefe Controls Company) and glass capillary tubing have been found to be adequate for this application.

2.2.15 Vacuum gauge. 0 -to 760-mm (0- to 30-in.) Hg U-Tube manometer or vacuum gauge.

2.2.16 Pressure gauge. Bourdon gauge capable of measuring the maximum air pressure at the aspirator inlet (e.g., 100 psig).

2.2.17 Aspirator. A device capable of generating sufficient vacuum at the sample vessel to create critical flow through the calibrated orifice when sufficient air pressure is present at the aspirator inlet. The aspirator must also provide sufficient sample pressure to operate the FIA. The sample is also mixed with the dilution gas within the aspirator.

2.2.18 Soap bubble meter. Of an appropriate size to calibrate the critical orifices in the system.

2.2.19 Organic concentration analyzer. An FIA with a span value of 1.5 times the expected concentration as propane; however other span values may be used if it can be demonstrated that they would provide more accurate measurements. The system shall be capable of meeting or exceeding the following specifications:

2.2.19.1 Zero drift. Less than ±3.0 percent of the span value.

2.2.19.2 Calibration drift. Less than ±3.0 percent of span value.

2.2.19.3 Calibration error. Less than ±5.0 percent of the calibration gas value.

2.2.20 Integrator/data acquisition system. An analog or digital device or computerized data acquisition system used to integrate the FIA response or compute the average response and record measurement data. The minimum data sampling frequency for computing average or integrated values is one measurement value every 5 seconds. The device shall be capable of recording average values at least once per minute.

2.2.21 Chart recorder (optional). A chart recorder or similar device is recommended to provide a continuous analog display of the measurement results during the liquid sample analysis.

2.2.22 Calibration and other gases. For calibration, fuel, and combustion air (if required) contained in compressed gas cylinders. All calibration gases shall be traceable to NIST standards and shall be certified by the manufacturer to ±1 percent of the tag value. Additionally, the manufacturer of the cylinder should provide a recommended shelf life for each calibration gas cylinder over which the concentration does not change more than ±2 percent from the certified value. For calibration gas values not generally available, alternative methods for preparing calibration gas mixtures, such as dilution systems, may be used with prior approval.

2.2.22.1 Fuel. A 40 percent H2/60 percent He or 40 percent H2/60 percent N2 gas mixture is recommended to avoid an oxygen synergism effect that reportedly occurs when oxygen concentration varies significantly from a mean value.

2.2.22.2 Carrier gas. High purity air with less than 1 ppm of organic material (as propane) or less than 0.1 percent of the span value, whichever is greater.

2.2.22.3 FIA linearity calibration gases. Low-, mid-, and high-range gas mixture standards with nominal propane concentrations of 20-30, 45-55, and 70-80 percent of the span value in air, respectively. Other calibration values and other span values may be used if it can be shown that more accurate measurements would be achieved.

2.2.22.4 System calibration gas. Gas mixture standard containing propane in air, approximately the undiluted VOC concentration expected for the liquid samples.

3. Determination of Liquid Input Weight

3.1 Weight difference. Determine the amount of material introduced to the process as the weight difference of the feed material before and after each sampling run. In determining the total VOC containing liquid usage, account for: (a) The initial (beginning) VOC containing liquid mixture; (b) any solvent added during the test run; (c) any coating added during the test run; and (d) any residual VOC containing liquid mixture remaining at the end of the sample run.

3.1.1 Identify all points where VOC containing liquids are introduced to the process. To obtain an accurate measurement of VOC containing liquids, start with an empty fountain (if applicable). After completing the run, drain the liquid in the fountain back into the liquid drum (if possible), and weigh the drum again. Weigh the VOC containing liquids to ±0.5 percent of the total weight (full) or ±0.1 percent of the total weight of VOC containing liquid used during the sample run, whichever is less. If the residual liquid cannot be returned to the drum, drain the fountain into a preweighted empty drum to determine the final weight of the liquid.

3.1.2 If it is not possible to measure a single representative mixture, then weigh the various components separately (e.g., if solvent is added during the sampling run, weigh the solvent before it is added to the mixture). If a fress drum of VOC containing liquid is needed during the run, then weigh both the empty drum and fresh drum.

3.2 Volume measurement (alternative). If direct weight measurements are not feasible, the tester may use volume meters and flow rate meters (and density measurements) to determine the weight of liquids used if it can be demonstrated that the technique produces results equivalent to the direct weight measurements. If a single representative mixture cannot be measured, measure the components separately.

4. Determination of VOC Content in Input Liquids

4.1 Collection of liquid samples.

4.1.1 Collect a 100-ml or larger sample of the VOC containing liquid mixture at each application location at the beginning and end of each test run. A separate sample should be taken of each VOC containing liquid added to the application mixture during the test run. If a fresh drum is needed during the sampling run, then obtain a sample from the fresh drum.

4.1.2 When collecting the sample, ground the sample container to the coating drum. Fill the sample container as close to the rim as possible to minimize the amount of headspace.

4.1.3 After the sample is collected, seal the container so the sample cannot leak out or evaporate.

4.1.4 Label the container to identify clearly the contents.

4.2 Liquid sample VOC content.

4.2.1 Assemble the liquid VOC content analysis system as shown in Figure 1.

4.2.2 Permanently identify all of the critical orifices that may be used. Calibrate each critical orifice under the expected operating conditions (i.e., sample vacuum and temperature) against a volume meter as described in section 5.3.

4.2.3 Label and tare the sample vessels (including the stoppers and caps) and the syringes.

4.2.4 Install an empty sample vessel and perform a leak test of the system. Close the carrier gas valve and atmospheric vent and evacuate the sample vessel to 250 mm (10 in.) Hg absolute or less using the aspirator. Close the toggle valve at the inlet to the aspirator and observe the vacuum for at least one minute. If there is any change in the sample pressure, release the vacuum, adjust or repair the apparatus as necessary and repeat the leak test.

4.2.5 Perform the analyzer calibration and linearity checks according to the procedure in section 5.1. Record the responses to each of the calibration gases and the back-pressure setting of the FIA.

4.2.6 Establish the appropriate dilution ratio by adjusting the aspirator air supply or substituting critical orifices. Operate the aspirator at a vacuum of at least 25 mm (1 in.) Hg greater than the vacuum necessary to achieve critical flow. Select the dilution ratio so that the maximum response of the FIA to the sample does not exceed the high-range calibration gas.

4.2.7 Perform system calibration checks at two levels by introducing compressed gases at the inlet to the sample vessel while the aspirator and dilution devices are operating. Perform these checks using the carrier gas (zero concentration) and the system calibration gas. If the response to the carrier gas exceeds ±0.5 percent of span, clean or repair the apparatus and repeat the check. Adjust the dilution ratio as necessary to achieve the correct response to the upscale check, but do not adjust the analyzer calibration. Record the identification of the orifice, aspirator air supply pressure, FIA back-pressure, and the responses of the FIA to the carrier and system calibration gases.

4.2.8 After completing the above checks, inject the system calibration gas for approximately 10 minutes. Time the exact duration of the gas injection using a stopwatch. Determine the area under the FIA response curve and calculate the system response factor based on the sample gas flow rate, gas concentration, and the duration of the injection as compared to the integrated response using Equations 2 and 3.

4.2.9 Verify that the sample oven and sample line temperatures are 120 ±5 °C and that the water bath temperature is 100 ±5 °C.

4.2.10 Fill a tared syringe with approximately 1 g of the VOC containing liquid and weigh it. Transfer the liquid to a tared sample vessel. Plug the sample vessel to minimize sample loss. Weigh the sample vessel containing the liquid to determine the amount of sample actually received. Also, as a quality control check, weigh the empty syringe to determine the amount of material delivered. The two coating sample weights should agree within ±0.02 g. If not, repeat the procedure until an acceptable sample is obtained.

4.2.11 Connect the vessel to the analysis system. Adjust the aspirator supply pressure to the correct value. Open the valve on the carrier gas supply to the sample vessel and adjust it to provide a slight excess flow to the atmospheric vent. As soon as the initial response of the FIA begins to decrease, immerse the sample vessel in the water bath. (Applying heat to the sample vessel too soon may cause the FID response to exceed the calibrated range of the instrument, and thus invalidate the analysis.)

4.2.12 Continuously measure and record the response of the FIA until all of the volatile material has been evaporated from the sample and the instrument response has returned to the baseline (i.e., response less than 0.5 percent of the span value). Observe the aspirator supply pressure, FIA back-pressure, atmospheric vent, and other system operating parameters during the run; repeat the analysis procedure if any of these parameters deviate from the values established during the system calibration checks in Section 4.2.7. After each sample perform the drift check described in Section 5.2. If the drift check results are acceptable, calculate the VOC content of the sample using the equations in Section 7. Integrate the area under the FIA response curve, or determine the average concentration response and the duration of sample analysis.

5. Calibration and Quality Assurance

5.1 FIA calibration and linearity check. Make necessary adjustments to the air and fuel supplies for the FIA and ignite the burner. Allow the FIA to warm up for the period recommended by the manufacturer. Inject a calibration gas into the measurement system and adjust the back-pressure regulator to the value required to achieve the flow rates specified by the manufacturer. Inject the zero- and the high-range calibration gases and adjust the analyzer calibration to provide the proper responses. Inject the low- and mid-range gases and record the responses of the measurement system. The calibration and linearity of the system are acceptable if the responses for all four gases are within 5 percent of the respective gas values. If the performance of the system is not acceptable, repair or adjust the system and repeat the linearity check. Conduct a calibration and linearity check after assembling the analysis system and after a major change is made to the system.

5.2 Systems drift checks. After each sample, repeat the system calibration checks in Section 4.2.7 before any adjustments to the FIA or measurement system are made. If the zero or calibration drift exceeds ±3 percent of the span value, discard the result and repeat the analysis.

5.3 Critical orifice calibration.

5.3.1 Each critical orifice must be calibrated at the specific operating conditions that it will be used. Therefore, assemble all components of the liquid sample analysis system as shown in Figure 3. A stopwatch is also required.

5.3.2 Turn on the sample oven, sample line, and water bath heaters and allow the system to reach the proper operating temperature. Adjust the aspirator to a vacuum of 380 mm (15 in.) Hg vacuum. Measure the time required for one soap bubble to move a known distance and record barometric pressure.

5.3.3 Repeat the calibration procedure at a vacuum of 406 mm (16 in.) Hg and at 25-mm (1-in.) Hg intervals until three consecutive determinations provide the same flow rate. Calculate the critical flow rate for the orifice in ml/min at standard conditions. Record the vacuum necessary to achieve critical flow.

6. Nomenclature AL = area under the response curve of the liquid sample, area count. AS = area under the response curve of the calibration gas, area count. CS = actual concentration of system calibration gas, ppm propane. K = 1.830 × 10−9 g/(ml-ppm). L = total VOC content of liquid input, kg. ML = mass of liquid sample delivered to the sample vessel, g. q = flow rate through critical orifice, ml/min. RF = liquid analysis system response factor, g/area count. TS = total gas injection time for system calibration gas during integrator calibration, min. VFj = final VOC fraction of VOC containing liquid j. VIj = initial VOC fraction of VOC containing liquid j. VAj = VOC fraction of VOC containing liquid j added during the run. V = VOC fraction of liquid sample. WFj = weight of VOC containing liquid j remaining at end of the run, kg. WIj = weight of VOC containing liquid j at beginning of the run, kg. WAj = weight of VOC containing liquid j added during the run, kg. 7. Calculations

7.1 Total VOC content of the input VOC containing liquid.

7.2 Liquid sample analysis system response factor for systems using intergrators, grams/area counts.

7.3 VOC content of the liquid sample.

Procedure T—Criteria for and Verification of a Permanent or Temporary Total Enclosure 1. Introduction

1.1 Applicability. This procedure is used to determine whether a permanent or temporary enclosure meets the criteria of a total enclosure.

1.2 Principle. An enclosure is evaluated against a set of criteria. If the criteria are met and if all the exhaust gases are ducted to a control device, then the volatile organic compounds (VOC) capture efficiency (CE) is assumed to be 100 percent and CE need not be measured. However, if part of the exhaust gas stream is not ducted to a control device, CE must be determined.

2. Definitions

2.1 Natural Draft Opening (NDO)—Any permanent opening in the enclosure that remains open during operation of the facility and is not connected to a duct in which a fan is installed.

2.2 Permanent Total Enclosure (PTE)—A permanently installed enclosure that completely surrounds a source of emissions such that all VOC emissions are captured and contained for discharge through a control device.

2.3 Temporary Total Enclosure (TTE)—A temporarily installed enclosure that completely surrounds a source of emissions such that all VOC emissions are captured and contained for discharge through ducts that allow for the accurate measurement of VOC rates.

3. Criteria of a Temporary Total Enclosure

3.1 Any NDO shall be at least 4 equivalent opening diameters from each VOC emitting point.

3.2 Any exhaust point from the enclosure shall be at least 4 equivalent duct or hood diameters from each NDO.

3.3 The total area of all NDO's shall not exceed 5 percent of the surface area of the enclosure's four walls, floor, and ceiling.

3.4 The average facial velocity (FV) of air through all NDO's shall be at least 3,600 m/hr (200 fpm). The direction of air through all NDO's shall be into the enclosure.

3.5 All access doors and windows whose areas are not included in section 3.3 and are not included in the calculation in section 3.4 shall be closed during routine operation of the process.

4. Criteria of a Permanent Total Enclosure

4.1 Same as sections 3.1 and 3.3-3.5.

4.2 All VOC emissions must be captured and contained for discharge through a control device.

5. Procedure

5.1 Determine the equivalent diameters of the NDO's and determine the distances from each VOC emitting point to all NDO's. Determine the equivalent diameter of each exhaust duct or hood and its distance to all NDO's. Calculate the distances in terms of equivalent diameters. The number of equivalent diameters shall be at least 4.

5.2 Measure the total area (At) of the enclosure and the total area (AN) of all NDO's of the enclosure. Calculate the NDO to enclosure area ratio (NEAR) as follows:

NEAR = AN/At

The NEAR must be ≤0.05.

5.3 Measure the volumetric flow rate, corrected to standard conditions, of each gas stream exiting the enclosure through an exhaust duct or hood using EPA Method 2. In some cases (e.g., when the building is the enclosure), it may be necessary to measure the volumetric flow rate, corrected to standard conditions, of each gas stream entering the enclosure through a forced makeup air duct using Method 2. Calculate FV using the following equation:

FV=[QO−QI]/AN Where: QO = the sum of the volumetric flow from all gas streams exiting the enclosure through an exhaust duct or hood. QI = the sum of the volumetric flow from all gas streams into the enclosure through a forced makeup air duct; zero, if there is no forced makeup air into the enclosure. AN = total area of all NDO's in enclosure.

The FV shall be at least 3,600 m/hr (200 fpm).

5.4 Verify that the direction of air flow through all NDO's is inward. Use streamers, smoke tubes, tracer gases, etc. Strips of plastic wrapping film have been found to be effective. Monitor the direction of air flow at intervals of at least 10 minutes for at least 1 hour.

6. Quality Assurance

6.1 The success of this protocol lies in designing the TTE to simulate the conditions that exist without the TTE, i.e., the effect of the TTE on the normal flow patterns around the affected facility or the amount of fugitive VOC emissions should be minimal. The TTE must enclose the application stations, coating reservoirs, and all areas from the application station to the oven. The oven does not have to be enclosed if it is under negative pressure. The NDO's of the temporary enclosure and a fugitive exhaust fan must be properly sized and placed.

6.2 Estimate the ventilation rate of the TTE that best simulates the conditions that exist without the TTE, i.e., the effect of the TTE on the normal flow patterns around the affected facility or the amount of fugitive VOC emissions should be minimal. Figure 1 may be used as an aid. Measure the concentration (CG) and flow rate (QG) of the captured gas stream, specify a safe concentration (CF) for the fugitive gas stream, estimate the CE, and then use the plot in Figure 1 to determine the volumetric flowrate of the fugitive gas stream (QF). A fugitive VOC emission exhaust fan that has a variable flow control is desirable.

6.2.1 Monitor the concentration of VOC into the capture device without the TTE. To minimize the effect of temporal variation on the captured emissions, the baseline measurement should be made over as long a time period as practical. However, the process conditions must be the same for the measurement in section 6.2.3 as they are for this baseline measurement. This may require short measuring times for this quality control check before and after the construction of the TTE.

6.2.2 After the TTE is constructed, monitor the VOC concentration inside the TTE. This concentration shall continue to increase and must not exceed the safe level according to OSHA requirements for permissible exposure limits. An increase in VOC concentration indicates poor TTE design or poor capture efficiency.

6.2.3 Monitor the concentration of VOC into the capture device with the TTE. To limit the effect of the TTE on the process, the VOC concentration with and without the TTE must be within ±10 percent. If the measurements do not agree, adjust the ventilation rate from the TTE until they agree within 10 percent.

[55 span 26856, June 29, 1990; 55 span 31981, Aug. 6, 1990; 55 span 39774, 39775, Sept. 28, 1990, as amended at 56 span 24723, May 31, 1991; 56 span 33712, July 23, 1991; 57 span 3946, Feb. 3, 1992; 57 span 7550, Mar. 3, 1992; 57 span 27936, June 23, 1992; 58 span 31653, June 4, 1993; 58 span 34908, June 30, 1993; 59 span 14112, Mar. 25, 1994; 59 span 46569, Sept. 9, 1994; 60 span 41, Jan. 3, 1995; 60 span 13045, Mar. 10, 1995; 60 span 14900, Mar. 21, 1995; 60 span 43387, 43393, 43395, Aug. 21, 1995; 61 span 54559, Oct. 21, 1996]

§ 52.742 - Incorporation by reference.

The materials listed below are incorporated by reference in the corresponding sections noted. The incorporation by reference was approved by the Director of the Office of Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. These materials are incorporated as they exist on the date of approval, and a notice of any change in these materials will be published in the Federal Register. The materials are available from the sources listed below.

(a) The following material is available for purchase from the American Society for Testing and Materials (ASTM), 1916 Race Street, Philadelphia, PA 19103.

(1) ASTM D1475-85, Standard Test Method for Density of Paint, Varnish, Lacquer, and Related Products, for § 52.741(a)(4)(i)(B)(3)(i).

(2) ASTM D2369-87, Standard Test Method for Volatile Content of Coatings, for § 52.741(a)(4)(i)(B)(3)(ii).

(3) ASTM D3792-86, Standard Test Method for Water Content of Water-Reducible Paints by Direct Injection into a Gas Chromatograph, for § 52.741(a)(4)(i)(B)(3)(iii).

(4) ASTM D4017-81(Reapproved 1987), Standard Test Method for Water in Paints and Paint Materials by Karl Fischer Method, for § 52.741(a)(4)(i)(B)(3)(iv).

(5) ASTM D4457-85, Standard Test Method for Determination of Dichloromethane and 1,1,1-Trichloroethane in Paints and Coatings by Direct Injection into a Gas Chromatograph, for § 52.741(a)(4)(i)(B)(3)(v).

(6) ASTM D2697-86, Standard Test Method for Volume Nonvolatile Matter in Clear or Pigmented Coatings, for § 52.741(a)(4)(i)(B)(3)(vi).

(7) ASTM D3980-87, Standard Practice for Interlaboratory Testing of Paint and Related Materials, for § 52.741(a)(4)(i)(B)(3)(vi).

(8) ASTM E180-85, Standard Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial Chemicals, for § 52.741(a)(4)(i)(B)(3)(viii).

(9) ASTM D2372-85, Standard Method of Separation of Vehicle from Solvent-Reducible Paints, for § 52.741(a)(4)(i)(B)(3)(ix).

(10) ASTM D2879-86, Standard Test Method for Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope, for § 52.741(a)(3), (a)(8)(ii), (a)(9)(iii), and (a)(10)(iii).

(11) ASTM D323-82, Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method), for § 52.741(a)(3).

(12) ASTM D86-82, Standard Method for Distillation of Petroleum Products, for § 52.741(a)(3).

(13) ASTM D3925-81(Reapproved 1985), Standard Practice for Sampling Liquid Paints and Related Pigment Coatings, for § 52.741(a)(4)(i)(A)(1).

(14) ASTM E300-86, Standard Practice for Sampling Industrial Chemicals, for § 52.741(a)(4)(i)(A)(2).

(b) The Evaporation Loss From External Floating-Roof Tanks, Publication 2517, second edition, February 1980, for § 52.741(a)(3) is available for purchase from the American Petroleum Institute, 2101 L Street, NW., Washington, DC 20037.

(c) The Standard Industrial Classification Manual, 1987, for § 52.741(a)(3) is available for purchase from the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.

(d) 35 Illinois Administrative Code 215, June 1989, subparts (B), (E) (sections 215.182, 215.183, and 215.184), (K) (sections 215.301 and 215.302), (Q) (excluding sections 215.432 and 215.436), (R) (excluding sections 215.447, 215.450, and 215.452), (S), (V), (X), (Y) (sections 215.582, 215.583, and 215.584), and (Z) of 35 Ill. Adm. Code 215 for § 52.741 (d)(l)-(d)(3); (e)(3), (e)(4); (h)(2); (i)(1), (i)(2); (j)(1)-(j)(3); (q)(1); (s)(1); (u)(1), (3); (v)(1); (w)(1); and (x)(1), (x)(3) is available from the United States Environmental Protection Agency, Air and Radiation Division, Region V, 230 S. Dearborn, Chicago, IL, 60604.

[55 FR 26909, June 29, 1990]

§ 52.743 - Continuous monitoring.

(a) Alternative monitoring requirements established under Section 201.402 of Title 35, IAC must be either: Incorporated into a federally enforceable operating permit or construction permit or submitted to USEPA for approval as a revision to the Illinois State Implementation Plan (SIP). Illinois shall set forth alternative emissions monitoring and reporting requirements to satisfy the intent of 40 CFR part 51, appendix P whenever Illinois exempts any source subject to Section 201.401 from installing continuous emission monitoring systems. Illinois may exempt a source if the source cannot install a continuous emission monitoring system because of physical plant limitations or extreme economic reasons, according to the criteria of Section 201.402.

(b) As codified at 40 CFR 52.737 (USEPA's approval of the Illinois operating permit program for the purpose of issuing federally enforceable construction and operating permits), USEPA reserves the right to deem an operating permit not federally enforceable. Such a determination will be made according to appropriate procedures including operating permit requirements promulgated at 54 FR 27274 (June 28, 1989) and will be based upon either; the permit, permit approval procedures or state or local permit requirements which do not conform with the operating permit program requirements or the requirements of USEPA's underlying regulations. Among other things, underlying requirements include 40 CFR 51.214 and part 51, appendix P and Illinois' approved SIP, 40 CFR part 52. Should USEPA deem an operating or construction permit containing alternative monitoring requirements not federally enforceable, the underlying continuous monitoring requirements at Section 201.401 of the State rule would be the Federal requirements contained in the SIP to which the source would be subject. This interpretation of the impact of an operating permit deemed not federally enforceable by USEPA on a source to which it was issued was acknowledged by the State in a March 3, 1993, letter from Bharat Mathur, Chief, Bureau of Air, Illinois Environmental Protection Agency, to Stephen Rothblatt, Chief, Regulation Development Branch, Region 5, USEPA.

[58 FR 17783, Apr. 6, 1993]

§ 52.744 - Small business stationary source technical and environmental compliance assistance program.

The Illinois program submitted on November 12, 1992, as a requested revision to the Illinois State Implementation Plan satisfies the requirements of section 507 of the Clean Air Act Amendments of 1990.

[58 FR 45451, Aug. 30, 1993]

§§ 52.745-52.746 - §[Reserved]

§ 52.750 - Original identification of plan section.

(a) This section identified the original “Air Quality Implementation Plan for the State of Illinois” and all revisions submitted by Illinois that were Federally-approved prior to June 1, 2017.

(b) The plan was officially submitted on January 31, 1972.

(c) The plan revision listed below were submitted on the dates specified.

(1) The role of the City of Chicago as a local agent was defined in a letter from the State Environmental Protection Agency on March 13, 1972.

(2) Copies of the Illinois Pollution Control Board Regulations, Chapter 2, Parts I, II and III were submitted May 4, 1972, by the Governor.

(3) A document describing the role of the Chicago Department of Environmental Control was submitted July 28, 1972, by the State Environmental Protection Agency.

(4) Copies of the revisions to the State air episode regulations were submitted on August 29, 1972, by the Governor.

(5) Compliance schedules submitted on March 13, 1973, by the Pollution Control Board.

(6) Compliance schedules submitted on April 3, 1973, by the Pollution Control Board.

(7) Transportation control plan submitted on April 17, 1973, by the Pollution Control Board.

(8) Compliance schedules submitted on May 3, 1973, by the Pollution Control Board.

(9) Compliance schedules submitted on June 15, 1973, by the Pollution Control Board.

(10) Compliance schedules submitted on August 7, 1973, by the Pollution Control Board.

(11) Information concerning the coal ban in the Chicago area was submitted on October 22, 1973, by Governor Walker.

(12) On July 22, 1976, the Director of the Illinois Environmental Protection Agency submitted revised emergency episode regulations.

(13) On November 29, 1977, the Director of the Illinois Environmental Protection Agency submitted grain handling and drying emission limitations as revisions to Rule 203.

(14) Revision consisting of an Illinois Pollution Control Board Order issued on July 20, 1978 to Commonwealth Edison Company, Christian County, Illinois and submitted on August 14, 1978 by the Illinois Environmental Protection Agency.

(15) Revision consisting of an Illinois Pollution Control Board Order issued to Shell Oil Company's Wood River refinery on December 14, 1978 by the Illinois Environmental Protection Agency.

(16) On April 4, 1979, the State submitted its draft nonattainment area plan for all areas designated nonattainment as of March 3, 1978 and as revised on October 5, 1978. This submittal contained a request for extensions of the statutory attainment deadline for CO and 03. The submittal also included a vehicle emission inspection and maintenance program and a new source review plan. Although the State submittal also included the following provisions, U.S. EPA is taking no action to include them in the federally approved SIP at this time: the portions of Rules 101, 103 and 105 relating to the provisions addressing malfunctions, general requirements of the Clean Air Act which are not Part D requirements, and the provisions covering open burning, mobile source emission standards, diesel locomotive emission standards, sulfur dioxide emissions for certain fuel combustion sources located outside major metropolitan areas, compliance dates for organic emission limitations, particulate emissions from low carbon waste incinerators, and adoption of Federal New Source Performance Standards. In addition, U.S. EPA is not rulemaking at this time on those portions of the following rules which contain specified changes made between the publication of the notice of proposed rulemaking and the final rulemaking action:

(i)-(iii) [Reserved]

(iv) The new materials in Section 4.11 of the Rules for Issuance of Permits to New or Modified Air Pollution Sources;

(v) The addition of a definition of “reconstruction” in Section 4.7 of the Rules for Issuance of Permits;

(vi) The procedure allowing external offsets contained in Section 10 of the Rules for Issuance of Permits.

(17) On August 29, 1979, the State submitted additional information and clarification for the nonattainment area plan in response to USEPA's July 2, 1979 notice of proposed rulemaking.

(18) On September 20, 1979, the State submitted a summary of public hearing comments on the plan.

(19) On October 30, 1979, the State submitted copies of Illinois Pollution Control Board final orders for control of VOC emissions from stationary sources (Rule 205), sources of fugitive particulate (Rule 203(f)), and particulate emissions from iron and steel sources (Rule 203(d)).

(20) On December 20, 1979, the State submitted a letter containing the dates that most of the regulatory and nonregulatory portions of the nonattainment area plans were finally adopted by the Illinois Pollution Control Board. Rule 205 containing RACT controls for stationary sources of VOC was effective in the State on July 18, 1979. Rule 203(f) governing fugitive dust emissions was effective in the State on September 18, 1979.

(21) On January 25, 1980, the State submitted a copy of finally enacted “Rules for the Issuance of Permits to New or Modified Air Pollution Sources Affecting Nonattainment Areas.” Sections 5.1(a)(2)(ii) and 5.1(a)(2)(iii) of these rules were reserved by the State. The effective date of these Rules was January 16, 1980.

(22) On March 21, 1979, the State of Illinois submitted to the USEPA revised regulations for control of sulfur dioxide emissions. On September 19, 1979, the State submitted additional information on these revised regulations to the USEPA.

(23) On January 17, 1980 and on February 7, 1980 the State submitted further information and clarifications to Rule 204.

(24) On September 19, 1979, the State of Illinois submitted a revision to Rule 204(e)(1) for the Commonwealth Edison Company. The revision approves an emission limitation of 105,162 lbs SO2/hour for the Kincaid Generating Station in Christian County, Illinois.

(25) On April 30, 1980, the State submitted revisions to the transportation control plan for northeast Illinois (Chicago).

(26) On December 20, 1979, the State of Illinois submitted a revision to provide for modification of the existing air quality surveillance network.

(27) On January 8, 1980, the State submitted an Opinion and Final Order of the Pollution Control Board (dated November 19, 1979) which deletes Rule 206(d) of Chapter 2 from the Illinois Air Pollution Control Regulations.

(28) On September 18, 1979, the State submitted a Final Order of the Pollution Control Board (dated April 12, 1979) which amended Rule 205(g)(1) of Chapter 2 of the Illinois Air Pollution Control Regulations.

(29) On July 21, 1981, the State submitted Volume 9 Lead, of the Illinois State Implementation Plan for Air Pollution Control for incorporation in the Illinois State Implementation Plan. This plan covers all areas in Illinois except for Granite City in the St. Louis Interstate AQCR.

(30) On July 29, 1980, the State submitted a May 29, 1980, Opinion and Order of the Illinois Pollution Control Board granting a variance from the requirements Rule 203(d)(8)(B) of Chapter 2 of the Air Pollution Control Regulations to Continental Grain Company's grain elevator located in Crossville, White County, Illinois. This variance expired July 1, 1980.

(31) On April 4, 1980, the State submitted a November 29, 1979, Opinion and Order of the Illinois Pollution Control Board (IPCB) and Supplementary IPCB Orders dated January 24, 1980, and February 7, 1980. These Orders grant 13 Caterpillar Tractor Company boilers a variance from the requirements of IPCB (A), Rule 203(g)(1)(C)(i) and/or Rule 203(g)(1)(D) which regulate particulate emissions from new and existing sources. No action is taken at this time on variance provisions for Mapleton facility boilers #2, 3, 4, and 5. This variance expired on October 8, 1981.

(32) On August 31, 1981, the State of Illinois submitted a revision to the Illinois State Implementation Plan in the form of a July 9, 1981, Order of the Illinois Pollution Control Board (R-77-15). This Order creates Rule 204(c)(1)(E) which establishes sulfur dioxide (SO2) emission limitations of 5.5 lbs/SO/MMBTU for solid fuel combustion sources having actual heat input not greater than 250 million BTU's per hour owned or operated by Bemis Company, Inc., Celotex Corporation or Sherex Corporation. On November 17, 1981, the State submitted additional information in support of this revision.

(33) On August 20, 1980, and March 20, 1981, the State submitted additional information on the transportation control plans for the Northeast Illinois (Chicago) Area.

(34) On October 15, 1980, the State submitted additional information on the transportation control plans for the Peoria Metropolitan Area.

(35) On April 1, 1981, the State submitted additional information on the transportation control plans for the St. Louis Metropolitan (Illinois) Area.

(36) On December 10, 1980, the State submitted a July 24, 1980, Opinion and Order of the Illinois Pollution Control Board and a September 18, 1980, Order of the Board granting Bunge Corporation's Cairo, Illinois soybean processing plant and grain elevator variance from Illinois Pollution Control Board's particulate emission standards under Rules 203(g)(1)(D) and 103(b)(1) of Chapter 2 of the Air Pollution Control Regulations through October 15, 1981.

(37) On July 17, 1980, the State submitted an April 3, 1980, Opinion and Order of the Illinois Pollution Control Board adopting a December 13, 1979, Proposed Opinion and Order of the Board which exempted certain small explosive waste incinerators from the requirements of Rule 203(e) Particulate Emission Standards and Limitations for incinerators and Rule 206(b) Carbon Monoxide Emissions Standards and Limitations for incinerators.

(38) On May 10, 1982, the State submitted a February 4, 1982, Illinois Pollution Control Board Opinion and Order (PCB 81-184) granting a variance from the requirements of Rules 205(m)(1)(B) and 204(n)(1)(G) of Chapter 2 of the Air Pollution Control Regulations to the Lyon Metal Products, Incorporated, Montgomery, Illinois facility. This variance expires on May 31, 1985.

(39) On October 1, 1981, the State submitted a report in satisfaction of the Total Suspended Particulate Control Strategy approval condition in which the State agreed to conduct an analysis of the potential air quality impact from storage piles with uncontrolled emissions of less than 50 tons per year, to submit the results of any analysis to EPA, to submit any necessary regulations to the Illinois Pollution Control Board, and promulgate and submit any necessary regulations to EPA. This report concluded that no further regulations were needed.

(40) EPA Study Volatile Organic Compound Emissions from Solvent Cleaning Operations in the State of Illinois (EPA 905/4-80-008) was prepared to satisfy the Ozone Control Strategy approval condition in which the State agreed to conduct a study to demonstrate that the three pound per hour, 15 pound per day exemption for solvent metal cleaners contained in Rule 205(k) represents RACT, to submit the results of the study to EPA, to submit the necessary regulations to the Illinois Pollution Control Board and promulgate and submit any necessary regulations to EPA. The State reviewed this report and in a February 11, 1981, letter to EPA noted their agreement with the findings of the report and indicated that because there was no need for further regulations, this condition is satisfied.

(41) On December 7, 1981, the State submitted a October 8, 1981, Illinois Pollution Control Board Final Order (R79-11). This Final Order amends Rule 203(g)(1) by adding subsection (E).

(42) On January 4, 1983, the State submitted a revision to the Illinois State Implementation Plan in the form of an October 27, 1982, Illinois Pollution Control Board (IPCB) Opinion and Order (PCB 82-88). This Opinion and Order grants a variance from the requirements of Rule 203(a) of Chapter 2 of the Air Pollution Control Regulations to a proposed fluidized bed combustion boiler at B.F. Goodrich's Henry County, Illinois facility. This variance continues until October 1, 1987, or until the facility is no longer subject to Rule 206(a), whichever comes first.

(43) On July 29, 1982, the State submitted a revision to the Illinois State Implementation Plan in the form of a May 28, 1981, Illinois Pollution Control Board (IPCB) Final Opinion of the Board (R78-17). This Final Opinion deletes Rule 204(c)(1)(D) and the reference to it in Rule 204(h) from the IPCB Air Pollution Control Regulations.

(44) On March 17, 1983, the Illinois Environmental Protection Agency (IEPA) submitted a revision to its ozone SIP for Chrysler's Belvidere facility. The revision request contains an alternative compliance time schedule with interim emission limitations which is in the form of a variance for prime coating and prime surface coating operations. Final compliance is changed from December 31, 1982 to December 31, 1987.

(45) On August 19, 1983, the State of Illinois submitted a revision to the Illinois State Implementation Plan in the form of a July 26, 1983, Order of the Illinois Pollution Control Board (R82-12). This Order creates Rule 313 which establishes 1.5 micrograms per cubic meter, maximum arithmetic mean, averaged over a calendar quarter as the State's ambient air quality standard for lead. The Board also adopted, as part of Rule 313, a measurement method for determining compliance with the standard.

(46) On August 15, 1983, the Illinois Environmental Protection Agency submitted a May 19, 1983, Opinion and Order (PCB-82-147) of the Illinois Pollution Control Board (IPCB) granting Del Monte Corporation's Can Manufacturing Plant No. 115 located in Rochelle, Ogle County, Illinois, a variance from the IPCB volatile organic compound emission standards under Rule 205(n)(1)(B)(i) and Rule 205(n)(1)(B)(vi) of Chapter 2: Air Pollution Regulations. The variance expires on December 31, 1984.

(47) On March 24, 1983, and May 3, 1983, the State submitted information that indicated that a February 21, 1980 (45 FR 11472), conditional approval of the incorporation of a revised Part D sulfur dioxide control strategy into the Illinois State Implementation Plan has been satisfied for Cincinnati, Pekin and Elm Grove Townships in Tazewell County and for Logan and Limestone Townships in Peoria County. This approval condition required that the SIP include a reanalysis of the Pekin, Illinois area; a submittal of the analysis results to USEPA; the proposal of any necessary regulations to the Illinois Pollution Control Board necessary to insure attainment and maintenance of the sulfur dioxide standard; and the promulgation of any necessary regulations. Any promulgated regulations must be submitted to USEPA.

(48)-(49) [Reserved]

(50) On May 3, 1983, the State requested that USEPA incorporate IPCB Rule 204 (f)(2) into the Illinois SIP. Rule 204(f)(2) was adopted by Illinois as part of a February 24, 1983, Order of the Board (R80-22). USEPA approves the incorporation of Rule 204(f)(2) as it pertains to Pekin Energy, a source in the Peoria major metropolitan area.

(51) On January 30, 1984, the State submitted Rule 204(f) as contained in a February 24, 1983, Order of the IPCB (R80-22) as it applies to sources in the Peoria Major Metropolitan area for incorporation in the SIP. USEPA approves the incorporation of Rule 204(f) into the SIP as it applies to all sources in Peoria and Tazewell Counties except Caterpillar Tractor Mapleton and East Peoria Plants. No action is taken on Rule 204(f) as it applies to the Chicago or St. Louis (Illinois—portion) Major Metropolitan Areas or on Rule 204(f) (1) and (2).

(52) [Reserved]

(53) On September 30, 1983, the State submitted a revision to the Illinois State Implementation Plan in the form of a lead plan to assure attainment and maintenance of the NAAQS in the Granite City area. The Illinois plan includes a discussion of air quality data measured since 1978, an emission inventory of three source categories capable of emitting lead, atmospheric modeling analyses and proposed necessary control strategies. On March 19, 1984, the State submitted five consent decrees entered by the State of Illinois with the Circuit Court for the Third Judicial Circuit of Madison County and filed March 16, 1984, for incorporation in the lead plan. These include People of the State of Illinois vs. Taracorp, Inc.; People of the State of Illinois vs. St. Louis Lead Recyclers; People of the State of Illinois vs. First Granite City National Bank; People of the State of Illinois, vs. Stackorp Inc.; and People of the State of Illinois vs. B.V. and G.V. Transport Company.

(54) [Reserved]

(55) On November 14, 1985, the State of Illinois submitted a negative declaration for natural gas/gasoline processing plants.

(i) Incorporation by reference. (A) Letter dated November 14, 1985, from Michael J. Hayes, Manager, Division of Air Pollution Control, Illinois Environmental Protection Agency.

(56) On June 19, 1984, the State submitted Illinois Environmental Protection Agency Rule 252 entitled, “Rules for Governing Public Participation in the Air Pollution Permit Program for Major Source in Nonattainment Areas.”

(i) Incorporation by reference. (A) Illinois Environmental Protection Agency Rule 252 entitled, “Rule for Governing Public Participation in the Air Pollution Permit Program for Major Sources in Nonattainment Areas,” published on June 8, 1984.

(57)-(60) [Reserved]

(61) On March 15, 1984 and June 14, 1984 the Illinois Environmental Protection Agency submitted commitments for satisfying several outstanding conditions to the sulfur dioxide [52.724(a)(1)] State Implementation Plan.

(62) On January 16, 1985, the Illinois Environmental Protection Agency submitted a variance from Illinois Rule 206(a).

(i) Incorporation by reference. (A) June 14, 1984, Opinion and Order of the Illinois Pollution Control Board (IPCB), PCB 84-19. This is a variance from Illinois Rule 206(a) until June 14, 1987, for CO emissions from a fluidized bed combustion boiler at Midwest Solvents Company's facility in Tazewell County, Illinois.

(63) On February 6, 1985, the Illinois Environmental Protection Agency (IEPA) submitted a site-specific revision to its total suspended particulates State Implementation Plan for Villa Grove's “Dump and Boot Pit” emissions in Champaign County, Illinois.

(i) Incorporation by reference. (A) Illinois Pollution Control Board, Opinion and Order of the Board, PCB 84-53, Villa Grove's “Dump and Boot Pit” site-specific TSP revision. This revision extends the compliance date for control requirements on these emissions until September 1, 1987, and was adopted on July 14, 1984.

(64) On May 13, 1985, the Illinois Environmental Protection Agency (IEPA) submitted a variance from Illinois Rule 202(b) for a Brule pathological waste incinerator (BPWI) at NPWC's facility located at the Great Lakes Naval Base, Great Lakes, Shields Township, Illinois, as a revision to its TSP SIP. Shields Township is an attainment area for both the primary and secondary national ambient air quality standards (NAAQS) for TSP.

(i) Incorporation by reference. (A) Opinion and Order of the Illinois Pollution Control Board 84-156 adopted on March 22, 1985.

(65) Submitted from the Illinois Environmental Protection Agency (IEPA) dated July 22, 1985, requesting an extended compliance schedule for Precision Coatings Incorporated (PCI) coating Machine Number 2.

(i) Incorporation by reference. (A) Illinois Pollution Control Board Opinion and Order of the Board, PCB 84-117, which was adopted on February 20, 1985, and a modification to PCB 84-117 which was adopted on April 14, 1985.

(66) On March 27, 1985, the Illinois Environmental Protection Agency (IEPA) submitted a site-specific revision to its Carbon Monoxide State Implementation Plan for Anderson Clayton Foods, Inc. (ACF), a variance from 35 Illinois Administrative Code (IAC) 216.121 which governs Carbon Monoxide emissions from the Fluidized Bed Combuster retrofitted boiler at ACF's Jacksonville, Illinois facility. IAC 216.121 was incorporated in the Illinois SIP on May 31, 1972 (37 FR 10862), as Illinois Pollution Control Board Rule 206(a).

(i) Incorporation by reference. (A) Illinois Pollution Control Board Opinion and Order of the Board, PCB 84-147, which was adopted on January 24, 1985.

(67) On April 18, 1983, the State of Illinois submitted a 0.60 lb TSP/MMBTU emission limit for the City of Rochelle Municipal Steam Power Plant. On May 24, 1985, it submitted a revised modeling analysis.

(i) Incorporation by reference. Illinois Pollution Control Board Order (R78-15), Rule 203(g)(1)(C)(iii) which is dated February 24, 1983.

(68) On May 8, 1985, the Illinois Environmental Protection Agency submitted a variance until December 31, 1987, from Illinois Rule 205(n)(1)(b)(v) and Rule 205(n)(1)(b)(vi), for American Can Corporation's Hoopeston, Illinois facility in the form of a January 24, 1985, Opinion and Order of the Illinois Pollution Control Board (PCB 84-106).

(i) Incorporation by reference. (A) A January 24, 1985, Opinion and Order of the Illinois Pollution Control Board (ICPB), PCB 84-106. This is a variance until December 31, 1987, for the coating reformulation programs at American Can Corporation's Hoopeston facility located in Hoopeston, Illinois.

(69) On January 28, 1983, the Illinois Environmental Protection Agency submitted a December 30, 1982, Illinois Pollution Control Board Order (R80-5). Illinois Pollution Control Board Rules 205(l) (4) through (10), 205(t) and 205(u) are approved.

(i) Incorporation by reference. (A) Illinois Pollution Control Board Rules 205(l)(4) through (10), 205(t) and 205(u) as contained in December 30, 1982, Illinois Pollution Control Board Order R80-5.

(ii) Additional material. None.

(70) On February 13, 1986, the Illinois Environmental Protection Agency (IEPA) submitted a revision to its ozone SIP for the Fedders-USA's facility located in Effingham, Effingham County, Illinois. It grants Fedders-USA a compliance date extension for control requirements from October 1, 1982, to April 1, 1986, and provides for a legally enforceable compliance program.

(i) Incorporation by reference. (A) A January 9, 1986, Opinion and Order of the Illinois Pollution Control Board (IPCB), PCB 83-47.

(71) On October 20, 1983, the Illinois Environmental Protection Agency submitted a site-specific revision to Illinois' sulfur dioxide plan for Illinois Power Company's Baldwin Power Station. The revised SO2 emission limitations are 101,966 lbs/hour, in the aggregate, and 6 lbs/MMBTU.

(i) Incorporation by reference. (A) Emission limits within Paragraph 1 of Illinois Pollution Control Board Final Order PCB 79-7, which was adopted September 8, 1983.

(72) [Reserved]

(73) On May 6, 1985, the Illinois Environmental Protection Agency, requested an extended compliance schedule for National Can Corporation's Rockford facility.

(i) Incorporation by reference. (A) Illinois Pollution Control Board, April 1, 1982, Opinion and Order of the Board, PCB 81-189 and a January 24, 1985, Opinion and Order PCB 84-108. These orders grant National Can Corporation (Rockford Plant) a variance from the existing VOC SIP requirements from December 31, 1982, until December 31, 1983, and from December 31, 1983, until December 31, 1985, respectively.

(74) On October 30, 1986, the Illinois Environmental Protection Agency submitted a September 25, 1986, Final Order of the Illinois Pollution Control Board R85-33 revises the State's coke oven pushing and charging rules and recodifies some related rules.

(i) Incorporation by reference. (A) Order of the Illinois Pollution Control Board R85-33, which was adopted September 25, 1986.

(75)-(77) [Reserved]

(78) On January 28, 1983, June 25, 1987, August 21, 1987, September 28, 1987, October 2, 1987, December 22, 1987, January 8, 1988, March 29, 1988, and May 2, 1988 the State submitted stationary source control measures for incorporation in the ozone plan.

(i) Incorporation by reference. (A) The following sections of title 35, Environmental Protection; subtitle B: Air Pollution; Chapter 1: Pollution Control Board of the Illinois Administrative Code, (June 1989): section 211.122 (definitions of bead-dipping; component; dry cleaning facility; external floating roof; gas service; green tire spraying; green tires; heavy liquid; liquid mounted seal; liquid service; pneumatic rubber tire manufacture; refinery unit, process unit, or unit; tread end cementing; undertread cementing; valves not externally regulated; vapor collection system; vapor mounted primary seal; volatile organic liquid; and volatile organic material) of subpart B (part 211); section 215.104 (definitions of continuous process; in vacuum service; material recovery section; open-ended valve; polystyrene plant; polystyrene resin; repaired; styrene devolatilizer unit; and styrene recovery unit) of subpart A (part 215); sections 215.124, 215.125, and 215.126 of subpart B (part 215); section 215.205 of subpart F (part 215); sections 215.240, 215.241, and 215.249 of subpart H (part 215); section 215.408 of subpart P (part 215); sections 215.420 through 215.431, 215.433, 215.434, 215.435, 215.437, and 215.438, all of subpart Q (part 215); section 215.453 of subpart R (part 215); sections 215.465 and 215.466 of subpart S (part 215); sections 215.520, 215.521, 215.525, 215.526, and 215.527 all of subpart V (part 215); sections 215.582, 215,583, and 215.584 of subpart Y (part 215); sections 215.607 through 215.613 of subpart Z (part 215); and sections 215.875, 215.877, 215.879, 215.881, 215.883, and 215.886 all of subpart BB (part 215) are approved.

(ii) Additional material. (79) On March 20, 1986, November 17, 1986, and July 1, 1987, Illinois submitted its vehicle inspection and maintenance plan for the Chicago and East St. Louis areas.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter II: Environmental Protection Agency, Part 276, Procedures To Be Followed in the Performance of Annual Inspections of Motor Vehicle Exhaust Emissions, Adopted at 10 Illinois Register 13954, effective August 13, 1986.

(ii) Additional material. (A) “Technical Procedures Memorandum—Enforcement” between the Illinois Secretary of State and the Illinois Environmental Protection Agency, as submitted by Michael J. Hayes, Manager, Division of Air Pollution Control on July 1, 1987.

(80) [Reserved]

(81) On April 6, 1990, and May 4, 1990, Illinois submitted a regulation which reduced the maximum allowable volatility for gasoline sold in Illinois during July and August 1990 to 9.5 pounds per square inch.

(i) Incorporation by reference. (A) Title 35: Environmental protection, Subtitle B: Air pollution, Chapter I: Pollution control board, Part 215, Organic material emission standards and limitations, § 215.585, Gasoline volatility standards, Adopted at 14 Illinois register 6434, effective April 11, 1990.

(82)-(83) [Reserved]

(84) On September 18, 1991, and November 18, 1991, the State submitted documents intended to satisfy federal requirements for an operating permit program which can issue federally enforceable operating permits.

(i) Incorporation in reference. (A) Public Act 87-555, an Act to amend the Environmental Protection Act by changing section 9.1, effective September 17, 1991. (Ch. 111 1/2, par. 1009.1) par. 1009.1(a), (b), (c), (d) and (f).

(85) On March 24, 1988, the State submitted rules for issuance of construction permits to new and modified air pollution sources located in or affecting nonattainment areas (New Source Review rules).

(i) Incorporation by reference. (A) Illinois Administrative Code, Title 35 Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Part 203: Major Stationary Sources.

(86) On February 8, 1991, the State submitted revisions to its sulfur dioxide measurement methodology.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Part 214 Sulfur Limitations, Subpart A: General Provisions, section 214.101 Measurement Methods. Adopted December 20, 1990, effective January 15, 1991.

(87) On March 13, 1985, the State submitted revisions to its sulfur dioxide limitations.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Part 214 Sulfur Limitations, Subpart C: Existing Solid Fuel Combustion Emission Sources, Section 214.141 Sources Located in Metropolitan Areas, through paragraph (a) only, effective March 28, 1983; Subpart F: Alternative Standards for Sources Inside Metropolitan Areas, Section 214.201 Alternative Standards for Sources in Metropolitan Areas and Section 214.202 Dispersion Enhancement Techniques, effective March 28, 1983.

(88) On June 9, 1986, the State submitted revisions to its sulfur dioxide limitations in the form of a April 24, 1986, opinion and order of the Illinois Pollution Board in proceeding R84-28.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution Chapter 1: Pollution Control Board Part 214 Sulfur Limitations, Subpart C: Existing Solid Fuel Combustion Emission Sources, § 214.141 Sources Located in Metropolitan Areas, paragraphs b), c) and d), and Subpart X: Utilities, § 214.560 Scope and § 214.561 E.D. Edwards Electric Generating Station effective May 20, 1986.

(89) On March 17, 1989, and August 28, 1990, the State of Illinois submitted a revision to the Illinois State Implementation Plan. The revision is contained in subpart J, § 201.281 and subpart L, §§ 201.401-.408 of part 210 of title 35 of the Illinois Administrative Code. This revision provides a legally enforceable procedure for continuously monitoring and recording emissions to determine the status of compliance of certain stationary source categories and complies with 40 CFR 51.214 and part 51, appendix P. The rules were adopted by the Illinois Pollution Control Board on December 15, 1988, published (13 Ill. Reg. 2066) and became effective February 3, 1989. The rules were corrected for an omission, published on November 15, 1989, (13 Ill Reg. 19444), and became effective December 5, 1989. In a November 18, 1991, letter from Bharat Mathur, then Manager, Division of Air Pollution Control, Illinois Environmental Protection Agency (IEPA) to Stephen Rothblatt, Chief, Regulation Development Branch, Region 5, USEPA, Illinois committed to notify USEPA of any pending construction or operating permit application during the 30 day public comment period which is part of Illinois' permit issuance process (Section 203.150). This commitment is part of the administrative record of USEPA's approval of the Illinois' operating permit program for the purpose of issuing federally enforceable operating permits at 40 CFR 52.720 (c) (84) and 52.737 on December 17, 1992 (57 FR 59928). USEPA may deem a permit not federally enforceable if monitoring provisions do not comply with the requirements of 40 CFR 51.214, part 51, appendix P or § 51.165.

(i) Incorporation by reference. (A) Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter a: Permits and General Provisions; Part 201: Permits and General Provisions, Subpart J: Monitoring and Testing, Section 201.281; and Subpart L: Continuous Monitoring, Sections 201.401 through 201.408, adopted at Ill. Reg. 2066, effective February 3, 1989.

(90) On June 11, 1991, Illinois submitted regulations concerning the emission of volatile organic compounds from pharmaceutical manufacturing.

(i) Incorporation by reference. (A) Title 35 of the Illinois Administrative Code: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter C: Emissions Standards and Limitations for Stationary Sources, Part 215: Organic Material Emission Standards and Limitations, Subpart T: Pharmaceutical Manufacturing, Subpart A: General Provisions: Amendments to sections 215.102 and 215.105 and Creation of section 215.108. Adopted at 15 Illinois Register 80 18, effective May 14, 1991.

(B) Title 35 of the Illinois Administrative Code: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter C: Emissions Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions. Adopted at 15 Illinois Register 79 01, effective May 14, 1991.

(91) [Reserved]

(92) On June 4, 1992, the State submitted particulate matter regulations adopted as part of Pollution Control Board Proceeding R91-35. These regulations concern particulate matter ambient limits and episode regulations.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board

(A) Part 212 Visible and Particulate Matter Emissions: Section 212.113 Incorporations by Reference; section 212.424 Fugitive Particulate Matter Control for the Portland Cement Manufacturing Plant and Associated Quarry Operations located in LaSalle County, South of the Illinois River; section 212.443 Coke Plants; section 212.445 Blast Furnace Cast Houses; adopted at 16 Illinois Register 8204, effective May 15, 1992.

(B) Part 243 Air Quality Standards: Section 243.108 Incorporations by Reference; section 243.120 PM−10; section 243.121 Repealed; adopted at 16 Illinois Register 8185, effective May 15, 1992.

(C) Part 244 Episodes: Section 244.101 Definitions; section 244.106 Monitoring; section 244.107 Determination of Areas Affected; section 244.121 Local Agency Responsibilities; section 244.161 Advisory Alert and Emergency Levels; section 244.162 Criteria for Declaring and Advisory; section 244.163 Criteria for Declaring a Yellow Alert; section 244.166 Criteria for Terminating Advisory, Alert and Emergency; section 244.167 Episode Stage Notification; section 244.168 Contents of Episode Stage Notification; section 244.169 Actions During Episode Stages Adopted; section 244 appendix D; adopted at 16 Illinois Register 8191, effective May 15, 1992.

(93) On September 30, 1992, the State submitted rules regulating volatile organic compound emissions from gasoline dispensing facilities' motor vehicle fuel operations.

(i) Incorporation by reference. (A) Illinois Administrative Code, title 35 Environmental Protection, subtitle B: Air Pollution, chapter I: Pollution Control Board part 218: Organic Material Emission Standards and Limitations for the Chicago Area; subpart Y: Gasoline Distribution; § 218.583 Gasoline Dispensing Facilities—Storage Tank Filling Operations, amended at 16 Illinois Register 13864 effective August 24, 1992, and; § 218.586 Gasoline Dispensing Facilities—Motor Vehicle Fueling Operations, added at 16 Illinois Register 13864, effective August 24, 1992.

(B) [Reserved]

(ii) Additional materials. (A) Stage II Vapor Recovery SIP Program Description dated September 29, 1992.

(94) On July 30, 1986, the State submitted particulate boiler rules intended to replace rule 203(g)(1) which was vacated by the Courts. No action is taken on § 212.209 because the variance which it authorized has expired. On July 22, 1988, the State submitted opacity rules intended to replace rule 202(b) which had been vacated by the Courts. Also on July 22, 1988, the State submitted Illinois Pollution Control Board procedural rules for considering Air Adjusted Standard Procedures.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Illinois Administrative Code, Subtitle B: Air Pollution; Chapter 1: Pollution Control Board; part 212 Visible and Particulate Matter Emissions; subpart E: Particulate Matter Emission from Fuel Combustion Emission Sources; §§ 212.201, 212.202, 212.203 and 212.204. Amended or added at 10 Ill Reg. 12637, effective July 9, 1986.

(B) Title 35: Environmental Protection, Illinois Administrative Code, Subtitle B: Air Pollution; Chapter 1: Pollution Control Board; part 212 Visible and Particulate Matter Emissions; subpart B: Visible Emissions. Amended or added at 12 Ill. Reg 12492, effective July 13, 1988.

(C) Title 35: Environmental Protection, Illinois Administrative Code; Subtitle A: General Provisions; Chapter 1: Pollution Control Board; part 106: Hearings Pursuant to Specific Rules; subpart E: Air Adjusted Standards Procedures. Added at 12 Ill. Reg 12484, effective July 13, 1988.

(95) On October 16, 1991, and November 13, 1991, the State submitted particulate matter regulations adopted as part of Pollution Control Board Proceeding R91-6. These regulations concern particulate matter controls for LaSalle County, Illinois.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board.

(A) The addition of definitions for “Condensible PM-10”, “PM-10”, “Portland Cement Manufacturing Process Emission Source”, and the modification of the definition of “Portland Cement Process” to Part 211 Definitions and General Provisions: Section 211.122 Definitions; adopted at 15 Illinois Register 15673, effective October 14, 1991.

(B) Part 212 Visible and Particulate Matter Emissions: Section 212.110 Measurement Methods; the addition of an abbreviation for pounds per hour to Section 212.111 Abbreviations and Units; additions and deletions to Section 212.113 Incorporations by Reference including the addition and/or renumbering of paragraphs (a), (b), (c), (d), (e), and (h) and the deletion of paragraphs earlier numbered as (a) and (f); Section 212.423 Emission Limits for Portland Cement the Manufacturing Plant Located in LaSalle County, South of the Illinois River; adopted at 15 Illinois Register 15708, effective October 4, 1991.

(96) On November 12, 1992, the State of Illinois submitted a Small Business Stationary Source Technical and Environmental Assistance Program for incorporation in the Illinois State Implementation Plan as required by section 507 of the Clean Air Act Amendments of 1990. Included in the State's submittal were a program description, newly adopted enabling legislation including new subsection 20 of section 39.5 of the Environmental Protection Act, Public Act 87-1213, and new subsection 46.13(a) of the Civil Administrative Code, Public Act 87-1177, and a May 4, 1992, State of Illinois, Illinois Department of Commerce and Community Affairs (DCCA), Illinois Environmental Protection Agency (IEPA) Interagency Agreement defining the responsibilities of DCCA and IEPA in developing and implementing the Small Business Stationary Source Technical and Environmental Compliance Assistance Program (Program).

(i) Incorporation by reference. (A) Subsection 20 of section 39.5 of the Environmental Protection Act adopted as Public Act 87-1213 signed into law on September 26, 1992, and effective upon signature.

(B) Subsection 46.13(a) of the Civil Administrative Code adopted as Public Act 87-1177 signed into law on September 21, 1992, and effective upon signature.

(ii) Other material. (A) Program description.

(B) May 4, 1992, Interagency Agreement between DCCA and IEPA defining the responsibilities of each agency in developing and implementing the program.

(97) On October 12, 1992, and June 2, 1993, the State of Illinois submitted a requested revision to the Illinois State Implementation Plan (SIP) intended to satisfy the requirements of section 182(a)(3)(B) of the Clean Air Act as amended in 1990. Included were State rules establishing procedures for the annual reporting of emissions of volatile organic material (VOM) and oxides of nitrogen (NOX) as well as other regulated air pollutants by stationary sources in ozone nonattainment areas. Also included was a June 2, 1993, commitment letter from the Illinois Environmental Protection Agency (IEPA) to fulfill the reporting requirements of the United States Environmental Protection Agency by performing the following tasks:

(i) Update the AIRS Facility Subsystem using the annual emissions report data. The 1992 data will be updated by December 31, 1993, and subsequent updates will be made by July 1st of each year.

(ii) Retain annual emissions reports for at least three (3) years.

(iii) Develop and submit Emissions Statement Status Reports (ESSR) on a quarterly basis each year until all applicable sources have submitted the required annual emissions reports. The report will show the total number of facilities from which emission statement data was requested, the number of facilities that met the provisions, and the number of facilities that failed to meet the provisions. Sources that are delinquent in submitting their emissions statements will be individually listed if they emit 500 tons per year or more of VOM or 2500 tons per year or more of NOX. The report will also contain the emission data requested in Appendix F of the July 6, 1992, Draft Guidance on the Implementation of an Emission Statement Program.

(iv) All sources subject to the emission statement requirements must report, at a minimum, the information specified under subpart C of part 254 of chapter II of subtitle B of title 35 of the Illinois Administrative Code.

(A) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter II: Environmental Protection Agency, Part 254: Annual Emissions Report, adopted at 17 Illinois Register 7782, effective May 14, 1993.

(B) Other material. June 2, 1993, commitment letter.

(98) On July 21, 1986, the State a submitted revision to its particulate matter regulations to incorporate an emission limit for continuous automatic stoking animal pathological waste incinerators.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Part 212 Visible and Particulate Matter Emissions, subpart D: Particulate Matter Emissions from Incinerators, section 212.185 Continuous Automatic Stoking Animal Pathological Waste Incinerators. Adopted December 18, 1986, added at 11 Ill. Reg. 1410, effective December 30, 1986.

(99) On January 4, 1989, the State submitted revisions to its sulfur dioxide rules.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 214 Sulfur Limitations, Subpart A: General Provisions, section 214.102 Abbreviations and Units. Amended at 12 Ill. Reg. 20778, effective December 5, 1988.

(B) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 214 Sulfur Limitations, Subpart A: General Provisions, section 214.104 Incorporations by Reference. Amended at 15 Ill. Reg. 1017, effective January 15, 1991.

(C) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 214 Sulfur Limitations, Subpart O: Petroleum Refining, Petrochemical and Chemical Manufacturing, section 214.382 Petroleum and Petrochemical Processes. Amended at 12 Ill. Reg. 20778, effective December 5, 1988.

(100) On October 21, 1993, the State submitted definitions codified as part of the Illinois Administrative Code for incorporation in the Illinois State Implementation Plan.

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211 Definitions and General Provisions, Subpart A: General Provisions: Sections 211.101 and 211.102, Subpart B: Definitions, Sections 211.121, 211.130, 211.150, 211.170, 211.210, 211.230, 211.250, 211.290, 211.310, 211.330, 211.350, 211.370, 211.390, 211.410, 211.430, 211.450, 211.470, 211.490, 211.510, 211.530, 211.550, 211.570, 211.590, 211.610, 211.630, 211.650, 211.670, 211.690, 211.710, 211.730, 211.750, 211.770, 211.790, 211.810, 211.830, 211.850, 211.870, 211.890, 211.910, 211.930, 211.950, 211.970, 211.990, 211.1010, 211.1050, 211.1090, 211.1110, 211.1130, 211.1150, 211.1170, 211.1190, 211.1210, 211.1230, 211.1250, 211.1270, 211.1290, 211.1310, 211.1330, 211.1350, 211.1370, 211.1390, 211.1410, 211.1430, 211.1470, 211.1490, 211.1510, 211.1530, 211.1550, 211.1570, 211.1590, 211.1610, 211.1630, 211.1650, 211.1670, 211.1690, 211.1710, 211.1730, 211.1750, 211.1770, 211.1790, 211.1810, 211.1830, 211.1850, 211.1870, 211.1890, 211.1910, 211.1930, 211.1950, 211.1970, 211.1990, 211.2010, 211.2050, 211.2070, 211.2090, 211.2110, 211.2130, 211.2150, 211.2170, 211.2190, 211.2210, 211.2230, 211.2250, 211.2270, 211.2310, 211.2330, 211.2350, 211.2370, 211.2390, 211.2410, 211.2430, 211.2450, 211.2470, 211.2490, 211.2510, 211.2530, 211.2550, 211.2570, 211.2590, 211.2650, 211.2670, 211.2690, 211.2710, 211.2730, 211.2750, 211.2770, 211.2790, 211.2810, 211.2830, 211.2850, 211.2870, 211.2890, 211.2910, 211.2930, 211.2950, 211.2970, 211.2990, 211.3010, 211.3030, 211.3050, 211.3070, 211.3090, 211.3110, 211.3130, 211.3150, 211.3170, 211.3190, 211.3210, 211.3230, 211.3250, 211.3270, 211.3290, 211.3310, 211.3330, 211.3350, 211.3370, 211.3390, 211.3410, 211.3430, 211.3450, 211.3470, 211.3490, 211.3510, 211.3530, 211.3550, 211.3570, 211.3590, 211.3610, 211.3630, 211.3650, 211.3670, 211.3690, 211.3710, 211.3730, 211.3750, 211.3770, 211.3790, 211.3810, 211.3830, 211.3850, 211.3870, 211.3890, 211.3910, 211.3930, 211.3970, 211.3990, 211.4010, 211.4030, 211.4050, 211.4070, 211.4090, 211.4110, 211.4130, 211.4150, 211.4170, 211.4190, 211.4210, 211.4230, 211.4250, 211.4270, 211.4290, 211.4310, 211.4330, 211.4350, 211.4370, 211.4390, 211.4410, 211.4430, 211.4450, 211.4470, 211.4490, 211.4510, 211.4530, 211.4550, 211.4590, 211.4610, 211.4630, 211.4650, 211.4670, 211.4690, 211.4710, 211.4730, 211.4750, 211.4770, 211.4790, 211.4810, 211.4870, 211.4890, 211.4910, 211.4930, 211.4950, 211.4990, 211.5030, 211.5050, 211.5070, 211.5090, 211.5110, 211.5130, 211.5150, 211.5170, 211.5185, 211.5190, 211.5210, 211.5230, 211.5250, 211.5270, 211.5310, 211.5330, 211.5350, 211.5370, 211.5410, 211.5430, 211.5450, 211.5470, 211.5490, 211.5510, 211.5550, 211.5570, 211.5590, 211.5610, 211.5630, 211.5650, 211.5670, 211.5690, 211.5710, 211.5730, 211.5750, 211.5770, 211.5790, 211.5810, 211.5830, 211.5850, 211.5870, 211.5890, 211.5910, 211.5930, 211.5950, 211.5970, 211.5990, 211.6010, 211.6030, 211.6050, 211.6070, 211.6090, 211.6130, 211.6150, 211.6190, 211.6210, 211.6230, 211.6270, 211.6290, 211.6310, 211.6330, 211.6350, 211.6370, 211.6390, 211.6410, 211.6430, 211.6450, 211.6470, 211.6490, 211.6510, 211.6530, 211.6550, 211.6570, 211.6590, 211.6610, 211.6670, 211.6690, 211.6730, 211.6750, 211.6770, 211.6790, 211.6810, 211.6850, 211.6870, 211.6890, 211.6910, 211.6930, 211.6950, 211.6970, 211.6990, 211.7010, 211.7030, 211.7070, 211.7090, 211.7110, 211.7130, 211.7150, 211.7170, 211.7190, 211.7210, 211.7230, 211.7250, 211.7270, 211.7290, 211.7310, 211.7330, 211.7350.

These section were added at 17 Ill. Reg. 16504, effective September 27, 1993.

(101) On October 21, 1993, the state submitted volatile organic compound (VOC) control regulations for incorporation in the Illinois State Implementation for ozone.

(i) Incorporation by reference. (A) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 218: Organic Material Emission Standards and Limitations for the Chicago Area Subparts A, B, C, E, F, G, H, Q, R, S, T, V, W, X, Y, Z, AA, BB, and Section 218.

Appendix A, B, C, and D. These regulations were adopted at R91-7 at 15 Ill. Reg. 12231, effective August 16, 1991; amended in R91-23 at Ill. Reg. 13564, effective August 24, 1992; amended in R91-28 and R91-30 at 16 Ill. Reg. 13864, effective August 24, 1992; amended in R93-9 at 17 Ill. Reg. 16636, effective September 27, 1993. The specific adoption and effective dates of the rules incorporated by reference follow.

(1) Adopted at R91-7 at 15 Ill. Reg. 12231, effective August 16, 1991. Subpart A 218.108; Subpart C: 218.142; Subpart R: 218.442, 218.444, 218.448, 218.451; Subpart T: 218.484, 218.488; Subpart V: 218.526; Subpart X: 218.561, 218.563; Subpart Z: 218.607; Subpart AA: 218.625, 218.626 and 218.630.

(2) Amended in R93-9 at 17 Ill. Reg. 16636, effective September 27, 1993. Subpart A: 218.100, 218.101, 218.102, 218.103, 218.104, 218.105, 218.106, 218.107, 218.109, 218.110, 218.111, 218.112; Subpart B: 218.121, 218.122, 218.123, 218.124; Subpart C: 218.141, 218.143, 218.144; Subpart E: 218.181, 218.182, 218.183, 218.184, 218.186; Subpart F: 218.204, 218.205, 218.206, 218.207, 218.208, 218.209, 218.210, 218.211; Subpart G: 218.301, 218.302, 218.303, 218.304; Subpart H: 218.401, 218.402, 218.403, 218.404, 218.405; Subpart Q: 218.421, 218.422, 218.423, 218.424, 218.425, 218.426, 218.427, 218.428, 218.429; Subpart R: 218.441, 218.443, 218.445, 218.446, 218.447, 218.449, 218.450, 218.452; Subpart S: 218.461, 218.462, 218.463, 218.464; Subpart T: 218.480, 218.481, 218.482, 218.483, 218.485, 218.486, 218.487, 218.489; Subpart V: 218.525; Subpart W: 218.541; Subpart X: 218.562; Subpart Y: 218.581, 218.582, 218.583, 218.584, 218.585, 218.586; Subpart Z: 218.601, 218.602, 218.603, 218.608, 218.609, 218.610, 218.611; Subpart AA: 218.620, 218.621, 218.623, 218.624, 218.628, 218.636, 218.637; Subpart BB: 218.640, 218.642, 218.644, Section 218: Appendix A, Appendix B, Appendix C, Appendix D.

(3) Section 218.585 was repealed in 2013 and is removed without replacement; see paragraph (c)(201) of this section.

(B) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 219: Organic Material Emission Standards and Limitations for Metro East Area Subparts A, B, C, E, F, G, H, Q, R, S, T, V, W, X, Y, Z, AA, BB and Section 219 Appendix A, B, C, and D. These regulations were adopted at R91-8 at Ill. Reg. 12491, effective August 16, 1991; amended in R91-24 at 16 Ill. Reg. 13597, effective August 24, 1992; amended in R91-30 at 16 Ill. Reg. 13833, effective August 24, 1992, emergency amendment in R93-12 at Ill. Reg. 8295, effective May 24, 1993, for a maximum of 150 days, amended in R93-9 at 17 Ill. Reg. 16918, effective September 27, 1993 and October 21, 1993. The specific adoption and effective dates of the rules incorporated by reference follow.

(1) Adopted at R91-8 at 15 Ill. Reg. 12491, effective August 16, 1991: Subpart A: 219.103, 219.108; Subpart C: 219.142; Subpart R: 219.442, 219.444, 219.448, 219.451; Subpart T: 219.484, 219.488; Subpart V: 219.526; Subpart X: 219.561, 219.563; Subpart Z: 219.607; Subpart AA: 219.625, 219.626, 219.630.

(2) Amended in R93-9 at 17 Ill. Reg. 16918, effective September 27, 1993:

Subpart A: 219.100, 219.101, 219.102, 219.104, 219.105, 219.106, 219.107, 219.109, 219.110, 219.111, 219.112; Subpart B: 219.121, 219.122, 219.123, 219.124; Subpart C: 219.141, 219.143, 219.144; Subpart E: 219.181, 219.182, 219.183, 219.184, 219.186; Subpart F: 219.204, 219.205, 219.206, 219.207, 219.208, 219.209, 219.210, 219.211; Subpart G: 219.301, 219.302, 219.303, 219.304; Subpart H: 219.401, 219.402, 219.403, 219.404, 219.405; Subpart Q: 219.421, 219.422, 219.423, 219.424, 219.425, 219.426, 219.427, 219.428, 219.429; Subpart R: 219.441, 219.443, 219.445, 219.446, 219.447, 219.449, 219.450, 219.452; Subpart S: 219.461, 219.462, 219.463, 219.464; Subpart T: 219.480, 219.481, 219.482, 219.483, 219.485, 219.486, 219.487, 219.489; Subpart V: 219.525; Subpart W: 219.541; Subpart X: 219.562; Subpart Y: 219.581, 219.582, 219.583, 219.584, 219.585, 219.586; Subpart Z: 219.601, 219.602, 219.603, 219.608, 219.609, 219.610, 219.611; Subpart AA: 219.620, 219.621, 219.623, 219.624, 219.628, 219.636, 219.637; Subpart BB: 219.640, 219.642, 219.644; Section 219: Appendix A, Appendix B, Appendix C, Appendix D.

(3) Section 219.585 was repealed in 2013 and is removed without replacement; see paragraph (c)(201) of this section.

(102) On October 21, 1993 and March 4, 1994, the State submitted volatile organic compound control regulations for incorporation in the Illinois State Implementation Plan for ozone.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Sections 211.270, 211.1070, 211.2030, 211.2610, 211.3950, 211.4050, 211.4830, 211.4850, 211.4970, 211.5390, 211.5530, 211.6110, 211.6170, 211.6250, 211.6630, 211.6650, 211.6710, 211.6830, 211.7050. These sections were adopted on January 6, 1994, Amended at 18 Ill. Reg. 1253, and effective January 18, 1994.

(B) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 218: Organic Material Emissions Standards and Limitations for the Chicago Area, Subpart PP: 218.927, 218.928; Subpart QQ: 218.947, 218.948; Subpart RR: 218.967, 218.968; Subpart TT: 218.987, 218.988; Subpart UU: 218.990. These sections were adopted on September 9, 1993, Amended at 17 Ill. Reg. 16636, effective September 27, 1993.

(C) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 218: Organic Material Emissions Standards and Limitations for the Chicago Area, Subpart A: 218.106, 218.108, 218.112, 218.114; Subpart H: 218.402; Subpart Z: 218.602, 218.611; Subpart AA: 218.620, 218.623 (repealed); Subpart CC; Subpart DD; Subpart PP: 218.920, 218.926; Subpart QQ: 218.940, 218.946; Subpart RR: 218.960, 218.966; Subpart TT: 218.980, 218.986; Subpart UU: 218.991. These sections were adopted on January 6, 1994, Amended at 18 Ill. Reg. 1945, effective January 24, 1994.

(103) On February 11, 1993, Illinois submitted a site specific revision to its carbon monoxide State Implementation Plan for a General Motors Corporation iron foundry located adjacent to Interstate 74 at G Street in Vermilion County, Illinois.

(i) Incorporation by reference. (A) Illinois Administrative Code; Title 35 Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter C: Emission Standards and Limitations for Stationary Sources; P 216: Carbon Monoxide Emissions; Subpart O: Primary and Fabricated Metal Products; Section 216.382 Exception, General Motors Ferris Foundry in Vermilion County. Added at 16 Illinois Register 18075, effective November 13, 1992.

(104) [Reserved]

(105) On February 7, 1994, the State submitted revisions intended to create a permit program for small sources. The purpose of these revisions is to lessen the permitting burden on small sources and the permitting authority by reducing the frequency and/or the requirement of operating permit renewal for sources emitting a total of less than 25 tons per year of regulated air pollutants. A permit obtained through these procedures is intended to continue as a legally binding State document until the source modifies its operations, withdraws its permit or becomes subject to a new applicable requirement. At that time, the State will determine whether the small source procedures continue to be appropriate and issue a revised small source permit or direct the source in following the correct permit procedures. Since small source permits are not subject to a public comment period or review by USEPA, they are not federally enforceable and cannot be used to limit sources' potential to emit and thereby exempt them from the requirements of the title v operating permit program.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board.

(A) Subchapter a: Permits and General Provisions, Part 201: Permits and General Provisions.

(1) Subpart D: Permit Applications and Review Process, Section 201.162 Duration and Section 201.163 Joint Construction and Operating Permits. Amended at 17 Ill. Reg., effective December 7, 1993.

(2) Subpart E: Special Provisions for Operating Permits for Certain Smaller Sources, Section 201.180 Applicability, Section 201.181 Expiration and Renewal and Section 201.187 Requirement for a Revised Permit Added at 17 Ill. Reg., effective December 7, 1993.

(B) Subchapter C: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.5500 Regulated Air Pollutant. Adopted at 17 Ill. Reg., effective December 7, 1993.

(106) On November 23, 1994, the State submitted amended marine vessel loading rules which consisted of revised definitions, and revisions to the Ozone Control Plan for the Chicago and Metro-East St. Louis areas.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B: Definitions, Sections 211.3480 Loading Event and 211.3660 Marine Vessel added at 18 Ill. Reg. 166769, effective October 25, 1994; Sections 211.3650 Marine Terminal, and 211.6970 Vapor Collection System, and Section 211.6990 Vapor Control System amended at 18 Ill. Reg. 16769, effective October 25, 1994.

(B) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart A; General Provisions, Sections 218.101 Savings Clause and 218.106 Compliance Dates amended at 18 Ill. Reg. 16392, effective October 25, 1994; Subpart GG: Marine Terminals, Sections 218.760 Applicability, 218.762 Control Requirements, 218.764 Compliance Certification, 218.766 Leaks, 218.768 Testing and Monitoring, and 218.770 Recordkeeping and Reporting added at 18 Ill. Reg. 16392, effective October 25, 1994; Appendix E: List of Affected Marine Terminals amended at 18 Ill. Reg. 16392, effective October 25, 1994.

(C) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Subpart A; General Provisions, Sections 219.101 Savings Clause and 219.106 Compliance Dates amended at 18 Ill. Reg. 16415, effective October 25, 1994; Subpart GG: Marine Terminals, Sections 219.760 Applicability, 219.762 Control Requirements, 219.764 Compliance Certification, 219.766 Leaks, 219.768 Testing and Monitoring, and 219.770 Recordkeeping and Reporting added at 18 Ill. Reg. 16415, effective October 25, 1994.

(D) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Appendix E: List of affected Marine Terminals amended at 20 Ill. Reg. 3848. Effective February 15, 1996.

(107) On October 25, 1994, Illinois submitted a regulation which requires gasoline dispensing operations in the Chicago and Metro-East St. Louis ozone nonattainment areas that have storage tanks of at least 575 gallons to install pressure/vacuum relief valves on storage tank vent pipes. Tanks installed before January 1, 1979, are exempt from the rule if they have a capacity of less than 2000 gallons, as are tanks that are equipped with floating roofs or equivalent control devices that have been approved by the State and USEPA.

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 201 Permits and General Provisions, Section 201.302 Reports. Amended at 18 Ill. Reg. 15002. Effective September 21, 1994.

(B) Part 211 Definitions and General Provisions, Section 211.5060 Pressure/Vacuum Relief Valve. Added at 18 Ill. Reg. 14962. Effective September 21, 1994.

(C) Part 218 Organic Material Emission Standards and Limitations for Chicago Area, Section 218.583 Gasoline Dispensing Operations-Storage Tank Filling Operations. Amended at 18 Ill. Reg. 14973. Effective September 21, 1994.

(D) Part 219 Organic Material Emission Standards and Limitations for Metro East Area, Section 219.583 Gasoline Dispensing Operations-Storage Tank Filling Operations. Amended at 18 Ill. Reg. 14987. Effective September 21, 1994.

(108) On January 25, 1994, the State submitted a revision to its ozone State Implementation Plan (SIP) for Quantum Chemical Corporation's facility located in Morris, Aux Sable Township, Grundy County, Illinois. It grants an adjusted standard from Parts 35 Illinois Administration Code (IAC) 218.966 and 218.986 as they apply to specific units or plants within this facility.

(i) Incorporation by reference. (A) Illinois Pollution Control Board Final Opinion and Order, AS 92-14, adopted on October 7, 1993, and effective on October 7, 1993.

(109) On October 25, 1994, Illinois submitted a regulation that reduces the maximum allowable volatility for gasoline sold in the Metro-East St. Louis ozone nonattainment area, which includes Madison, Monroe, and St. Clair Counties, to 7.2 pounds per square inch Reid Vapor Pressure (RVP) during the summer control period. On May 14, 1996, Illinois submitted an amendment to its RVP rule which changes the summer regulatory control period of the program. The summer control period for the Illinois RVP program is June 1 to September 15.

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 219 Organic Material Emission Standards and Limitations for Metro East Area.

(A) Section 219.112 Incorporation by Reference. Amended at 18 Ill. Reg. 14987. Effective September 21, 1994.

(B) [Reserved]

(C) Section 219.585 Gasoline Volatility Standards. Amended at 20 Ill. Reg. 3848: Effective February 15, 1996.

(D) Section 219.585 was repealed in 2013 and is removed without replacement; see paragraph (c)(201) of this section.

(110) On September 26, 1994, the State of Illinois submitted a revision to its ozone State Implementation Plan for the J. M. Sweeney Company located in Cicero, Cook County, Illinois. It grants a compliance date extension from Stage II vapor control requirements (35 Ill. Adm. Code 218.586) from November 1, 1993, to March 31, 1995.

(i) Incorporation by reference. (A) Illinois Pollution Control Board Final Opinion and Order, PCB 93-257, adopted on September 1, 1994, and effective on September 1, 1994. Certification dated 9/23/94 of Acceptance by J. M. Sweeney.

(111) On July 29, 1994, Illinois submitted regulations which require adoption and implementation of particulate matter contingency measures for Illinois' four moderate particulate matter nonattainment areas. Sources in the nonattainment areas which emit at least 15 tons of particulate matter must submit two levels of contingency measures, which will then become Federally enforceable. Sources will be required to implement the contingency measures if an exceedance of the National Ambient Air Quality Standard for Particulate Matter is measured, or if the United States Environmental Protection Agency finds that an area has failed to attain the National Ambient Air Quality Standards.

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board;

(A) Part 106 Hearings Pursuant to Specific Rules, Section 106.930—Applicability, Section 106.931—Petition for Review, Section 106.932—Response and Reply, Section 106.933—Notice and Hearing, Section 106.934—Opinion and Order. Amended at 18 Ill. Reg. 11579-11586. Effective July 11, 1994.

(B) Part 212 Visible and Particulate Matter Emissions, Section 212.700—Applicability, Section 212.701—Contingency Measure Plans, Submittal and Compliance Date, Section 212.702—Determination of Contributing Sources, Section 212.703—Contingency Measure Plan Elements, Section 212.704—Implementation, Section 212.705—Alternative Implementation. Added at 18 Ill. Reg. 11587-11606. Effective July 11, 1994.

(112) On March 28, 1995, the State of Illinois submitted a revision to its ozone State Implementation Plan for P & S, Incorporated's facility located in Wood Dale, Du Page County, Illinois. It grants a compliance date extension from Stage II vapor control requirements (35 Ill. Adm. Code 218.586) from November 1, 1994 until April 1, 1996, or 60 days after notification to P & S, Incorporated that the roadway construction complicating the installation of Stage II equipment will be abandoned for any reason, whichever is sooner.

(i) Incorporation by reference. (A) Illinois Pollution Control Board Final Opinion and Order, PCB 94-299, adopted on February 16, 1995, and effective on February 16, 1995. Certification dated March 1, 1995 of Acceptance by P & S, Incorporated.

(113) On April 27, 1995, the Illinois Environmental Protection Agency requested a revision to the Illinois State Implementation Plan in the form of revisions to the State's New Source Review rules for sources in the Chicago and metropolitan East St. Louis ozone nonattainment areas and are intended to satisfy Federal requirements of the Clean Air Act as amended in 1990. The State's New Source Review provisions are codified at Title 35: Environmental Protection Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter a: Permits and General Provisions. Part 203 Major Stationary Sources Construction and Modification is amended as follows:

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subpart A: General Provisions, Section 203.101 Definitions, Section 203.107 Allowable Emissions, Section 203.110 Available Growth Margin, Section 203.112 Building, Structure and Facility, Section 203.121 Emission Offset, Section 203.122 Emissions Unit, Section 203.123 federally Enforceable, Section 203.126 Lowest Achievable Emission Rate, Section 203.128 Potential to Emit, Section 203.145 Volatile Organic Material, Section 203.150 Public Participation. Effective April 30, 1993.

(B) Title 35: Environmental Protection, Subpart B: Major Stationary Sources in Nonattainment Areas, Section 203.201 Prohibition, Section 203.203 Construction Permit Requirement and Application, Section 203.206 Major Stationary Source, Section 203.207 Major Modification of a Source, Section 203.208 Net Emission Determination, Section 203.209 Significant Emissions Determination. Effective April 30, 1993.

(C) Title 35: Environmental Protection, Subpart C: Requirements for Major Stationary Sources in Nonattainment Areas, Section 203.301 Lowest Achievable Emission Rate, Section 203.302 Maintenance of Reasonable Further Progress and Emission Offsets, Section 203.303 Baseline and Emission Offsets Determination, Section 203.306 Analysis of Alternatives. Effective April 30, 1993.

(D) Title 35: Environmental Protection, Subpart H: Offsets for Emission Increases From Rocket Engines and Motor Firing, Section 203.801 Offsetting by Alternative or Innovative Means. Effective April 30, 1993. Published in the Illinois Register, Volume 17, Issue 20, May 14, 1993.

(114) On November 30, 1994, the State submitted an amended Synthetic Organic Chemical Manufacturing Industry Air Oxidation Process rule which consisted of extended applicability and tightened control measures to the Ozone Control Plan for the Chicago and Metro-East St. Louis areas.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart V; Air Oxidation Processes, Sections 218.520 Emission Limitations for Air Oxidation Processes, 218.522 Savings Clause, 218.523 Compliance, 218.524 Determination of Applicability, and 218.525 Emission Limitations for Air Oxidation Processes (Renumbered) at 18 Ill. Reg. 16972, effective November 15, 1994.

(B) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Subpart V; Air Oxidation Processes, Sections 219.520 Emission Limitations for Air Oxidation Processes, 219.522 Savings Clause, 219.523 Compliance, 219.524 Determination of Applicability, and 219.525 Emission Limitations for Air Oxidation Processes (Renumbered) at 18 Ill. Reg. 17001, effective November 15, 1994.

(115) On May 5, 1995, and May 26, 1995, the State submitted an amended coating rule which consisted of a tightened applicability cut-off level for wood furniture coating operations to the Ozone Control Plan for the Chicago and Metro-East St. Louis areas.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart F; Coating Operations, Sections 218.208 Exemptions from Emission Limitations, Subsection (b), amended at 19 Ill. Reg. 6848, effective May 9, 1995.

(B) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Subpart F; Coating Operations, Section 219.208 Exemptions from Emission Limitations, Subsection (b), amended at 19 Ill. Reg. 6958, effective May 9, 1995.

(116) On May 5, 1995, and May 26, 1995, the State submitted a rule for automotive/transportation and business machine plastic parts coating operations, which consisted of new volatile organic compound emission limitations to the Ozone Control Plan for the Chicago and Metro-East St. Louis areas.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B; Definitions, Sections 211.660 Automotive/Transportation Plastic Parts, 211.670 Baked Coatings, 211.820 Business Machine Plastic Parts, 211.1880 Electromagnetic Interference/Radio Frequency Interference Shielding Coatings, 211.1900 Electrostatic Prep Coat, 211.2360 Flexible Coatings, 211.2630 Gloss Reducers, 211.4055 Non-Flexible Coating, 211.4740 Plastic Part, 211.5480 Reflective Argent Coating, 211.5600 Resist Coat, 211.6060 Soft Coat, 211.6140 Specialty Coatings, 211.6400 Stencil Coat, 211.6580 Texture Coat, and 211.6880 Vacuum Metallizing, amended at 19 Ill. 6823, effective May 9, 1995.

(B) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart F; Coating Operations, Sections 218.204 Emission Limitations, Subsection (n) Plastic Parts Coating: Automotive/Transportation and (o) Plastic Parts Coating: Business Machine, 218.205 Daily-Weighted Average Limitations, Subsection (g), and 218.207 Alternative Emission Limitations, Subsection (i), amended at 19 Ill. 6848, effective May 9, 1995.

(C) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Subpart F; Coating Operations, Section 219.204 Emission Limitations, Subsection (m) Plastic Parts Coating: Automotive/Transportation and (n) Plastic Parts Coating: Business Machine, 219.205 Daily-Weighted Average Limitations, Subsection (f), and 219.207 Alternative Emission Limitations, Subsection (h), amended at 19 Ill. Reg. 6958, effective May 9, 1995.

(117) On May 31, 1995, the State submitted amended lithographic printing rules which consisted of revised definitions, and revisions to the Ozone Control Plan for the Chicago and Metro-East St. Louis areas.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B: Definitions, Sections 211.474 Alcohol, 211.560 As-Applied Fountain Solution, 211.2850 Heatset Web Offset Lithographic Printing Line, 211.4065 Non-Heatset, 211.5980 Sheet-Fed added at 19 Ill. Reg. 6823, effective May 9, 1995.

(B) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart H; Printing and Publishing, Sections 218.405 Lithographic Printing: Applicability, 218.406 Provisions Applying to Heatset Web Offset Lithographic Printing Prior to March 15, 1996, 218.407 Emissions Limitations and Control Requirements for Lithographic Printing Lines On and After March 15, 1996, 218.408 Compliance Schedule for Lithographic Printing on and After March 15, 1996, 218.409 Testing for Lithographic Printing On and After March 15, 1996, 218.410 Monitoring Requirements for Lithographic Printing, 218.411 Recordkeeping and Reporting for Lithographic Printing added at 19 Ill. Reg. 6848, effective May 9, 1995.

(C) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Subpart H; Printing and Publishing, Sections 219.405 Lithographic Printing: Applicability, 219.406 Provisions Applying to Heatset Web Offset Lithographic Printing Prior to March 15, 1996, 219.407 Emissions Limitations and Control Requirements for Lithographic Printing Lines On and After March 15, 1996, 219.408 Compliance Schedule for Lithographic Printing on and After March 15, 1996, 219.409 Testing for Lithographic Printing On and After March 15, 1996, 219.410 Monitoring Requirements for Lithographic Printing, 219.411 Recordkeeping and Reporting for Lithographic Printing added at 19 Ill. Reg. 6848, effective May 9, 1995.

(118) On October 24, 1994, the State submitted a site-specific revision to the State Implementation Plan establishing lubricant selection and temperature control requirements for Alumax Incorporated, Morris, Illinois facility's hot and cold aluminum rolling mills, as part of the Ozone Control Plan for the Chicago area.

(i) Incorporation by reference. September 1, 1994, Opinion and Order of the Illinois Pollution Control Board AS 92-13, effective September 1, 1994.

(119) On May 5, 1995, and May 26, 1995, the State submitted a revised rule tightening volatile organic compound emission limitations for certain surface coating operations in the Chicago and Metro-East St. Louis areas.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart F; Coating Operations, Sections 218.204 Emission Limitations, 218.205 Daily-Weighted Average Limitations, 218.207 Alternative Emission Limitations, 218.208 Exemptions From Emission Limitations, 218.210 Compliance Schedule, 218.212 Cross-line Averaging to Establish Compliance for Coating Lines, 218.213 Recordkeeping and Reporting for Cross-line Averaging Participating Coating Lines, 218.214 Changing Compliance Methods, 218 Appendix H Baseline VOM Content Limitations for Subpart F, Section 218.212 Cross-Line Averaging, amended at 19 Ill. 6848, effective May 9, 1995.

(B) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Subpart F; Coating Operations, Sections 219.204 Emission Limitations, 219.205 Daily-Weighted Average Limitations, 219.207 Alternative Emission Limitations, 219.208 Exemptions From Emission Limitations, 219.210 Compliance Schedule, 219.212 Cross-line Averaging to Establish Compliance for Coating Lines, 219.213 Recordkeeping and Reporting for Cross-line Averaging Participating Coating Lines, 219.214 Changing Compliance Methods, 219 Appendix H Baseline VOM Content Limitations for Subpart F, Section 219.212 Cross-line Averaging, amended at 19 Ill. Reg. 6958, effective May 9, 1995.

(120) On May 5, 1995, and May 31, 1995, the State of Illinois submitted a rule for motor vehicle refinishing operations, which consisted of new volatile organic material (VOM) emission limitations to the Ozone Control Plan for the Chicago and Metro East St. Louis areas. This State Implementation Plan revision contains rules which establish VOM content limits for certain coatings and surface preparation products used in automobile and mobile equipment refinishing operations in the Chicago and Metro-East area, as well as requires these operations to meet certain equipment and work practice standards to further reduce VOM.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B; Definitions, Sections 211.240 Adhesion Promoter, 211.495 Anti-Glare/Safety Coating, 211.685 Basecoat/Clearcoat System, 211.1875 Elastomeric Materials, 211.3915 Mobile Equipment, 211.3960 Motor Vehicles, 211.3965 Motor Vehicle Refinishing, 211.5010 Precoat, 211.5061 Pretreatment Wash Primer, 211.5080 Primer Sealer, 211.5090 Primer Surfacer Coat, 211.6145 Specialty Coatings for Motor Vehicles, 211.6540 Surface Preparation Materials, 211.6620 Three or Four Stage Coating System, 211.6695 Topcoat System, 211.6720 Touch-Up Coating, 211.6860 Uniform Finish Blender, amended at 19 Ill. 6823, effective May 9, 1995.

(B) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart HH; Motor Vehicle Refinishing, Sections 218.780 Emission Limitations, 218.782 Alternative Control Requirements, 218.784 Equipment Specifications, 218.786 Surface Preparation Materials, 218.787 Work Practices, 218.788 Testing, 218.789 Monitoring and Record keeping for Control Devices, 218.790 General Record keeping and Reporting, 218.791 Compliance Date, 218.792 Registration, amended at 19 Ill. 6848, effective May 9, 1995.

(C) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Subpart HH; Motor Vehicle Refinishing, Sections 219.780 Emission Limitations, 219.782 Alternative Control Requirements, 219.784 Equipment Specifications, 219.786 Surface Preparation Materials, 219.787 Work Practices, 219.788 Testing, 219.789 Monitoring and Record keeping for Control Devices, 219.790 General Record keeping and Reporting, 219.791 Compliance Date 219.792 Registration, amended at 19 Ill. Reg. 6958, effective May 9, 1995.

(D) Sections 218.792 and 219.792 were repealed in 2013 and are removed without replacement; see paragraph (c)(201) of this section.

(121) On May 23, 1995, and June 7, 1995, the State submitted volatile organic compound control regulations for incorporation in the Illinois State Implementation Plan for ozone.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Sections 211.695, 211.696, 211.5245, 211.6025. These sections were adopted on May 4, 1995, Amended at 19 Ill. Reg. 7344, and effective May 22, 1995.

(B) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart V: 218.500, 218.501, 218.502, 218.503, 218.504, 218.505, 218.506. These sections were adopted on May 4, 1995, Amended at 19 Ill. Reg. 7359, and effective May 22, 1995.

(C) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart V: 219.500, 219.501, 219.502, 219.503, 219.504, 219.505, 219.506. These sections were adopted on May 4, 1995, Amended at 19 Ill. Reg. 7385, and effective May 22, 1995.

(122) On June 26, 1995, the Illinois Environmental Protection Agency (IEPA) submitted a State Implementation Plan (SIP) revision containing the 1992 enhancements to the Illinois vehicle inspection and maintenance (I/M) program. Such enhancements were originally developed to meet the I/M performance standard as called for in the United States Environmental Protection Agency's (USEPA's) proposed ‘post-1987’ I/M SIP policy and specified in the settlement agreement entered into by the parties in Wisconsin v. Reilly, Case No. 87-C-0395, E.D. Wis. The submittal includes authorizing legislation P.A. 86-1433, signed into law on September 12, 1990 and procedural rules published in the Illinois Register on June 26, 1992 at Volume 16, Issue #16.

(i) Incorporation by reference. (A) 35 Illinois Administrative Code 276; Sections 276.101, 276.102, 276.204, 276.206, 276.301, 276.303, 276.304, 276.307, 276.308, 276.309, 276.310, 276.311, 276.401, 276.402, 276.701, 276.702, and 276.703 amended or added at 16 Ill. Reg. 10230, effective June 15, 1992.

(ii) Other material. (A) Public Act 86-1433 adopted by the Illinois General Assembly on June 29, 1990, signed into law by Governor Edgar on September 12, 1990 effective September 12, 1990 (Sections 2,3, and 4) and January 1, 1991 (Section 1). (B) June 26, 1995 letter and attachments from the IEPA's Bureau of Air Chief to the USEPA's Regional Air and Radiation Division Director submitting Illinois' revision to the ozone SIP.

(123) On May 5, 1995, May 26, 1995, and May 31, 1995, the State of Illinois submitted miscellaneous revisions to its Volatile Organic Material (VOM) Reasonably Available Control Technology (RACT) rules contained in 35 Illinois Administrative Code Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, and Part 219: Organic Material Emission Standards and Limitations for the Metro East Area. These amendments clarify certain applicability provisions, control requirements, and compliance dates contained within these regulations. Also included in these amendments is an exemption for certain polyethylene foam packaging operations from VOM RACT requirements.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources.

(A) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart A: General Provisions, Section 218.106; Subpart T: Pharmaceutical Manufacturing, Section 218.480; Subpart DD: Aerosol Can Filling, Section 218.686; Subpart RR: Miscellaneous Organic Chemical Process, Section 218.966; Subpart TT: Other Emission Units, Section 218.980. Amended at 19 Ill. Reg. 6848; effective May 9, 1995.

(B) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart T: Pharmaceutical Manufacturing, Section 219.480; Subpart TT: Other Emission Units, Section 219.980. Amended at 19 Ill. Reg. 6958, effective May 9, 1995.

(124) The State of Illinois requested a revision to the Illinois State Implementation Plan (SIP). This revision is for the purpose of establishing and implementing a Clean-Fuel Fleet Program in the Chicago ozone nonattainment area, which includes Cook, DuPage, Grundy (Aux Sable and Goose Lake townships only), Kane, Kendall (Oswego township only), Lake, McHenry, and Will counties, to satisfy the federal requirements for a Clean Fuel Fleet Program to be part of the SIP for Illinois.

(i) Incorporation by reference. (A) 35 Illinois Administrative Code 241; Sections 241.101, 241.102, 241.103, 241.104, 241.110, 241.111, 241.112, 241.113, 241.114, 241.115, 241.130, 241.131, 241.140, 241.141, 241.142, 241. Appendix A, 241. Appendix B adopted in R95-12 at 19 Ill. Reg. 13265, effective September 11, 1995.

(ii) Other material. (A) September 29, 1995 letter and attachments from the Illinois Environmental Protection Agency's Bureau of Air Chief to the USEPA's Regional Air and Radiation Division Director submitting Illinois' revision to the ozone SIP.

(125) On November 14, 1995 the State submitted requested revisions to the Illinois State Implementation Plan in the form of revisions to the definitions of Organic Material and Organic Materials, Organic Solvent, Petroleum Liquid and Volatile Organic Material (VOM) or Volatile Organic Compound (VOC) intended to exempt acetone from regulation as a VOC.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.4250 Organic Material and Organic Materials, Section 211.4260 Organic Solvent, Section 211.4610 Petroleum Liquid, Section 211.7150 Volatile Organic Material (VOM) or Volatile Organic Compounds (VOC). Amended at 19 Ill. Reg. 15176, effective October 19, 1995.

(126) On November 15, 1995 the State submitted a requested revision to the Illinois State Implementation Plan in the form of a revision to the definition Volatile Organic Material (VOM) or Volatile Organic Compound (VOC) intended to exempt parachlorobenzotrifluoride and cyclic, branched or linear completely methylated siloxanes from the definition of VOM or VOC and thereby, from regulation as a VOC.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.7150 Volatile Organic Material (VOM) or Volatile Organic Compounds (VOC). Amended at 19 Ill. Reg. 11066, effective July 12, 1995.

(127) On October 21, 1993, and May 26, 1995, Illinois submitted volatile organic compound control regulations for incorporation in the Illinois State Implementation Plan for ozone.

(i) Incorporation by reference. (A) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 219: Organic Material Emissions Standards and Limitations for Metro East Area, Subpart PP: 219.920, 219.923, 219.927, 219.928; Subpart QQ: 219.940, 219.943, 219.947, 219.948; Subpart RR: 219.960, 219.963, 219.967, 219.968; Subpart TT: 219.980, 219.983, 219.987, 219.988; and Subpart UU. These Subparts were adopted on September 9, 1993, Amended at 17 Ill. Reg. 16918, effective September 27, 1993.

(B) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 219: Organic Material Emissions Standards and Limitations for Metro East Area, Subpart PP: 219.926; Subpart QQ: 219.946; Subpart RR: 219.966; and Subpart TT: 219.986. These Subparts were adopted on April 20, 1995, Amended at 19 Ill. Reg. 6958, effective May 9, 1995.

(128) On November 30, 1994, the State submitted volatile organic compound control regulations for incorporation in the Illinois State Implementation Plan for ozone.

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Sections 211.2300, 211.3695. These sections were adopted on October 20, 1994, Amended at 18 Ill. Reg. 16929, and effective November 15, 1994.

(B) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart B: 218.119, 218.120, 218.125, 218.127, 218.128, 218.129. These sections were adopted on October 20, 1994, Amended at 18 Ill. Reg. 16950, and effective November 15, 1994.

(C) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart B: 219.119, 219.120, 219.125, 219.127, 219.128, 219.129. These sections were adopted on October 20, 1994, Amended at 18 Ill. Reg. 16980, and effective November 15, 1994.

(129) [Reserved]

(130) On June 29, 1995, the State of Illinois submitted a revision to the State Implementation Plan (SIP) for the implementation of an enhanced motor vehicle inspection and maintenance (I/M) program in the Chicago and East St. Louis ozone nonattainment areas. This revision included the Vehicle Emissions Inspection Law of 1995 (625 ILCS 5/13B), P.A. 88-533, effective January 18, 1995; I/M regulations (R94-19 and R94-20) adopted on December 1, 1994, by the Illinois Pollution Control Board; February 29, 1996, Request-For-Proposals; April 22, 1996, letter of commitment; plus additional support documentation including modeling demonstration.

(i) Incorporation by reference. (A) Vehicle Emissions Inspection Law of 1995 (625 ILCS 5/13B), Public Act 88-533, signed into law by Governor Edgar on January 18, 1995 effective January 18, 1995.

(B) 35 Illinois Administrative Code 240; Sections 240.101, 240.102, 240.104, 240.105, 240.106, 240.107, 240.124, 240.125, 240.151, 240.152, 240.153, 240.161, 240.162, 240.163, 240.164, 240.171, 240.Table A, 240.Table B amended or added in R94-19 at 18 Ill. Reg. 18228, effective December 14, 1994.

(C) 35 Illinois Administrative Code 240; Sections 240.172, 240.173 amended in R94-20 at 18 Ill. Reg. 18013, effective December 12, 1994.

(ii) Additional materials. (A) February 29, 1996, Request-For-Proposals submitted on April 22, 1996.

(B) April 22, 1996, letter of commitment and attachments from IEPA's Bureau of Air Chief to the USEPA's Regional Air and Radiation Division Director.

(131) On January 10, 1996, the State of Illinois submitted a site-specific State Implementation Plan (SIP) revision request for ozone, which extends the required deadline for the Rexam Medical Packaging Inc. facility in Mundelein, Lake County, Illinois (Rexam), to comply with 35 Illinois Administrative Code, part 218, subpart H, as it applies to its Inline Press Number No.105, Inline Press No. 111, Offline 32-inch Press, Offline 36-inch Press, and Offline 42-inch press. The compliance date is extended from March 15, 1995, until June 15, 1996, or upon submittal of the “certificate of compliance” required under section 218.404 of subpart H, whichever occurs first. The variance includes a compliance plan requiring the installation and use of a catalytic oxidizer to control emissions from Inline Press No. 105, Inline Press No. 111, Offline 32-inch Press, and Offline 42-inch Press. The Offline 36-inch Press is required to convert to water-based ink, or be controlled by the oxidizer if the press is not converted by March 1, 1996. The variance is contingent upon certain compliance milestone conditions.

(i) Incorporation by reference. (A) Illinois Pollution Control Board Final Opinion and Order, PCB 95-99, adopted on October 19, 1995, and effective March 15, 1995. Certification of Acceptance dated November 29, 1996, by Rexam.

(132) On January 8, 1996, Illinois submitted a site-specific revision to the State Implementation Plan establishing lubricant selection and temperature control requirements for the hot and cold aluminum operations at Reynolds Metals Company's McCook Sheet and Plate Plant in McCook, Illinois (in Cook County), as part of the Ozone Control Plan for the Chicago area.

(i) Incorporation by reference. September 21, 1995, Opinion and Order of the Illinois Pollution Control Board AS 91-8, effective September 21, 1995.

(133) On July 23, 1996, the Illinois Environmental Protection Agency submitted a site-specific State Implementation Plan revision request for the Chase Products Company's Broadview (Cook County), Illinois facility located at 19th Street and Gardner Road, as part of the Ozone Control Plan for the Chicago area. The resulting revision revises the control requirements codified at 35 Illinois Administrative Code Part 218 Subpart DD Section 218.686 as they apply to the Chase Products Company's Broadview facility.

(i) Incorporation by reference. May 16, 1996, Opinion and Order of the Illinois Pollution Control Board AS 94-4, effective May 16, 1996.

(134) On May 5, 1995, and May 26, 1995, the State of Illinois submitted a State Implementation Plan revision request to the United States Environmental Protection Agency for reactor processes and distillation operation processes in the Synthetic Organic Chemical Manufacturing Industry as part of the State's control measures for Volatile Organic Material (VOM) emissions for the Chicago and Metro-East (East St. Louis) areas. VOM, as defined by the State of Illinois, is identical to “volatile organic compounds” (VOC), as defined by EPA. This plan was submitted to meet the Clean Air Act requirement for States to adopt Reasonably Available Control Technology rules for sources that are covered by Control Techniques Guideline documents. The EPA approves the State Implementation Plan revision request as it applies to Stepan Company's Millsdale Facility.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B; Definitions, 211.980 Chemical Manufacturing Process Unit, 211.1780 Distillation Unit, 211.2365 Flexible Operation Unit, 211.5065 Primary Product.

(B) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart Q: Synthetic Organic Chemical and Polymer Manufacturing Plant, Sections 218.431 Applicability, 218.432 Control Requirements, 218.433 Performance and Testing Requirements, 218.434 Monitoring Requirements, 218.435 Recordkeeping and Reporting Requirements, 218.436 Compliance Date, 218 Appendix G, TRE Index Measurement for SOCMI Reactors and Distillation Units, amended at 19 Ill. Reg. 6848, effective May 9, 1995.

(135) On January 23, 1996, Illinois submitted a site-specific revision to the State Implementation Plan which relaxes the volatile organic material (VOM) content limit for fabricated product adhesive operations at Solar Corporation's Libertyville, Illinois facility from 3.5 pounds VOM per gallon to 5.75 pounds VOM per gallon.

(i) Incorporation by reference. July 20, 1995, Opinion and Order of the Illinois Pollution Control Board, AS 94-2, effective July 20, 1995.

(136) On January 9, 1997, Illinois submitted a site-specific revision to the State Implementation Plan which grants a temporary variance from certain automotive plastic parts coating volatile organic material requirements at Solar Corporation's Libertyville, Illinois facility.

(i) Incorporation by reference. September 5, 1996, Opinion and Order of the Illinois Pollution Control Board, PCB 96-239, effective September 13, 1996. Certificate of Acceptance signed September 13, 1996.

(137) Approval—On April 25, 1997, the Illinois Environmental Protection Agency submitted a revision to the State Implementation Plan for general conformity rules. The general conformity rules enable the State of Illinois to implement the general conformity requirements in the nonattainment or maintenance areas at the State or local level in accordance with 40 CFR part 93, subpart B—Determining Conformity of General Federal Actions to State or Federal Implementation Plans.

(i) Incorporation by reference. (A) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 2: Environmental Protection Agency, Part 255 General Conformity: Criteria and Procedures. Adopted at 21 Ill. Reg. effective March 6, 1997.

(138) On May 5, 1995, and May 26, 1995, the State of Illinois submitted State Implementation Plan (SIP) revision requests for reactor processes and distillation operation processes in the Synthetic Organic Chemical Manufacturing Industry as part of the State's control measures for Volatile Organic Material emissions for the Metro-East (East St. Louis) area. This State Implementation Plan revision request is approved as it applies to Monsanto Chemical Group's Sauget Facility.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B; Definitions, 211.980 Chemical Manufacturing Process Unit, 211.1780 Distillation Unit, 211.2365 Flexible Operation Unit, 211.5065 Primary Product, amended at 19 Ill. Reg. 6823, effective May 9, 1995.

(B) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart Q: Synthetic Organic Chemical and Polymer Manufacturing Plant, Sections 219.431 Applicability, 219.432 Control Requirements, 219.433 Performance and Testing Requirements, 219.434 Monitoring Requirements, 219.435 Recordkeeping and Reporting Requirements, 219.436 Compliance Date, 219.Appendix G, TRE Index Measurement for SOCMI Reactors and Distillation Units, amended at 19 Ill. Reg. 6958, effective May 9, 1995.

(139) On September 8, 1997, the State of Illinois submitted tightened volatile organic material rules for cold cleaning degreasing operations in the Chicago and the Metro-East ozone nonattainment areas.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.1885, amended at 21 Ill. 7695, effective June 9, 1997.

(B) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart E: Solvent Cleaning, Section 218.182, amended at 21 Ill. 7708, effective June 9, 1997.

(C) Part 219: Organic Material Emissions Standards and Limitations for the Metro-East Area, Subpart E: Solvent Cleaning, Section 219.182, amended at 21 Ill. 7721, effective June 9, 1997.

(140) On March 5, 1998, the State of Illinois submitted amended rules for the control of volatile organic material emissions from wood furniture coating operations in the Chicago and Metro-East (East St. Louis) ozone nonattainment areas, as a requested revision to the ozone State Implementation Plan. This plan was submitted to meet the Clean Air Act requirement for States to adopt Reasonably Available Control Technology rules for sources that are covered by Control Techniques Guideline documents.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B; Definitions, 211.1467 Continuous Coater, 211.1520 Conventional Air Spray, 211.6420 Strippable Spray Booth Coating, 211.7200 Washoff Operations, amended at 22 Ill. Reg. 3497, effective February 2, 1998.

(B) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart F: Coating Operations 218.204 Emission Limitations, 218.205 Daily-weighted Average Limitations, 218.210 Compliance Schedule, 218.211 Recordkeeping and Reporting, 218.215 Wood Furniture Coating Averaging Approach, 218.216 Wood Furniture Coating Add-On Control Use, 218.217 Wood Furniture Coating Work Practice Standards, amended at 22 Ill. Reg. 3556, effective February 2, 1998.

(C) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart F: Coating Operations 219.204 Emission Limitations, 219.205 Daily-weighted Average Limitations, 219.210 Compliance Schedule, 219.211 Recordkeeping and Reporting, 219.215 Wood Furniture Coating Averaging Approach, 219.216 Wood Furniture Coating Add-On Control Use, 219.217 Wood Furniture Coating Work Practice Standards, amended at 22 Ill. Reg. 3517, effective February 2, 1998.

(141) On November 14, 1995, May 9, 1996, June 14, 1996, and February 3, 1997, October 16, 1997, and October 21, 1997, the State of Illinois submitted State Implementation Plan (SIP) revision requests to meet commitments related to the conditional approval of Illinois' May 15, 1992, SIP submittal for the Lake Calumet (SE Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM) nonattainment areas. The EPA is approving the portion of the SIP revision request that applies to the Granite City area. The SIP revision request corrects, for the Granite City PM nonattainment area, all of the deficiencies of the May 15, 1992, submittal.

(i) Incorporation by reference. (A) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 212: Visible and Particulate Matter Emissions, Subpart A: General, Sections 212.107, 212.108, 212.109, 212.110; Subpart L: Particulate Matter from Process Emission Sources, Section 212.324; Subpart N: Food Manufacturing, Section 212.362; Subpart Q: Stone, Clay, Glass and Concrete Manufacturing, Section 212.425; Subpart R: Primary and Fabricated Metal Products and Machinery Manufacture, Sections 212.446, 212.458; Subpart S: Agriculture, Section 212.464. Adopted at 20 Illinois Register 7605, effective May 22, 1996.

(B) Joint Construction and Operating Permit: Application Number 95010005, Issued on October 21, 1997, to Granite City Division of National Steel Corporation.

(142) On May 5, 1995, and May 26, 1995, the State of Illinois submitted State Implementation Plan revision requests for reactor processes and distillation operations in the Synthetic Organic Chemical Manufacturing Industry as part of the State's control measures for Volatile Organic Material emissions for the Chicago and Metro-East (East St. Louis) areas. This plan was submitted to meet the Clean Air Act requirement for States to adopt Reasonably Available Control Technology rules for sources that are covered by Control Techniques Guideline documents.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 211: Definitions and General Provisions, Subpart B; Definitions, 211.980 Chemical Manufacturing Process Unit, 211.1780 Distillation Unit, 211.2365 Flexible Operation Unit, 211.5065 Primary Product, amended at 19 Ill. Reg. 6823, effective May 9, 1995.

(B) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart Q: Synthetic Organic Chemical and Polymer Manufacturing Plant, Sections 218.431 Applicability, 218.432 Control Requirements, 218.433 Performance and Testing Requirements, 218.434 Monitoring Requirements, 218.435 Recordkeeping and Reporting Requirements, 218.436 Compliance Date, 218.Appendix G, TRE Index Measurement for SOCMI Reactors and Distillation Units, amended at 19 Ill. Reg. 6848, effective May 9, 1995.

(C) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart Q: Synthetic Organic Chemical and Polymer Manufacturing Plant, Sections 219.431 Applicability, 219.432 Control Requirements, 219.433 Performance and Testing Requirements, 219.434 Monitoring Requirements, 219.435 Recordkeeping and Reporting Requirements, 219.436 Compliance Date, 219.Appendix G, TRE Index Measurement for SOCMI Reactors and Distillation Units, amended at 19 Ill. Reg. 6958, effective May 9, 1995.

(143) [Reserved]

(144) On September 3, 1997, the Illinois Environmental Protection Agency submitted a temporary, site specific State Implementation Plan revision request for the D.B. Hess Company, Incorporated's (DB Hess) lithographic printing operations located in Woodstock (McHenry County), Illinois. This variance took the form of a March 20, 1997, Opinion and Order of the Illinois Pollution Control Board issued in PCB 96-194 (Variance—Air). The variance which will expire on March 30, 1999, grants DB Hess a variance from 35 Illinois Administrative Code Sections 218.407(a)(1)(C),(D),(E) and 218.411(b)(1), (2)and (3) for heatset web offset presses 3, 4, and 5 which are located at the Woodstock (McHenry County), Illinois facility.

(i) Incorporation by reference. (A) March 20, 1997, Opinion and Order of the Illinois Pollution Control Board in PCB 96-194 (Variance—Air) which was effective on March 20, 1997 and expires on March 30, 1999.

(ii) The variance is subject to the following conditions (the dates specified indicate the latest start dates of compliance periods terminating on March 30, 1999, when presses 3, 4, and 5 must be replaced by complying presses or must be brought into compliance with the rules from which DB Hess seeks the variance):

(A) On or before March 20, 1997, the combined actual volatile organic material (VOM) emissions from all of the presses in the Woodstock plant shall not exceed 18 tons per year or 1.5 tons per month.

(B) On or before March 20, 1997, DB Hess shall use only cleaning solutions with VOM concentrations less than or equal to 30 percent by weight.

(C) On or before March 20, 1997, DB Hess shall use cleaning solutions on presses 3, 4, and 5 that have a VOM composite partial vapor pressure of less than 10 millimeters (mm) of Mercury (Hg) at 20 degrees Celsius. These cleaning solutions must comply with the requirements of 35 IAC 218.407(a)(4).

(D) On or before March 20, 1997, DB Hess shall store and dispose of all cleaning towels in closed containers.

(E) On or before May 5, 1997, DB Hess shall monitor presses 3, 4, and 5 pursuant to 35 IAC 218.410 (b), (c), and (e).

(F) On or before May 5, 1997, DB Hess shall use fountain solutions on presses 3, 4, and 5 that are less than 5 percent VOM by volume, as applied, and which contain no alcohol.

(G) On or before May 5, 1997, DB Hess shall prepare and maintain records pursuant to 35 IAC 218.411 (b), (c), and (d) for presses 3, 4, and 5 and must show compliance with the requirements of 35 IAC 218.407(a)(1) (C), (D), and (E) and with the requirements of 35 IAC 218.411(b) (1), (2), and (3) for these presses.

(H) On or before May 5, 1997, DB Hess shall submit quarterly reports to the Illinois Environmental Protection Agency's (IEPA's) Compliance and Systems Management Section demonstrating compliance with the terms of the Illinois Pollution Control Board Order.

(I) On or before March 30, 1998, DB Hess shall cease operation of press 3.

(J) On or before March 30, 1999, DB Hess shall either:

(1) Cease operation of presses 4 and 5, and notify the IEPA of such cessation; or

(2) Retrofit presses 4 and 5 or replace presses 4 and 5 in compliance with 35 IAC 218.407 (a)(1) (C), (D), and (E) and with 35 IAC 218.411(b) (1), (2), and(3). In this case:

(i) DB Hess must apply for and obtain necessary construction permits by March 30, 1998, or six months before retrofitting or replacing presses 4 and 5, whichever is earlier.

(ii) DB Hess must send monthly status reports, due the 15th day of each month, to the IEPA, covering the progress of the installation of the presses and control equipment and testing of the control equipment.

(K) On or before March 30, 1999, DB Hess shall cease operations at presses 3, 4, and 5 except for those presses for which it has obtained permits and installed controls, which have been tested and demonstrated to be in compliance with applicable rules.

(145) On September 16, 1998, the State of Illinois submitted amendments to Volatile Organic Material (VOM) rules affecting Illinois' ozone attainment area (the area of the State not including the Chicago and Metro-East ozone nonattainment areas). The amendments contain various deletions of obsolete provisions, changes of some word usage to comport Part 215 with other Illinois VOM regulations, and the addition of certain exemptions from VOM coating requirements.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources.

(A) Part 215: Organic Material Emission Standards and Limitations; Subpart A: General Provisions, 215.104 Definitions, 215.109 Monitoring for Negligibly-Reactive Compounds; Subpart F: Coating Operations, 215.204 Emission Limitations for Manufacturing Plants, 215.205 Alternative Emission Limitations, 215.206 Exemptions from Emission Limitations, 215.207 Compliance by Aggregation of Emissions Units, 215.211 Compliance Dates and Geographical Areas, 215.212 Compliance Plan, and 215.214 Roadmaster Emissions Limitations (Repealed); Subpart Z: Dry Cleaners, 215.601 Perchloroethylene Dry Cleaners (Repealed), 215.602 Exemptions (Repealed), 215.603 Leaks (Repealed), 215.604 Compliance Dates and Geographical areas (Repealed), 215.605 Compliance Plan (Repealed), and 215.606 Exception to Compliance Plan (Repealed), amended at 22 Ill. Reg. 11427, effective June 19, 1998.

(146) On February 13, 1998, the Illinois Environmental Protection Agency (IEPA) submitted a revision to the Illinois State Implementation Plan (SIP). This revision amends certain sections of the Clean-Fuel Fleet Program (CFspan) in the Chicago ozone nonattainment area to reflect that fleet owners and operators will have an additional year to meet the purchase requirements of the CFspan. The amendment changes the first date by which owners or operators of fleets must submit annual reports to IEPA from November 1, 1998 to November 1, 1999. In addition, this revision corrects two credit values in the CFspan credit program.

(i) Incorporation by reference. (A) 35 Illinois Administrative Code 241; Sections 241.113, 241.130, 241.140, 241.Appendix B.Table A, 241.Appendix B.Table D adopted in R95-12 at 19 Ill. Reg. 13265, effective September 11, 1995; amended in R98-8, at 21 Ill. Reg. 15767, effective November 25, 1997.

(ii) Other material. (A) February 13, 1998, letter and attachments from the Illinois Environmental Protection Agency's Bureau of Air Chief to the United States Environmental Protection Agency's Regional Air and Radiation Division Director submitting Illinois' amendments to the Clean Fuel Fleet regulations as a revision to the ozone State Implementation Plan.

(147) On June 21, 1997, and December 9, 1998, the State of Illinois submitted regulations adopted by the Illinois Pollution Control Board and the Illinois Environmental Protection Agency and legislation adopted by the General Assembly and signed by the Governor related to Illinois' vehicle inspection and maintenance (I/M) program. The purpose of these submittals was to change the existing program from a basic I/M program to a fully enhanced I/M program. These changes modify the program in both the Chicago and Saint Louis (Illinois Portion) Ozone nonattainment areas.

(i) Incorporation by reference. (A) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter k: Emission Standards and Limitations for Mobile sources, Part 240 Mobile Sources, Except for Section 240. Table C. Adopted at 22 Ill. Reg. 13723, effective July 13, 1998.

(B) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter k: Emission Standards and Limitations for Mobile sources, Part 240 Mobile Sources, Section 240. Table C. Corrected at 22 Ill. Reg. 21120, effective July 13, 1998.

(C) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter II: Environmental Protection Agency, Part 276 Procedures to be Followed in the Performance of Inspections of Motor Vehicle Emissions. Amended at 22 Ill. Reg. 18867, effective September 28, 1998.

(ii) Other materials. (A) Transmittal letters dated June 21, 1997, and December 9, 1998.

(B) Public Act 90-475, effective August 17, 1997. This Act amends the Illinois Environmental Protection Act by changing Sections 3.32, 3.78, 21, and 22.15 and adding Sections 3.78a and 22.38.

(148) On October 13, 1998, the State of Illinois submitted a site-specific State Implementation Plan (SIP) revision affecting Volatile Organic Material controls at Central Can Company (CCC), located in Chicago, Illinois. The SIP revision allows CCC to apply can coating control rules to pail coating operations limited to certain conditions.

(i) Incorporation by reference. August 6, 1998, Opinion and Order of the Illinois Pollution Control Board, AS 94-18, effective July 1, 1991.

(149) On September 17, 1998, the Illinois Environmental Protection Agency submitted a site specific State Implementation Plan revision request for W.R. Grace and Company's facility, which manufactures container sealants, lubricant fluids, and concrete additives, and is located at 6050 West 51st Street in Chicago, Illinois (Cook County). This rule revision is contained in R98-16, the July 8, 1998, Opinion and Order of the Illinois Pollution Control Board, and consists of new Section 218.940(h), which exempts W.R. Grace's facility from the control requirements in 35 Illinois Administrative Code Part 218 Subpart QQ.

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 218 Organic Material Emission Standards and Limitations for the Chicago Area, Subpart QQ: Miscellaneous Formulation Manufacturing Processes, Section 218.940 Applicability, paragraph (h) which was amended in R98-16 at 22 Ill. Reg. 14282, effective July 16, 1998.

(150) On November 14, 1995, May 9, 1996, June 14, 1996, February 1, 1999, and May 19, 1999, the State of Illinois submitted State Implementation Plan (SIP) revision requests to meet commitments related to the conditional approval of Illinois' May 15, 1992, SIP submittal for the Lake Calumet (Southeast Chicago), McCook, and Granite City, Illinois, Particulate Matter (PM) nonattainment areas. The EPA is approving the SIP revision request as it applies to the Lake Calumet area. The SIP revision request corrects, for the Lake Calumet PM nonattainment area, all of the deficiencies of the May 15, 1992, submittal.

(i) Incorporation by reference.

(A) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 212: Visible and Particulate Matter Emissions, Subpart A: General, Section 212.113; Subpart E: Particulate Matter from Fuel Combustion Sources, Section 212.210; Subpart K: Fugitive Particulate Matter, Sections 212.302, 212.309, and 212.316. Adopted at 20 Illinois Register 7605, effective May 22, 1996.

(B) Federally Enforceable State Operating Permit—Special: Application Number 98120091, Issued on May 14, 1999, to LTV Steel Company, Inc.

(151) On July 23, 1998, the State of Illinois submitted a State Implementation Plan (SIP) revision that included certain “clean-up” amendments to the State's permitting rules.

(i) Incorporation by reference.

Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board.

(A) Subchapter A: Permits and General Provisions, Part 201: Permits and General Provisions.

(1) Subpart D: Permit Applications and Review Process, Section 201.152 Contents of Application for Construction Permit, 201.153 Incomplete Applications (Repealed), Section 201.154 Signatures (Repealed), Section 201.155 Standards for Issuance (Repealed), Section 201.157 Contents of Application for Operating Permit, Section 201.158 Incomplete Applications, Section 201.159 Signatures, 201.160 Standards for Issuance, Section 201.162 Duration, Section 201.163 Joint Construction and Operating Permits, and Section 201.164 Design Criteria. Amended at 22 Ill. Reg. 11451, effective June 23, 1998.

(2) Subpart E: Special Provisions for Operating Permits for Certain Smaller Sources, Section 201.180 Applicability (Repealed), Section 201.181 Expiration and Renewal (Repealed), Section 201.187 Requirement for a Revised Permit (Repealed), Repealed at 22 Ill. Reg. 11451, effective June 23, 1998.

(3) Subpart F: CAAPP Permits, Section 201.207 Applicability, Amended at 22 Ill. Reg. 11451, effective June 23, 1998.

(152) On February 5, 1998, the Illinois Environmental Protection Agency submitted a requested revision to the Illinois State Implementation Plan. This revision provided additional exemptions from State of Illinois permit requirements codified by the State at Part 201 of Title 35 of the Illinois Administrative Code (35 IAC Part 201). The revision also added a definition of “Feed Mill” to Part 211 of 35 IAC (35 IAC Part 211).

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter C: Emission Standards and Limitations for Stationary Sources.

(A) Part 211 Definitions and General Provisions, Subpart B: Definitions, Section 211.2285 Feed Mill. Added at 21 Ill. Reg. 7856, effective June 17, 1997.

(B) Part 201 Permits and General Conditions, Subpart C: Prohibitions, Section 201.146 Exemptions from State Permit Requirements. Amended at 21 Ill. Reg. 7878, effective June 17, 1997.

(153) On July 9, 1999, the State of Illinois submitted a site-specific State Implementation Plan (SIP) revision affecting Volatile Organic Material control requirements at Sun Chemical Corporation (Sun) in Northlake, Illinois. The SIP revision changes requirements for 17 resin storage tanks operated by Sun. Specifically, the SIP revision exempts the 17 tanks from the bottom or submerged fill pipe requirements, provided that no odor nuisance exists at the Sun Northlake facility, and that the vapor pressures of materials stored in the tanks remain less the 0.5 pounds per square inch absolute at 70 degrees Fahrenheit.

(i) Incorporation by reference.

May 20, 1999, Opinion and Order of the Illinois Pollution Control Board, AS 99-4, effective May 20, 1999.

(155) On May 21, 1999, the Illinois Environmental Protection Agency submitted a temporary, site-specific revision to the State Implementation Plan (SIP) for sulfur dioxide (SO2) for the Central Illinois Light Company's E.D. Edwards Generating Station in Peoria County, Illinois (CILCO Edwards). The SIP revision took the form of an April 15, 1999, Opinion and Order of the Illinois Pollution Control Board (PCB 99-80, Variance-Air). In this Opinion and Order, the IPCB granted CILCO Edwards a variance from 35 Illinois Administrative Code 214.141, and provided for a relaxation in the fuel quality limit for one of the facility's three boilers, but added an overall fuel quality limit and retained an overall SO2 emissions cap for the three CILCO Edwards boilers. The variance will expire on February 28, 2002, unless CILCO applies to Illinois for a permanent SIP revision.

(i) Incorporation by reference. An April 15, 1999, Opinion and Order of the Illinois Pollution Control Board in PCB 99-80 (Variance-Air), granting a variance from 35 IAC 214.141 for Boiler No. 2 at the Central Illinois Light Company's E.D. Edwards Generating Station near Peoria, Illinois. The variance expires on February 28, 2002, unless CILCO applies to Illinois for a permanent SIP revision. If CILCO applies for a permanent SIP revision, and the IPCB allows CILCO Edwards' variance to continue unamended through July 31, 2003, as stated in the Opinion and Order, then federal approval of the variance will continue until EPA approves alternate SO2 limits for CILCO Edwards, or until July 31, 2003, whichever is earlier.

(156) On May 8, 2001, the State submitted rules to control Oxides of Nitrogen emissions from electric generating units.

(i) Incorporation by reference. Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter C: Emission Standards and Limitations for Stationary Sources; Part 217 Nitrogen Oxides Emissions; Subpart V: Electric Power Generation. Adopted at 25 Ill. Reg. 5914, effective April 17, 2001.

(157) On May 8, 2001, the Illinois Environmental Protection Agency submitted revisions to 35 Ill. Adm. Code 217, Subpart W: NO[x] Trading Program for Electrical Generating Units with a request that these rules be incorporated into the Illinois State Implementation Plan. On June 11, 2001, the Illinois EPA submitted Section 9.9(f) of the Illinois Environmental Protection Act as revised by Public Act 92-012 (formerly House Bill 1599) which was approved by both Houses of the Illinois General Assembly on June 7, 2001, approved by the Governor on June 22, 2001, and became effective on July 1, 2001. Section 9.9(f) requires a May 31, 2004 final compliance date for 35 Ill. Adm. Code 215, Subparts T, U and W. This compliance date replaces the compliance date contained in Section 217.756(d)(3).

(i) Incorporation by reference. (A) Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 217 Nitrogen Oxides Emissions, Subpart W: NO[x] Trading Program for Electrical Generating Units except for 217.756(d)(3) which has been superseded by Section 9.9(f) of the Illinois Environmental Protection Act. Added at 25 Ill. Reg. 128, January 25, 2001, effective December 26, 2000.

(B) Section 9.9(f) of the Illinois Environmental Protection Act. Adopted by both Houses of the Illinois General Assembly as part of Public Act 92-0012 (previously House Bill 1599) on May 31, 2001, approved by the Governor of Illinois on June 22, 2001, effective July 1, 2001.

(158) On December 16, 1997, Bharat Mathur, Chief, Bureau of Air, Illinois Environmental Protection Agency, submitted rules for a cap and trade program regulating volatile organic compound emissions in the Chicago area. By letter dated August 23, 2001, the state requested that USEPA defer rulemaking on section 205.150(e), which exempts new and modified sources obtaining offsets under the trading program from the requirements for traditional, full year offsets.

(i) Incorporation by reference. Illinois Administrative Code, Title 35, Subtitle B, Chapter I, subchapter b, Part 205, entitled Emissions Reduction Market System, adopted November 20, 1997, effective November 25, 1997, except section 205.150(e).

(159) On April 9, 2001, David Kolaz, Chief, Bureau of Air, Illinois Environmental Protection Agency, submitted rules regulating NOX emissions from cement kilns. On May 1, 2001, Mr. Kolaz submitted rules regulating NOX emissions from industrial boilers and turbines and requesting two minor revisions to the Illinois NOX emissions budget. On June 18, 2001, Mr. Kolaz submitted a demonstration that Illinois' regulations were sufficient to assure that NOX emissions in Illinois would be reduced to the level budgeted for the state by USEPA. On September 20, 2001, Mr. Kolaz sent a letter clarifying that Illinois' rules for industrial boilers and turbines require compliance on a unit-by-unit basis.

(i) Incorporation by reference. (A) Illinois Administrative Code, Title 35, Subtitle B, Chapter I, subchapter c, Part 211, Definitions, sections 211.955, 211.960, 211.1120, 211.3483, 211.3485, 211.3487, 211.3780, 211.5015, and 211.5020, published at 25 Ill. Reg. 4582, effective March 15, 2001.

(B) Illinois Administrative Code, Title 35, Subtitle B, Chapter I, subchapter c, Part 217, Subpart A, Section 217.104, Incorporations by Reference, published at 25 Ill. Reg. 4597, effective March 15, 2001.

(C) Illinois Administrative Code, Title 35, Subtitle B, Chapter I, subchapter c, Part 217, Subpart T, Cement Kilns, sections 217.400, 217.400, 217.402, 217.404, 217.406, 217.408, and 217.410, published at 25 Ill. Reg. 4597, effective March 15, 2001.

(D) Illinois Administrative Code, Title 35, Subtitle B, Chapter I, subchapter c, Part 211, Sections 211.4067 and 211.6130, published at 25 Ill. Reg. 5900, effective April 17, 2001.

(E) Illinois Administrative Code, Title 35, Subtitle B, Chapter I, subchapter c, Part 217, Subpart U, NOX Control and Trading Program for Specified NOX Generating Units, sections 217.450, 217.452, 217.454, 217.456, 217.458, 217.460, 217.462, 217.464, 217.466, 217.468, 217.470, 217.472, 217.474, 217.476, 217.478, 217.480 and 217.482, published at 25 Ill. Reg. 5914, effective April 17, 2001.

(ii) Additional material. (A) Letter dated June 18, 2001, from David Kolaz, Illinois Environmental Protection Agency, to Cheryl Newton, United States Environmental Protection Agency.

(B) Letter dated September 20, 2001, from David Kolaz, Illinois Environmental Protection Agency, to Bharat Mathur, United States Environmental Protection Agency.

(160) On March 21, 2001, Illinois submitted revisions to volatile organic compound rules for Formel Industries, Incorporated in Cook County, Illinois. The revisions consist of a January 18, 2001 Opinion and Order of the Illinois Pollution Control Board in the Matter of: Petition of Formel Industries, Inc. for an Adjusted Standard from 35 ILL. ADM. CODE 218.401(a),(b) and (c): AS 00-13 (Adjusted Standard Air). This Opinion and Order grants Formel Industries, Incorporated an adjusted standard to the Flexographic Printing Rule. The adjusted standard requirements include participation in a market-based emissions trading system, maintaining daily records, conducting trials of compliant inks, and reviewing alternate control technologies.

(i) Incorporation by reference. Volatile organic compound emissions limits contained in a January 18, 2001 Opinion and Order of the Illinois Pollution Control Board in the Matter of: Petition of Formel Industries, Inc. for an Adjusted Standard from 35 ILL. ADM. CODE 218.401(a), (b) and (c): AS 00-13 (Adjusted Standard-Air). This Opinion and Order was adopted by the Illinois Pollution Control Board on January 18, 2001. It became effective under State law on January 18, 2001.

(161) On March 28, 2001, Illinois submitted revisions to volatile organic compound rules for Bema Film Systems, Incorporated in DuPage County, Illinois. The revisions consist of AS 00-11, an adjusted standard to the Flexographic Printing Rule, 35 IAC 218.401 (a), (b), and (c). The adjusted standard requirements include reducing the allotment baseline for the Illinois market-based emissions trading system, maintaining daily records, conducting trials of compliant inks, and reviewing alternate control technologies.

(i) Incorporation by reference. AS 00-11, an adjusted standard from the Volatile Organic Compound emission limits for Bema Film Systems, Inc. contained in Illinois Administrative Code Title 35: Environmental Regulations for the State of Illinois, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 218.401 (a), (b), and (c). Effective on January 18, 2001.

(ii) Other material. (A) November 14, 2001, letter from Dennis A. Lawler, Manager, Division of Air Pollution Control, Illinois Environmental Protection Agency to Jay Bortzer, Chief, Regulation Development Section, Air and Radiation Division, USEPA, Region 5, indicating that the effective date of the adjusted standard for Bema Film Systems, Inc. AS 00-11, is January 18, 2001, the date that AS 00-11 was adopted by the Illinois Pollution Control Board.

(162) On March 28, 2001, Illinois submitted revisions to volatile organic compound rules for Vonco Products, Incorporated in Lake County, Illinois. The revisions consist of AS 00-12, an adjusted standard to the Flexographic Printing Rule, 35 IAC 218.401 (a), (b), and (c). The adjusted standard requirements include reducing the allotment baseline for the Illinois market-based emissions trading system, maintaining daily records, conducting trials of compliant inks, and reviewing alternate control technologies.

(i) Incorporation by reference. AS 00-12, an adjusted standard from the Volatile Organic Compound emission limits applicable to Vonco Products, Inc. contained in Illinois Administrative Code Title 35: Environmental Regulations for the State of Illinois, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 218.401 (a), (b), and (c). Effective on January 18, 2001.

(ii) Other material. (A) November 14, 2001, letter from Dennis A. Lawler, Manager, Division of Air Pollution Control, Illinois Environmental Protection Agency to Jay Bortzer, Chief, Regulation Development Section, Air and Radiation Division, USEPA, Region 5, indicating that the effective date of the adjusted standard for Vonco Products, Inc. AS 00-12, is January 18, 2001, the date that AS 00-12 was adopted by the Illinois Pollution Control Board.

(163) [Reserved]

(164) On October 9, 2001, the State of Illinois submitted new rules regarding emission tests.

(i) Incorporation by reference. (A) New rules of 35 Ill. Admin. Code Part 283, including sections 283.110, 283.120, 283.130, 283.210, 283.220, 283.230, 283.240, and 283.250, effective September 11, 2000, published in the Illinois Register at 24 Ill. Reg. 14428.

(B) Revised section 283.120 of 35 Ill. Admin. Code, correcting two typographical errors, effective September 11, 2000, published in the Illinois Register at 25 Ill. Reg. 9657.

(165) On April 8, 1999, the Illinois Environmental Protection Agency submitted revisions to particulate matter control requirements for rural grain elevators in Illinois. The revised requirements exempt rural grain elevators from certain particulate matter control requirements.

(i) Incorporation by reference. Revised grain elevator provisions in Section 9(f) of the Illinois Environmental Protection Act. Adopted by both Houses of the Illinois General Assembly as Public Act 89-491 (previously Senate Bill 1633) on April 25, 1996, approved by the Governor of Illinois on May 23, 1996, effective June 21, 1996.

(166) On November 6, 2001, the State of Illinois submitted revisions to its emission reporting rules, restructuring these rules and adding hazardous air pollutant emission reporting for sources in Illinois' Emission Reduction Market System.

(i) Incorporation by reference. (A) Revised rules of 35 Ill. Admin. Code Part 254, including new or amended sections 254.101, 254.102, 254.103, 254.120, 254.132, 254.134, 254.135, 254.136, 254.137, 254.138, 254.203, 254.204, 254.303, 254.306, and 254.501, effective July 17, 2001, retention of section 254.133, and the repeal of other previously approved sections of 35 Ill. Admin. Code 254. Amended or adopted at 25 Ill. Reg. 9856. Effective July 17, 2001.

(167) On August 31, 1998, Illinois submitted revisions to its major stationary sources construction and modification rules (NSR Rules) as a State Implementation Plan revision request. These revisions apply only in areas in Illinois that have been designated as being in serious or severe nonattainment with the national ambient air quality standards for ozone.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter A: Permits and General Provisions, Part 203 Major Stationary Sources Construction and Modification, Subpart B: Major Stationary Sources in Nonattainment Areas, Section 203.206 Major Stationary Source and Section 203.207 Major Modification of a Source; and, Subpart C: Requirements for Major Stationary Sources in Nonattainment Areas, Section 203.301 Lowest Achievable Emissions Rate. Amended in R98-10 at 22 Ill. Reg. 5674, effective March 10, 1998.

(168) On October 31, 2003, the Illinois Environmental Protection Agency submitted revisions to the Illinois State Implementation Plan for ozone. The submittal revises the definition for volatile organic material (VOM) or volatile organic compound (VOC) contained in 35 Ill. Adm. Code 211.7150 to incorporate an exemption for perchloroethylene (tetrachloroethylene); 3,3-dichloro-1,1,1,2,2-pentafluoropropane (HCFC-225ca); 1,3-dichloro-1,1,2,2,3-pentafluoropropane (HCFC-225cb); decafluoropentane (HFC 43-10mee); difluoromethane (HFC-32); ethylfluoride (HFC-161); 1,1,1,3,3,3-hexafluoropropane (HFC-236fa); 1,1,2,2,3-pentafluoropropane (HFC-245ca); 1,1,2,3,3-pentafluoropropane (HFC-245ea); 1,1,1,2,3-pentafluoropropane (HFC-245eb); 1,1,1,3,3-pentafluoropropane (HFC-245fa); 1,1,1,2,3,3-hexafluoropropane (HFC-236ea); 1,1,1,3,3-pentafluorobutane (HFC-365mfc); chlorofluoromethane (HCFC-31); 1,2-dichloro-1,1,2-trifluoroethane (HCFC-123a); 1-chloro-1-fluoroethane (HCFC-151a); 1,1,1,2,2,3,3,4,4-nonafluoro-4-methoxybutane (C4F9OCH3); 2-(difluoromethoxymethyl)-1,1,1,2,3,3,3-heptafluoropropane ((CF3)2CFCF2OCH3); 1-ethoxy-1,1,2,2,3,3,4,4,4-nonafluorobutane (C4F9OC2H5); 2-(ethoxydifluoromethyl)-1,1,1,2,3,3,3-heptafluoropropane ((CF3)2CFCF2OC2H5); and methyl acetate from the definition of VOM or VOC and thereby, from regulation as ozone precursors.

(i) Incorporation by reference. (A) Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.7150 Volatile Organic Material (VOM) or Volatile Organic Compound (VOC), amended at 22 Illinois Register 11405, effective June 22, 1998.

(169) On June 20, 2003, Illinois submitted an Adjusted Standard for Ford Motor Company's Chicago Assembly Plant. This Adjusted Standard from 35 Ill.Adm. Code 218.986 replaces those requirements with the control requirements in the Illinois Pollution Control Board's November 21, 2002, Order.

(i) Incorporation by reference. (A) The Illinois Pollution Control Board's November 21, 2002, Opinion and Order which granted the Ford Motor Company's Chicago Assembly Plant an adjusted standard (AS 02-3) from 35 Ill. ADM. Code 218.986. The requirements in 35 Ill. ADM. Code 218.986 have been replaced by the requirements in the Illinois Pollution Control Board's November 21, 2002, Order.

(170) On May 28, 2003, Illinois submitted an amendment to its leather coating rules for the Horween Leather Company's Chicago leather manufacturing facility. This adds a test method in Section 218.112(a)(26) and a new Section 35 Ill. Adm. Code 218.929. These amendments were incorporated in the Illinois Pollution Control Board's February 20, 2003, Final Order R02-20.

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 218 Organic Material Emission Standards and Limitations for the Chicago Area.

(A) Subpart A: General Provisions, Section 218.112 Incorporations by Reference, (a) American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-9555, 26) ASTM D2099-00. Amended at 27 Ill. Reg. 7283, effective April 8, 2003.

(B) Subpart PP: Miscellaneous Fabricated Product Manufacturing Processes, Section 218.929 Cementable and Dress or Performance Shoe Leather. Added at 27 Ill. Reg. 7283, effective April 8, 2003.

(171) On July 29, 2003, the Illinois Environmental Protection Agency submitted a site-specific revision to the State Implementation Plan (SIP) for sulfur dioxide (SO2) for the Central Illinois Light Company's E.D. Edwards Generating Station, now known as AmerenEnergy Resources Generating Company, Edwards Power Plant, in Bartonville, Peoria County, Illinois.

(i) Incorporation by reference.

Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Stationary Sources, Part 214: Sulfur Limitations, Subpart X: Utilities Section 214.561 E.D. Edwards Electric Generating Station which was amended at 27 Illinois Register 12101, effective July 11, 2003.

(172) On September 19, 2003, Illinois submitted a site-specific revision to the State Implementation Plan which relaxes the volatile organic material (VOM) content limit for the coating operations at Louis Berkman Company, d/b/a/ the Swenson Spreader Company's Lindenwood, Ogle County, Illinois facility from 3.5 pounds VOM per gallon to a monthly average of 4.75 pounds VOM per gallon until May 7, 2008.

(i) Incorporation by reference. Order contained in a May 7, 1998, Opinion and Order of the Illinois Pollution Control Board, AS 97-5, effective May 7, 1998.

(173) On March 11, 2004, Illinois submitted an Adjusted Standard for Argonne National Laboratory's degreasing operations. Pursuant to this Adjusted Standard from 35 Ill. Adm. Code 218.182, the applicable vapor pressure and other associated requirements of 35 Ill. Code 218.182 do not apply to cold cleaning involving the preparation of sample materials and associated apparatus used for research and development testing and analysis at Argonne. These revised requirements were adopted in the Illinois Pollution Control Board's December 18, 2003, Adjusted Standard AS 03-4.

(i) Incorporation by reference. (A) The Illinois Pollution Control Board's December 18, 2003, Opinion and Order which granted the Argonne National Laboratory's degreasing operations an Adjusted Standard (AS 03-4) from 35 Ill. Code 218.182 for its cold cleaning involving the preparation of sample materials and associated apparatus used for research and development testing and analysis at Argonne.

(174) [Reserved]

(175) On January 4, 2006, Illinois submitted a site-specific State Implementation Plan revision for the Ford Motor Company (Ford) Chicago Assembly Plant. The revision allows Ford to discontinue use of its Stage II vapor recovery system and requires instead that Ford comply with federal onboard refueling vapor recovery regulations and other conditions.

(i) Incorporation by reference.

(A) September 1, 2005, Opinion and Order of the Illinois Pollution Control Board, AS 05-5, effective September 1, 2005.

(176) On June 14, 2004, Illinois submitted revisions to volatile organic compound rules for Formel Industries, Incorporated in Cook County, Illinois. The revisions consist of withdrawing an adjusted standard to the Flexographic Printing Rule. Formel Industries has installed a control device and is complying with the Flexographic Printing Rule.

(i) Incorporation by reference. An April 15, 2004, Supplemental Opinion and Order of the Illinois Pollution Control Board AS 00-13, terminating Formel's previously issued (January 18, 2001) adjusted standard from the Flexographic Printing Rule, effective April 15, 2004.

(177) On May 31, 2006, the Illinois Environmental Protection Agency submitted a requested revision to the Illinois State Implementation Plan. This revision provides additional exemptions from State of Illinois permit requirements codified by the State at Part 201 of Title 35 of the Illinois Administrative Code (35 IAC Part 201).

(i) Incorporation by reference.

Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter a: Permits and General Provisions, Part 201 Permits and General Provisions, Subpart C: Prohibitions, Section 201.146 Exemptions from State Permit Requirements paragraphs (hhh), (iii), (jjj), (kkk), and (lll). Amended at 30 Ill. Reg. 4901, effective March 3, 2006.

(178) On September 14, 2007, the Illinois Environmental Protection Agency submitted rules and related material to address requirements under the Clean Air Interstate Rule. These rules mandate participation of electric generating units in EPA-run trading programs for annual emissions of sulfur dioxide, annual emissions of nitrogen oxides, and ozone season emissions of nitrogen oxides. These rules provide a methodology for allocating allowances to subject sources and require these sources to hold sufficient allowances to accommodate their emissions and to meet various monitoring, recordkeeping, and reporting requirements. EPA is approving the submitted provisions of Subparts A, C, D, and E of Part 225 of Title 35 of Illinois Administrative Code; EPA is deferring action on Subpart F.

(i) Incorporation by reference.

(A) Title 35 of the Illinois Administrative Code: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Part 225: Control of Emissions from Large Combustion Sources, effective August 31, 2007, including Subpart A: General Provisions, Subpart C: Clean Air Act Interstate Rule (CAIR) SO2 Trading Program, Subpart D: CAIR NOX Annual Trading Program, and Subpart E: CAIR NOX Ozone Season Trading Program.

(179) On October 31, 2003, the Illinois Environmental Protection Agency submitted rules and related materials to address site-specific requirements for Cromwell-Phoenix, Incorporated, located in Alsip, Illinois. These rules establish an adjusted standard for the corrosion inhibiting packaging production facility of Cromwell-Phoenix, Incorporated located at this source site. These rules provide a site-specific adjusted standard for this source facility for volume 35 of the Illinois Administrative Code subpart F section 218.204(c). The adjusted standard gives the corrosion inhibiting paper coating lines at the Alsip facility an adjusted volatile organic material (volatile organic compounds) content limit for paper coatings, and places an annual limit on the volatile organic material emissions from the Alsip facility as a whole. The adjusted standard also establishes source administration and reporting requirements for Cromwell-Phoenix, Incorporated Alsip facility. EPA is approving this site-specific adjusted standard as a revision of the Illinois state implementation plan.

(i) Incorporation by reference.

(A) September 18, 2003, Opinion and Order of the Illinois Pollution Control Board, AS 03-5, effective September 18, 2003.

(180) On January 10, 2007, Illinois submitted revisions to its rules for the Emission Reduction Market System. These revisions assure that sources in the Chicago area with potential emissions of VOC between 25 and 100 tons per year will remain subject to the program, irrespective of changes in the area's ozone nonattainment classification or designation and any associated changes in whether such sources are defined to be major sources. EPA is again deferring action on section 205.150(e).

(i) Incorporation by reference.

(A) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter b: Alternative Reduction Program, Part 205 Emissions Reduction Market System, Sections:

205.120 Abbreviations and Acronyms 205.130 Definitions 205.150 Emissions Management Periods (except for 205.150(e)) 205.200 Participating Source 205.205 Exempt Source 205.210 New Participating Source 205.220 Insignificant Emission Units 205.300 Seasonal Emissions Component of the Annual Emissions Report 205.310 ERMS Applications 205.315 CAAPP Permits for ERMS Sources 205.316 Federally Enforceable State Operating Permits for ERMS Sources 205.318 Certification for Exempt CAAPP Sources 205.320 Baseline Emissions 205.330 Emissions Determination Methods 205.335 Sampling, Testing, Monitoring and Recordkeeping Practices 205.337 Changes in Emissions Determination Methods and Sampling, Testing, Monitoring and Recordkeeping Practices 205.400 Seasonal Emissions Allotment 205.405 Exclusions From Further Reductions 205.410 Participating Source Shutdowns 205.500 Emissions Reduction Generator 205.510 Inter-Sector Transaction 205.610 Application for Transaction Account 205.700 Compliance Accounting 205.730 Excursion Reporting 205.750 Emergency Conditions 205.760 Market System Review Procedures

(181) On August 17, 2005 and January 29, 2008, Illinois submitted revised regulations that are consistent with 40 CFR 51.100(s)(1), as amended by 69 FR 69298. The compounds 1,1,1,2,2,3,3-heptafluoro-3-methoxypropane (n-C3F7OCH3), 3-ethoxy 1,1,1,2,3,4,4,5,5,6,6,6-dodecafluoro-2-(trifluoromethyl)hexane (HFE-7500), 1,1,1,2,3,3,3-heptafluoropropane (HFC-227ea), and methyl formate were added to the list of negligibly reactive compounds excluded from the definition of VOM in 35 IAC 211.7150(a). Tertiary-butyl acetate is also listed in 35 IAC 211.7150(a) with a notation that it must also meet the requirements of 35 IAC 211.7150(e), which state that tertiary-butyl acetate is considered a VOC for recordkeeping, emissions reporting, modeling, and inventory requirements, but is not considered a VOC for emission limits or content requirements.

(i) Incorporation by reference.

(A) Illinois Administrative Code Title 35: Environmental Protection, Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.7150: Volatile Organic Matter (VOM) or Volatile Organic Compound (VOC), Subsections 211.7150(a) and 211.7150(e). Effective January 16, 2008.

(182) On January 29, 2008, Illinois submitted revised regulations that are consistent with 40 CFR 51.100(s)(1), as amended by 72 FR 2193. The compound 1,1,1,2,2,3,4,5,5,5-decafluoro-3-methoxy-4-trifluoromethyl-pentane (HFE-7300) was added to the list of negligibly reactive compounds excluded from the definition of VOM in 35 IAC 211.7150(a).

(i) Incorporation by reference.

(A) Illinois Administrative Code Title 35: Environmental Protection, Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.7150: Volatile Organic Matter (VOM) or Volatile Organic Compound (VOC), Subsection 211.7150(a). Effective January 16, 2008.

(183) On January 24, 2008, the Illinois Environmental Protection Agency submitted a revision to its state implementation plan for the packaging production facility of CP-D Acquisition Company, LLC. The revision changes the source name from Cromwell-Phoenix, Incorporated, to CP-D Acquisition Company, LLC.

(i) Incorporation by reference.

(A) November 20, 2003, Supplemental Opinion and Order of the Illinois Pollution Control Board, AS 03-05, effective November 20, 2003.

(184) On October 23, 2007, the Illinois Environmental Protection Agency submitted revisions to its State implementation plan for the Oxides of Nitrogen (NOX) SIP Call Phase II. The State has submitted revisions to 35 Illinois Administrative Code (Ill. Adm. Code) Parts 211 and 217. The rules pertain to definitions and general provisions, and control of Nitrogen Oxides (NOX), respectively. The rules satisfy the requirements of EPA's NOX SIP Call Phase II Rule (the Phase II Rule).

(i) Incorporation by reference. (A) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Sections: 211.740 Brakehorsepower; 211.1740 Diesel Engine; 211.1920 Emergency or Standby Unit; 211.3300 Lean-burn Engine; and 211.5640 Rich-burn Engine; effective September 25, 2007. (B) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 217: Nitrogen Dioxide Emissions, Subpart A: General Provisions, Sections: 217.101 Measurement Methods; 217.102 Abbreviation and Units; Subpart Q: Stationary Reciprocating Internal Combustion Engines and Turbines, Sections 217.386 Applicability; 217.388 Control and Maintenance Requirements; 217.390 Emissions Averaging Plan; 217.392 Compliance; 217.394 Testing and Monitoring; 217.396 Recordkeeping and Reporting; and 217 Appendix G: Existing Reciprocating Internal Combustion Engines Affected by the NOX SIP Call; effective September 25, 2007.

(ii) Additional material. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 217: Nitrogen Dioxide Emissions, Subpart A: General Provisions, Section 217.104 Incorporation by Reference; effective September 25, 2007.

(185) On December 7, 2009, Illinois submitted a rule for the sunset of the provisions of 35 IAC 217 Subpart W, regulating electric generating unit participation in the NOX Budget Trading Program, since these provisions have been superseded by provisions established pursuant to the Clean Air Interstate Rule.

(i) Incorporation by reference. The Illinois rule at 35 IAC 217.751, entitled “Sunset Provisions,” submitted on December 7, 2009, effective on November 2, 2009, is incorporated by reference.

(186) On July 17, 2009, Illinois submitted amendments to its pharmaceutical manufacturing rules for approval into its state implementation plan. These amendments consist of a site-specific rulemaking for certain of Abbott Laboratories' (Abbott) tunnel dryers and fluid bed dryers.

(i) Incorporation by reference.

(A) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart T: Pharmaceutical Manufacturing, Section: 218.480 Applicability, effective August 26, 2008.

(ii) Additional material.

(A) Letter from Laurel L. Kroack, Illinois Environmental Protection Agency, to Cheryl Newton, EPA, dated May 12, 2010, with attachments, that establishes how compliance with Abbott's 20.6 tons VOC per year limit is determined as well as Abbott's recordkeeping requirements.

(187) On October 25, 2010, Illinois submitted revised regulations that are consistent with 40 CFR 51.100(s)(1), as amended by 74 FR 3437. The compounds propylene carbonate and dimethyl were added to the list of negligibly reactive compounds excluded from the definition of VOC in 35 IAC 211.7150(a).

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection, Part 211: Definitions and General Provisions, Section 211.7150: Volatile Organic Matter (VOM) or Volatile Organic Compound (VOC), Subsection 211.7150(a). Effective January 11, 2010.

(188) On November 8, 2010, the Illinois Environmental Protection Agency submitted a revision to its state implementation plan. The revision to the SIP allows an adjusted standard to the general rule, Use of Organic Material Rule, known as the eight pound per hour (8 lb/hr) rule, for volatile organic matter, for Royal Fiberglass Pools, Inc. manufacturing facility located in Dix, Illinois. The adjusted standard is that 35 Ill. Adm. Code 217.301 does not apply to VOM emissions from Royal's Dix, Illinois facility. The facility is subject to emission limit requirements set forth in the MACT under 40 CFR 63 subpart WWWW finalized in 68 FR 19402, April 21, 2003.

(i) Incorporation by reference. (A) February 18, 2010, Opinion and Order of the Illinois Pollution Control Board, AS-09-04, effective February 18, 2010.

(189) On July 29, 2010, September 16, 2011 and September 29, 2011 Illinois submitted VOM RACT rules for the Chicago and Metro-East St. Louis 8-hour ozone nonattainment areas. These rules are consistent with the Control Technique Guideline documents issued by EPA in 2006, 2007 and 2008 and satisfy the RACT requirements of the Act. On February 28, 2011, Illinois EPA submitted a confirmation that the sewage treatment plant exemption in Subpart TT of Parts 218 and 219 does not apply to industrial wastewater. This clarification clearly establishes that VOM emissions from major non-CTG industrial wastewater operations are regulated by Subpart TT.

(i) Incorporation by reference. The following sections of Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, are incorporated by reference:

(A) Part 211: Definitions and General Provisions, Sections 211.1000, 211.1745, 211.1878, 211.1885, 211.2359, 211.2368, 211.2615, 211.2830, 211.2840, 211.2965, 211.3215, 211.3305, 211.3555, 211.3705, 211.3707, 211.4065, 211.5335, 211.5535, 211.5585, 211.5860, 211.5875, 211.5885, 211.6405, 211.6425, 211.6535, 211.7290; effective June 25, 2010.

(B) Part 211: Definitions and General Provisions, Sections 211.101, 211.102, 211.200, 211.233, 211.235, 211.260, 211.481, 211.492, 211.540, 211.715, 211.735, 211.820, 211.825, 211.880, 211.954, 211.965, 211.1128, 211.1455, 211.1560, 211.1565, 211.1655, 211.1700, 211.1872, 211.1876, 211.1877, 211.1880, 211.1882, 211.1883, 211.2040, 211.2055, 211.2210, 211.2310, 211.2320, 211.2360, 211.2369, 211.2415, 211.2525, 211.2622, 211.2825, 211.2955, 211.2956, 211.2958, 211.2960, 211.2980, 211.3095, 211.3120, 211.3240, 211.3505, 211.3665, 211.3760, 211.3775, 211.3785, 211.3820, 211.3925, 211.3961, 211.3966, 211.3967, 211.3968, 211.3969, 211.3975, 211.4052, 211.4080, 211.4220, 211.4285, 211.4455, 211.4540, 211.4735, 211.4760, 211.4765, 211.4768, 211.4769, 211.4895, 211.4900, 211.5012, 211.5061, 211.5062, 211.5075, 211.5090, 211.5400, 211.5520, 211.5550, 211.5800, 211.5890, 211.5985, 211.5987, 211.6012, 211.6015, 211.6017, 211.6020, 211.6063, 211.6065, 211.6400, 211.6427, 211.6460, 211.6585, 211.6640, 211.6670, 211.6690, 211.6720, 211.6740, 211.6780, 211.6825, 211.6885, 211.7220, 211.7240; effective September 14, 2010.

(C) Part 211: Definitions and General Provisions, Sections 211.493, 211.2200, 211.2358, 211.2800, 211.3985, 211.4460, 211.5140, 211.6587, 211.6635; effective July 27, 2011.

(D) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart F: Coating Operations, Section 218.218; effective March 23, 2010.

(E) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart E: Solvent Cleaning, Section 218.181, Subpart H: Printing and Publishing, Sections 218.403, 218.405, 218.406, 218.407, 218.408, 218.410, 218.412, 218.413, 218.416; effective June 25, 2010.

(F) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart A: General Provisions, Sections 218.106, 218.112, Subpart F: Coating Operations, Sections 218.205, 218.208, 218.210, 218.212, 218.219, Subpart II: Fiberglass Boat Manufacturing Materials, Section 218.890, Subpart JJ: Miscellaneous Industrial Adhesives, Section 218.900; effective September 14, 2010.

(G) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart A: General Provisions, Section 218.105, Subpart E: Solvent Cleaning, Section 218.187, Subpart F: Coating Operations, Sections 218.204, 218.207, 218.211, 218.217, Subpart H: Printing and Publishing, Sections 218.401, 218.402, 218.404, 218.409, 218.411, 218.415, 218.417, Subpart II: Fiberglass Boat Manufacturing Materials, Sections 218.891, 218.892, 218.894, Subpart JJ: Miscellaneous Industrial Adhesives, Sections 218.901, 218.902, 218.903, 218.904; effective July 27, 2011.

(H) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart F: Coating Operations, Section 219.218; effective March 23, 2010.

(I) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart E: Solvent Cleaning, Section 219.181, Subpart H: Printing and Publishing, Sections 219.402, 219.403, 219.405, 219.406, 219.407, 219.408, 219.410, 219.412, 219.413, 219.416; effective June 25, 2010.

(J) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart A: General Provisions, Sections 219.106, 219.112, Subpart F: Coating Operations, Sections 219.205, 219.208, 219.210, 219.212, 219.219, Subpart II: Fiberglass Boat Manufacturing Materials, Section 219.890, Subpart JJ: Miscellaneous Industrial Adhesives, Section 219.900; effective September 14, 2010.

(K) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart A: General Provisions, Section 219.105, Subpart E: Solvent Cleaning, Section 219.187, Subpart F: Coating Operations, Sections 219.204, 219.207, 219.211, 219.217, Subpart H: Printing and Publishing, Sections 219.401, 219.404, 219.409, 219.411, 219.415, 219.417, Subpart II: Fiberglass Boat Manufacturing Materials, Sections 219.891, 219.892, 219.894, Subpart JJ: Miscellaneous Industrial Adhesives, Sections 219.901, 219.902, 219.903, 219.904; effective July 27, 2011.

(ii) Additional material. On February 28, 2011, Illinois EPA submitted an email confirmation that the sewage treatment plant exemption in Subpart TT of Parts 218 and 219 does not apply to industrial wastewater.

(190) On June 10, 2011, the Illinois Environmental Protection Agency submitted a revision to its state implementation plan. The revision to the SIP allows an adjusted standard to the general rule, Use of Organic Material Rule, known as the eight pound per hour (8 lb/hr) rule, for volatile organic matter, for Leisure Properties LLC/D/B/A Crownline Boats manufacturing facility located in West Frankfort, Illinois. The adjusted standard is that the facility takes an alternative standard of the emission limit requirements set forth in the MACT under 40 CFR part 63 subpart VVVV as published in 40 CFR Part 63 (§ 63.1200 to end) revised as of July 1, 2002.

(i) Incorporation by reference.

(A) July 22, 2004, Opinion and Order of the Illinois Pollution Control Board, AS-04-01, (identified in error as July 22, 2002 in the document heading), effective July 22, 2004.

(ii) Additional material.

(A) Letter from Laurel L. Kroack, Illinois Environmental Protection Agency, to Cheryl Newton, EPA, dated September 2, 2011, identifying that due to an ownership change to Crownline Boats, the Board transferred the adjusted standard to Leisure Properties LLC D/B/A Crownline Boats, which is the successor to Crownline Boats, by Board order AS04-l, effective October 7, 2010.

(191) On September 14, 2012, Illinois submitted an amendment to its State Implementation Plan at 35 Illinois Administrative Code Part 223, which adds new consumer product categories and VOC limits for these products in Subpart B, and amends Subpart C to clarify applicability. 35 IAC Part 223 limits the amount of volatile organic compounds from consumer products and architectural and industrial maintenance coatings.

(i) Incorporation by reference.

(A) Illinois Administrative Code; Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter c: Emission Standards and Limitation for Stationary Sources; Part 223: Standards and Limitations for Organic material Emissions for Area Sources, effective May 4, 2012.

(B) Reserved.

(192) On June 24, 2011, Laurel Kroack, Illinois Environmental Protection Agency, submitted Illinois' regional haze plan to Cheryl Newton, Region 5, EPA. This plan includes a long-term strategy with emission limits for mandating emission reductions equivalent to the reductions from implementing best available retrofit technology and with emission reductions to provide Illinois' contribution toward achievement of reasonable progress goals at Class I areas affected by Illinois. The plan specifically includes regulations establishing Multi-Pollutant Standards and Combined Pollutant Standards, along with letters from the affected electric utilities establishing the applicability and enforceability of the option that includes sulfur dioxide and nitrogen oxide emission limits. The plan also includes permits establishing sulfur dioxide and nitrogen oxide emission limits for three additional electric generating plants and two consent decrees establishing sulfur dioxide and nitrogen oxide emission limits for two refineries.

(i) Incorporation by reference.

(A) The following sections of Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 225, Control of Emissions from Large Combustion Sources, published at 33 IL Reg 10427, effective June 26, 2009, are incorporated by reference:

(1) Subpart B: Control Of Mercury Emissions From Coal-Fired Electric Generating Units, Section 225.233 Multi-Pollutant Standards (MPS), only subsections (a), (b), (e), and (g), Section 225.291 Combined Pollutant Standard: Purpose, Section 225.292 Applicability of the Combined Pollutant Standard, Section 225.293 Combined Pollutant Standard: Notice of Intent, Section 225.295 Combined Pollutant Standard: Emissions standards for NOX and SO2, and Section 225.296 Combined Pollutant Standard: Control Technology Requirements for NOX, SO2, and PM Emissions, except for 225.296(d).

(2) Section 225.Appendix A Specified EGUs for Purposes of the CPS (Midwest Generation's Coal-Fired Boilers as of July 1, 2006).

(B) Joint Construction and Operating Permit: Application Number 09090046, Issued on June 23, 2011, to City Water, Light & Power, City of Springfield.

(C) Joint Construction and Operating Permit: Application Number 09050022, Issued on June 24, 2011, to Kincaid Generation, LLC.

(ii) Additional material.

(A) Letter from Guy Gorney, Midwest Generation to Dave Bloomberg, Illinois EPA, dated December 27, 2007, choosing to be subject to provisions of the Multi-Pollutant Standards that include emission limits for sulfur dioxide and nitrogen oxides.

(B) Letter from R. Alan Kelley, Ameren, to Jim Ross, Illinois EPA, dated December 27, 2007, choosing to be subject to provisions of the Combined Pollutant Standards that include emission limits for sulfur dioxide and nitrogen oxides.

(C) Letter from Keith A. McFarland, Dynegy, to Raymond Pilapil, Illinois EPA, dated November 26, 2007, choosing to be subject to provisions of the Combined Pollutant Standards that include emission limits for sulfur dioxide and nitrogen oxides.

(193) On June 20, 2012, Illinois submitted an Adjusted Standard for the Greif Packaging, LLC facility located at 5 S 220 Frontenac Road in Naperville, DuPage County. This adjustment to the Standard at 35 Ill. Adm. Code 218.986(a) for Greif's fiber drum manufacturing facility replaces the VOM capture and control requirements in 35 Ill. Adm. Code 218.986(a) with the control requirements in the Illinois Pollution Control Board's April 5, 2012 Order.

(i) Incorporation by reference.

(A) April 5, 2012 Opinion and Order of the Illinois Pollution Control Board (AS 2011-01), effective April 5, 2012.

(194) On November 14, 2011, the Illinois Environmental Protection Agency (Illinois EPA) submitted amendments to 35 Illinois Administrative Code 218.208 and 219.208. These sections add a “small container exemption” for pleasure craft surface coating operations in the Chicago and Metro-East St. Louis 8-hour ozone nonattainment areas. These exemptions are consistent with EPA volatile organic compound (VOC) reasonably available control technology (RACT) policy.

(i) Incorporation by reference. The following sections of Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter 1: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, are incorporated by reference.

(A) Part 218: Organic Material Emission Standards and Limitations for the Chicago Area, Subpart F: Coating Operations, Section 218.208 Exemptions From Emission Limitations; effective October 25, 2011.

(B) Part 219: Organic Material Emission Standards and Limitations for the Metro East Area, Subpart F: Coating Operations, Section 219.208 Exemptions From Emission Limitations; effective October 25, 2011.

(195) On June 20, 2012, Illinois submitted an amendment to its State Implementation Plan at 35 Illinois Administrative Code part 243, which updates National Ambient Air Quality Standards for ozone, lead, and particulate matter while correcting various errors in the plan.

(i) Incorporation by reference. Illinois Administrative Code; Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter l: Air Quality Standards And Episodes; Part 243: Air Quality Standards; Sections 243.101 Definitions, 243.104 Nondegradation, 243.107 Reference Conditions, 243.108 Incorporations by Reference, 243.120 PM10 and PM2.5, 243.122 Sulfur Oxides (Sulfur Dioxide), 243.125 8-Hour Ozone, and 243.126 Lead; effective October 25, 2011.

(196) On April 11, 2013, Illinois submitted a revision to 35 IAC Part 254, Annual Emissions Report. The revision amends the applicability provisions as they relate to greenhouse gases.

(i) Incorporation by reference.

Illinois Administrative Code Title 35: Environmental Protection, Subtitle B: Air Pollution; Chapter II: Environmental Protection Agency; Part 254: Annual Emission Report, Section 254.102: Applicability, effective April 20, 2012.

(197) On July 3, 2013, Illinois submitted revised regulations that are consistent with 40 CFR 51.100(s)(1). The compound trans-1,3,3,3-tetra-flouropropene (HFO-1234ze) was added to the list of negligibly reactive compounds excluded from the definition of “Volatile Organic Material (VOM)” or “Volatile Organic Compound (VOC)” at 35 IAC 211.7150(a).

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection; Subtitle B: Air Pollution; ChapterI: Pollution Control Board; Subchapter C: Emission Standards and Limitations for Stationary Sources; Part 211: Definitions and General Provisions, Section 211.7150: Volatile Organic Matter (VOM) or Volatile Organic Compound (VOC), Subsection 211.7150(a). Effective February 4, 2013.

(198) On January 9, 2014, Illinois submitted modifications to its Federally Enforceable State Operating Permits rules as a revision to the state implementation plan. The revision extends the maximum permit term of Federally Enforceable State Operating Permits from five years to ten years.

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter a: Permits and General Provisions; Part 201: Permits and General Provisions; Subpart D: Permit Applications and Review Process; Section 201.162: Duration; Subsection 201.162(a). Effective December 1, 2010.

(199) On January 8, 2014, the Illinois Environmental Protection Agency submitted a revision to its state implementation plan. The revision to the SIP substitutes Latham Pool Products, d/b/a Viking Pools, for Royal Fiberglass Pools, Inc. as the holder of the adjusted standard to the general rule, Use of Organic Material Rule, known as the eight pound per hour (8 lb/hr) rule, for volatile organic matter that was granted to Royal Fiberglass Pools, Inc. manufacturing facility located in Dix, Illinois on February 18, 2010 by the Illinois Pollution Control Board. The adjusted standard affected by the name change provides that 35 Ill. Adm. Code 215.301 does not apply to VOM emissions from Viking Pools fiberglass pool manufacturing facility in Dix, Illinois. The facility is subject to emission limit requirements set forth in the National Emissions Standards for Hazardous Air Pollutants for Reinforced Plastic Composites Production at 40 CFR 63, subpart WWWW, April 21, 2003.

(i) Incorporation by reference.

(A) Supplemental Opinion and Order of the Illinois Pollution Control Board, AS 09-4, effective September 5, 2013.

(200) On November 29, 2012, the Illinois Environmental Protection Agency submitted a request to revise Illinois' vehicle inspection and maintenance (I/M) program to reflect changes that have been made to the program since EPA fully approved the I/M program on February 22, 1999.

(i) Incorporation by reference.

(A) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter k: Emission Standards and Limitations for Mobile Sources, Part 240 Mobile Sources. Effective February 1, 2012.

(B) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter II: Environmental Protection Agency, Part 276 Procedures to be Followed in the Performance of Inspections of Motor Vehicle Emissions. Effective January 30, 2012.

(ii) Other materials.

(A) Transmittal letter dated November 29, 2012.

(B) Vehicle Emissions Inspection Law of 2005, as amended, 625 ILCS 5/13C (Public Act 94-526 enacted on August 10, 2005; Public Act 94-848 enacted on June 9, 2006; Public Act 97-106, enacted on July 14, 2011).

(C) Listing of Chicago and Metro-East St. Louis NAA Facility Closures (July 2012).

(201) On March 19, 2013, the Illinois Environmental Protection Agency submitted a request to repeal the gasoline volatility standards at 35 Ill. Adm. Code 215.585, 218.585, and 219.585, including other related revisions to 35 Ill. Adm. Code Parts 211, 215, 218, and 219, to revise the motor vehicle refinishing equipment specifications at 35 Ill. Adm. Code 218.784 and 219.784, and to repeal the motor vehicle refinishing registration requirements at 35 Ill. Adm. Code 218.792 and 219.792.

(i) Incorporation by reference.

(A) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211, Definitions and General Provisions, Sections 211.101 Incorporations by Reference, 211.2870 Heavy Liquid, and 211.5510 Reid Vapor Pressure. Effective January 28, 2013.

(B) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 215, Organic Material Emission Standards and Limitations, Sections 215.104 Definitions, and 215.105 Incorporation by Reference. Effective January 28, 2013.

(C) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 218, Organic Material Emission Standards and Limitations for the Chicago Area, Sections 218.112 Incorporations by Reference, 218.128 Monitoring VOL Operations, and 218.784 Equipment Specifications. Effective January 28, 2013.

(D) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 219, Organic Material Emission Standards and Limitations for the Metro East Area, Sections 219.112 Incorporations by Reference, 219.128 Monitoring VOL Operations, and 219.784 Equipment Specifications. Effective January 28, 2013.

(202) On June 10, 2014, Illinois submitted revised regulations that are consistent with 40 CFR 51.100(s)(1). The compounds (difluoromethoxy) (difluoro)methane (CHF2OCHF2 or HFE-134), bis(difluoromethoxy) (difluoro)methane (CHF2OCF2OCHF2 or HFE-236cal2), 1-(difluoromethoxy)-2-[(difluoromethoxy) ((difluoro)methoxy]-1,1,2,2-tetrafluoroethane (CHF2OCF2OCF2CF2OCHF2 or HFE-43-10pccc), 1,2-bis(difluoromethoxy)-1,1,2,2-tetrafluoroethane (CHF2OCF2CF2OCHF2 or HFE-338pcc13), and trans 1-chloro-3,3,3-trifluoroprop-1-ene (CF3CHCHCl) were added to the list of negligibly reactive compounds excluded from the definition of “Volatile Organic Material (VOM)” or “Volatile Organic Compound (VOC)” at 35 IAC 211.7150(a).

(i) Incorporation by reference.

Illinois Administrative Code Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter c: Emission Standards and Limitations for Stationary Sources; Part 211: Definitions and General Provisions; Subpart B: Definitions; Section 211.7150: Volatile Organic Material (VOM) or Volatile Organic Compound (VOC), effective November 27, 2013.

(203) On January 17, 2013, the Illinois Environmental Protection Agency submitted a request to phase out Stage II vapor recovery standards at 35 Ill. Adm. Code 218.586 and to make other related revisions to 35 Ill. Adm. Code Parts 201, 218, and 219.

(i) Incorporation by reference.

(A) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter a: Permits and General Provisions, Part 201, Permits and General Provisions, Subpart C: Prohibitions, Section 201.146, Exemptions from State Permit Requirements, and Subpart K: Records and Reports, Section 201.302, Reports, effective December 23, 2013.

(B) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 218, Organic Material Emission Standards and Limitations for the Chicago Area, Subpart A: General Provisions, Section 218.112, Incorporations by Reference, Subpart Y: Gasoline Distribution, Section 218.583, Gasoline Dispensing Operations—Storage Tank Filling Operations and Section 218.586, Gasoline Dispensing Operations—Motor Vehicle Fueling Operations, effective December 23, 2013.

(C) Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 219, Organic Material Emission Standards and Limitations for the Metro East Area, Subpart A: General Provisions, Section 219.105, Test Methods and Procedures, and Section 219.112, Incorporations by Reference, Subpart Y: Gasoline Distribution, Section 219.583, Gasoline Dispensing Operations—Storage Tank Filling Operations, effective December 23, 2013.

(204) On December 2, 2013, Illinois submitted an amendment to its State Implementation Plan at 35 Illinois Administrative Code part 243, which updates Illinois air quality standards to reflect National Ambient Air Quality Standards for sulfur dioxide, ozone, nitrogen dioxide, lead, fine particulate matter, particulate matter, and carbon monoxide and incorporates Federal test procedures for these pollutants.

(i) Incorporation by reference. Illinois Administrative Code Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter l: Air Quality Standards And Episodes; Part 243: Air Quality Standards; Sections 243.101 Definitions, 243.102 Scope, 243.103 Applicability, 243.105 Air Quality Monitoring Data Influenced by Exceptional Events, 243.107 Reference Conditions, 243.108 Incorporations by Reference, 243.120 PM10 and PM2.5, 243.122 Sulfur Oxides (Sulfur Dioxide), 243.123 Carbon Monoxide, 243.124 Nitrogen Oxides (Nitrogen Dioxide as Indicator), 243.125 Ozone, 243.126 Lead, and 243.TABLE A Schedule of Exceptional Event Flagging and Documentation Submission for New or Revised NAAQS, effective July 29, 2013.

(205) On May 16, 2013, and August 18, 2014, Illinois submitted variances to its regional haze state implementation plan affecting the following Midwest Generation, LLC facilities: Crawford Generating Station (Cook County), Joliet Generating Station (Will County), Powerton Generating Station (Tazewell County), Waukegan Generating Station (Lake County), and Will County Generating Station (Will County).

(i) Incorporation by Reference. (A) Illinois Pollution Control Board Order PCB 12-121, adopted on August 23, 2012; Certificate of Acceptance, dated August 24, 2012, filed with the Illinois Pollution Control Board Clerk's Office August 27, 2012.

(B) Illinois Pollution Control Board Order PCB 13-24, adopted on April 4, 2013; Certificate of Acceptance, dated May 16, 2013, filed with the Illinois Pollution Control Board Clerk's Office May 17, 2013.

(206) On December 18, 2014, the state submitted a proposed revision to the Illinois SIP updating the definition of Volatile Organic Material (VOM) or Volatile Organic Compound (VOC) to exclude the chemical compound 2,3,3,3-tetrafluoropropene (HFO-1234yf), along with minor administrative revisions.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emission Standards and Limitations for Stationary Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.7150 Volatile Organic Material (VOM) or Volatile Organic Compounds (VOC), effective June 9, 2014.

(207) On September 3, 2014, Illinois submitted a variance to its regional haze state implementation plan affecting the electrical generating units (EGUs) included in the Ameren Multi-Pollutant Standard Group (Ameren MPS Group). The Ameren MPS Group consists of five facilities owned by Illinois Power Holdings, LLC (IPH) and two facilities owned by AmerenEnergy Medina Valley Cogen, LLC (Medina Valley). The IPH facilities included in the Ameren MPS Group and subject to the variance include: Coffeen Energy Center (Montgomery County), Duck Creek Energy Center (Fulton County), E.D. Edwards Energy Center (Peoria County), Joppa Energy Center (Massac County), and Newton Energy Center (Jasper County). The Medina Valley facilities included in the Ameren MPS Group and subject to the variance are the Meredosia Energy Center (Morgan County) and the Hutsonville Energy Center (Crawford County).

(i) Incorporation by reference.

(A) Illinois Pollution Control Board Order PCB 14-10, adopted on November 21, 2013; Certificate of Acceptance, filed with the Illinois Pollution Control Board Clerk's Office December 20, 2013.

(208) On December 18, 2014, and April 23, 2015, Illinois submitted amendments to its State Implementation Plan at 35 Illinois Administrative Code part 243, which updates Illinois air quality standards to reflect National Ambient Air Quality Standards promulgated by EPA through December 17, 2013, and incorporates Federal test procedures for these pollutants.

(i) Incorporation by Reference. (A) Illinois Administrative Code Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter I: Air Quality Standards And Episodes; Part 243: Air Quality Standards; Sections 243.107 Reference Conditions, 243.120 p.m.10 and PM2.5, 243.122 Sulfur Oxides (Sulfur Dioxide), and 243.Table A Schedule of Exceptional Event Flagging and Documentation Submission for New or Revised NAAQS, effective November 27, 2013.

(B) Illinois Administrative Code Title 35: Environmental Protection; Subtitle B: Air Pollution; Chapter I: Pollution Control Board; Subchapter I: Air Quality Standards And Episodes; Part 243: Air Quality Standards; Section 243.108 Incorporation by Reference, effective June 9, 2014.

(209) On August 9, 2016, the state submitted a proposed revision to the Illinois SIP updating the definition of Volatile Organic Material (VOM) or Volatile Organic Compound (VOC) to exclude the chemical compound 2-amino-2-methyl-1-propanol (AMP), along with minor administrative revisions.

(i) Incorporation by reference. Illinois Administrative Code, Title 35: Environmental Protection, Subtitle B: Air Pollution, Chapter I: Pollution Control Board, Subchapter c: Emissions Standards and Limitations for Station Sources, Part 211: Definitions and General Provisions, Subpart B: Definitions, Section 211.7150 Volatile Organic Material (VOM) or Volatile Organic Compounds (VOC), effective March 24, 2015.

[37 FR 10862, May 31, 1972. Redesignated and amended at 82 FR 30638, June 30, 2017] Editorial Note:For Federal Register citations affecting § 52.750, see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume and at www.govinfo.gov.