Collapse to view only § 430.53 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

§ 430.50 - Applicability; description of the papergrade sulfite subcategory.

The provisions of this subpart apply to discharges resulting from the: Integrated production of pulp and paper at papergrade sulfite mills, where blow pit pulp washing techniques are used; and the integrated production of pulp and paper at papergrade sulfite mills where vacuum or pressure drums are used to wash pulp.

§ 430.51 - Specialized definitions.

(a) Except as provided in paragraphs (b) and (c) of this section, the general definitions, abbreviations, and methods of analysis set forth in 40 CFR part 401 and § 430.01 of this part apply to this subpart.

(b) Sulfite cooking liquor is defined as bisulfite cooking liquor when the pH of the liquor is between 3.0 and 6.0 and as acid sulfite cooking liquor when the pH is less than 3.0.

(c) For this subpart, the segments for the papergrade sulfite subcategory are defined as follows:

(1) The calcium-, magnesium-, or sodium-based sulfite pulp segment consists of papergrade sulfite mills where pulp and paper are produced using an acidic cooking liquor of calcium, magnesium, or sodium sulfite, unless those mills are specialty grade sulfite mills;

(2) The ammonium-based sulfite pulp segment consists of papergrade sulfite mills where pulp and paper are produced using an acidic cooking liquor of ammonium sulfite, unless those mills are specialty grade sulfite mills;

(3) The specialty grade sulfite pulp segment consists of those papergrade sulfite mills where a significant portion of production is characterized by pulp with a high percentage of alpha cellulose and high brightness sufficent to produce end products such as plastic molding compounds, saturating and laminating products, and photographic papers. The specialty grade segment also includes those mills where a major portion of production is 91 ISO brightness and above.

§ 430.52 -

(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Subpart E

[Bisulfite liquor/surface condensers; BPT effluent limitations for papergrade sulfite facilities where blow pit washing techniques are used]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD531.816.559.30 TSS43.9523.6512.99 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Subpart E

[Bisulfite liquor/barometric condensers; BPT effluent limitations for papergrade sulfite facilities where blow pit washing techniques are used]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD534.718.0510.14 TSS52.228.115.44 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Subpart E

[Acid sulfite liquor/surface condensers; BPT effluent limitations for papergrade sulfite facilities where blow pit washing techniques are used]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD532.316.89.44 TSS43.9523.6512.99 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Subpart E

[Acid sulfite liquor/barometric condensers; BPT effluent limitations for papergrade sulfite facilities where blow pit washing techniques are used]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD535.5518.510.39 TSS52.228.115.44 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Subpart E

[Bisulfite liquor/surface condensers; BPT effluent limitations for papergrade sulfite facilities where vacuum or pressure drums are used to wash pulp]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD526.713.97.81 TSS43.9523.6512.99 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Note: Limitations above do not apply to mills using continuous digesters.

Subpart E

[Bisulfite liquor/barometric condensers; BPT effluent limitations for papergrade sulfite facilities where vacuum or pressure drums are used to wash pulp]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD529.415.38.60 TSS52.228.115.44 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Note: Limitations above do not apply to mills using continuous digesters.

Subpart E

[Acid sulfite liquor/surface condensers; BPT effluent limitations for papergrade sulfite facilities where vacuum or pressure drums are used to wash pulp]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD529.7515.58.71 TSS43.9523.6512.99 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Note: Limitations above do not apply to mills using continuous digesters.

Subpart E

[Acid sulfite liquor/barometric condensers; BPT effluent limitations for papergrade sulfite facilities where vacuum or pressure drums are used to wash pulp]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD532.516.99.49 TSS52.228.115.44 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Note: Limitations above do not apply to mills using continuous digesters.

Subpart E

[Continuous digesters; BPT effluent limitations for papergrade sulfite facilities where vacuum or pressure drums are used to wash pulp]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD538.1519.8511.15 TSS53.7528.9515.91 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, resulting from the use of wet barking operations, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calculated using the proportion of the mill's total production due to use of logs which are subject to such operations:

Subpart E

[BPT effluent limitations for papergrade sulfite facilities where blow pit washing techniques are used]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD52.71.450.80 TSS7.53.952.19 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Subpart E

[BPT effluent limitations for papergrade sulfite facilities where vacuum or pressure drums are used to wash pulp]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD53.051.60.90 TSS7.53.952.19 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

(c) The following limitations establish the quantity or quality of pollutants or pollutant parameters, controlled by this section, resulting from the use of log washing or chip washing operations, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calculated using the proportion of the mill's total production due to use of logs and/or chips which are subject to such operations:

Subpart E

[BPT effluent limitations for papergrade sulfite facilities where blow pit washing techniques are used]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD50.150.10.05 TSS2.551.350.75 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Subpart E

[BPT effluent limitations for papergrade sulfite facilities where vacuum or pressure drums are used to wash pulp]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual average) Maximum for any 1 day Average of daily values for 30 consecutive days BOD50.350.20.1 TSS2.551.350.75 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

(d) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, resulting from the use of log flumes or log ponds, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calculated using the proportion of the mill's total production due to use of logs which are subject to such operations:

Subpart E

[BPT effluent limitations for papergrade sulfite facilities where blow pit washing techniques are used]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD50.350.20.1 TSS1.70.90.5 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

Subpart E

[BPT effluent limitations for papergrade sulfite facilities where vacuum or pressure drums are used to wash pulp]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days BOD50.70.350.2 TSS1.700.90.5 pH( 1)( 1)( 1)

1 Within the range of 5.0 to 9.0 at all times.

§ 430.53 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). The limitations shall be the same as those specified for conventional pollutants in § 430.52 of this subpart for the best practicable control technology currently available (BCT).

§ 430.54 - Effluent limitations representing the degree of effluent reduction attainable by the application of best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

(a)(1) The following effluent limitations apply to all dischargers in the calcium-, magnesium-, or sodium-based sulfite pulp segment:

Subpart E

[Production of Calcium-, Magnesium-, or Sodium-based Sulfite Pulps]

Pollutant or pollutant property BAT effluent limitations Continuous dischargers Non-continuous dischargers Maximum for any 1 day Monthly average Maximum for any 1 day Annual average kg/kkg (or pounds per 1,000 lb) of product AOX<ML a( b)<ML a( b) COD( c)( c)( c)( c)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

c [Reserved]

(2)(i) The following effluent limitations apply to all dischargers in the ammonium-based sulfite pulp segment:

Subpart E—Production of Ammonium-Based Sulfite Pulps

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Monthly average TCDD a<ML b( c) TCDF a<ML b( c) Chloroform a( d)( c) Trichlorosyringol a<ML b( c) 3,4,5-trichlorocatechol a<ML b( c) 3,4,6-trichlorocatechol a<ML b( c) 3,4,5-trichloroguaiacol a<ML b( c) 3,4,6-trichloroguaiacol a<ML b( c) 4,5,6-trichloroguaiacol a<ML b( c) 2,4,5-trichlorophenol a<ML b( c) 2,4,6-trichlorophenol a<ML b( c) Tetrachlorocatechol a<ML b( c) Tetrachloroguaiacol a<ML b( c) 2,3,4,6-tetrachlorophenol a<ML b( c) Pentachlorophenol a<ML b( c)
Continuous dischargers Non-continuous
dischargers
Maximum for any 1 day Monthly
average
Maximum for any 1 day Annual
average
kg/kkg (or pounds per 1,000 lb) of product AOX( d)( d)( d)( d) COD( d)( d)( d)( d)

a These limitations do not apply with respect to fiber lines that use a TCF bleaching process as disclosed by the discharger in its permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22.

b “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

c This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

d [Reserved]

(ii) The following effluent limitations apply to all dischargers in the ammonium-based sulfite pulp segment with respect to each fiber line that uses exclusively TCF bleaching processes, as disclosed by the discharger in its NPDES permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22:

Subpart E—Production of Ammonium-Based Sulfite Pulps

Pollutant or pollutant property BAT effluent limitations (TCF) Continuous dischargers Non-continuous dischargers Maximum for any 1 day Monthly average Maximum for any 1 day Annual average kg/kkg (or pounds per 1,000 lb) of product AOX<ML a( b)<ML a( b) COD( c)( c)( c)( c)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

c [Reserved]

(3)(i) The following effluent limitations apply to all dischargers in the specialty grade pulp segment:

Subpart E—Production of Specialty Grade Sulfite Pulps

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Monthly Average TCDD a<ML b( c) TCDF a<ML b( c) Chloroform a( d)( c) Trichlorosyringol a<ML b( c) 3,4,5-trichlorocatechol a<ML b( c) 3,4,6-trichlorocatechol a<ML b( c) 3,4,5-trichloroguaiacol a<ML b( c) 3,4,6-trichloroguaiacol a<ML b( c) 4,5,6-trichloroguaiacol a<ML b( c) 2,4,5-trichlorophenol a<ML b( c) 2,4,6-trichlorophenol a<ML b( c) Tetrachlorocatechol a<ML b( c) Tetrachloroguaiacol a<ML b( c) 2,3,4,6-tetrachlorophenol a<ML b( c) Pentachlorophenol a<ML b( c)
Continuous dischargers Non-continuous
dischargers
Maximum for any 1 day Monthly average Maximum for any 1 day Annual
average
kg/kkg (or pounds per 1,000 lb) of product AOX( d)( d)( d)( d) COD( d)( d)( d)( d)

a These limitations do not apply with respect to fiber lines that use a TCF bleaching process as disclosed by the discharger in its permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22.

b “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

c This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

d [Reserved]

(ii) The following effluent limitations apply to dischargers in the specialty grade pulp segment with respect to each fiber line that uses exclusively TCF bleaching processes, as disclosed by the discharger in its NPDES permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22:

Subpart E—Production of Specialty Grade Pulps

Pollutant or pollutant property BAT effluent limitations (TCF) Continuous dischargers Non-continuous dischargers Maximum for any 1 day Monthly average Maximum for any 1 day Annual average kg/kkg (or pounds per 1,000 lb) of product AOX<ML a( b)<ML a( b) COD( c)( c)( c)( c)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

c [Reserved]

(b) The following additional effluent limitations apply to each discharger subject to this section in accordance with the previous subcatgorization scheme unless it certifies to the permitting authority that it is not using these compounds as biocides. Also, for non-continuous dischargers, concentration limitations (mg/l) shall apply. Concentration limitations will only apply to non-continuous dischargers:

Subpart E

[Supplemental BAT effluent limitations]

Pollutant or pollutant property Maximum for any 1 day kg/kkg (or pounds per 1,000 lb) of product Milligrams/liter Pentachlorophenol0.00058exp(0.017x)((0.011)(12.67)exp(0.017x))/y Trichlorophenol0.0036exp(0.017x)((0.068)(12.67)exp(0.017x))/y x = percent sulfite pulp in final product. y = wastewater discharged in kgal per ton of product.

(c) Pursuant to 40 CFR 122.44(i) and 122.45(h), a discharger must demonstrate compliance with the limitations in paragraphs (a)(2) or (a)(3) of this section, as applicable, by monitoring for all pollutants (except for AOX and COD) at the point where the wastewater containing those pollutants leaves the bleach plant. The permitting authority may impose effluent limitations and/or monitoring requirements on internal wastestreams for any other pollutants covered in this section as appropriate under 40 CFR 122.44(i) and 122.45(h).

§ 430.55 - New source performance standards (NSPS).

New sources subject to this subpart must achieve the following new source performance standards (NSPS), as applicable.

(a) The following standards apply to each new source regardless of when it commenced discharge:

Subpart E

[1982 NSPS]

Pollutant or pollutant
property
Kg/kkg (or pounds per 1,000 lb) of product Continuous dischargers Non-continuous dischargers (annual average) Maximum for any 1 day Average of daily values for 30 consecutive days BOD54.38exp(0.017x)2.36exp(0.017x)Average of daily values for 30 consecutive days divided by 1.91. TSS5.81exp(0.017x)3.03exp(0.017x)Average of daily values for 30 consecutive days divided by 1.90. pH( 1)( 1)( 1) x = percent sulfite pulp in final product

1 Within the range of 5.0 to 9.0 at all times.

(b) The following standards apply with respect to each new source fiber line that commences discharge after June 15, 1998.

(1) The following standards apply to all new sources in the calcium-, magnesium-, or sodium-based sulfite pulp segment:

Subpart E

[Production of Calcium-, Magnesium-, or Sodium-based Sulfite Pulps]

Pollutant or pollutant property NSPS Continuous dischargers Non-continuous dischargers Maximum for any 1 day Monthly average Maximum for any 1 day Annual average kg/kkg (or pounds per 1,000 lb) of product AOX<ML a( b)<ML a( b) COD( c)( c)( c)( c)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

c [Reserved]

(2)(i) The following standards apply to all new sources in the ammonium-based sulfite pulp segment:

Subpart E—Production of Ammonium-based Sulfite Pulps

Pollutant or pollutant property NSPS Maximum for any 1 day Monthly average TCDD a<ML b( c) TCDF a<ML b( c) Chloroform a( d)( d) Trichlorosyringol a<ML b( c) 3,4,5-trichlorocatechol a<ML b( c) 3,4,6-trichlorocatechol a<ML b( c) 3,4,5-trichloroguaiacol a<ML b( c) 3,4,6-trichloroguaiacol a<ML b( c) 4,5,6-trichloroguaiacol a<ML b( c) 2,4,5-trichlorophenol a<ML b( c) 2,4,6-trichlorophenol a<ML b( c) Tetrachlorocatechol a<ML b( c) Tetrachloroguaiacol a<ML b( c) 2,3,4,6-tetrachlorophenol a<ML b( c) Pentachlorophenol a<ML b( c)
Continuous dischargers Non-continuous
dischargers
Maximum for any 1 day Monthly
average
Maximum for any 1 day Annual
average
kg/kkg (or pounds per 1,000 lb) of product AOX( d)( d)( d)( d) COD( d)( d)( d)( d)

a These limitations do not apply with respect to fiber lines that use a TCF bleaching process as disclosed by the discharger in its permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22.

b “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

c This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

d [Reserved]

(ii) The following standards apply to all new sources in the ammonium-based sulfite pulp segment with respect to each fiber line that uses exclusively TCF bleaching processes, as disclosed by the discharger in its NPDES permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22:

Subpart E—Production of Ammonium-based Sulfite Pulps

Pollutant or pollutant property NSPS (TCF) Continuous dischargers Non-continuous dischargers Maximum for any 1 day Monthly average Maximum for any 1 day Annual average kg/kkg (or pounds per 1,000 lb) of product AOX<ML a( b)<ML a( b) COD( c)( c)( c)( c)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

c [Reserved]

(3)(i) The following standards apply to all new sources in the specialty grade sulfite pulp segment:

Subpart E—Production of Specialty Grade Sulfite Pulps

Pollutant or pollutant property NSPS Maximum for any 1 day Monthly average TCDD a<ML b( c) TCDF a<ML b( c) Chloroform a( d)( d) Trichlorosyringol a<ML b( c) 3,4,5-trichlorocatechol a<ML b( c) 3,4,6-trichlorocatechol a<ML b( c) 3,4,5-trichloroguaiacol a<ML b( c) 3,4,6-trichloroguaiacol a<ML b( c) 4,5,6-trichloroguaiacol a<ML b( c) 2,4,5-trichlorophenol a<ML b( c) 2,4,6-trichlorophenol a<ML b( c) Tetrachlorocatechol a<ML b( c) Tetrachloroguaiacol<ML b( c) 2,3,4,6-tetrachlorophenol a<ML b( c) Pentachlorophenol a<ML b( c)
Continuous dischargers Non-continuous
dischargers
Maximum for any 1 day Monthly
average
Maximum for any 1 day Annual
average
kg/kkg (or pounds per 1,000 lb) of product AOX( d)( d)( d)( d) COD( d)( d)( d)( d)

a These limitations do not apply with respect to fiber lines that use a TCF bleaching process as disclosed by the discharger in its permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22.

b “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

c This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

d [Reserved]

(ii) The following standards apply to all new sources within the specialty grade sulfite pulp segment with respect to each fiber line that uses exclusively TCF bleaching processes, as disclosed by the discharger in its NPDES permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22:

Subpart E—Production of Specialty Grade Sulfite Pulps

Pollutant or pollutant property NSPS (TCF) Continuous dischargers Non-continuous dischargers Maximum for any 1 day Monthly average Maximum for any 1 day Annual average kg/kkg (or pounds per 1,000 lb) of product AOX<ML a( b)<ML a( b) COD( c)( c)( c)( c)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, permitting authorities may do so as appropriate.

c [Reserved]

(c) The following standards apply to each new source regardless of when it commenced discharge, unless it certifies to the permitting authority that it is not using these compounds as biocides. Also, for non-continuous dischargers, concentration limitations (mg/l) shall apply. Concentration limitations will only apply to non-continuous dischargers:

Subpart E

[Supplemental NSPS]

Pollutant or pollutant property Maximum for any 1 day kg/kkg (or pounds per 1,000 lb) of product Milligrams/liter Pentachlorophenol0.00058exp(0.017x)((0.015)(9.12)exp(0.017x))/y Trichlorophenol0.0036exp(0.017x)((0.094)(9.12)exp(0.017x))/y x = percent sulfite pulp in final product. y = wastewater discharged in kgal per ton of product.

(d) Pursuant to 40 CFR 122.44(i) and 122.45(h), a discharger must demonstrate compliance with the standards in paragraphs (b)(2) or (b)(3) of this section, as applicable, by monitoring for all pollutants (except for AOX, COD, BOD5, TSS, and pH) at the point where the wastewater containing those pollutants leaves the bleach plant. The permitting authority may impose effluent limitations and/or monitoring requirements on internal wastestreams for any other pollutants covered in this section as appropriate under 40 CFR 122.44(i) and 122.45(h).

§ 430.56 - Pretreatment standards for existing sources (PSES).

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and must achieve the following pretreatment standards for existing sources (PSES).

(a) The following pretreatment standards must be attained on or before April 16, 2001.

(1) The following pretreatment standards apply to all indirect dischargers in the calcium-, magnesium-, or sodium-based sulfite pulp segment:

Subpart E

[Production of Calcium-, Magnesium-, or Sodium-based Sulfite Pulps]

Pollutant or pollutant property PSES Maximum for any 1 day Monthly
average
kg/kkg (or pounds per 1,000 lb) of product AOX<ML a( b)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(2)(i) The following pretreatment standards apply to all indirect dischargers in the ammonium-based sulfite pulp segment:

Subpart E—Production of Ammonium-Based Sulfite Pulps

Pollutant or pollutant property PSES Maximum for any 1 day Monthly average TCDD a<ML b( c) TCDF a<ML b( c) Trichlorosyringol a<ML b( c) 3,4,5-trichlorocatechol a<ML b( c) 3,4,6-trichlorocatechol a<ML b( c) 3,4,5-trichloroguaiacol a<ML b( c) 3,4,6-trichloroguaiacol a<ML b( c) 4,5,6-trichloroguaiacol a<ML b( c) 2,4,5-trichlorophenol a<ML b( c) 2,4,6-trichlorophenol a<ML b( c) Tetrachlorocatechol a<ML b( c) Tetrachloroguaiacol a<ML b( c) 2,3,4,6-tetrachlorophenol a<ML b( c) Pentachlorophenol a<ML b( c)

a These limitations do not apply with respect to fiber lines operated by any indirect discharger that discloses to the pretreatment control authority, at the time it submits the report required under 40 CFR 403.12(b), (d), or (e), that it uses a TCF bleaching process at that fiber line.

b “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

c This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(ii) The following pretreatment standards apply with respect to each new source fiber line operated by an indirect discharger producing ammonium-based sulfite pulps if the indirect discharger discloses to the pretreatment control authority in a report submitted under 40 CFR 403.12(b) that it uses exclusively TCF bleaching processes at that fiber line:

Subpart E—Production of Ammonium-Based Sulfite Pulps

Pollutant or pollutant parameter PSES (TCF) Maximum for any 1 day Monthly
average
AOX<ML a( b)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(3)(i) The following pretreatment standards apply to all indirect dischargers in the specialty grade sulfite pulp segment:

Subpart E—Production of Specialty Grade Sulfite Pulps

Pollutant or pollutant property PSES Maximum for any 1 day Monthly average TCDD a<ML b( c) TCDF a<ML b( c) Trichlorosyringol a<ML b( c) 3,4,5-trichlorocatechol a<ML b( c) 3,4,6-trichlorocatechol a<ML b( c) 3,4,5-trichloroguaiacol a<ML b( c) 3,4,6-trichloroguaiacol a<ML b( c) 4,5,6-trichloroguaiacol a<ML b( c) 2,4,5-trichlorophenol a<ML b( c) 2,4,6-Trichlorophenol a<ML b( c) Tetrachlorocatechol a<ML b( c) Tetrachloroguaiacol a<ML b( c) 2,3,4,6-tetrachlorophenol a<ML b( c) Pentachlorophenol a<ML b( c)

a These limitations do not apply with respect to fiber lines operated by any indirect discharger that discloses to the pretreatment control authority, at the time it submits the report required under 40 CFR 403.12(b), (d), or (e), that it uses a TCF bleaching process at that fiber line.

b “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

c This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(ii) The following pretreatment standards apply with respect to each fiber line operated by an indirect discharger producing specialty grade sulfite pulps if the indirect discharger discloses to the pretreatment control authority in a report submitted under 40 CFR 403.12(b), (d), or (e) that it uses exclusively TCF bleaching processes at that fiber line. These pretreatment standards must be attained on or before April 16, 2001:

Subpart E

Pollutant or pollutant parameter PSES (TCF) Maximum for any 1 day Monthly
average
AOX<ML a( b)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(b) The following pretreatment standards apply to each indirect discharger, in accordance with the previous subcategorization scheme, unless it certifies to the pretreatment control authority that it is not using these compounds as biocides. In cases when POTWs find it necessary to impose mass effluent limitations, equivalent mass limitations are provided as guidance:

Subpart E

Pollutant or pollutant property Supplemental PSES Maximum for any 1 day kg/kkg (or pounds per 1,000 lb) of product Milligrams/liter Pentachlorophenol0.00058exp(0.017x)((0.011)(12.67)exp(0.017x))/y Trichlorophenol0.0043exp(0.017x)((0.082)(12.67)exp(0.017x))/y x = percent sulfite pulp in final product. y = wastewater discharged in kgal per ton of product.

(c) An indirect discharger must demonstrate compliance with the pretreatment standards in paragraphs (a)(2) or (a)(3) of this section, as applicable, by monitoring for all pollutants at the point where the wastewater containing those pollutants leaves the bleach plant.

[63 FR 18635, Apr. 15, 1998; 63 FR 42239 Aug. 7, 1998]

§ 430.57 - Pretreatment standards for new sources (PSNS).

Except as provided in 40 CFR 403.7, any new source subject to this subpart that introduces pollutants into a publicly owned treatment works must: comply with 40 CFR part 403; and achieve the following pretreatment standards for new sources (PSNS).

(a) (1) The following pretreatment standards apply to each indirect discharger in the calcium-,

magnesium-, or sodium-based sulfite pulp segment that is a new source:

Subpart E

[Production of Calcium-, Magnesium-, or Sodium-Based Sulfite Pulps]

Pollutant or pollutant property PSNS Maximum for any 1 day Monthly
average
kg/kkg (or pounds per 1,000 lb) of product AOX<ML a( b)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(2)(i) The following standards apply to each indirect discharger in the ammonium-based sulfite pulp segment that is a new source:

Subpart E—Production of Ammonium-Based Sulfite Pulps

Pollutant or pollutant property PSNS Maximum for any 1 day Monthly
average
TCDD a<ML b( c) TCDF a<ML b( c) Trichlorosyringol a<ML b( c) 3,4,5-trichlorocatechol a<ML b( c) 3,4,6-trichlorocatechol a<ML b( c) 3,4,5-trichloroguaiacol a<ML b( c) 3,4,6-trichloroguaiacol a<ML b( c) 4,5,6-trichloroguaiacol a<ML b( c) 2,4,5-trichlorophenol a<ML b( c) 2,4,6-trichlorophenol a<ML b( c) Tetrachlorocatechol a<ML b( c) Tetrachloroguaiacol a<ML b( c) 2,3,4,6-tetrachlorophenol a<ML b( c) Pentachlorophenol a<ML b( c)

a These limitations do not apply with respect to fiber lines operated by any indirect discharger that discloses to the pretreatment control authority, at the time it submits the report required under 40 CFR 403.12 (b), (d), or (e), that it uses a TCF bleaching process at that fiber line.

b “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

c This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(ii) The following pretreatment standards apply with respect to each new source fiber line operated by an indirect discharger producing ammonium-based sulfite pulps if the indirect discharger discloses to the pretreatment control authority in a report submitted under 40 CFR 403.12(b), (d), or (e) that it uses exclusively TCF bleaching processes at that fiber line:

Subpart E—Production of Ammonium-Based Sulfite Pulps

Pollutant or pollutant parameter PSNS (TCF) Maximum for any 1 day Monthly
average
AOX<ML a( b)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(3)(i) The following pretreatment standards apply to each indirect discharger in the specialty grade sulfite pulp segment that is a new source:

Subpart E—Production of Specialty Grade Sulfite Pulps

Pollutant or pollutant property PSNS Maximum for any 1 day Monthly
average
TCDD a<ML b( c) TCDF a<ML b( c) Trichlorosyringol a<ML b( c) 3,4,5-trichlorocatechol a<ML b( c) 3,4,6-trichlorocatechol a<ML b( c) 3,4,5-trichloroguaiacol a<ML b( c) 3,4,6-trichloroguaiacol a<ML b( c) 4,5,6-trichloroguaiacol a<ML b( c) 2,4,5-trichlorophenol a<ML b( c) 2,4,6-trichlorophenol a<ML b( c) Tetrachlorocatechol a<ML b( c) Tetrachloroguaiacol a<ML b( c) 2,3,4,6-tetrachlorophenol a<ML b( c) Pentachlorophenol a<ML b( c)

a These limitations do not apply with respect to fiber lines operated by any indirect discharger that discloses to the pretreatment control authority, at the time it submits the report required under 40 CFR 403.12 (b), (d), or (e), that it uses a TCF bleaching process at that fiber line.

b “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

c This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(ii) The following pretreatment standards apply with respect to each new source fiber line operated by an indirect discharger producing specialty grade sulfite pulps if the indirect discharger discloses to the pretreatment control authority in a report submitted under 40 CFR 403.12(b), (d), or (e) that it uses exclusively TCF bleaching processes at that fiber line:

Subpart E—Production of Specialty Grade Sulfite Pulps

Pollutant or pollutant parameter PSNS (TCF) Maximum for any 1 day Monthly
average
AOX<ML a( b)

a “<ML” means less than the minimum level specified in § 430.01(i) for the particular pollutant.

b This regulation does not specify this type of limitation for this pollutant; however, pretreatment control authorities may do so as appropriate.

(b) The following pretreatment standards shall apply to each new source indirect dischargers unless the indirect discharger certifies to the pretreatment control authority that it is not using these compounds as biocides. In cases when POTWs find it necessary to impose mass effluent standards, equivalent mass standards are provided as guidance:

Subpart E

Pollutant or pollutant property Supplemental PSNS Maximum for any 1 day kg/kkg (or pounds per 1,000 lb) of product Milligrams/liter Pentachlorophenol0.00058exp (0.017x)((0.015)(9.12)exp(0.017x))/y Trichlorophenol0.0043exp (0.017x)((0.114)(9.12)exp(0.017x))/y x = percent sulfite pulp in final product. y = wastewater discharged in kgal per ton of product.

(c) An indirect discharger must demonstrate compliance with the pretreatment standards in paragraphs (a)(2) or (a)(3) of this section, as applicable, by monitoring for all pollutants at the point where the wastewater containing those pollutants leaves the bleach plant.

[63 FR 18635, Apr. 15, 1998; 63 FR 42240, Aug. 7, 1998]

§ 430.58 - Best management practices (BMPs).

The definitions and requirements set forth in 40 CFR 430.03 apply to facilities in this subpart.