§ 26.163 - Cutoff levels for drugs and drug metabolites.

(a) Initial drug testing. (1) HHS-certified laboratories shall apply the following cutoff levels for initial testing of specimens to determine whether they are negative or positive for the indicated drugs and drug metabolites, except as specified in paragraph (a)(2) of this section or the licensee or other entity has established more stringent cutoff levels:

Table 1 to Paragraph (a)(1)—Urine, Initial Test Cutoff Levels for Drugs and Drug Metabolites

Drugs or drug metabolites Cutoff level
[nanograms
(ng)/mL]
Marijuana metabolites50 Cocaine metabolites150 Opioids: Codeine/Morphine 12,000 Hydrocodone/Hydromorphone300 Oxycodone/Oxymorphone100 6-acetylmorphine (6-AM)10 Phencyclidine (PCP)25 Amphetamines: 2AMP/MAMP 3500 MDMA 4/MDA 5500

1 Morphine is the target analyte for codeine/morphine testing.

2 Either a single initial test kit or multiple initial test kits may be used provided the single test kit detects each target analyte independently at the specified cutoff.

3 Methamphetamine (MAMP) is the target analyte for amphetamine (AMP)/MAMP testing.

4 Methylenedioxymethamphetamine.

5 Methylenedioxyamphetamine.

Table 2 to Paragraph (a)(1)—Oral Fluid, Initial Test Cutoff Levels for Drugs and Drug Metabolites

Drugs or drug metabolites Cutoff level 1
[nanograms
(ng)/mL]
Marijuana (THC) 2 34 Cocaine/Benzoylecgonine15 Opioids: Codeine/Morphine30 Hydrocodone/Hydromorphone30 Oxycodone/Oxymorphone30 6-acetylmorphine (6-AM)4 3Phencyclidine (PCP)10 Amphetamines: AMP/MAMP 450 MDMA/MDA 550

1 For grouped analytes (i.e., two or more analytes in the same drug class with the same initial test cutoff):

• Immunoassay: The test must be calibrated with one analyte from the group identified as the target analyte. The cross reactivity of the immunoassay to the other analyte(s) within the group must be 80 percent or greater; if not, separate immunoassays must be used for the analytes within the group.

• Alternative technology: Either one analyte or all analytes from the group must be used for calibration, depending on the technology. At least one analyte within the group must have a concentration equal to or greater than the initial test cutoff or, alternatively, the sum of the analytes present.

2 An immunoassay must be calibrated with the target analyte, delta-9-tetrahydrocannabinol (THC).

3 Alternate technology (THC and 6-AM): The confirmatory tests cutoff must be used for an alternate technology initial test that is specific for the target analyte (i.e., 2 ng/mL for THC, 2 ng/mL for 6-AM).

4 Amphetamine (AMP) and methamphetamine (MAMP).

5 Methylenedioxymethamphetamine (MDMA) and methylenedioxyamphetamine (MDA).

(2) HHS-certified laboratories shall conduct special analyses of specimens as follows:

(i) If initial validity testing indicates that a specimen is dilute, or if a specimen is collected under direct observation for any of the conditions specified in § 26.115(a)(1) through (3) or (a)(5), the laboratory shall compare the immunoassay responses of the specimen to the cutoff calibrator in each drug class tested;

(ii) If any immunoassay response is equal to or greater than 40 percent of the cutoff calibrator, the laboratory shall conduct confirmatory drug testing of the specimen to the LOQ for those drugs and/or drug metabolites; and

(iii) The laboratory shall report the numerical values obtained from this special analysis to the MRO.

(b) Confirmatory drug testing. (1) A specimen that is identified as positive on an initial drug test must be subject to confirmatory testing for the class(es) of drugs for which the specimen initially tested positive. The HHS-certified laboratory shall apply the confirmatory cutoff levels specified in this paragraph, except as permitted in paragraph (a)(2) of this section or the licensee or other entity has established more stringent cutoff levels.

Table 3 to Paragraph (b)(1)—Urine, Confirmatory Test Cutoff Levels for Drugs and Drug Metabolites

Drugs or drug metabolites Cutoff level
(ng/mL)
Marijuana metabolite 115 Cocaine metabolite 2100 Opioids: Morphine2,000 Codeine2,000 Hydrocodone100 Hydromorphone100 Oxycodone100 Oxymorphone100 6-acetylmorphine (6-AM)10 Phencyclidine (PCP)25 Amphetamines: Amphetamine250 Methamphetamine 3250 Methylenedioxymethamphetamine (MDMA)250 Methylenedioxyamphetamine (MDA)250

1 As delta-9-tetrahydrocannabinol-9-carboxylic acid (THCA).

2 As benzoylecgonine.

3 To be reported positive for methamphetamine, a specimen must also contain amphetamine at a concentration equal to or greater than 100 ng/mL.

Table 4 to Paragraph (b)(1)—Oral Fluid, Confirmatory Test Cutoff Levels for Drugs and Drug Metabolites

Drugs or drug metabolites Cutoff level
[nanograms
(ng)/mL]
Marijuana (THC)2 Cocaine8 Benzoylecgonine8 Opioids: Codeine15 Morphine15 Hydrocodone15 Hydromorphone15 Oxycodone15 Oxymorphone15 6-acetylmorphine (6-AM)2 Phencyclidine (PCP)10 Amphetamines: Amphetamine25 Methamphetamine25 Methylenedioxymethamphetamine (MDMA)25 Methylenedioxyamphetamine (MDA)25

(2) Each confirmatory drug test must provide a quantitative result. When the concentration of a drug or metabolite exceeds the linear range of the standard curve, the laboratory may record the result as “exceeds the linear range of the test” or as “equal to or greater than <insert the value for the upper limit of the linear range>,” or may dilute an aliquot of the specimen to obtain an accurate quantitative result when the concentration is above the upper limit of the linear range.

[73 FR 17176, Mar. 31, 2008, as amended at 87 FR 71460, Nov. 22, 2022]