Appendix A - Appendix A to Part 121—First Aid Kits and Emergency Medical Kits

Approved first-aid kits, at least one approved emergency medical kit, and at least one approved automated external defibrillator required under § 121.803 of this part must be readily accessible to the crew, stored securely, and kept free from dust, moisture, and damaging temperatures.

First-aid Kits

1. The minimum number of first aid kits required is set forth in the following table:

No. of passenger seats No. of first-aid kits 0-501 51-1502 151-2503 More than 2504

2. Except as provided in paragraph (3), each approved first-aid kit must contain at least the following appropriately maintained contents in the specified quantities:

Contents Quantity Adhesive bandage compresses, 1-inch16 Antiseptic swabs20 Ammonia inhalants10 Bandage compresses, 4-inch8 Triangular bandage compresses, 40-inch5 Arm splint, noninflatable1 Leg splint, noninflatable1 Roller bandage, 4-inch4 Adhesive tape, 1-inch standard roll2 Bandage scissors1

3. Arm and leg splints which do not fit within a first-aid kit may be stowed in a readily accessible location that is as near as practicable to the kit.

Emergency Medical Kits

1. Until April 12, 2004, at least one approved emergency medical kit that must contain at least the following appropriately maintained contents in the specified quantities:

Contents Quantity Sphygmomanometer1 Stethoscope1 Airways, cropharyngeal (3 sizes)3 Syringes (sizes necessary to administer required drugs)4 Needles (sizes necessary to administer required drugs)6 50% Dextrose injection, 50cc1 Epinephrine 1:1000, single dose ampule or equivalent)2 Diphenhydramine HC1 injection, single dose ampule or equivalent2 Nitroglycerin tablets10 Basic instructions for use of the drugs in the kit1 protective nonpermeable gloves or equivalent1 pair

2. As of April 12, 2004, at least one approved emergency medical kit that must contain at least the following appropriately maintained contents in the specified quantities:

Contents Quantity Sphygmonanometer1 Stethoscope1 Airways, oropharyngeal (3 sizes): 1 pediatric, 1 small adult, 1 large adult or equivalent3 Self-inflating manual resuscitation device with 3 masks (1 pediatric, 1 small adult, 1 large adult or equivalent)1:3 masks CPR mask (3 sizes), 1 pediatric, 1 small adult, 1 large adult, or equivalent3 IV Admin Set: Tubing w/ 2 Y connectors1 Alcohol sponges2 Adhesive tape, 1-inch standard roll adhesive1 Tape scissors1 pair Tourniquet1 Saline solution, 500 cc1 Protective nonpermeable gloves or equivalent1 pair Needles (2-18 ga., 2-20 ga., 2-22 ga., or sizes necessary to administer required medications)6 Syringes (1-5 cc, 2-10 cc, or sizes necessary to administer required medications)4 Analgesic, non-narcotic, tablets, 325 mg4 Antihistamine tablets, 25 mg4 Antihistamine injectable, 50 mg, (single dose ampule or equivalent)2 Atropine, 0.5 mg, 5 cc (single dose ampule or equivalent)2 Aspirin tablets, 325 mg4 Bronchodilator, inhaled (metered dose inhaler or equivalent)1 Dextrose, 50%/50 cc injectable, (single dose ampule or equivalent)1 Epinephrine 1:1000, 1 cc, injectable, (single dose ampule or equivalent)2 Epinephrine 1:10,000, 2 cc, injectable, (single dose ampule or equivalent)2 Lidocaine, 5 cc, 20 mg/ml, injectable (single dose ampule or equivalent)2 Nitroglycerin tablets, 0.4 mg10 Basic instructions for use of the drugs in the kit1

3. If all of the above-listed items do not fit into one container, more than one container may be used.

Automated External Defibrillators

At least one approved automated external defibrillator, legally marketed in the United States in accordance with Food and Drug Administration requirements, that must:

1. Be stored in the passenger cabin.

2. After April 30, 2005:

(a) Have a power source that meets FAA Technical Standard Order requirements for power sources for electronic devices used in aviation as approved by the Administrator; or

(b) Have a power source that was manufactured before July 30, 2004, and been found by the FAA to be equivalent to a power source that meets the Technical Standard Order requirements of paragraph (a) of this section.

3. Be maintained in accordance with the manufacturer's specifications.

[Doc. No. FAA-2000-7119, 66 FR 19044, Apr. 12, 2001, as amended by Amdt. 121-280, 69 FR 19762, Apr. 14, 2004; Amdt. 121-309, 70 FR 15196, Mar. 24, 2005]