- Table 2 to Subpart O of Part 63—Standards for ARVs

As required in § 63.362(d), for each ARV, you must meet the applicable standard in the following table:

For each . . . For which . . . You must . . . You must comply with the standard . . . 1. Existing ARVa. Facility EtO use is at least 10 tpyi. Continuously reduce EtO emissions by 99 percent 1Until April 6, 2026. b. Facility EtO use is at least 30 tpyi. Continuously reduce EtO emissions by 99.9 percent 2 3No later than April 6, 2026. c. Facility EtO use is at least 10 tpy but less than 30 tpyi. Continuously reduce EtO emissions by 99.6 percent 2 3No later than April 6, 2026. d. Facility EtO use is less than 10 tpyi. Continuously reduce EtO emissions by 99 percent 2 4No later than April 5, 2027. 2. New ARVa. Initial startup is on or before April 5, 2024, and facility EtO use is at least 10 tpyi. Continuously reduce EtO emissions by 99.9 percent 2 5No later than April 5, 2024. b. Initial startup is on or before April 5, 2024, and facility EtO use is less than 10 tpyi. Continuously reduce EtO emissions by 99 percent 2 6No later than April 5, 2024. c. Initial startup is after April 5, 2024, and facility EtO use is at least 10 tpyi. Continuously reduce EtO emissions by 99.9 percent 2 5Upon startup of the source. d. Initial startup is after April 5, 2024, and facility EtO use is less than 10 tpyi. Continuously reduce EtO emissions by 99 percent 2 6Upon startup of the source.

1 The standard applies if the facility has met or exceeded the specified EtO use within any consecutive 12-month period after December 6, 1996.

2 If using CEMS to determine compliance, this standard is based on a rolling 30-operating day average.

3 The standard applies if the facility has met or exceeded the specified EtO use within any consecutive 12-month period after April 7, 2025.

4 The standard applies if the facility has used less than 10 tpy of EtO within all consecutive 12-month periods after April 6, 2026.

5 The standard applies if the facility is expected to meet or exceed the specified EtO use within one year after startup. Afterwards, the standard applies if the facility has met or exceeded the specified EtO use within any consecutive 12-month period after startup.