- Table 2 to Subpart SSSSS of Part 63—Operating Limits

As stated in § 63.9788, you must comply with the operating limits for affected sources in the following table:

For . . . You must . . . 1. Each affected source listed in Table 1 to this subparta. Operate all affected sources according to the requirements to this subpart on and after the date on which the initial performance test is conducted or required to be conducted, whichever date is earlier; and b. Capture emissions and vent them through a closed system; and c. Operate each control device that is required to comply with this subpart on each affected source during all periods that the source is operating, except where specified in § 63.9792(e), item 2 of this table, item 5 of Table 3 to this subpart, item 13 of Table 4 to this subpart, and item 6 of Table 9 to this subpart for THC control devices on continuous kilns used to manufacture refractory products that use organic HAP; and d. Record all operating parameters specified in Table 8 to this subpart for the affected source; and e. Prepare and implement a written OM&M plan as specified in § 63.9792(d). 2. Each affected continuous kiln used to manufacture refractory products that use organic HAP that is equipped with an emission control device for THCa. Receive approval from the Administrator before taking the control device on the affected kiln out of service for scheduled maintenance, as specified in § 63.9792(e); and
b. Before May 19, 2022, minimize HAP emissions from the affected kiln during all periods of scheduled maintenance of the kiln control device when the kiln is operating and the control device is out of service; on and after May 19, 2022, you must minimize HAP emissions during the period when the kiln is operating and the control device is out of service by complying with the applicable standard in Table 3 to this subpart; and
c. Minimize the duration of all periods of scheduled maintenance of the kiln control device when the kiln is operating and the control device is out of service. On and after May 19, 2022, the total time during which the kiln is operating and the control device is out of service for the each year on a 12-month rolling basis must not exceed 750 hours. 3. Each new or existing curing oven, shape dryer, and kiln that is used to process refractory products that use organic HAP; each new or existing coking oven and defumer that is used to produce pitch-impregnated refractory products; each new shape preheater that is used to produce pitch-impregnated refractory products; AND each new or existing process unit that is exhausted to a thermal or catalytic oxidizer that also controls emissions from an affected shape preheater or pitch working tankSatisfy the applicable operating limits specified in items 4 through 9 of this table. 4. Each affected continuous process unitMaintain the 3-hour block average organic HAP processing rate (pounds per hour) at or below the maximum organic HAP processing rate established during the most recent performance test. 5. Continuous process units that are equipped with a thermal oxidizerMaintain the 3-hour block average operating temperature in the thermal oxidizer combustion chamber at or above the minimum allowable operating temperature for the oxidizer established during the most recent performance test. 6. Continuous process units that are equipped with a catalytic oxidizera. Maintain the 3-hour block average operating temperature at the inlet of the catalyst bed of the oxidizer at or above the minimum allowable operating temperature for the oxidizer established during the most recent performance test; and b. Check the activity level of the catalyst at least every 12 months. 7. Each affected batch process unitFor each batch cycle, maintain the organic HAP processing rate (pounds per batch) at or below the maximum organic HAP processing rate established during the most recent performance test. 8. Batch process units that are equipped with a thermal oxidizera. From the start of each batch cycle until 3 hours have passed since the process unit reached maximum temperature, maintain the hourly average operating temperature in the thermal oxidizer combustion chamber at or above the minimum allowable operating temperature established for the corresponding period during the most recent performance test, as determined according to item 11 of Table 4 to this subpart; and b. For each subsequent hour of the batch cycle, maintain the hourly average operating temperature in the thermal oxidizer combustion chamber at or above the minimum allowable operating temperature established for the corresponding hour during the most recent performance test, as specified in item 13 of Table 4 to this subpart. 9. Batch process units that are equipped with a catalytic oxidizera. From the start of each batch cycle until 3 hours have passed since the process unit reached maximum temperature, maintain the hourly average operating temperature at the inlet of the catalyst bed at or above the minimum allowable operating temperature established for the corresponding period during the most recent performance test, as determined according to item 12 of Table 4 to this subpart; and b. For each subsequent hour of the batch cycle, maintain the hourly average operating temperature at the inlet of the catalyst bed at or above the minimum allowable operating temperature established for the corresponding hour during the most recent performance test, as specified in item 13 of Table 4 to this subpart; and c. Check the activity level of the catalyst at least every 12 months. 10. Each new kiln that is used to process clay refractory productsSatisfy the applicable operating limits specified in items 11 through 13 of this table. 11. Each affected kiln that is equipped with a DLAa. Maintain the 3-hour block average pressure drop across the DLA at or above the minimum levels established during the most recent performance test; and b. Maintain free-flowing limestone in the feed hopper, silo, and DLA at all times; and c. Maintain the limestone feeder at or above the level established during the most recent performance test; and d. Use the same grade of limestone from the same source as was used during the most recent performance test and maintain records of the source and type of limestone used; and e. Maintain no VE from the stack. 12. Each affected kiln that is equipped with a DIFF or DLS/FFa. Initiate corrective action within 1 hour of a bag leak detection system alarm and complete corrective actions in accordance with the OM&M plan; and b. Verify at least once each 8-hour shift that lime is free-flowing by means of a visual check, checking the output of a load cell, carrier gas/lime flow indicator, or carrier gas pressure drop measurement system; and c. Record the lime feeder setting daily to verify that the feeder setting is at or above the level established during the most recent performance test. 13. Each affected kiln that is equipped with a wet scrubbera. Maintain the 3-hour block average pressure drop across the scrubber, liquid pH, and liquid flow rate at or above the minimum levels established during the most recent performance test; and b. If chemicals are added to the scrubber liquid, maintain the 3-hour block average chemical feed rate at or above the minimum chemical feed rate established during the most recent performance test. 14. Each new and existing kiln used to process clay refractory products that is equipped with an activated carbon injection systemMaintain the average carbon flow rate for each 3-hour block period at or above the average carbon flow rate established during the Hg performance test in which compliance was demonstrated. 15. Each new and existing kiln that is used to process clay refractory products with no add-on control and each existing kiln that is equipped with a DLAMaintain no VE from the stack. 16. Each existing kiln used to process clay refractory products that is equipped with a FFInitiate corrective action within 1 hour of a bag leak detection system alarm and complete corrective actions in accordance with the OM&M plan OR maintain no VE from the stack. 17. Each existing kiln used to process clay refractory products that is equipped with a wet scrubberMaintain the 3-hour block average pressure drop across the scrubber and liquid flow rate at or above the minimum levels established during the most recent performance test.
[86 FR 66070, Nov. 19, 2021]