View all text of Subpart B [§ 211.201 - § 211.214]

§ 211.207 - Computation of the noise reduction rating (NRR).

Calculate the NRR for hearing protective devices by substituting the average attenuation values and standard deviations for the pertinent protector category for the sample data used in steps #6 and #7 in Figure 2. The values of −.2, 0, 0, 0, −.2, −.8, −3.0 in Step 2 and −16.1, −8.6, −3.2, 0, + 1.2, + 1.0, −1.1 in Step 4 of Figure 2 represent the standard “C”- and “A”-weighting relative response corrections applied to any sound levels at the indicated octave band center frequencies. (NOTE: The manufacturer may label the protector at values lower than indicated by the test results and this computation procedure, e.g. lower NRR from lower attenuation values. (Ref. § 211.211(b).)

Figure 2—Computation of the Noise Reduction Rating

Octave band center frequency (Hz)125250500100020003000400060008000 1 Assumed Pink noise (dB)100100100100100100100 2 “C” weighting corrections (dB)−.2000−.2−.8−3.0 3 Unprotected ear “C”-weighted level (dB)99.810010010099.899.297.0 (The seven logarithmically added “C”-weighted sound pressure levels of Step #3 = 107.9 dS) 4 “A”-weighting corrections (dB)−16.1−8.6−3.20 + 1.2 + 1.0−1.1 5 Unprotected ear “A”-weighted level (step #1-step #4) (dB)83.991.496.8100101.210198.9 6 Average attenuation in dB at frequency2122232941(43 + 47)/2 = 45(41 + 36)/2 = 38.5 7 Standard deviation in dB at frequency3.73.33.84.73.3(3.3 + 3.4) = 6.7(6.1 + 6.5) = 12.6 × 2 × 2 × 2 × 2 × 27.46.67.69.46.68 Step #5-(step #6-step #7) develops the protected ear “A” weighted levels (dB)70.376.081.480.466.862.773.0 (The seven logarithmically added “A”-weighted sound pressure levels of Step #8 using this sample data = 85.1 dB) 9 NRR = Step #3—Step #8—3 dB*; = 107.9 dB—85.1 dB—3 dB*; = 19.8 dB (or 20) (Round values ending in .5 to next lower whole number).

*Spectral uncertainty (as defined in § 211.203).

The value for #3 is constant. Use Logarithmic mathematics to determine the combined value of protected ear levels (Step #8) which is used in Step #9 to exactly derive the NRR; or use the following table as a substitute for logarithmic mathematics to determine the value of Step #8 and thus very closely approximate the NRR.
Difference between any two sound pressure levels being combined (dB) Add this level to the higher of the two levels (dB) 0 to less than 1.53 1.5 to less than 4.52 4.5 to 91 Greater than 90