View all text of Subpart B [§ 420.20 - § 420.29]

§ 420.25 - Pretreatment standards for existing sources (PSES).

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and must achieve the following pretreatment standards for existing sources (PSES):

(a) Sintering operations with wet air pollution control system. The following table presents PSES for sintering operations with wet air pollution control systems:

Subpart B—Pretreatment Standards for Existing Sources (PSES)

Regulated parameter Maximum daily 1Maximum monthly avg. 1Ammonia-N 2 30.01500.00501 Cyanide 20.003000.00150 Phenols (4AAP) 20.0001000.0000501 Lead0.0004510.000150 Zinc0.0006760.000225 2,3,7,8-TCDF<ML

1 Pounds per thousand lb of product.

2 The pretreatment standards for these parameters apply only when sintering wastewater is co-treated with ironmaking wastewater.

3 The pretreatment standards for ammonia are not applicable to sources that discharge to a POTW with nitrification capability (defined at § 420.02(s)).

(b) Sintering operations with dry air pollution control system. There shall be no discharge of process wastewater pollutants to POTWs.

[67 FR 64265, Oct. 17, 2002]