View all text of Subpart I [§ 420.90 - § 420.97]

§ 420.97 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional technology (BCT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional technology.

(a) Sulfuric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire and coil.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.08190.0350 O&G 10.03500.0117 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(2) Bar, billet and bloom.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.02630.0113 O&G 10.01130.00376 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(3) Strip, sheet and plate.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.05260.0225 O&G 10.02250.00751 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(4) Pipe, tube and other products.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.1460.0626 O&G 10.06260.0209 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(5) Fume scrubbers.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kilograms per day TSS5.722.45 O&G 12.450.819 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

The above limitations shall be applicable to each fume scrubber associated with a sulfuric acid pickling operation.

(b) Hydrochloric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire and coil.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.1430.0613 O&G 10.06130.0204 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(2) Strip, sheet and plate.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.08190.0350 O&G 10.03500.0117 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(3) Pipe, tube and other products.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.2980.128 O&G 10.1280.0426 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0

(4) Fume scrubbers.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kilograms per day TSS5.722.45 O&G 12.450.819 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

The above limitations shall be applicable to each fume scrubber associated with a hydrochloric acid pickling operation.

(5) Acid regeneration (absorber vent scrubber).

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kilograms per day TSS38.216.3 O&G 116.35.45 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

The above limitations shall be applicable to the absorber vent scrubber wastewater associated with hydrochloric acid regeneration plants.

(c) Combination acid pickling (spent acid solution and rinse waters)—(1) Rod, wire, and coil.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.1490.0638 O&G 10.06380.0213 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(2) Bar, billet, and bloom.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.06720.0288 O&G 10.02880.00960 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(3) Strip, sheet, and plate—continuous.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.4380.188 O&G 10.1880.0626 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(4) Strip, sheet and plate—batch.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.1340.0576 O&G 10.05760.0192 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(5) Pipe, tube, and other products.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product TSS0.2250.0964 O&G 10.09640.0321 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

(6) Fume scrubbers.

Subpart I

Pollutant or pollutant property BCT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kilograms per day TSS5.722.45 O&G 12.450.819 pH( 2)( 2)

1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.

2 Within the range of 6.0 to 9.0.

The above limitations shall be applicable to each fume scrubber associated with a combination acid pickling operation. [47 FR 23284, May 27, 1982; 47 FR 41739, Sept. 22, 1982]