(a) Cold rolling mills—(1) Recirculation—single stand.

Subpart J

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.00002090.0000084 Lead0.00000940.0000031 Nickel 10.00001880.0000063 Zinc0.00000630.0000021 Naphthalene0.0000021Tetrachloroethylene0.0000031

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Recirculation—multiple stands.

Subpart J

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.0001040.0000418 Lead0.00004690.0000156 Nickel 10.00009390.0000313 Zinc0.00003130.0000104 Naphthalene0.0000104Tetrachloroethylene0.0000156

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(3) Combination.

Subpart J

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.001250.000501 Lead0.0005630.000188 Nickel 10.001130.000376 Zinc0.0003760.000125 Naphthalene0.000125Tetrachloroethylene0.000188

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are cotreated with descaling or combination acid pickling wastewaters.

(4) Direct application—single stand.

Subpart J

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.0003760.000150 Lead0.0001690.0000563 Nickel 10.0003380.000113 Zinc0.0001130.0000376 Naphthalene0.0000376Tetrachloroethylene0.0000563

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(5) Direct application—multiple stands.

Subpart J

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.001670.000668 Lead0.0007510.000250 Nickel 10.001500.000501 Zinc0.0005010.000167 Naphthalene0.000167Tetrachloroethylene0.000250

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(b) Cold worked pipe and tube—(1) Using water.

Subpart J

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.00002090.0000084 Lead0.00000940.0000031 Nickel 10.00001880.0000063 Zinc0.00000630.0000021

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Using oil solutions.

Subpart J

Pollutant or pollutant property BAT effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.00002090.0000084 Lead0.00000940.0000031 Nickel 10.00001880.0000063 Zinc0.00000630.0000021 Naphthalene0.0000021Tetrachloroethylene0.0000031

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.

[47 FR 23284, May 27, 1982, as amended at 49 FR 21035, May 17, 1984]