View all text of Subpart J [§ 420.100 - § 420.107]

§ 420.106 - Pretreatment standards for new sources (PSNS).

Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources.

(a) Cold rolling—(1) Recirculation—single stand.

Subpart J

Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.00002090.0000084 Lead0.00000940.0000031 Nickel 10.00001880.0000063 Zinc0.00000630.0000021 Naphthalene0.0000021Tetrachloroethylene0.0000031

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Recirculation—multiple stands.

Subpart J

Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.00004180.0000167 Lead0.00001880.0000063 Nickel 10.00003760.0000125 Zinc0.00001250.0000042 Naphthalene0.0000042Tetrachloroethylene0.0000063

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(3) Combination.

Subpart J

Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 10.0005430.000217 Lead0.0002440.0000814 Nickel 10.0004880.000163 Zinc0.0001630.0000542 Naphthalene0.0000542Tetrachloroethylene0.0000813

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(4) Direct application—single stand.

Subpart J

Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg pounds per 1,000 lb) of product Chromium 10.0001040.0000418 Lead0.00004690.0000156 Nickel 10.00009390.0000313 Zinc0.00003130.0000104 Naphthalene0.0000104Tetrachloroethylene0.0000156

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(5) Direct application—multiple stands.

Subpart J

Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg pounds per 1,000 lb) of product Chromium 10.001210.000484 Lead0.0005450.000182 Nickel 10.001090.000363 Zinc0.0003630.000121 Naphthalene0.000121Tetrachloroethylene0.000182

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(b) Cold worked pipe and tube mills—(1) Using water.

Subpart J

Pollutant or pollutant property Pretreatment standards for new sources Maximum for any one day Average of daily values for 30 consecutive days kg/kkg (pounds per 1,000 lb) of product Chromium 10.00002090.0000084 Lead0.00000940.0000031 Nickel 10.00001880.0000063 Zinc0.00000630.0000021

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Using oil solutions.

Subpart J

Pollutant or pollutant property Pretreatment standards for new sources Maximum for any one day Average of daily values for 30 consecutive days kg/kkg (pound per 1,000 lb) of product Chromium 10.00002090.0000084 Lead0.00000940.0000031 Nickel 10.00001880.0000063 Zinc0.00000630.0000021 Naphthalene0.0000021Tetrachloroethylene0.0000031

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewasters.

[47 FR 23284, May 27, 1982, as amended at 49 FR 21035, May 17, 1984]