View all text of Subpart E [§ 461.50 - § 461.55]

§ 461.53 - New source performance standards (NSPS).

(a) The discharge of wastewater pollutants from any new source subject to this subpart shall not exceed the standards set forth below:

(1) Subpart E—Lead Iodide Cathodes—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of lead English units—pounds per 1,000,000 pounds of lead Chromium23.349.46 Lead17.668.20 Iron75.7038.48 TSS946.2756.96 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(2) Subpart E—Iron Disulfide Cathodes—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of Iron disulfide English units—pounds per 1,000,000 pounds of Iron disulfide Chromium2.791.13 Lead2.110.98 Iron9.054.60 TSS113.190.5 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(3) Subpart E—Miscellaneous Wastewater Streams—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of cells produced English units—pounds per 1,000,000 pounds of cells produced Chromium0.0390.016 Lead0.0300.014 Iron0.1290.066 TSS1.621.30 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(4) Subpart E—Air Scrubbers—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of cells produced English units—pounds per 1,000,000 pounds of cells produced TSS434.0207.0 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(b) There shall be no discharge allowance for process wastewater pollutants from any battery manufacturing operation other than those battery manufacturing operations listed above.