(a) The discharge of wastewater pollutants from any new source subject to this subpart shall not exceed the standards set forth below:

(1) Subpart F—Silver Chloride Cathodes—Chemically Reduced—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of silver processed English units—pounds per 1,000,000 pounds of silver processed Lead22.9310.65 Silver23.759.83 Iron98.2849.96 TSS1,228.5982.8 COD4,095.01,999.0 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(2) Subpart F—Silver Chloride Cathodes—Electrolytic—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of silver processed English units—pounds per 1,000,000 pounds of silver processed Lead40.618.9 Silver42.117.4 Iron174.088.5 TSS2,175.01,740.0 COD7,250.03,540.0 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(3) Subpart F—Cell Testing—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of cells produced English units—pounds per 1,000,000 pounds of cells produced Lead19.57.89 Silver15.36.31 Iron63.132.1 TSS789.0631.2 COD2,630.01,290.0 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(4) Subpart F—Floor and Equipment Wash—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of cells produced English units—pounds per 1,000,000 pounds of cells produced Lead0.0260.012 Silver0.0270.011 Iron0.1120.057 COD4.702.30 TSS1.411.13 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(5) Subpart F—Air Scrubber—NSPS.

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metric units—mg/kg of cells produced English units—pounds per 1,000,000 pounds of cells produced TSS8,467.04,030.0 pH( 1)( 1)

1 Within the range of 7.5-10.0 at all times.

(b) There shall be no discharge allowance for process wastewater pollutants from any battery manufacturing operation other than those battery manufacturing operations listed above.