§ 466.11 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations for metal preparation operations and for coating operations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Subpart A—BPT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average Metal preparation Coating operation Metal preparation Coating operation Metric units—mg/m 2 of area processed or coated Chromium16.823.416.811.38 Lead6.011.215.211.06 Nickel56.4611.4340.058.11 Zinc53.2610.7822.434.54 Aluminum182.2036.8774.4715.07 Iron112.1222.6956.0611.34 Oil and grease800.84162.10480.5197.23 TSS1642.00332.20800.90162.00 pH( 1)( 1)( 1)( 1) English Units—pounds per 1 million ft 2 of area processed or coated Chromium3.450.071.400.29 Lead1.230.251.070.22 Nickel11.572.348.201.66 Zinc10.912.214.600.93 Aluminum37.327.5515.263.09 Iron22.964.6511.482.32 Oil and grease164.0333.1998.4219.92 TSS337.0068.10164.0033.20 pH( 1)( 1)( 1)( 1)

1 Within the range 7.5 to 10.0 at all times.

[47 FR 53184, Nov. 24, 1982, as amended at 50 FR 36543, Sept. 6, 1985]