View all text of Subpart B [§ 467.20 - § 467.27]

§ 467.22 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Subpart B Core
Pollutant or pollutant property BPT effluent limitations Maximum for any 1 day Maximum for monthly average mg/off-kg (lb/million off-lbs) of aluminum rolled with emulsions Chromium0.0570.024 Cyanide0.0380.016 Zinc0.190.079 Aluminum0.840.416 Oil and grease2.601.56 Suspended solids5.332.53 pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

Subpart B Direct Chill Casting Contact Cooling Water
Pollutant or pollutant property BPT effluent limitations Maximum for any 1 day Maximum for monthly average mg/off-kg (lb/million off-lbs) of aluminum cast Chromium0.590.24 Cyanide0.390.16 Zinc1.940.81 Aluminum8.554.26 Oil and grease26.5815.95 Suspended solids54.4925.92 pH( 1)( 1)

1 The pH shall be maintained within the range of 7.0 to 10.0 at all times except for those situations when this waste stream is discharged separately and without commingling with any other wastewater in which case the pH shall be within the range of 6.0 to 10.0 at all times.

Subpart B Solution Heat Treatment Contact Cooling Water
Pollutant or pollutant property BPT effluent limitations Maximum for any 1 day Maximum for monthly average mg/off-kg (lb/million off-lbs) of aluminum quenched Chromium3.391.39 Cyanide2.240.93 Zinc11.254.70 Aluminum49.5524.66 Oil and grease154.1092.46 Suspended solids315.91150.25 pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

Subpart B Cleaning or Etching Bath
Pollutant or pollutant property BPT effluent limitations Maximum for any 1 day Maximum for monthly average mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched Chromium0.0790.032 Cyanide0.0520.022 Zinc0.2620.109 Aluminum1.150.573 Oil and grease3.582.15 Suspended solids7.343.49 pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

Subpart B Cleaning or Etching Rinse
Pollutant or pollutant property BPT effluent limitations Maximum for any 1 day Maximum for monthly average mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched Chromium6.122.51 Cyanide4.041.67 Zinc20.318.49 Aluminum89.4644.52 Oil and grease278.24166.95 Suspended solids570.39271.29 pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

Subpart B Cleaning or Etching Scrubber Liquor
Pollutant or pollutant property BPT effluent limitations Maximum for any 1 day Maximum for monthly average mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched Chromium7.002.86 Cyanide4.611.91 Zinc23.229.70 Aluminum102.2450.88 Oil and grease318.00190.80 Suspended solids651.90310.05 pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

[48 FR 49149, Oct. 24, 1983; 49 FR 11631, 11632, Mar. 27, 1984, as amended at 53 FR 52370, Dec. 27, 1988]