§ 1065.790 - Mass standards.
(a) PM balance calibration weights. Use PM balance calibration weights that are certified as NIST-traceable within ±0.1% uncertainty. Make sure your highest calibration weight has no more than ten times the mass of an unused PM-sample medium.