View all text of Subpart OOOOa [§ 60.5360a - § 60.5433a–60.5439a]

§ 60.5405a -

(a) During the initial performance test required by § 60.8(b), you must achieve at a minimum, an SO2 emission reduction efficiency (Zi) to be determined from Table 1 of this subpart based on the sulfur feed rate (X) and the sulfur content of the acid gas (Y) of the affected facility.

(b) After demonstrating compliance with the provisions of paragraph (a) of this section, you must achieve at a minimum, an SO2 emission reduction efficiency (Zc) to be determined from Table 2 of this subpart based on the sulfur feed rate (X) and the sulfur content of the acid gas (Y) of the affected facility.