- Table 2 to Subpart VVVV—Emission Limitations for New Large Municipal Waste Combustors
| For the air pollutant | If your affected facility is a new large municipal waste combustor, you must meet this
emission limit, corrected to 7 percent oxygen a | Particulate matter | 5.1 mg/dscm. | Opacity | 10 percent opacity (6-minute block average). | Cadmium | 2.3 ug/dscm. | Lead | 23 ug/dscm. | Mercury | 32 ug/dscm or 85 percent reduction by weight. | Sulfur dioxide | 14 parts per million by volume dry basis or 79 percent reduction by weight or volume (daily 24-hour geometric average). | Hydrogen chloride | 7.2 parts per million by volume dry basis or 98 percent reduction by weight or volume. | Dioxins/furans | 11 nanograms per dry standard cubic meter (total mass). | Nitrogen oxides | 50 parts per million by volume dry basis (daily 24-hour arithmetic average). |
|---|
a Measured at the combustor outlet in conjunction with a measurement of oxygen concentration. CEMS data during warmup, startup, and shutdown, as defined in this subpart, are not corrected to 7 percent oxygen, and are used as measured. The averaging times are specified in greater detail in § 60.5940.