View all text of Subpart R [§ 61.200 - § 61.210]
§ 61.207 - Radium-226 sampling and measurement procedures.
(a) Before removing phosphogypsum from a stack for distribution in commerce pursuant to § 61.204, or § 61.206, the owner or operator of a phosphogypsum stack shall measure the average radium-226 concentration at the location in the stack from which phosphogypsum will be removed. Measurements shall be performed for each such location prior to the initial distribution in commerce of phosphogypsum removed from that location and at least once during each calendar year while distribution of phosphogypsum removed from the location continues.
(1) A minimum of 30 phosphogypsum samples shall be taken at regularly spaced intervals across the surface of the location on the stack from which the phosphogypsum will be removed. Let n
(2) Measure the radium-226 concentration of each of the n
(3) Calculate the mean, x

(4) Calculate the 95th percentile for the distribution, x

(5) If the purpose for removing phosphogypsum from a stack is for distribution to commerce pursuant to § 61.206, the owner or operator of a phosphogypsum stack shall report the mean, standard deviation, 95th percentile and sample size. If the purpose for removing phosphogypsum from a stack is for distribution to commerce pursuant to § 61.204, the additional sampling procedures set forth in paragraphs (b) and (c) of this section shall apply.
(b) Based on the values for x
(1) If x
(2) If x
(3) If x
(c) If the owner or operator elects to conduct further sampling to determine if phosphogypsum can be removed from this area of the stack, the following procedure shall apply. The objective of the following procedure is to demonstrate, with a 95% probability, that the phosphogypsum from this area of the stack has a radium-226 concentration no greater than 10 pCi/g. The procedure is iterative, the sample size may have to be increased more than one time; otherwise the phosphogypsum cannot be removed from this area of the stack for distribution to commerce pursuant to § 61.204.
(1)(i) Solve the following equation for the total number of samples required:

(ii) The sample size n
(2) Obtain the necessary number of additional samples, n
(3) Measure the radium-226 concentration of each of the n
(4) Recalculate the mean and standard deviation of the entire set of n
(5) Repeat the procedure described in paragraph (a)(4) of this section, substituting the recalculated mean, x
(6) Repeat the procedure described in paragraph (b) of this section, substituting the recalculated mean, x