View all text of Subpart C [§ 18.301 - § 18.313]
§ 18.309 - Frequency range of measurements.
(a) For field strength measurements:
Frequency band in which device operates (MHz) | Range of frequency measurements | Lowest frequency | Highest frequency | Below 1.705 | Lowest frequency generated in the device, but not lower than 9 kHz | 30 MHz. | 1.705 to 30 | Lowest frequency generated in the device, but not lower than 9 kHz | 400 MHz. | 30 to 500 | Lowest frequency generated in the device or 25 MHz, whichever is lower | Tenth harmonic or 1,000 MHz, whichever is higher. | 500 to 1,000 | Lowest frequency generated in the device or 100 MHz, whichever is lower | Tenth harmonic. | Above 1,000 | ......do | Tenth harmonic or highest detectable emission. |
---|
(b) For conducted powerline measurements, the frequency range over which the limits are specified will be scanned.