As stated in § 63.1568(b)(2) and (3), you shall meet each requirement in the following table that applies to you.
| For . . . | You must . . . | Using . . . | According to these
requirements . . . | 1. Option 1: Elect NSPS. Each new and existing sulfur recovery unit | a. Measure SO | Data from continuous emission monitoring system | Collect SO | b. Measure O | i. Data from continuous emission monitoring system; or | Collect O | ii. Data from flow monitor for ambient air and purchased oxygen-enriched gas | Collect gas flow rate monitoring data every 15 minutes for 24 consecutive operating hours. Reduce the data to 1-hour averages computed from 4 or more data points equally spaced over each 1-hour period; calculate the hourly O | 2. Option 2: TRS limit, using CEMS. Each new and existing sulfur recovery unit | Measure the concentration of reduced sulfur (or SO | Data from continuous emission monitoring system | Collect TRS data every 15 minutes for 24 consecutive operating hours. Reduce the data to 1-hour averages computed from four or more data points equally spaced over each 1-hour period. | 3. Option 2: TRS limit, if using continuous parameter monitoring systems. Each new and existing sulfur recovery unit | a. Select sampling port's location and the number of traverse ports | Method 1 or 1A in Appendix A-1 to part 60 of this chapter | Sampling sites must be located at the outlet of the control device and prior to any releases to the atmosphere. | b. Determine velocity and volumetric flow rate | Method 2, 2A, 2C, 2D, or 2F in appendix A-1 to part 60 of this chapter, or Method 2G in appendix A-2 to part 60 of this chapter, as applicable | c. Conduct gas molecular weight analysis; obtain the oxygen concentration needed to correct the emission rate for excess air | Method 3, 3A, or 3B in appendix A-2 to part 60 of this chapter, as applicable | Take the samples simultaneously with reduced sulfur or moisture samples. | d. Measure moisture content of the stack gas | Method 4 in appendix A-3 to part 60 of this chapter | Make your sampling time for each Method 4 sample equal to that for 4 Method 15 samples. | e. Measure the concentration of TRS | Method 15 or 15A in appendix A-5 to part 60 of this chapter, as applicable | If the cross-sectional area of the duct is less than 5 square meters (m 2) or 54 square feet, you must use the centroid of the cross section as the sampling point. If the cross-sectional area is 5 m 2 or more and the centroid is more than 1 meter (m) from the wall, your sampling point may be at a point no closer to the walls than 1 m or 39 inches. Your sampling rate must be at least 3 liters per minute or 0.10 cubic feet per minute to ensure minimum residence time for the sample inside the sample lines. | f. Calculate the SO | The arithmetic average of the SO | g. Correct the reduced sulfur samples to zero percent excess air | Equation 1 of § 63.1568 | h. Establish each operating limit in Table 30 of this subpart that applies to you | Data from the continuous parameter monitoring system | i. Measure thermal incinerator: combustion zone temperature | Data from the continuous parameter monitoring system | Collect temperature monitoring data every 15 minutes during the entire period of the performance test; and determine and record the minimum hourly average temperature from all the readings. | j. Measure thermal incinerator: oxygen concentration (percent, dry basis) in the vent stream | Data from the continuous parameter monitoring system | Collect oxygen concentration (percent, dry basis) data every 15 minutes during the entire period of the performance test; and determine and record the minimum hourly average percent excess oxygen concentration. |
|---|