View all text of Subpart P [§ 98.160 - § 98.168]
§ 98.166 - Data reporting requirements.
In addition to the information required by § 98.3(c), each annual report must contain the following information for each hydrogen production process unit:
(a) The unit identification number.
(b) If a CEMS is used to measure CO
(c) If a material balance is used to calculate emissions using equations P-1 through P-3 to § 98.163, as applicable, report the total annual CO
(d) The information specified in paragraphs (d)(1) through (10):
(1) The type of hydrogen production unit (steam methane reformer (SMR) only, SMR followed by water gas shift reaction (WGS), partial oxidation (POX) only, POX followed by WGS, autothermal reforming only, autothermal reforming followed by WGS, water electrolysis, brine electrolysis, other (specify)).
(2) The type of hydrogen purification method (pressure swing adsorption, amine adsorption, membrane separation, other (specify), none).
(3) Annual quantity of hydrogen produced by reforming, gasification, oxidation, reaction, or other transformation of feedstocks (metric tons).
(4) Annual quantity of hydrogen that is purified only (metric tons). This quantity may be assumed to be equal to the annual quantity of hydrogen in the feedstocks to the hydrogen production unit.
(5) Annual quantity of ammonia intentionally produced as a desired product, if applicable (metric tons).
(6) Quantity of CO
(7) Annual quantity of carbon other than CO
(8) Annual quantity of methanol intentionally produced as a desired product, if applicable, (metric tons) for each process unit.
(9) Annual net quantity of steam consumed by the unit, (metric tons). Include steam purchased or produced outside of the hydrogen production unit. If the hydrogen production unit is a net producer of steam, enter the annual net quantity of steam consumed by the unit as a negative value.
(10) An indication (yes or no) if best available monitoring methods were used, in accordance with § 98.164(c), to determine fuel flow for each stationary combustion unit directly associated with hydrogen production (e.g., reforming furnace and hydrogen production process unit heater). If yes, report:
(i) The beginning date of using best available monitoring methods, in accordance with § 98.164(c), to determine fuel flow for each stationary combustion unit directly associated with hydrogen production (e.g., reforming furnace and hydrogen production process unit heater).
(ii) The anticipated or actual end date of using best available monitoring methods, as applicable, in accordance with § 98.164(c), to determine fuel flow for each stationary combustion unit directly associated with hydrogen production (e.g., reforming furnace and hydrogen production process unit heater).