§ 192.189 - Vaults: Drainage and waterproofing.
(a) Each vault must be designed so as to minimize the entrance of water.
(b) A vault containing gas piping may not be connected by means of a drain connection to any other underground structure.
(c) Electrical equipment in vaults must conform to the applicable requirements of Class 1, Group D, of the National Electrical Code, NFPA-70 (incorporated by reference, see § 192.7).