View all text of Subpart C [§ 192.101 - § 192.127]

§ 192.113 - Longitudinal joint factor (E) for steel pipe.

(a) The longitudinal joint factor to be used in the design formula in § 192.105 is determined in accordance with the table 1 to this paragraph (a):

Table 1 to Paragraph (a)

Specification Pipe class Longitudinal
joint factor
(E)
ASTM A53/A53M (incorporated by reference, see § 192.7)Seamless1.00 Electric resistance welded1.00 Furnace butt welded.60 ASTM A106/A106M (incorporated by reference, see § 192.7)Seamless1.00 ASTM A333/A333M (incorporated by reference, see § 192.7)Seamless1.00 Electric resistance welded1.00 ASTM A381 (incorporated by reference, see § 192.7)Double submerged arc welded1.00 ASTM A671/A671M (incorporated by reference, see § 192.7)Electric-fusion-welded1.00 ASTM A672 (incorporated by reference, see § 192.7)Electric-fusion-welded1.00 ASTM A691/A691M (incorporated by reference, see § 192.7)Electric-fusion-welded1.00 API Spec 5L (incorporated by reference, see § 192.7)Seamless1.00 Electric resistance welded1.00 Electric flash welded1.00 Submerged arc welded1.00 Furnace butt welded.60 OtherPipe over 4 inches (102 millimeters).80 OtherPipe 4 inches (102 millimeters) or less.60

(b) If the type of longitudinal joint cannot be determined, the joint factor to be used must not exceed that designated for “Other.”